967 resultados para cosmic background radiation
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.
Resumo:
Background: Myotragus balearicus was an endemic bovid from the Balearic Islands (Western Mediterranean) that became extinct around 6,000-4,000 years ago. The Myotragus evolutionary lineage became isolated in the islands most probably at the end of the Messinian crisis, when the desiccation of the Mediterranean ended, in a geological date established at 5.35 Mya. Thus, the sequences of Myotragus could be very valuable for calibrating the mammalian mitochondrial DNA clock and, in particular, the tree of the Caprinae subfamily, to which Myotragus belongs. Results: We have retrieved the complete mitochondrial cytochrome b gene (1,143 base pairs), plus fragments of the mitochondrial 12S gene and the nuclear 28S rDNA multi-copy gene from a well preserved Myotragus subfossil bone. The best resolved phylogenetic trees, obtained with the cytochrome b gene, placed Myotragus in a position basal to the Ovis group. Using the calibration provided by the isolation of Balearic Islands, we calculated that the initial radiation of caprines can be dated at 6.2 ± 0.4 Mya. In addition, alpine and southern chamois, considered until recently the same species, split around 1.6 ± 0.3 Mya, indicating that the two chamois species have been separated much longer than previously thought. Conclusion: Since there are almost no extant endemic mammals in Mediterranean islands, the sequence of the extinct Balearic endemic Myotragus has been crucial for allowing us to use the Messinian crisis calibration point for dating the caprines phylogenetic tree.
Resumo:
Background: In ∼5% of advanced NSCLC tumours, ALK tyrosine kinase is constitutively activated after translocation of ALK. ALK+ NSCLC was shown to be highly sensitive to the first approved ALK inhibitor, crizotinib. However, all pts eventually relapse on crizotinib mainly due to secondary ALK mutations/amplification or CNS metastases. Alectinib is a highly selective, potent, oral next-generation ALK inhibitor. Clinical phase II alectinib data in 46 crizotinib-naïve pts with ALK+ NSCLC reported an objective response rate (ORR) of 93.5% and a 1-year progression-free rate of 83% (95% CI: 68-92) (Inoue et al. J Thorac Oncol 2013). CNS activity was seen: of 14 pts with baseline brain metastasis, 11 had prior CNS radiation, 9 of these experienced CNS and systemic PFS of >12 months; of the 3 pts without prior CNS radiation, 2 were >15 months progression free. Trial design: Randomised, multicentre, phase III, open-label study in pts with treatment-naïve ALK+ advanced, recurrent, or metastatic NSCLC. All pts must provide pretreatment tumour tissue to confirm ALK rearrangement (by IHC). Pts (∼286 from ∼180 centres, ∼30 countries worldwide) will be randomised to alectinib (600mg oral bid, with food) or crizotinib (250mg oral bid, with/without food) until disease progression (PD), unacceptable toxicity, withdrawal of consent, or death. Stratification factors are: ECOG PS (0/1 vs 2), race (Asian vs non-Asian), baseline CNS metastases (yes vs no). Primary endpoint: PFS by investigators (RECIST v1.1). Secondary endpoints: PFS by Independent Review Committee (IRC); ORR; duration of response; OS; safety; pharmacokinetics; quality of life. Additionally, time to CNS progression will be evaluated (MRI) for the first time in a prospective randomised NSCLC trial as a secondary endpoint. Pts with isolated asymptomatic CNS progression will be allowed to continue treatment beyond documented progression until systemic PD and/or symptomatic CNS progression, according to investigator opinion. Time to CNS progression will be retrospectively assessed by the IRC using two separate criteria, RECIST and RANO. Further details: ClinicalTrials.gov (NCT02075840). Disclosure: T.S.K. Mok: Advisory boards: AZ, Roche, Eli Lilly, Merck Serono, Eisai, BMS, AVEO, Pfizer, Taiho, Boehringer Ingelheim, Novartis, GSK Biologicals, Clovis Oncology, Amgen, Janssen, BioMarin; board of directors: IASLC; corporate sponsored research: AZ; M. Perol: Advisory boards: Roche; S.I. Ou: Consulting: Pfizer, Chugai, Genentech Speaker Bureau: Pfizer, Genentech, Boehringer Ingelheim; I. Bara: Employee: F. Hoffmann-La Roche Ltd; V. Henschel: Employee and stock: F. Hoffmann-La Roche Ltd.; D.R. Camidge: Honoraria: Roche/Genentech. All other authors have declared no conflicts of interest.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
Expression control in synthetic genetic circuitry, for example, for construction of sensitive biosensors, is hampered by the lack of DNA parts that maintain ultralow background yet achieve high output upon signal integration by the cells. Here, we demonstrate how placement of auxiliary transcription factor binding sites within a regulatable promoter context can yield an important gain in signal-to-noise output ratios from prokaryotic biosensor circuits. As a proof of principle, we use the arsenite-responsive ArsR repressor protein from Escherichia coli and its cognate operator. Additional ArsR operators placed downstream of its target promoter can act as a transcription roadblock in a distance-dependent manner and reduce background expression of downstream-placed reporter genes. We show that the transcription roadblock functions both in cognate and heterologous promoter contexts. Secondary ArsR operators placed upstream of their promoter can also improve signal-to-noise output while maintaining effector dependency. Importantly, background control can be released through the addition of micromolar concentrations of arsenite. The ArsR-operator system thus provides a flexible system for additional gene expression control, which, given the extreme sensitivity to micrograms per liter effector concentrations, could be applicable in more general contexts.
