1000 resultados para fluxo em redes
Resumo:
A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).
Resumo:
Manipulation of the flux of substrates was utilized to control the amount of 3-hydroxyvalerate and 3-hydroxy-4-pentenoate produced by Burkohlderia sp. The 3HV production rate was directly proportional to the propionic acid uptake rate with the last one completely directed to 3HV biosynthesis. The 3HPE production rate was inversely proportional to the sucrose uptake rate probably due to operation of the glyoxylate cycle.
Resumo:
El objetivo del presente ensayo es analizar el papel de las nuevas tecnologías en la formación de redes de acción. Para ello, comenzaré analizando brevemente ciertos puntos y características de las redes de acción y sus tipos, para a continuación, centrar el análisis en un caso real y de ardiente actualidad, como es el caso de Birmania.Una red de acción es un sistema que interconecta nodos. Estos nodos son autónomos y autoorganizados, de manera que cada uno de ellos aporta información y la red se encarga de intercambiar dicha información proveniente de los distintos nodos, así como proyectarla hacia espacios mayores de interacción. Por lo tanto, una red es un sistema exógeno, en la medida que trabaja en la búsqueda constante de interacciones e intercambios mas allá de sus propias fronteras. Las redes responden a la necesidad de conversar con otros para producir acuerdos, arreglos y consensos. Por lo que la red precisa de la polivalencia y la capacidad de adquirir nuevas competencias, por parte de los sujetos que la forman.
Resumo:
The adsorption of Cu(II) ions from aqueous solution by chitosan using a column in a closed hydrodynamic flow system is described. The adsorption capacities as a function of contact time of copper(II) ions and chitosan were determined by varying the ionic strength, temperature and the flow of the metal solution. The Langmuir model reproduced the adsorption isothermal data better than the Freundlich model. The experimental kinetic data correlate properly with the second-order kinetic reaction for the whole set of experimental adsorption conditions. The rate constants exercise great influence on the time taken for equilibrium to be established by complexation or electrostatic interaction between the amino groups of chitosan and the metal.
Resumo:
Hasta hace algunos años, el interés por la historia de la familia, aunque no era escaso, estaba orientado a enfoques de tipo macrohistórico, ya que el énfasis estaba puesto en las estructuras de la sociedad. La dominación de los planteamientos cuantitativistas impuestos por los Annales, así como la fuerte influencia del marxismo, coadyuvaron en la consideración de la familia, fio como objeto de investigación en sí misma, sino como expresión o ilustración de un funcionamiento económico social global.
Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo
Resumo:
This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.
Resumo:
In 2009 the University of Girona (Spain) created four interest groups on teaching innovation. The objective of the project is that lecturers with an interest in teaching innovation can exchange their points of view and learn from one another, so University teaching is improved as a result. There are four such groups: “Problem based learning (ABP)”, “Cooperative learning”, “Evaluation”, and “Information and Communication Technologies (ICTs) and Teaching”. The coordinators of the groups or networks, as they are also called, are chosen on a free basis by its members. This paper presents their point of view as regards the current activity of encouragement of interest in higher education and they elaborate on the main difficulties involved. The implications of the interdisciplinary work are explored, as well as the challenges of an initiative of this kind. The evolution of the ongoing work is reviewed, taking into account the context of a changing University, the lack of previous experience regarding projects of this kind, the asynchronous communication among the participants, and the necessity of a flexible approach in organizational matters
Resumo:
A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999). The increase in sensitivity (30.4-fold) in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.
Resumo:
Although several chemical elements were not known by end of the 18th century, Mendeleyev came up with an astonishing achievement: the periodic table of elements. He was not only able to predict the existence of (then) new elements but also to provide accurate estimates of their chemical and physical properties. This is certainly a relevant example of the human intelligence. Here, we intend to shed some light on the following question: Can an artificial intelligence system yield a classification of the elements that resembles, in some sense, the periodic table? To achieve our goal, we have fed a self-organized map (SOM) with information available at Mendeleyev's time. Our results show that similar elements tend to form individual clusters. Thus, SOM generates clusters of halogens, alkaline metals and transition metals that show a similarity with the periodic table of elements.
Resumo:
The first computational implementation that automates the procedures involved in the calculation of infrared intensities using the charge-charge flux-dipole flux model is presented. The atomic charges and dipoles from the Quantum Theory of Atoms in Molecules (QTAIM) model was programmed for Morphy98, Gaussian98 and Gaussian03 programs outputs, but for the ChelpG parameters only the Gaussian programs are supported. Results of illustrative but new calculations for the water, ammonia and methane molecules at the MP2/6-311++G(3d,3p) theoretical level, using the ChelpG and QTAIM/Morphy charges and dipoles are presented. These results showed excellent agreement with analytical results obtained directly at the MP2/6-311++G(3d,3p) level of theory.
Resumo:
A multicommuted method for determination of chlorine in water samples using a 100-cm cell was developed. In this method, orto-Tolidine reacts with chlorine and the product was monitored at 438 nm. The analytical curve for chlorine was linear in concentration range from 1.34x10-6 to 2.01x10-5 mol L-1 with a detection limit of 9.40x10-8 mol L-1. A sampling rate of 45 h-1and a RSD of 1.0 % (n = 15) were obtained. The method was applied with success for chlorine determination in six water samples.
Resumo:
A binary sampling flow analysis system equipped with gas diffusion cell was developed for NH4+ and/or NH2Cl determination in wastewater and disinfection products samples based on the Berthelot reaction of the NH2Cl diffused through the semi-permeable PTFE membrane. The effect of the analytical conditions related to the reaction and flow parameters were evaluated and N-NH4+ and N-NH2Cl were determined in concentration ranges from 0.17 to 5 mg L-1 and from 0.5 to 14.5 mg L-1, respectively. Limits of detection (3σ) of 50 and 140 µg L-1 for N-NH4+ and N-NH2Cl were calculated, respectively, and RSD of 5 and 2% were calculated for 10 consecutive determinations of N-NH4+ (1 and 3 mg L-1) and N-NH2Cl (3 and 9 mg L-1), respectively with 30 determinations h-1.
Resumo:
This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.
Resumo:
A flow injection chemiluminescence method for the determination of paracetamol in pharmaceutical formulations is described. It is based on the consumption of the sodium hypochlorite by paracetamol and decreases of the analytical signal. The analytical curve was linear in the paracetamol concentration range from 5.0 x 10-6 to 5.0 x 10-5 mol L-1, with a detection limit of 1.8 x 10-6 mol L-1. The RSDs were 2.0 and 1.2% respectively for 2.0 x 10-5 and 4.0 x 10-5 mol L-1 paracetamol solutions (n = 10) and a sampling frequency of 180 h-1 was obtained.
Resumo:
The multilayer perceptron network was used to classify the gasoline. The main parameters used in the classification were established by the Ordinance nº 309 of the Agência Nacional do Petróleo, but without informing the network the legal limits of these parameters. The network used had 10 neurons in a single hidden layer, learning rate of 0.04 and 250 training epochs. The application of artificial neural network served classify 100% of the commercialized gas in the region of Londrina-PR and to identify the tampered gasoline even those suspected of tampering.