780 resultados para clinical assessment tools


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: We investigated the psychometric properties of a short questionnaire for combined assessment of different perceived stress management skills in the general population and tested whether scores relate to physiological stress reactivity. METHODS: For psychometric evaluation, we determined the factor structure of the questionnaire and investigated its measurement invariance in the participant groups and over time in three different independent samples representing the general population (total N=332). Reliability was tested by estimating test-retest reliability, internal consistency, and item reliabilities. We examined convergent and criterion validity using selected criterion variables. For endocrine validation, 35 healthy non-smoking and medication-free men in a laboratory study and 35 male and female employees in a workplace study underwent an acute standardized psychosocial stress task. We assessed stress management skills and measured salivary cortisol before and several times up to 60 min (workplace study) and 120 min (laboratory study) after stress. Potential confounders were controlled. RESULTS: The factor structure of the questionnaire consists of five scales reflecting acceptably distinct stress management skills such as cognitive strategies, use of social support, relaxation strategies, anger regulation, and perception of bodily tension. This factor structure was stable across participant groups and over time. Internal consistencies, item reliabilities, and test-retest reliabilities met established statistical requirements. Convergent and criterion validity were also established. In both endocrine validation studies, higher stress management skills were independently associated with lower cortisol stress reactivity (p's<.029). CONCLUSIONS: Our findings suggest that the questionnaire has good psychometric properties and that it relates to subjective psychological and objective physiological stress indicators. Therefore, the instrument seems a suitable measure for differential assessment of stress management skills in the general population.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any robust quality control program is the determination of significant deviations from standard or baseline conditions, clinicians and vendors often neglect the temporal nature of detector degradation (1). This thesis describes the development and testing of new methods for monitoring detector uniformity. These techniques provide more quantitative, sensitive, and specific feedback to the reviewer so that he or she may be better equipped to identify performance degradation prior to its manifestation in clinical images. The methods exploit the temporal nature of detector degradation and spatially segment distinct regions-of-non-uniformity using multi-resolution decomposition. These techniques were tested on synthetic phantom data using different degradation functions, as well as on experimentally acquired time series floods with induced, progressively worsening defects present within the field-of-view. The sensitivity of conventional, global figures-of-merit for detecting changes in uniformity was evaluated and compared to these new image-space techniques. The image-space algorithms provide a reproducible means of detecting regions-of-non-uniformity prior to any single flood image’s having a NEMA uniformity value in excess of 5%. The sensitivity of these image-space algorithms was found to depend on the size and magnitude of the non-uniformities, as well as on the nature of the cause of the non-uniform region. A trend analysis of the conventional figures-of-merit demonstrated their sensitivity to shifts in detector uniformity. The image-space algorithms are computationally efficient. Therefore, the image-space algorithms should be used concomitantly with the trending of the global figures-of-merit in order to provide the reviewer with a richer assessment of gamma camera detector uniformity characteristics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to develop a GST-based methodology for accurately measuring the degree of transverse isotropy in trabecular bone. Using femoral sub-regions scanned in high-resolution peripheral QCT (HR-pQCT) and clinical-level-resolution QCT, trabecular orientation was evaluated using the mean intercept length (MIL) and the gradient structure tensor (GST) on the HR-pQCT and QCT data, respectively. The influence of local degree of transverse isotropy (DTI) and bone mineral density (BMD) was incorporated into the investigation. In addition, a power based model was derived, rendering a 1:1 relationship between GST and MIL eigenvalues. A specific DTI threshold (DTI thres) was found for each investigated size of region of interest (ROI), above which the estimate of major trabecular direction of the GST deviated no more than 30° from the gold standard MIL in 95% of the remaining ROIs (mean error: 16°). An inverse relationship between ROI size and DTI thres was found for discrete ranges of BMD. A novel methodology has been developed, where transversal isotropic measures of trabecular bone can be obtained from clinical QCT images for a given ROI size, DTI thres and power coefficient. Including DTI may improve future clinical QCT finite-element predictions of bone strength and diagnoses of bone disease.