1000 resultados para high


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel hanging spherical drop system for anchoring arrays of droplets of cell suspension based on the use of biomimetic superhydrophobic flat substrates, with controlled positional adhesion and minimum contact with a solid substrate. By facing down the platform, it was possible to generate independent spheroid bodies in a high throughput manner, in order to mimic in vivo tumour models on the lab-on-chip scale. To validate this system for drug screening purposes, the toxicity of the anti-cancer drug doxorubicin in cell spheroids was tested and compared to cells in 2D culture. The advantages presented by this platform, such as feasibility of the system and the ability to control the size uniformity of the spheroid, emphasize its potential to be used as a new low cost toolbox for high-throughput drug screening and in cell or tissue engineering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lithium-ion battery cathodes have been fabricated by screen-printing through the development of CLiFePO4 inks. It is shown that shear thinning polymer solutions in N-methyl-2-pyrrolidone (NMP) with Newtonian viscosity above 0.4 Pa s are the best binders for formulating a cathode paste with satisfactory film forming properties. The paste shows an elasticity of the order of 500 Pa and, after shear yielding, shows an apparent viscosity of the order of 3 Pa s for shear rates corresponding to those used during screen-printing. The screen-printed cathode produced with a thickness of 26 mm shows a homogeneous distribution of the active material, conductive additive and polymer binder. The total resistance and diffusion coefficient of the cathode are 450 V and 2.5 10 16cm2 s 1, respectively. The developed cathodes show an initial discharge capacity of 48.2 mAh g 1 at 5C and a discharge value of 39.8 mAh g 1 after 50 cycles. The capacity retention of 83% represents 23% of the theoretical value (charge and/or discharge process in twenty minutes), demonstrating the good performance of the battery. Thus, the developed C-LiFePO4 based inks allow to fabricate screen-printed cathodes suitable for printed lithium-ion batteries

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the management of patients complaining of high blood pressure (BP) in a cardiological emergency room. METHODS: Patients referred to the cardiological emergency room with the main complaint of high blood pressure were consecutively selected. The prescriptions and the choice of antihypertensive drugs were assessed. The classification of these patients as hypertensive emergencies or pseudoemergencies, according to the physician who provided initial care, was recorded. RESULTS: From a total of 858 patients presenting to the emergency room, 80 (9.3%) complained of high BP, and 61 (76.3%) received antihypertensive drugs. Sublingual nifedipine was the most commonly used drug (59%). One patient received intravenous medication, one patient was hospitalized and 6 patients (7.5%) were classified as hypertensive emergencies or pseudoemergencies. CONCLUSION: High BP could seldom be classified as a hypertensive emergency or pseudoemergency, even though it was a frequent complaint (9.3% of visits). Currently, the therapeutic approach is not recommended, even in specialized clinics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the result of patients treated with IV methylprednisolone divided into three groups and compare their follow-up during the last 12 years. METHODS: Seventy children with active rheumatic carditis (76 episodes) in heart failure Class III and IV (NYHA) were studied. The diagnosis was based on modified Jones' criteria. After ruling out infections and strongyloidiasis, treatment with IV methylprednisolone bolus was started three times a week until the laboratory tests became negative. Patients were divided into 3 groups, according to the time of hospital admittance: Groups 1, 2 and 3, comprising of 40, 18 and 12 children, respectively. RESULTS: Eighteen children in Group 1 (45%) were in their 1st attack: 2 series of pulsetherapy were used in 10 (25%), 3 in 9 (23%) and 4 in 21 (52%). In Group 2, 14 cases (77%) were in their 1st attack: 2 series were used in 7 (39%), 4 in 9 (50%) and 5 in 2 (11%). The echocardiogram showed a flail mitral valve in 12 (66%) of these patients (1 death occurred after mitral valvoplasty). In Group 3, 6 patients needed 5 or more series of pulsetherapy and a flail mitral valve was present in 5 (41%). One child underwent mitral valve replacement while still in the active phase, after 8 series of pulsetherapy, and another died. The number of patients who needed 5 or more series was significantly higher in Group 3. CONCLUSION: There were variations in the presentation and evolution of the cases during these 12 year. The established pulsetherapy protocol continues to be useful to treat severe cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between 2008 and 2009 a preventive excavation supervised by the Unit of Archaeology of the University of Minho was conducted in an area with approximately 5000 square meters allowing the identification of a wide sector of the Via XVII necropolis, which is one of the five roman necropolises known to have existed in Bracara Augusta. The findings enabled us to define a typological framework related with incinerations, to understand the internal organization of the necropolis and recover the ritual marks of the funerary practices between the first century BC and the second century AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if abnormal laboratory findings are more common in individuals with hypertension and in those with other risk factors, such as obesity, smoking and alcohol ingestion. METHODS: A study was carried out in the general outpatient clinics of a university hospital (145 individuals without previous diagnosis of hypertension) and the following variables were assessed: high blood pressure (as defined by the VI Joint National Committee on Prevention, Detection and Treatment of High Blood Pressure - VI JNC), obesity [calculated using body mass index (BMI)], tobacco use, and alcoholic ingestion. The laboratory examinations consisted of the following tests: hemogram, glycemia, uric acid, potassium, total/HDL-fraction cholesterol, triglycerides, calcium and creatinine. RESULTS: High blood pressure was not associated with a higher number of abnormal laboratory tests. Hypertensive individuals with a BMI > or = 25kg/m² or normotensive obese