892 resultados para full converter type 4 wind turbine generator


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes the experimental setup, procedure, and results obtained, concerning the dynamics of a body lying on a floor, attached to a hinge, and exposed to an unsteady flow, which is a model of the initiation of rotational motion of ballast stones due to the wind generated by the passing of a high-speed train. The idea is to obtain experimental data to support the theoretical model developed in Sanz-Andres and Navarro-Medina (J Wind Eng Ind Aerodyn 98, 772–783, (2010), aimed at analyzing the initial phase of the ballast train-induced-wind erosion (BATIWE) phenomenon. The experimental setup is based on an open circuit, closed test section, low-speed wind tunnel, with a new sinusoidal gust generator mechanism concept, designed and built at the IDR/UPM. The tunnel’s main characteristic is the ability to generate a flow with a uniform velocity profile and sinusoidal time fluctuation of the speed. Experimental results and theoretical model predictions are in good agreement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Protease-activated receptors 1–3 (PAR1, PAR2, and PAR3) are members of a unique G protein-coupled receptor family. They are characterized by a tethered peptide ligand at the extracellular amino terminus that is generated by minor proteolysis. A partial cDNA sequence of a fourth member of this family (PAR4) was identified in an expressed sequence tag database, and the full-length cDNA clone has been isolated from a lymphoma Daudi cell cDNA library. The ORF codes for a seven transmembrane domain protein of 385 amino acids with 33% amino acid sequence identity with PAR1, PAR2, and PAR3. A putative protease cleavage site (Arg-47/Gly-48) was identified within the extracellular amino terminus. COS cells transiently transfected with PAR4 resulted in the formation of intracellular inositol triphosphate when treated with either thrombin or trypsin. A PAR4 mutant in which the Arg-47 was replaced with Ala did not respond to thrombin or trypsin. A hexapeptide (GYPGQV) representing the newly exposed tethered ligand from the amino terminus of PAR4 after proteolysis by thrombin activated COS cells transfected with either wild-type or the mutant PAR4. Northern blot showed that PAR4 mRNA was expressed in a number of human tissues, with high levels being present in lung, pancreas, thyroid, testis, and small intestine. By fluorescence in situ hybridization, the human PAR4 gene was mapped to chromosome 19p12.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This project is funded by RTE, Paris, France

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The human type VII collagen gene (COL7A1) recently has been identified as an immediate-early response gene for transforming growth factor β (TGF-β)/SMAD signaling pathway. In this study, by using MDA-MB-468 SMAD4−/− breast carcinoma cells, we demonstrate that expression of SMAD4 is an absolute requirement for SMAD-mediated promoter activity. We also demonstrate that the SMAD binding sequence (SBS) representing the TGF-β response element in the region −496/−444 of the COL7A1 promoter functions as an enhancer in the context of a heterologous promoter. Electrophoretic mobility-shift assays with nuclear extracts from COS-1 cells transfected with expression vectors for SMADs 1–5 indicate that SMAD3 forms a complex with a migration similar to that of the endogenous TGF-β-specific complex observed in fibroblast extracts. Electrophoretic mobility-shift assays using recombinant glutathione S-transferase-SMAD fusion proteins indicate that both SMAD4 and C-terminally truncated SMAD3, but not SMAD2, can bind the COL7A1 SBS. Coexpression of SMAD3 and SMAD4 in COS-1 cells leads to the formation of two complexes: a DNA/protein complex containing SMAD3 alone and another slower-migrating complex containing both SMAD3 and SMAD4, the latter complex not being detected in fibroblasts. Maximal transactivation of COL7A1 SBS-driven promoters in either MDA-MB-468 carcinoma cells or fibroblasts requires concomitant overexpression of SMAD3 and SMAD4. These data may represent the first identification of a functional homomeric SMAD3 complex regulating a human gene.