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Life expectancy continuously increases but our society faces age-related conditions. Among musculoskeletal diseases, osteoporosis associated with risk of vertebral fracture and degenerative intervertebral disc (IVD) are painful pathologies responsible for tremendous healthcare costs. Hence, reliable diagnostic tools are necessary to plan a treatment or follow up its efficacy. Yet, radiographic and MRI techniques, respectively clinical standards for evaluation of bone strength and IVD degeneration, are unspecific and not objective. Increasingly used in biomedical engineering, CT-based finite element (FE) models constitute the state-of-art for vertebral strength prediction. However, as non-invasive biomechanical evaluation and personalised FE models of the IVD are not available, rigid boundary conditions (BCs) are applied on the FE models to avoid uncertainties of disc degeneration that might bias the predictions. Moreover, considering the impact of low back pain, the biomechanical status of the IVD is needed as a criterion for early disc degeneration. Thus, the first FE study focuses on two rigid BCs applied on the vertebral bodies during compression test of cadaver vertebral bodies, vertebral sections and PMMA embedding. The second FE study highlights the large influence of the intervertebral disc’s compliance on the vertebral strength, damage distribution and its initiation. The third study introduces a new protocol for normalisation of the IVD stiffness in compression, torsion and bending using MRI-based data to account for its morphology. In the last study, a new criterion (Otsu threshold) for disc degeneration based on quantitative MRI data (axial T2 map) is proposed. The results show that vertebral strength and damage distribution computed with rigid BCs are identical. Yet, large discrepancies in strength and damage localisation were observed when the vertebral bodies were loaded via IVDs. The normalisation protocol attenuated the effect of geometry on the IVD stiffnesses without complete suppression. Finally, the Otsu threshold computed in the posterior part of annulus fibrosus was related to the disc biomechanics and meet objectivity and simplicity required for a clinical application. In conclusion, the stiffness normalisation protocol necessary for consistent IVD comparisons and the relation found between degeneration, mechanical response of the IVD and Otsu threshold lead the way for non-invasive evaluation biomechanical status of the IVD. As the FE prediction of vertebral strength is largely influenced by the IVD conditions, this data could also improve the future FE models of osteoporotic vertebra.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SPs’ performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Project description SP trainers from five medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). Outcome High quality of SPs’ patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. For example, the rate of completely correct reaction in medical tests increased from 88% to 95%. Together with 4% of sufficient performances these 95% add up to 99% of the reactions in medical tests meeting the standards of the exam. SP educators using the instrument reported an augmentation of SPs’ performance induced by the use of the instrument. Disadvantages mentioned were the high concentration needed to observe all criteria and the cumbersome handling of the paper-based forms. Discussion We were able to document a very high quality of SP performance in our exam. The data also indicates that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed enhancement of performance. The development of an iPad-based application for the form is planned to address the cumbersome handling of the paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Tumor necrosis factor (TNF) inhibition is central to the therapy of inflammatory bowel diseases (IBD). However, loss of response (LOR) is frequent and additional tests to help decision making with costly anti-TNF Therapy are needed. Methods Consecutive IBD Patients receiving anti-TNF therapy (Infliximab (IFX) or Adalimumab (after IFX LOR) from Bern University Hospital were identified and followed prospectively. Patient whole blood was stimulated with a dose-titration of two triggers of TLR receptors human: TNF and LPS. Median fluorescence intensity of CD62L on the surface of granulocytes was quantified by surface staining with specific antibodies (CD33, CD62L) and flow cytometry and logistic curves to these data permits the calculation of EC50 or the half maximal effective concentration TNF concentration to induce shedding [1]. A shift in the concentration were CD62L shedding occurred was seen before and after the anti-TNF agent administraion which permits to predict the response to the drug. This predicted response was correlated to the clinical evolution of the patients in order to analyze the ability of this test to identify LOR to IFX. Results We collected prospective clinical data and blood samples, before and after anti-TNF agent administration, on 33 IBD patients, 25 Crohn's disease and 8 ulcerative colitis patients (45% females) between June 2012 and November 2013. The assay showed a functional blockade of IFX (PFR) for 22 patients (17 CD and 5 UC) whereas 11 (8 CD and 3 UC) had no functional response (NR) to IFX. Clinical characteristics (e.g. diagnosis, disease location, smoking status, BMI and number of infusions) were no significantly different between predicted PFR and NR. Among the 22 Patients with PRF, only 1 patient was a clinical non responder (LOR to IFX), based on clinical prospective evaluation by IBD gastroenterologists (PJ, AM), and among the 11 predicted NR, 3 had no clinical LOR. Sensitivity of this test was 95% and specificity 73% and AUC adjusted for age and gender was 0.81 (Figure 1). During follow up (median 10 mo, 3–15) 8 “hard” outcomes occured (3 medic. flares, 4 resections and 1 new fistula) 2 in the PFR and 6 in the NR group (25% vs. 75%; p < 0.01). Correlation with clinical response is presented in Figure 2. Figure 1. Figure 2. Correlation clinical response - log EC50 changes: 1 No, 2 partial, 3 complete clinical response. Conclusion CD62L (L-Selectin) shedding is the first validated test of functional blockade of TNF alpha in anti-TNF treated IBD patients and will be a useful tool to guide medical decision on the use of anti-TNF agents. Comparative studies with ATI and trough level of IFX are ongoing. 