960 resultados para feed efficiency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two Isocaloric Isoproteic 30% crude protein diets were formulated for Clariid catfish and Tilapia with wheat grain starch (WGS) and cassava tuber starch (CTS) incorporated at 10 percent as binding agents. Saccharomyces cerevisiae was included at 2% as floating additive. The water stability, nutrient retention and flotation of pelleted feeds were observed for 60 minutes. There were generally decreasing trends in stability and retention at increasing time of immersion in water. The lipid retention was higher (P>0.05) than proteins in both diets. WGS diet was better (P>0.05) than CTS diet in flotation, which has attributed to the presence of gluten protein in wheat products. It is envisaged that a break through in floating feed development in Nigeria aquaculture would save the Nigeria economy from extruded (floating) feed importation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

70-day growth trial was conducted with Heteroclarias: Heterobranchus bidorsalis X Clarias gariepinus (mean weight 0.64~c0.006g) fed diets based on various inclusion levels of Maggot Meal. The fishmeal in the control diet was replaced with maggot meals at 25%, 50%, 75% and 100% levels to supply 40% crude protein in the final diets. The trails were conducted in glass tanks (60cmx30cmx30cm). Evaluation of growth parameters and nutrient utilization of the fish was based on weight gains, protein intake, protein efficiency ratio, net protein utilization, feed conversion efficiency and carcass analysis. Best growth and feed conversion efficiency were obtained with the 75% dietary inclusion of maggot meal. There was no significant differences (P>0.055) between the group of fish on 50% and 75% dietary inclusion maggot meal in growth performance and protein efficiency ratio but, there was a significant (P<0.05) difference in the NPU (Net Protein Utilization) and protein gain between the control diet and those fed on maggot meals. There was no marked variation in the survival rate of fish on all diets

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We build a compact high-conversion-efficiency and broadband tunable noncollinear optical parametric amplifier (OPA) in the infra-red (IR) pumped by a femtosecond Ti:sapphire CPA laser. The OPA consists of an internal seed of white-light continuum generator (WLG) and two noncollinear optical parametric amplifiers. The tunable wavelength range is from 1.2 mu m to 2.4 mu m for both signal and idle pulses. The total OPA efficiency in the last OPA stage reaches about 40% in a wider tunable spectral range (from 1.3 mu m to 1.7 mu m for signal pulse, from 1.5 mu m to 2.0 mu m for idle pulse respectively).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

41 p.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

31 p.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While concentrator photovoltaic cells have shown significant improvements in efficiency in the past ten years, once these cells are integrated into concentrating optics, connected to a power conditioning system and deployed in the field, the overall module efficiency drops to only 34 to 36%. This efficiency is impressive compared to conventional flat plate modules, but it is far short of the theoretical limits for solar energy conversion. Designing a system capable of achieving ultra high efficiency of 50% or greater cannot be achieved by refinement and iteration of current design approaches.

This thesis takes a systems approach to designing a photovoltaic system capable of 50% efficient performance using conventional diode-based solar cells. The effort began with an exploration of the limiting efficiency of spectrum splitting ensembles with 2 to 20 sub cells in different electrical configurations. Incorporating realistic non-ideal performance with the computationally simple detailed balance approach resulted in practical limits that are useful to identify specific cell performance requirements. This effort quantified the relative benefit of additional cells and concentration for system efficiency, which will help in designing practical optical systems.

Efforts to improve the quality of the solar cells themselves focused on the development of tunable lattice constant epitaxial templates. Initially intended to enable lattice matched multijunction solar cells, these templates would enable increased flexibility in band gap selection for spectrum splitting ensembles and enhanced radiative quality relative to metamorphic growth. The III-V material family is commonly used for multijunction solar cells both for its high radiative quality and for the ease of integrating multiple band gaps into one monolithic growth. The band gap flexibility is limited by the lattice constant of available growth templates. The virtual substrate consists of a thin III-V film with the desired lattice constant. The film is grown strained on an available wafer substrate, but the thickness is below the dislocation nucleation threshold. By removing the film from the growth substrate, allowing the strain to relax elastically, and bonding it to a supportive handle, a template with the desired lattice constant is formed. Experimental efforts towards this structure and initial proof of concept are presented.

Cells with high radiative quality present the opportunity to recover a large amount of their radiative losses if they are incorporated in an ensemble that couples emission from one cell to another. This effect is well known, but has been explored previously in the context of sub cells that independently operate at their maximum power point. This analysis explicitly accounts for the system interaction and identifies ways to enhance overall performance by operating some cells in an ensemble at voltages that reduce the power converted in the individual cell. Series connected multijunctions, which by their nature facilitate strong optical coupling between sub-cells, are reoptimized with substantial performance benefit.