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An important signaling pathway for the differentiation of T helper type 2 (TH2) cells from uncommitted CD4 T cell precursors is activation of the STAT6 transcription factor by interleukin 4 (IL-4). The protooncogene BCL-6 is also involved in TH2 differentiation, as BCL-6 −/− mice develop an inflammation of the heart and lungs associated with an overproduction of TH2 cells. Surprisingly, IL-4 −/− BCL-6 −/− and STAT6 −/− BCL-6 −/− double-mutant mice developed the same TH2-type inflammation of the heart and lungs as is characteristic of BCL-6 −/− mice. Furthermore, a TH2 cytokine response developed in STAT6 −/− BCL-6 −/− and IL-4 −/− BCL-6 −/− mice after immunization with a conventional antigen in adjuvant. In contrast to these in vivo findings, STAT6 was required for the in vitro differentiation of BCL-6 −/− T cells into TH2 cells. BCL-6, a transcriptional repressor that can bind to the same DNA binding motifs as STAT transcription factors, seems to regulate TH2 responses in vivo by a pathway independent of IL-4 and STAT6.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Microtubule-associated proteins (MAPs) bind to and stabilize microtubules (MTs) both in vitro and in vivo and are thought to regulate MT dynamics during the cell cycle. It is known that p220, a major MAP of Xenopus, is phosphorylated by p34cdc2 kinase as well as MAP kinase in mitotic cells, and that the phosphorylated p220 loses its MT-binding and -stabilizing abilities in vitro. We cloned a full-length cDNA encoding p220, which identified p220 as a Xenopus homologue of MAP4 (XMAP4). To examine the physiological relevance of XMAP4 phosphorylation in vivo, Xenopus A6 cells were transfected with cDNAs encoding wild-type or various XMAP4 mutants fused with a green fluorescent protein. Mutations of serine and threonine residues at p34cdc2 kinase-specific phosphorylation sites to alanine interfered with mitosis-associated reduction in MT affinity of XMAP4, and their overexpression affected chromosome movement during anaphase A. These findings indicated that phosphorylation of XMAP4 (probably by p34cdc2 kinase) is responsible for the decrease in its MT-binding and -stabilizing abilities during mitosis, which are important for chromosome movement during anaphase A.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mutations at position 187 in secreted gelsolin enable aberrant proteolysis at the 172–173 and 243–244 amide bonds, affording the 71-residue amyloidogenic peptide deposited in Familial Amyloidosis of Finnish Type (FAF). Thermodynamic comparisons of two different domain 2 constructs were carried out to study possible effects of the mutations on proteolytic susceptibility. In the construct we consider to be most representative of domain 2 in the context of the full-length protein (134–266), the D187N FAF variant is slightly destabilized relative to wild type (WT) under the conditions of urea denaturation, but exhibits a Tm identical to WT. The D187Y variant is less stable to intermediate urea concentrations and exhibits a Tm that is estimated to be ≈5°C lower than WT (pH 7.4, Ca2+-free). Although the thermodynamic data indicate that the FAF mutations may slightly destabilize domain 2, these changes are probably not sufficient to shift the native to denatured state equilibrium enough to enable the proteolysis leading to FAF. Biophysical data indicate that these two FAF variants may have different native state structures and possibly different pathways of amyloidosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Opitz syndrome (OS) is a human genetic disease characterized by deformities such as cleft palate that are attributable to defects in embryonic development at the midline. Gene mapping has identified OS mutations within a protein called Mid1. Wild-type Mid1 predominantly colocalizes with microtubules, in contrast to mutant versions of Mid1 that appear clustered in the cytosol. Using yeast two-hybrid screening, we found that the α4-subunit of protein phosphatases 2A/4/6 binds Mid1. Epitope-tagged α4 coimmunoprecipitated endogenous or coexpressed Mid1 from COS7 cells, and this required only the conserved C-terminal region of α4. Localization of Mid1 and α4 was influenced by one another in transiently transfected cells. Mid1 could recruit α4 onto microtubules, and high levels of α4 could displace Mid1 into the cytosol. Metabolic 32P labeling of cells showed that Mid1 is a phosphoprotein, and coexpression of full-length α4 decreased Mid1 phosphorylation, indicative of a functional interaction. Association of green fluorescent protein–Mid1 with microtubules in living cells was perturbed by inhibitors of MAP kinase activation. The conclusion is that Mid1 association with microtubules, which seems important for normal midline development, is regulated by dynamic phosphorylation involving MAP kinase and protein phosphatase that is targeted specifically to Mid1 by α4. Human birth defects may result from environmental or genetic disruption of this regulatory cycle.