1. Nicola Patuto, Emma Slack, Frank Seibold and Andrew J. Macpherson, (2011), Quantitating Anti-TNF Functionality to Inform Dosing and Choice of Therapy, Gastroenterology, 140 (5, Suppl. I), S689.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CONTEXT Radiolabelled choline positron emission tomography has changed the management of prostate cancer patients. However, new emerging radiopharmaceutical agents, like radiolabelled prostate specific membrane antigen, and new promising hybrid imaging will begin new challenges in the diagnostic field. OBJECTIVE The continuous evolution in nuclear medicine has led to the improvement in the detection of recurrent prostate cancer (PCa), particularly distant metastases. New horizons have been opened for radiolabelled choline positron emission tomography (PET)/computed tomography (CT) as a guide for salvage therapy or for the assessment of systemic therapies. In addition, new tracers and imaging tools have been recently tested, providing important information for the management of PCa patients. Herein we discuss: (1) the available evidence in literature on radiolabelled choline PET and their recent indications, (2) the role of alternative radiopharmaceutical agents, and (3) the advantages of a recent hybrid imaging device (PET/magnetic resonance imaging) in PCa. EVIDENCE ACQUISITION Data from recently published (2010-2015), original articles concerning the role of choline PET/CT, new emerging radiotracers, and a new imaging device are analysed. This review is reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. EVIDENCE SYNTHESIS In the restaging phase, the detection rate of choline PET varies between 4% and 97%, mainly depending on the site of recurrence and prostate-specific antigen levels. Both 68gallium (68Ga)-prostate specific membrane antigen and 18F-fluciclovine are shown to be more accurate in the detection of recurrent disease as compared with radiolabelled choline PET/CT. Particularly, Ga68-PSMA has a detection rate of 50% and 68%, respectively for prostate-specific antigen levels < 0.5ng/ml and 0.5-2ng/ml. Moreover, 68Ga- PSMA PET/magnetic resonance imaging demonstrated a particularly higher accuracy in detecting PCa than PET/CT. New tracers, such as radiolabelled bombesin or urokinase-type plasminogen activator receptor, are promising, but few data in clinical practice are available today. CONCLUSIONS Some limitations emerge from the published papers, both for radiolabelled choline PET/CT and also for new radiopharmaceutical agents. Efforts are still needed to enhance the impact of published data in the world of oncology, in particular when new radiopharmaceuticals are introduced into the clinical arena. PATIENT SUMMARY In the present review, the authors summarise the last evidences in clinical practice for the assessment of prostate cancer, by using nuclear medicine modalities, like positron emission tomography/computed tomography and positron emission tomography/magnetic resonance imaging.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: It is yet unclear if there are differences between using electronic key feature problems (KFPs) or electronic case-based multiple choice questions (cbMCQ) for the assessment of clinical decision making. Summary of Work: Fifth year medical students were exposed to clerkships which ended with a summative exam. Assessment of knowledge per exam was done by 6-9 KFPs, 9-20 cbMCQ and 9-28 MC questions. Each KFP consisted of a case vignette and three key features (KF) using “long menu” as question format. We sought students’ perceptions of the KFPs and cbMCQs in focus groups (n of students=39). Furthermore statistical data of 11 exams (n of students=377) concerning the KFPs and (cb)MCQs were compared. Summary of Results: The analysis of the focus groups resulted in four themes reflecting students’ perceptions of KFPs and their comparison with (cb)MCQ: KFPs were perceived as (i) more realistic, (ii) more difficult, (iii) more motivating for the intense study of clinical reasoning than (cb)MCQ and (iv) showed an overall good acceptance when some preconditions are taken into account. The statistical analysis revealed that there was no difference in difficulty; however KFP showed a higher discrimination and reliability (G-coefficient) even when corrected for testing times. Correlation of the different exam parts was intermediate. Conclusions: Students perceived the KFPs as more motivating for the study of clinical reasoning. Statistically KFPs showed a higher discrimination and higher reliability than cbMCQs. Take-home messages: Including KFPs with long menu questions into summative clerkship exams seems to offer positive educational effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relationship was explored between a subjective measure of hearing status, derived from a functional self-assessment