Resumo:
BACKGROUND: The unique situation of the liver with arterial and venous blood supply and the dependency of the tumor on the arterial blood flow make this organ an ideal target for intrahepatic catheter-based therapies. Main forms of treatment are classical bland embolization (TAE) cutting the blood flow to the tumors, chemoembolization (TACE) inducing high chemotherapy concentration in tumors, and radioembolization (TARE) without embolizing effect but very high local radiation. These different forms of therapies are used in different centers with different protocols. This overview summarizes the different forms of treatment, their indications and protocols, possible side effects, and available data in patients with non-colorectal liver tumors. METHODS: A research in PubMed was performed. Mainly clinical controlled trials were reviewed. The search terms were 'embolization liver', 'TAE', 'chemoembolization liver', 'TACE', 'radioembolization liver', and 'TARE' as well as 'chemosaturation' and 'TACP' in the indications 'breast cancer', 'neuroendocrine', and 'melanoma'. All reported studies were analyzed for impact and reported according to their clinical relevance. RESULTS: The main search criteria revealed the following results: 'embolization liver + breast cancer', 122 results, subgroup clinical trials 16; 'chemoembolization liver + breast cancer', 62 results, subgroup clinical trials 11; 'radioembolization liver + breast cancer', 37 results, subgroup clinical trials 3; 'embolization liver + neuroendocrine', 283 results, subgroup clinical trials 20; 'chemoembolization liver + neuroendocrine', 202 results, subgroup clinical trials 9; 'radioembolization liver + neuroendocrine', 64 results, subgroup clinical trials 9; 'embolization liver + melanoma', 79 results, subgroup clinical trials 15; 'chemoembolization liver + melanoma', 60 results, subgroup clinical trials 14; 'radioembolization liver + melanoma', 18 results, subgroup clinical trials 3. The term 'chemosaturation liver' was tested without indication since only few publications exist and provided us with five results and only one clinical trial. CONCLUSION: Despite many years of clinical use and documented efficacy on intra-arterial treatments of the liver, there are still only a few prospective multicenter trials with many different protocols. To guarantee the future use of these efficacious therapies, especially in the light of many systemic or surgical therapies in the treatment of non-colorectal liver metastases, further large randomized trials and transparent guidelines need to be established.
Resumo:
BACKGROUND: ALK-negative anaplastic large cell lymphoma associated with breast implant (i-ALCL) has been recently recognized as a distinct entity. Among 43 830 lymphomas registered in the French Lymphopath network since 2010, 300 breast lymphomas comprising 25 peripheral T-cell lymphomas (PTCL) were reviewed. Among PTCL, ALK-negative ALCL was the most frequent and all of them were associated with breast implants. PATIENTS AND METHODS: Since 2010, all i-ALCL cases were collected from different institutions through Lymphopath. Immuno-morphologic features, molecular data and clinical outcome of 19 i-ALCLs have been retrospectively analyzed. RESULTS: The median age of the patients was 61 years and the median length between breast implant and i-ALCL was 9 years. Most implants were silicone-filled and textured. Implant removal was performed in 17 out of 19 patients with additional treatment based on mostly CHOP or CHOP-like chemotherapy regimens (n = 10/19) or irradiation (n = 1/19). CHOP alone or ABVD following radiation without implant removal have been given in two patients. The two clinical presentations, i.e. effusion and less frequently tumor mass correlated with distinct histopathologic features: in situ i-ALCL (anaplastic cell proliferation confined to the fibrous capsule) and infiltrative i-ALCL (pleomorphic cells massively infiltrating adjacent tissue with eosinophils and sometimes Reed-Sternberg-like cells mimicking Hodgkin lymphoma). Malignant cells were CD30-positive, showed a variable staining for EMA and were ALK negative. Most cases had a cytotoxic T-cell immunophenotype with variable T-cell antigen loss and pSTAT3 nuclear expression. T-cell receptor genes were clonally rearranged in 13 out of 13 tested cases. After 18 months of median follow-up, the 2-year overall survival for in situ and infiltrative i-ALCL was 100% and 52.5%, respectively. CONCLUSIONS: In situ i-ALCLs have an indolent clinical course and generally remain free of disease after implant removal. However, infiltrative i-ALCLs could have a more aggressive clinical course that might require additional therapy to implant removal.