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The leptin receptor (OB-R) is a single membrane-spanning protein that mediates the weight regulatory effects of leptin (OB protein). The mutant allele (db) of the OB-R gene encodes a protein with a truncated cytoplasmic domain that is predicted to be functionally inactive. Several mRNA splice variants encoding OB-Rs with different length cytoplasmic domains have been detected in various tissues. Here we demonstrate that the full-length OB-R (predominantly expressed in the hypothalamus), but not a major naturally occurring truncated form or a mutant from found in db/db mice, can mediate activation of signal transducer and activator of transcription (STAT) proteins and stimulate transcription through interleukin 6 responsive gene elements. Reconstitution experiments suggest that, although OB-R mediates intracellular signals with a specificity similar to interleukin 6-type cytokine receptors, signaling appears to be independent of the gp130 signal transducing component of the interleukin 6-type cytokine receptors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report here on the ability of IDRA 21 and aniracetam, two negative allosteric modulators of glutamate-induced DL-alpha-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) receptor desensitization, to attenuate alprazolam-induced learning deficit in patas monkeys working in a complex behavioral task. In one component of a multiple schedule (repeated acquisition or "learning"), patas monkeys acquired a different four-response chain each session by responding sequentially on three keys in the presence of four discriminative stimuli (geometric forms or numerals). In the other component (performance) the four-response chain was the same each session. The response chain in each component was maintained by food presentation under a fixed-ratio schedule. When alprazolam (0.1 or 0.32 mg/kg p.o.) was administered alone, this full allosteric modulator of gamma-aminobutyric acid type A (GABAA) receptors produced large decreases in the response rate and accuracy in the learning component of the task. IDRA 21 (3 or 5.6 mg/kg p.o.) and aniracetam (30 mg/kg p.o.) administered 60 min before alprazolam, having no effect when given alone, antagonized the large disruptive effects of alprazolam on learning. From dose-response studies, it can be estimated that IDRA 21 is approximately 10-fold more potent than aniracetam in antagonizing alprazolam-induced learning deficit. We conclude that IDRA 21, a chemically unrelated pharmacological congener of aniracetam, improves learning deficit induced in patas monkeys by the increase of GABAergic tone elicited by alprazolam. Very likely IDRA 21 exerts its behavioral effects by antagonizing AMPA receptor desensitization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Neuroblastoma (NB), a tumor arising from the sympathetic nervous system, is one of the most common malignancies in childhood. Several recent reports on the p53 genotype found virtually exclusive wild-type status in primary tumors, and it was postulated that p53 plays no role in the development of NB. Here, however, we report that the vast majority of undifferentiated NBs exhibit abnormal cytoplasmic sequestration of wild-type p53. This inability of p53 to translocate to the nucleus presumably prevents the protein from functioning as a suppressor. Thirty of 31 cases (96%) of undifferentiated NB showed elevated levels of wild-type p53 in the cytoplasm of all tumor cells concomittant with a lack of nuclear staining. p53 immunoprecipitation from tumor tissues showed a 4.5- to 8-fold increase over normal protein levels. All of 10 tumors analyzed harbored wild-type p53 by direct sequencing of full-length cDNA and Southern blot. In addition, no MDM-2 gene amplification was seen in all 11 tumors analyzed. In contrast, no p53 abnormality was detected in 14 differentiated ganglioneuroblastomas and 1 benign ganglioneuroma. We conclude that loss of p53 function seems to play a major role in the tumorigenesis of undifferentiated NB. This tumor might abrogate the transactivating function of p53 by inhibiting its access to the nucleus, rather than by gene mutation. Importantly, our results suggest that (i) this could be a general mechanism for p53 inactivation not limited to breast cancer (where we first described it) and that (ii) it is found in a tumor previously not thought to be