989 resultados para charged aerosols


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Thesis submitted for the co-tutelle degree of Doctor in Physics at Universidade Nova de Lisboa and Université Pierre et Marie Curie

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this research was to evaluate the prevalence of Sthaphylococcus spp. and S. aureus in the odontological clinic environment (air), their production of beta-lactamase and antibacterial susceptibility to the major antibiotics utilized in medical particle. During 12 months of samples collect were isolated 9775 CFU by MSA medium suggesting a high amount of Staphylococcus spp. in the clinic environment which can appear through aerosols. A total of 3149 colonies (32.2%) were suggestive of pathogenic staphylococci. Gram coloration, catalase test, colony-mallow growing on chromogenic medium, and coagulase test confirmed the identity of 44 (0.45%) S. aureus isolates. Of these, 35 isolates (79.5%) showed production of beta-lactamase by CefinaseTM discs and resistance to ampicillin, erythromycin (7 isolates) and tetracycline (1 isolate) suggesting the existence of multiresistant isolates. The evaluation of the oxacillin MIC by Etest® assays showed susceptibility patterns suggesting the inexistence of the mecA gene in chromosomal DNA. These results point out to the need of a larger knowledge on the contamination means and propagation of this microorganism into the odontological clinic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sectorization means dividing a set of basic units into sectors or parts, a procedure that occurs in several contexts, such as political, health and school districting, social networks and sales territory or airspace assignment, to achieve some goal or to facilitate an activity. This presentation will focus on three main issues: Measures, a new approach to sectorization problems and an application in waste collection. When designing or comparing sectors different characteristics are usually taken into account. Some are commonly used, and they are related to the concepts of contiguity, equilibrium and compactness. These fundamental characteristics will be addressed, by defining new generic measures and by proposing a new measure, desirability, connected with the idea of preference. A new approach to sectorization inspired in Coulomb’s Law, which establishes a relation of force between electrically charged points, will be proposed. A charged point represents a small region with specific characteristics/values creating relations of attraction/repulsion with the others (two by two), proportional to the charges and inversely proportional to their distance. Finally, a real case about sectorization and vehicle routing in solid waste collection will be mentioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hantavirus cardiopulmonary syndrome (HCPS) is an infectious disease caused by hantaviruses of the family Bunyaviridae, and is transmitted by aerosols of excreta of infected rodents. The aim of the present study was to determine antibody levels to hantavirus in the population that lives at frontier of Brazil and Argentina. Participated of the study 405 individuals living in the municipalities of Bandeirante, Santa Helena, Princesa and Tunapolis, state of Santa Catarina, Brazil. IgG antibodies to hantavirus were analyzed in sera by an ELISA that uses a recombinant N protein of Araraquara hantavirus as antigen. The results were also confirmed by immunofluorescent test. Eight individuals showed antibodies to hantavirus (1.97% positivity), with serum titers ranging from 100 to 800. Six seropositives were males, older than 30 years and farmers. Our results reinforce previous data on hantavirus circulation and human infections in the southern border of Brazil with Argentina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A thesis submitted for the degree of Ph. D. in Physics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - A legionella em meio hospitalar tem sido alvo de preocupação e de várias discussões, sendo esta uma bactéria patogénica que coloniza vários tipos de ambientes aquáticos (naturais e artificiais). Estas bactérias têm a particularidade de se desenvolver em meio aquático mas a infeção apenas é transmitida através de aerossóis de água contaminada, ou seja, por via aérea. Não se transmitindo de pessoa para pessoa. Pelas suas características os sistemas de arrefecimento de ar, nomeadamente as torres de arrefecimento, condensadores evaporativos, humidificadores e sistemas de ar condicionado, são fontes importantes de disseminação da legionella. Assim surge a necessidade da existência de programas de prevenção, que deverão ter em conta uma adequada manutenção, limpeza e desinfeção. Dada a quantidade de frequentadores assim como da especificidade dos mesmos, em meio hospitalar é particularmente importante a eficácia destes sistemas. Ou seja, os sistemas de arrefecimento em hospitais devem, para além de garantir o conforto térmico, ser responsáveis por manter a qualidade do ar e reduzir os riscos existentes a ele associados. O presente estudo pretende conhecer a verdadeira eficácia dos programas de manutenção e vigilância da Legionella, apenas nos sistemas de arrefecimento. Trata-se então de um estudo exploratório, descritivo recolha desta informação in-loco dos sistemas em estudo, de X hospitais da cidade de Lisboa. Na metodologia serão utilizadas grelhas de observação e resultados de colheita de água dos locais de maior risco. A realização deste estudo visa obter um retrato do panorama existente e contribuir para o início de novos estudos epidemiológicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Doctorate in Biology, Specialty in Biotechnology