Resumo:
BACKGROUND AND PURPOSE: Compensation for respiratory motion is needed while administering radiotherapy (RT) to tumors that are moving with respiration to reduce the amount of irradiated normal tissues and potentially decrease radiation-induced collateral damages. The purpose of this study was to test a new ventilation system designed to induce apnea-like suppression of respiratory motion and allow long enough breath hold durations to deliver complex RT. MATERIAL AND METHODS: The High Frequency Percussive Ventilation system was initially tested in a series of 10 volunteers and found to be well tolerated, allowing a median breath hold duration of 11.6min (range 3.9-16.5min). An evaluation of this system was subsequently performed in 4 patients eligible for adjuvant breast 3D conformal RT, for lung stereotactic body RT (SBRT), lung volumetric modulated arc therapy (VMAT), and VMAT for palliative pleural metastases. RESULTS: When compared to free breathing (FB) and maximal inspiration (MI) gating, this Percussion Assisted RT (PART) offered favorable dose distribution profiles in 3 out of the 4 patients tested. PART was applied in these 3 patients with good tolerance, without breaks during the "beam on time period" throughout the overall courses of RT. The mean duration of the apnea-like breath hold that was necessary for delivering all the RT fractions was 7.61min (SD=2.3). CONCLUSIONS: This first clinical implementation of PART was found to be feasible, tolerable and offers new opportunities in the field of RT for suppressing respiratory motion.
Resumo:
BACKGROUND: To compare the prognostic value of different anatomical and functional metabolic parameters determined using [(18)F]FDG-PET/CT with other clinical and pathological prognostic parameters in cervical cancer (CC). METHODS: Thirty-eight patients treated with standard curative doses of chemo-radiotherapy (CRT) underwent pre- and post-therapy [(18)F]FDG-PET/CT. [(18)F]FDG-PET/CT parameters including mean tumor standardized uptake values (SUV), metabolic tumor volume (MTV) and tumor glycolytic volume (TGV) were measured before the start of CRT. The post-treatment tumor metabolic response was evaluated. These parameters were compared to other clinical prognostic factors. Survival curves were estimated by using the Kaplan-Meier method. Cox regression analysis was performed to determine the independent contribution of each prognostic factor. RESULTS: After 37 months of median follow-up (range, 12-106), overall survival (OS) was 71 % [95 % confidence interval (CI), 54-88], disease-free survival (DFS) 61 % [95 % CI, 44-78] and loco-regional control (LRC) 76 % [95 % CI, 62-90]. In univariate analyses the [(18)F]FDG-PET/CT parameters unfavorably influencing OS, DFS and LRC were pre-treatment TGV-cutoff ≥562 (37 vs. 76 %, p = 0.01; 33 vs. 70 %, p = 0.002; and 55 vs. 83 %, p = 0.005, respectively), mean pre-treatment tumor SUV cutoff ≥5 (57 vs. 86 %, p = 0.03; 36 vs. 88 %, p = 0.004; 65 vs. 88 %, p = 0.04, respectively) and a partial tumor metabolic response after treatment (9 vs. 29 %, p = 0.0008; 0 vs. 83 %, p < 0.0001; 22 vs. 96 %, p < 0.0001, respectively). After multivariate analyses a partial tumor metabolic response after treatment remained as an independent prognostic factor unfavorably influencing DFS and LRC (RR 1:7.7, p < 0.0001, and RR 1:22.6, p = 0.0003, respectively) while the pre-treatment TGV-cutoff ≥562 negatively influenced OS and DFS (RR 1:2, p = 0.03, and RR 1:2.75, p = 0.05). CONCLUSIONS: Parameters capturing the pre-treatment glycolytic volume and metabolic activity of [(18)F]FDG-positive disease provide important prognostic information in patients with CC treated with CRT. The post-therapy [(18)F]FDG-PET/CT uptake (partial tumor metabolic response) is predictive of disease outcome.
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center
Resumo:
Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.