Photovoltaic efficiency is usually measured relative to a standard incident spectrum to allow comparison between systems. Deployed in the field systems may differ in energy production due to sensitivity to changes in the spectrum. The series connection constraint in particular causes system efficiency to decrease as the incident spectrum deviates from the standard spectral composition. This thesis performs a case study comparing performance of systems over a year at a particular location to identify the energy production penalty caused by series connection relative to independent electrical connection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I

Regression analyses are performed on in vivo hemodialysis data for the transfer of creatinine, urea, uric acid and inorganic phosphate to determine the effects of variations in certain parameters on the efficiency of dialysis with a Kiil dialyzer. In calculating the mass transfer rates across the membrane, the effects of cell-plasma mass transfer kinetics are considered. The concept of the effective permeability coefficient for the red cell membrane is introduced to account for these effects. A discussion of the consequences of neglecting cell-plasma kinetics, as has been done to date in the literature, is presented.

A physical model for the Kiil dialyzer is presented in order to calculate the available membrane area for mass transfer, the linear blood and dialysate velocities, and other variables. The equations used to determine the independent variables of the regression analyses are presented. The potential dependent variables in the analyses are discussed.

Regression analyses were carried out considering overall mass-transfer coefficients, dialysances, relative dialysances, and relative permeabilities for each substance as the dependent variables. The independent variables were linear blood velocity, linear dialysate velocity, the pressure difference across the membrane, the elapsed time of dialysis, the blood hematocrit, and the arterial plasma concentrations of each substance transferred. The resulting correlations are tabulated, presented graphically, and discussed. The implications of these correlations are discussed from the viewpoint of a research investigator and from the viewpoint of patient treatment.

Recommendations for further experimental work are presented.

Part II

The interfacial structure of concurrent air-water flow in a two-inch diameter horizontal tube in the wavy flow regime has been measured using resistance wave gages. The median water depth, r.m.s. wave height, wave frequency, extrema frequency, and wave velocity have been measured as functions of air and water flow rates. Reynolds numbers, Froude numbers, Weber numbers, and bulk velocities for each phase may be calculated from these measurements. No theory for wave formation and propagation available in the literature was sufficient to describe these results.

The water surface level distribution generally is not adequately represented as a stationary Gaussian process. Five types of deviation from the Gaussian process function were noted in this work. The presence of the tube walls and the relatively large interfacial shear stresses precludes the use of simple statistical analyses to describe the interfacial structure. A detailed study of the behavior of individual fluid elements near the interface may be necessary to describe adequately wavy two-phase flow in systems similar to the one used in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental stocking density of Macrobrachium rosenbergii in larval rearing was conducted in A.G. Aqua Hatchery, Chakaria, Bangladesh to study the effect of different stocking densities on growth, survival rate and diseases stress under hatchery condition. The research work was conducted using six cemented rectangular tanks having 3m3 capacity (1.5mX2mX1m) each. Stocking density were maintained in three experimental setup as 200, 150 and 100ind/L of the T1, T2 and T3 respectively with one replicate each. The larvae were fed with Artemia nauplii, Custard, Maxima and brine shrimp flakes. Water quality was maintained by exchanging 20-30% (12ppt saline water) daily. During the study period, temperature, pH, DO, salinity, nitrite-nitrogen, ammonia and alkalinity were maintained from 28.5-31.5ºC, 7.5-7.8, 5.8-5.9mg/L, 12-13ppt, 0.14-0.2 mg/L, 0.22-0.3mg/L, and 140-160mg/L respectively. The growth rates of larvae at 11th stage were recorded in terms of body length 0.115, 0.136, and 0.169 mm/day whereas body weight were observed 0.000115, 0.000180, and 0.000240g/day. The survival rate of larvae were found 21.8%, 30.4% and 51.3% in treatments T1, T2 and T3 respectively. PL was obtained as 43, 45, and 51PL/L and days required of 41, 38 and 34 days in stocking density of 200, 150, and 100ind/L respectively. It was found that the minimum of 34 days was required to attain the PL (12th stage) using the stocking density of 100 individuals/L. Cannibalism, Zoothamnium, Exuvia Entrapment Disease (EED), and Bacterial Necrosis (BN) were found to be the threat to the commercial hatchery operation that might responsible for potential larval damages which can be reduced by lowering the stocking densities in larval rearing tank that also increased the survival and growth rate.