906 resultados para facial morphology
Resumo:
OBJETIVO: Investigar os efeitos morfológicos da exposição crônica à inalação de fumaça do tabaco e o do consumo de álcool nos pulmões e no crescimento de ratos. MÉTODOS: Sessenta ratos Wistar machos foram distribuídos em quatro grupos: controle, tabaco, álcool e tabaco + álcool, e acompanhados por um período de 260 dias. No final do periodo foi realizada análise morfológica dos pulmões por microscopia óptica e eletrônica. O crescimento dos ratos foi investigado através da medição do comprimento focinho-ânus, peso corporal e índice de massa corporal. RESULTADOS: Os três grupos expostos às drogas apresentaram peso e comprimento significativamente menores que os do grupo controle. As percentagens de bronquiolite e alveolite, e o diâmetro alveolar médio foram maiores nos grupos expostos à fumaça do tabaco, mas sem significancia estatística quando comparadas ao grupo controle. A microscopia eletrônica revelou apoptose mais intensa e lesões degenerativas no grupo de fumantes, enquanto lesões degenerativas nos corpos lamelares foram mais intensas com a associação de ambas as drogas. CONCLUSÕES: Este modelo experimental mostrou alterações morfológicas observadas por microscopia eletrônica, principalmente devido à exposição ao tabaco. Tanto o alcool como o tabaco prejudicaram o crescimento dos animais, o tabaco mostrando um efeito maior sobre o comprimento e o álcool sobre o peso corporal.
Resumo:
The hypothyroidism is the most commonly endocrinopathy in dogs, that occurs preferentially in middle-aged pure breed. The clinical signs associated with hypothyroidism are variable, many times non-specific, including metabolical, dermatological or cardiovascular. The main laboratorial findings are non-regenerative anemia and hypercholesterolemia. Hyponatremia, increase on alanine transferase and alkaline phosphatase activity also can be observed in a lower frequency. There are some reports of peripheral neuropathies caused by hypothyroidism, but the pathophysiology of this process is still unknown. There are specific diagnostic tests that can be used to help diagnose hypothyroidism, and those should be aligned together with the animal's clinical symptoms. The thyroxine stimulating hormone, and free and total thyroxine concentrations are the most used tests. A Pit Bull dog, female, over weighted, was treated presenting left facial paralysis. Thyroid function tests confirmed hypothyroidism. The animal was treated with hormonal replacement and there was improvement in clinical signs in 40 days, confirming that hypothyroidism was facial paralysis' cause.
Resumo:
This study describes the influence of incubation temperature during initial development phase on the morphology and muscle growth characteristics in the pacu (Piaractus mesopotamicus). Pacu eggs were incubated at 25, 27, and 29 degreesC until hatching. After day 5, fish from each temperature were transferred to 5001 tanks. At hatching and after 5, 25, and 60 days, muscle samples were collected, some were frozen in liquid nitrogen and others fixed in 4% paraformaldehyde or 2.5% glutaraldehyde. These samples were used for morphological, histochemical, immunohistochemical, and morphometric analysis. At hatching, we observed a superficial monolayer of small diameter fibers, lying just beneath the skin surrounding several round cells. From day 5, we observed two distinct populations of muscle fibers distributed in two layers: (1) red-in a superficial region with aerobic activity, and following acid preincubation, high mATPase activity, and 2) white-with anaerobic activity, and following alkaline preincubation, high mATPase activity. Twenty-five days after hatching, an intermediate layer and cell proliferating zones could be seen in the dorsal fin muscle region, with intermediate characteristics. Throughout the experimental period, there was an increase in muscle mass due to new fiber recruitment in the cell proliferating zones and between the more differentiated fibers in red, intermediate, and white muscles. This was more obvious from day 25, and at 29 degreesC than at 25 and 27 degreesC. Fiber hypertrophy occurred from hatching to 60 days and was more evident from 5 to 25 days. The number of proliferating nuclei (PCNA-labelling) increased from hatching to 60 days, and was more obvious in the 29 degreesC group at 60 days. Our results show that at incubation temperatures of 25, 27 and 29 degreesC, hypertrophy was predominantly from hatching to 25 days, after that muscle growth by hyperplastic mechanism increased. The interaction of muscle hypertrophic and hyperplastic growth processes in the 29 degreesC group produced the largest fish at the end of the experiment. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Mechanisms of testicular thermoregulation, the relationship of scrotal, testicular vascular cone (TVC), and testicular morphology with thermoregulatory capability, and their effects on semen quality and sperm production were studied in 20 Bos indicus, 28 crossbred, and 26 Bos taurus bulls. The ratio of testicular artery length and volume to testicular volume were larger (P < 0.05) in B. indicus and crossbred bulls than in B. taurus bulls (1.03 and 0.94 cm/cm(2). versus 0.48 cm/cm(3); 0.034 and 0.047 ml/cm(3) versus 0.017 ml/cm(3), respectively). Testicular artery wall thickness (average 192.5, 229.0, and 290.0 mum, respectively) and arterial-venous blood distance in the TVC (average 330.5, 373.7, and 609.4 pm, respectively) were smallest in B. indicus, intermediary in crossbred, and greatest in B. taurus bulls (P < 0.05); the proximity between arterial and venous blood was consistent with the estimated decrease in arterial blood temperature after passage through the TVC (5.9, 5.0, and 2.9 degreesC, in B. indicus, crossbred, and B. taurus bulls, respectively). In crossbred and B. taurus bulls, there was a positive top-to-bottom scrotal temperature gradient and a negative testicular subtunic temperature gradient. However, in B. indicus bulls, both scrotal and testicular subtunic temperatures gradients were positive. Differences in the vascular arrangement, characteristics of the artery (e.g. wall thickness) or thickness of the tunica albuginea may have affected the testicular arterial blood