individuals, however, had a higher frequency of diabetes (12X), hypertriglyceridemia (3X), and hypercholesterolemia (2X), as compared with hypertensive individuals with BMI <25kg/m² and preobese/normal weight normotensive individuals. CONCLUSION: High blood pressure is not associated with a higher frequency of abnormal laboratory tests. The association of high blood pressure and obesity, however, increases the detection of diabetes and dyslipidemias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genome-scale metabolic models are valuable tools in the metabolic engineering process, based on the ability of these models to integrate diverse sources of data to produce global predictions of organism behavior. At the most basic level, these models require only a genome sequence to construct, and once built, they may be used to predict essential genes, culture conditions, pathway utilization, and the modifications required to enhance a desired organism behavior. In this chapter, we address two key challenges associated with the reconstruction of metabolic models: (a) leveraging existing knowledge of microbiology, biochemistry, and available omics data to produce the best possible model; and (b) applying available tools and data to automate the reconstruction process. We consider these challenges as we progress through the model reconstruction process, beginning with genome assembly, and culminating in the integration of constraints to capture the impact of transcriptional regulation. We divide the reconstruction process into ten distinct steps: (1) genome assembly from sequenced reads; (2) automated structural and functional annotation; (3) phylogenetic tree-based curation of genome annotations; (4) assembly and standardization of biochemistry database; (5) genome-scale metabolic reconstruction; (6) generation of core metabolic model; (7) generation of biomass composition reaction; (8) completion of draft metabolic model; (9) curation of metabolic model; and (10) integration of regulatory constraints. Each of these ten steps is documented in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioengenharia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To characterize the cardiac electrophysiologic effects of cocaine. METHODS: In 8 dogs (9-13 kg), electrophysiologic parameters and programmed stimulation were undertaken using transvenous catheters at baseline, and after cocaine intravenous infusion (12 mg/kg bolus followed by 0.22 mg/kg/min for 25 minutes). RESULTS: Cocaine plasma levels (n=5) rose to 6.73± 0.56 mg/mL. Cocaine did not affect sinus cycle length and arterial pressure. Cocaine prolonged P wave duration (54±6 vs 73±4 ms, P<0.001), PR interval (115±17 vs 164±15 ms, P<0.001), QRS duration (62±10 vs 88±14 ms, P<0.001), and QTc interval (344±28 vs 403±62 ms, P=0.03) but not JT interval (193±35 vs 226±53 ms, NS). Cocaine prolonged PA (9±6 vs 23±8 ms, P<0.001), AH (73±16 vs 92±15 ms; P=0.03), and HV (35±5 vs 45±3ms; P<0.001) intervals and Wenckebach point (247±26 vs 280±28 ms, P=0.04). An increase occurred in atrial (138±8 vs 184± 20 ms; P<0.001) and ventricular (160±15 vs 187±25 ms; P=0.03) refractoriness at a cycle length of 300 ms. Atrial arrhythmias were not induced in any dog. Ventricular fibrillation (VF) was induced in 2/8 dogs at baseline and 4/8 dogs after cocaine. CONCLUSION: High doses of cocaine exert significant class I effects and seem to enhance inducibility of VF but not of atrial arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the acute effects of high glucose concentrations on vascular reactivity in the isolated non diabetic rabbit kidney. METHODS: Rabbits were anaesthetized for isolation of the kidneys. Renal arteries and veins were cannulated for perfusion with Krebs-Henselleit solution and measurement of perfusion pressure. After 3 hours of perfusion with glucose 5,5 mM (control ) and 15 mM, the circulation was submitted to sub maximal precontraction (80% of maximal response) trough continuous infusion of noradrenaline 10 mM. Vascular reactivity was then assessed trough dose-responses curves with endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) vasodilators. The influence of hyperosmolarity was analyzed with perfusion with mannitol 15mM. RESULTS: A significant reduction in the endothelium-dependent vasodilation in glucose 15mM group was observed compared to that in control, but there was no difference in endothelium-independent vasodilation. After perfusion with mannitol 15 mM, a less expressive reduction in endothelium-dependent vasodilation was observed, only reaching significance in regard to the greatest dose of acetylcholine. CONCLUSION: High levels of glucose similar to those found in diabetic patients in the postprandial period can cause significant acute changes in renal vascular reactivity rabbits. In diabetic patients these effects may also occur and contribute to diabetes vascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between blood pressure control and the following: the Morisky-Green test, the patient's consciousness regarding high blood pressure, the patient's attitude in face of medicine intake, the patient's attendance at medical consultations, and the subjective physician's judgment. METHODS: We studied 130 hypertensive patients with the following characteristics: 73% females, 60±11 years, 58% married, 70% white, 45% retired, 45% with incomplete elementary schooling, 64% had a familial income of 1 to 3 minimum wages, body mass index of 30±7 kg/m², consciousness regarding the disease for a mean period of 11±9.5 years, and mean treatment duration of 8 ±7 years. RESULTS: Only 35% of the hypertensive individuals had blood pressure under control and a longer duration of treatment (10±7 vs 7±6.5 years; P<0.05). The retiree predominated. The result of the Morisky-Green test did not relate to blood pressure control. In evaluating the attitude in face of medicine intake, the controlled patients achieved significantly higher scores than did the noncontrolled patients (8±1.9 vs 7 ±2, P<0.05). The hypertensive patients had higher levels of consciousness regarding their disease and its treatment, and most (70%) patients attended 3 or 4 medical consultations, which did not influence blood pressure control. The physicians attributed significantly higher scores regarding adherence to treatment to controlled patients (6±0.8 vs 5±1.2; P<0.05). CONCLUSION: Consciousness regarding the disease, the Morisky-Green test, and attendance to medical consultations did not influence blood pressure control.