936 resultados para diagnostic-accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

New R-matrix calculations of electron impact excitation rates in Ca XV are used to derive theoretical electron density diagnostic emission line intensity ratios involving 2s(2)2p(2)- 2s2p(3) transitions, specifically R-1 = I(208.70 Angstrom)/I(200.98 Angstrom), R-2 = I(181.91 Angstrom)/I(200.98 Angstrom), and R-3 = I(215.38 Angstrom)/I(200.98 Angstrom), for a range of electron temperatures (T-e = 10(6.4)-10(6.8) K) and densities (Ne = 10(9)-10(13) cm(-3)) appropriate to solar coronal plasmas. Electron densities deduced from the observed values of R-1, R-2, and R-3 for several solar flares, measured from spectra obtained with the Naval Research Laboratory's S082A spectrograph on board Skylab, are found to be consistent. In addition, the derived electron densities are in excellent agreement with those determined from line ratios in Ca XVI, which is formed at a similar electron temperature to Ca XV. These results provide some experimental verification for the accuracy of the line ratio calculations, and hence the atomic data on which they are based. A set of eight theoretical Ca XV line ratios involving 2s(2)2p(2)-2s2p(3) transitions in the wavelength range similar to140-216 Angstrom are also found to be in good agreement with those measured from spectra of the TEXT tokamak plasma, for which the electron temperature and density have been independently determined. This provides additional support for the accuracy of the theoretical line ratios and atomic data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Age related macular degeneration (AMD) is a common cause of severe vision loss. Identification of genes involved in AMD will facilitate early detection and ultimately help to identify pathways for treatment for this disorder. The A16,263G mutation in the HEMICENTIN-1 gene produces a non-conservative substitution of arginine for glutamine at codon 5345 which has been implicated in familial AMD. The aim of this study is to develop a rapid diagnostic assay for the detection of this mutation and to evaluate its frequency in a sample of AMD patients. Methods: A primer probe set was designed from exon 104 of the HEMICENTIN-1 gene to differentiate between mutant and wild type alleles. A region spanning the mutation was amplified by PCR using a LightCycler (Roche Diagnostic). The mutation was then detected by melt curve analysis of the hybrid formed between the PCR product and a specific fluorescent probe. The frequency of the mutation within the Northern Ireland population was evaluated by assaying 508 affected AMD patients, 25 possibly affected and 163 controls. Results: This assay clearly discriminates between the A16,263G mutant and wild type HEMICENTIN-1 alleles. The wild type sequence has a single base mismatch with the probe which decreases the stability of the hybrid, resulting in a lower TM (TM=51.27 °C) than that observed for the perfectly matched mutant allele (TM=59.9 °C). The mutant allele was detected in only one of the 696 subjects, an affected AMD patient. Conclusions: We describe a rapid assay for the genotyping of the Gln5345Arg mutation using real-time fluorescence PCR to facilitate rapid processing of samples through combined amplification and detection steps. These characteristics are suitable for a clinical setting where high throughput diagnostic procedures are required. The frequency of this mutation within the Northern Ireland population has been estimated at 0.2%, concurring with previous findings that this mutation is a rare variant associated with AMD. A rapid diagnostic assay will facilitate a reliable and convenient evaluation of the frequency of the Gln5345Arg mutation and its association with AMD within other populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent R-matrix calculations of electron impact excitation rates among the 3s(2)3p(4) levels of Cl II are used to derive the nebular emission-line intensity ratios R-1=I(6161.8 Angstrom)/I(8578.7 Angstrom) and R-2=I(6161.8 Angstrom)/I(9123.6 Angstrom) as a function of electron temperature (T-e) and density (N-e). The ratios are found to be very sensitive to changes in T-e but not N-e for densities lower than 10(5) cm(-3). Hence, they should, in principle, provide excellent optical T-e diagnostics for planetary nebulae. The observed values of R-1 and R-2 for the planetary nebulae NGC 6741 and IC 5117, measured from spectra obtained with the Hamilton echelle spectrograph on the 3 m Shane Telescope, imply temperatures in excellent agreement with those derived from other diagnostic lines formed in the same region of the nebula as [Cl II]. This provides some observational support for the accuracy of the [Cl II] line ratio calculations and hence the atomic data on which they are based. The [Cl II] 8578.7 and 9123.6 Angstrom lines are identified for the first time (to our knowledge) in a high-resolution spectrum of the symbiotic star RR Telescopii, obtained with the University College London Echelle Spectrograph on the 3.9 m Anglo- Australian Telescope. However, the 6161.8 Angstrom feature is unfortunately too weak to be identified in the RR Telescopii observations, consistent with its predicted line strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