and subtunic temperatures in B. indicus bulls. Better testicular thermoregulatory capability was associated with increased scrotal shape (pendulosity), testicular artery length and volume, and top-to-bottom gradient of the distance between the artery wall and the veins in the TVC. Increased semen quality was associated with increased testicular volume and scrotal subcutaneous (SQT) temperature gradient, and with decreased scrotal surface and testicular temperatures. Increased sperm production was associated with increased testicular artery volume, testicular volume, and SQT temperature gradient, and with decreased testicular artery wall thickness, scrotal circumference (SC), and scrotal surface, testicular subtunic, and epididymal temperatures. In conclusion, morphology of the TVC may contribute to the greater resistance of B. indicus bulls to high ambient temperatures by conferring a better testicular blood supply and by facilitating heat transfer between the testicular artery and veins. Testicular thermoregulation was associated with opposing scrotal and testicular subtunic temperatures gradients only in crossbred and B. taurus bulls. Scrotal, TVC, and testicular morphology influence testicular thermoregulatory capability and were associated with differences in semen quality and sperm production. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The Ramsay Hunt syndrome is a rare disease caused by an infection of the geniculate ganglion by the varicella-zoster virus. The main clinical features of the syndrome are as follows: Bell palsy unilateral or bilateral, vesicular eruptions on the ears, ear pain, dizziness, preauricular swelling, tingling, tearing, loss of taste sensation, and nystagmus. We describe a 23-year-old white woman, who presented with facial paralysis on the left side of the face, pain, fever, ear pain, and swelling in the neck and auricular region on the left side. She received appropriate treatment with acyclovir, vitamin B complex, and CMP nucleus. After 30 days after presentation, the patient did not show any signs or symptoms of the syndrome. At follow-up at 1 year, she showed no relapse of the syndrome.
Resumo:
The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.
Resumo:
Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared.Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect.Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted.Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.
Resumo:
Purpose: It is unknown whether different micro gap configurations can cause different pen-implant bone reactions. Therefore, this study sought to compare the peri-implant bone morphologies of two implant systems with different implant-abutment connections. Materials and Methods: Three months after mandibular tooth extractions in six mongrel dogs, two oxidized screw implants with an external-hex connection were inserted (hexed group) on one side, whereas on the contralateral side two grit-blasted screw implants with an internal Morse-taper connection (Morse group) were placed. on each side, one implant was inserted level with the bone (equicrestal) and the second implant was inserted 1.5 mm below the bony crest (subcrestal). Healing abutments were inserted immediately after implant placement. Three months later, the peri-implant bone levels, the first bone-to-implant contact points, and the width and steepness of the peri-implant bone defects were evaluated histometrically. Results: All 24 implants osseointegrated clinically and histologically. No statistically significant differences between the hexed group and Morse group were detected for either the vertical position for peri-implant bone levels (Morse equicrestal -0.16 mm, hexed equicrestal -0.22 mm, Morse subcrestal 1.50 mm, hexed subcrestal 0.94 mm) or for the first bone-to-implant contact points (Morse equicrestal -2.08 mm, hexed equicrestal -0.98 mm, Morse subcrestal -1.26 mm, hexed subcrestal -0.76 mm). For the parameters width (Morse equicrestal -0.15 mm, hexed equicrestal -0.59 mm, Morse subcrestal 0.28 mm, hexed subcrestal -0.70 mm) and steepness (Morse equicrestal 25.27 degree, hexed equicrestal 57.21 degree, Morse subcrestal 15.35 degree, hexed subcrestal 37.97 degree) of the pen-implant defect, highly significant differences were noted between the Morse group and the hexed group. Conclusion: Within the limits of this experiment, it can be concluded that different microgap configurations influence the size and shape of the peri-implant bone defect in nonsubmerged implants placed both at the crest and subcrestally. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:540-547
Resumo:
The matching of the aesthetic, functional, and psychosocial results of a facial deformity may produce devastating effects in its carriers, especially if the lesion is extensive or the treatment is aggressive. Because of this, the objective of the present article was to evaluate patient's satisfaction rating after surgical facial reconstruction or rehabilitation with oral and maxillofacial prosthesis, by means of reviewing the literature.
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially the biocompatibility. This study aimed to evaluate the biocompatibility of maxillofacial silicones in subcutaneous tissue of rats. Thirty Wistar rats received subcutaneous implants of 3 maxillofacial silicone elastomers (LIM 6050, MDX 4-4210, and industrial Silastic 732 RTV). A histomorphometric evaluation was conducted to analyze the biocompatibility of the implants. Eight areas of 60.11 mm(2) from the surgical pieces were analyzed. Mesenchymal cells, eosinophils, and foreign-body giant cells were counted. Data were submitted to analysis of variance and Tukey test. Initially, all implanted materials exhibited an acceptable tissue inflammatory response, with tissue reactions varying from light to moderate. Afterward, a fibrous capsule around the silicone was observed. The silicones used in the current study presented biocompatibility and can be used for implantation in both medical and dental areas. Their prosthetic indication is conditioned to their physical properties. Solid silicone is easier to adapt and does not suffer apparent modifications inside the tissues.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)