expressed in terms of ability to hear and understand spoken words, and a comparable objective measure of hearing status, obtained from a speech reception test. The Augmentation Survey of the Health and Nutrition Examination Survey of the National Center for Health Statistics provided the necessary data for a sample of 3059 adults. Using chi-square tests for the subsample with the highest level of objectively assessed hearing status, favorable subjective assessments were found to be significantly associated with higher income, lower age group, higher level of educational attainment, greater psychological adjustment, fewer symptoms of depression, and higher self-ratings of overall health. In a linear regression with self-assessment of hearing status as the dependent variable, less than one-quarter of the variation could be explained by objective status and the six explanatory variables.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Training and assessment paradigms for laparoscopic surgical skills are evolving from traditional mentor–trainee tutorship towards structured, more objective and safer programs. Accreditation of surgeons requires reaching a consensus on metrics and tasks used to assess surgeons’ psychomotor skills. Ongoing development of tracking systems and software solutions has allowed for the expansion of novel training and assessment means in laparoscopy. The current challenge is to adapt and include these systems within training programs, and to exploit their possibilities for evaluation purposes. This paper describes the state of the art in research on measuring and assessing psychomotor laparoscopic skills. It gives an overview on tracking systems as well as on metrics and advanced statistical and machine learning techniques employed for evaluation purposes. The later ones have a potential to be used as an aid in deciding on the surgical competence level, which is an important aspect when accreditation of the surgeons in particular, and patient safety in general, are considered. The prospective of these methods and tools make them complementary means for surgical assessment of motor skills, especially in the early stages of training. Successful examples such as the Fundamentals of Laparoscopic Surgery should help drive a paradigm change to structured curricula based on objective parameters. These may improve the accreditation of new surgeons, as well as optimize their already overloaded training schedules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Incoming students in the University have education deficiencies, so universities studies require a sound basis of scientific knowledge. In this project are analysed instruments to reinforcing knowledge in those areas related to the studies that students are about to embark on public Spanish universities. There are important differences among universities and, in each university there are great differences among titles. Initial courses (cursos cero) are widespread (in 50% of universities) that selfevaluation instruments (14 % of universities). It is necessary to improve diffusion of those instruments because it is not possible to evaluate them. So are proposed the next actuations: to make regular standard surveys for professors and students; to publish results of surveys; public universities should institutionalize their basic training offer and improve the dissemination of this offer especially through the web. This paper presents a questionnaire to assess student opinion about these tools. To analyze the effectiveness, and make an initial estimate of the evaluation of these tools, we conducted a pilot test of the questionnaire with 68 students at the University of Extremadura. The results of preliminary statistical analysis conducted on the pilot test indicate that the survey results are reliable. A global evaluation of both tools, with a scale of 1 to 5, gave an average score of 3.29 for initial courses and 3.41 for selfevaluation. The 72.9% of the students consider the "self assessment" more effective than the "initial course"

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An important objective of the INTEGRATE project1 is to build tools that support the efficient execution of post-genomic multi-centric clinical trials in breast cancer, which includes the automatic assessment of the eligibility of patients for available trials. The population suited to be enrolled in a trial is described by a set of free-text eligibility criteria that are both syntactically and semantically complex. At the same time, the assessment of the eligibility of a patient for a trial requires the (machineprocessable) understanding of the semantics of the eligibility criteria in order to further evaluate if the patient data available for example in the hospital EHR satisfies these criteria. This paper presents an analysis of the semantics of the clinical trial eligibility criteria based on relevant medical ontologies in the clinical research domain: SNOMED-CT, LOINC, MedDRA. We detect subsets of these widely-adopted ontologies that characterize the semantics of the eligibility criteria of trials in various clinical domains and compare these sets. Next, we evaluate the occurrence frequency of the concepts in the concrete case of breast cancer (which is our first application domain) in order to provide meaningful priorities for the task of binding/mapping these ontology concepts to the actual patient data. We further assess the effort required to extend our approach to new domains in terms of additional semantic mappings that need to be developed.