R-matrix calculations of electron impact excitation rates among the 2s(2)2p(2) P-3, D-1, S-1, and 2s2p(3) S-5 levels of N II are presented. These results are used in conjunction with other recent calculations of electron impact excitation rates and Einstein A-coefficients for N II to derive the emission-line ratio: ratio diagrams and where (R-1, R-2) (R-1, R-3), where R-1 = I(5756.2 Angstrom)/I(6549.9 + 6585.2 Angstrom), R-2 = I(2143.5 Angstrom)/I(6549.9 + 6585.2 Angstrom), and R-3 = I(2139.7 Angstrom)/I(6549.9 + 658.2 Angstrom), for a range of electron temperatures (T-e = 5000-20,000 K) and electron densities (N-e = 10(2)-10(7) cm(-3)) appropriate to gaseous nebulae. These diagrams should, in principle, allow the simultaneous determination of T-e and N-e from measurements of the [N II] lines in a spectrum. Plasma parameters deduced for a sample of gaseous nebulae, using observational data obtained from ground-based telescopes plus the International Ultraviolet Explorer and Hubble Space Telescope satellites, are found to show generally excellent internal consistency and to be in good agreement with the values of T-e and N-e estimated from other line ratios. These results provide observational support for the accuracy of the theoretical ratios and hence the atomic data adopted in their derivation. Theoretical ratios are also presented for the infrared line pair R-4 = I(122 mum)/I(205 mum), and the usefulness of R-4 as an electron density diagnostic is briefly discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theoretical electron-density-sensitive emission line ratios involving 2s(2)2p(2)-2s2p(3) transitions in Si IX between 223 and 350 Angstrom are presented. A comparison of these with an extensive dataset of solar-active-region, quiet-Sun, subflare and off-limb observations, obtained during rocket flights by the Solar EUV Research Telescope and Spectrograph (SERTS), reveals generally very good agreement between theory and experiment. This provides support for the accuracy of the line- ratio diagnostics, and hence the atomic data on which they are based. In particular, the density-sensitive intensity ratio I (258.10 Angstrom)/ I (349.87 Angstrom) offers an especially promising diagnostic for studies of coronal plasmas, as it involves two reasonably strong emission lines and varies by more than an order of magnitude over the useful density range of 10(9)-10(11) cm(-3). The 2s(2)2p(2) S-1(0) - 2s2p(3) P-1(1) transition at 259.77 Angstrom is very marginally identified for the first time in the SERTS database, although it has previously been detected in solar flare observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have revealed considerable interobserver and intraobserver variation in the histological classification of preinvasive cervical squamous lesions. The aim of the present study was to develop a decision support system (DSS) for the histological interpretation of these lesions. Knowledge and uncertainty were represented in the form of a Bayesian belief network that permitted the storage of diagnostic knowledge and, for a given case, the collection of evidence in a cumulative manner that provided a final probability for the possible diagnostic outcomes. The network comprised 8 diagnostic histological features (evidence nodes) that were each independently linked to the diagnosis (decision node) by a conditional probability matrix. Diagnostic outcomes comprised normal; koilocytosis; and cervical intraepithelial neoplasia (CIN) 1, CIN II, and CIN M. For each evidence feature, a set of images was recorded that represented the full spectrum of change for that feature. The system was designed to be interactive in that the histopathologist was prompted to enter evidence into the network via a specifically designed graphical user interface (i-Path Diagnostics, Belfast, Northern Ireland). Membership functions were used to derive the relative likelihoods for the alternative feature outcomes, the likelihood vector was entered into the network, and the updated diagnostic belief was computed for the diagnostic outcomes and displayed. A cumulative probability graph was generated throughout the diagnostic process and presented on screen. The network was tested on 50 cervical colposcopic biopsy specimens, comprising 10 cases each of normal, koilocytosis, CIN 1, CIN H, and CIN III. These had been preselected by a consultant gynecological pathologist. Using conventional morphological assessment, the cases were classified on 2 separate occasions by 2 consultant and 2 junior pathologists. The cases were also then classified using the DSS on 2 occasions by the 4 pathologists and by 2 medical students with no experience in cervical histology. Interobserver and intraobserver agreement using morphology and using the DSS was calculated with K statistics. Intraobserver reproducibility using conventional unaided diagnosis was reasonably good (kappa range, 0.688 to 0.861), but interobserver agreement was poor (kappa range, 0.347 to 0.747). Using the DSS improved overall reproducibility between individuals. Using the DSS, however, did not enhance the diagnostic performance of junior pathologists when comparing their DSS-based diagnosis against an experienced consultant. However, the generation of a cumulative probability graph also allowed a comparison of individual performance, how individual features were assessed in the same case, and how this contributed to diagnostic disagreement between individuals. Diagnostic features such as nuclear pleomorphism were shown to be particularly problematic and poorly reproducible. DSSs such as this therefore not only have a role to play in enhancing decision making but also in the study of diagnostic protocol, education, self-assessment, and quality control. (C) 2003 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a study comparing absolute K-alpha yield from Ti foils measured with a calibrated system of an X-ray CCD coupled to a curved LiF Von-Hamos crystal spectrometer to the difference in the signals measured simultaneously with two similar photodiodes fitted with two different filters. Our data indicate that a combination of photodiodes with different filters could be developed into an alternative and inexpensive diagnostic for monitoring single shot pulsed emission in a narrow band of X-ray region.