affected by p53 alteration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Polímeros de coordenação têm atraído a atenção de pesquisadores na última década por conta de sua incrível versatilidade e virtualmente infinito número de possibilidades de combinação de ligantes orgânicos e centros metálicos. Estes compostos normalmente herdam as características magnéticas, eletrônicas e espectroscópicas de seus componentes base. Entretanto, apesar do crescente número de trabalhos na área, ainda são raros os polímeros de coordenação que apresentem condutividade elétrica. Para este fim, utilizou-se a N,N\'-bis(4-piridil)-1,4,5,8-naftaleno diimida, ou NDI-py, que pertence a uma classe de compostos rígidos, planares, quimicamente e termicamente estáveis e que já foram extensamente estudados por suas propriedades fotoeletroquímicas e semicondução do tipo n. O primeiro polímero de coordenação sintetizado, MOF-CoNDI-py-1, indicou ser um polímero linear, de estrutura 1D. O segundo, MOF-CoNDI-py-2, que conta com ácido tereftálico como ligante suporte, é um sólido cristalino com cela unitária monoclínica pertencente ao grupo espacial C2/c, determinado por difração de raios-X de monocristal. A rede apresenta um arranjo trinuclear de íons Co(II) alto spin com coordenados em uma geometria de octaedro distorcido, enquanto os ligantes NDI-py se encontram em um arranjo paralelo na estrutura, em distâncias apropriadas para transferência eletrônica. Com o auxílio de cálculo teóricos a nível de DFT, foi realizado um estudo aprofundado dos espectros eletrônicos e vibracionais, com atribuição das transições observadas, tanto para o MOF-CoNDI-py-2 quanto para o ligante NDI-py livre. A rede de coordenação absorve em toda a região do espectro eletrônico analisada, de 200 nm a 2500 nm, além de apresentar luminescência com característica do ligante. Dispositivos eletrônicos fabricados com um cristal do MOF-CoNDI-py-2 revelaram condutividades da ordem de 7,9 10-3 S cm -1, a maior já observada para um MOF. Além de elevada, a condutividade elétrica dos cristais demonstrou-se altamente anisotrópica, sendo significativamente menos condutor em algumas direções. Os perfis de corrente versus voltagem foram analisados em termos de mecanismos de condutividade, sendo melhores descritos por um mecanismo limitado pelo eletrodo to tipo Space-Charge Limited Current, concordando com a proposta de condutividade através dos planos de NDI-py na rede. A condutividade dos cristais também é fortemente dependente de luz, apresentando fotocondução quando irradiado por um laser vermelho, de 632 nm, enquanto apresenta um comportamento fotorresistivo frente a uma fonte de luz branca. Estes resultados, combinados, trazem um MOF em uma estrutura incomum e com elevada condutividade elétrica, modulada por luz, em medidas diretas de corrente. Não existem exemplos conhecidos de MOFs na literatura com estas características.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The discovery of very slow pulsations (Pspin =5560 s) has solved the long-standing question of the nature of the compact object in the high-mass X-ray binary 4U 2206+54 but has posed new ones. According to spin evolutionary models in close binary systems, such slow pulsations require a neutron star magnetic field strength larger than the quantum critical value of 4.4 × 1013 G, suggesting the presence of a magnetar. We present the first XMM–Newton observations of 4U 2206+54 and investigate its spin evolution. We find that the observed spin-down rate agrees with the magnetar scenario. We analyse Integral Spacecraft Gamma-Ray Imager (ISGRI)/INTErnational Gamma-RAy Laboratory (INTEGRAL) observations of 4U 2206+54 to search for the previously suggested cyclotron resonance scattering feature at ∼30 keV. We do not find a clear indication of the presence of the line, although certain spectra display shallow dips, not always at 30 keV. The association of these dips with a cyclotron line is very dubious because of its apparent transient nature. We also investigate the energy spectrum of 4U 2206+54 in the energy range 0.3–10 keV with unprecedented detail and report for the first time the detection of very weak 6.5 keV fluorescence iron lines. The photoelectric absorption is consistent with the interstellar value, indicating very small amount of local matter, which would explain the weakness of the florescence lines. The lack of matter locally to the source may be the consequence of the relatively large orbital separation of the two components of the binary. The wind would be too tenuous in the vicinity of the neutron star.