854 resultados para balloon embolization
Resumo:
The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). METHODS: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. RESULTS: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. CONCLUSIONS: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.
Resumo:
OBJECTIVE: The Ross operation remains a controversially discussed procedure, because concern exists regarding late dilatation of the neoaortic root and progressive regurgitation of the autograft valve. We present our early experience with an external reinforcement of the autograft, which is inserted into a prosthetic Dacron graft with an artificial aortic root configuration. This detail should help to prevent neoaortic root dilatation. PATIENTS AND METHODS: Between 2006 and 2007, 12 patients (mean age 16 +/- 38 years; range 15-38 years) underwent a Ross procedure by this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 5), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 9 patients. Balloon valvuloplasty had been performed in 7 patients. Follow-up was performed by clinical and echocardiographic examinations. RESULTS: No early or late deaths occurred in this small series, and freedom from reoperation is 100%. Echocardiographic follow-up confirmed absence of aortic insufficiency in 11 patients after a mean of 11 months (range 2-30 months). In 1 patient, a small asymmetric regurgitation jet was already observed at discharge echocardiography. As expected, no neoaortic root dilatation was observed during follow-up. All patients are in New York Heart Association class I. CONCLUSIONS: The present technique is a simple and reproducible technical step that does not require significant additional time. Inclusion of the autograft within a root prosthesis may be especially indicated in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement.
Resumo:
STUDY DESIGN: In vitro testing of vertebroplasty techniques including pulsed jet-lavage for fat and marrow removal in human cadaveric lumbar and thoracic vertebrae. OBJECTIVE: To develop jet-lavage techniques for vertebroplasty and investigate their effect on cement distribution, injection forces, and fat embolism. SUMMARY OF BACKGROUND DATA: The main complications of cement vertebroplasty are cement leakage and pulmonary fat embolism, which can have fatal consequences and are difficult to prevent reliably by current vertebroplasty techniques. METHODS: Twenty-four vertebrae (Th8-L04) from 5 osteoporotic cadaver spines were grouped in triplets depending on bone mineral density (BMD). Before polymethylmethacrylate (PMMA) vertebroplasty, a pulsatile jet-lavage for removal of intertrabecular fat and bone marrow was performed in 2 groups with 8 specimens each, performing radial and axial irrigation from the biopsy needles. One hundred mL of Ringer solution were injected through 1 pedicle and regained by low vacuum via the contralateral pedicle. Eight control vertebrae were not irrigated. All specimens underwent standardized PMMA cement augmentation injecting 20% of the vertebral volume. Injection forces, cement distribution, and extravasations were quantified. RESULTS: All irrigation solution could be retrieved with the vacuum applied. A Kruskal-Wallis test revealed significantly higher injection forces of the control group as compared with the irrigated groups (P = 0.021). Dilatation of the syringe at forces above 300 N occurred in 75% of the untreated compared with 12.5% of the lavaged specimens. CT distribution analysis showed more homogenous cement distribution of the cement and significantly less extravasation in the irrigated specimens. CONCLUSION: The developed lavage technique for vertebroplasty showed to be feasible and reproducible. The reduction of injection forces would allow the use of more viscous PMMA cement lowering the risk for cement embolization and results in a safer procedure. The wash-out of bone marrow and the possible reduction of pulmonary fat embolism have to be verified with in vivo models.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate, in relation to intraoperative estimated blood loss (EBL), the effectiveness of preoperative transcatheter arterial embolization of hypervascular osseous metastatic lesions before orthopedic resection and stabilization. MATERIALS AND METHODS: Between June 1987 and November 2007, 22 patients underwent transcatheter arterial embolization of tumors of the long bone, hip, or vertebrae before resection and stabilization. Osseous metastatic lesions from renal cell carcinoma, malignant melanoma, leiomyosarcoma, and prostate cancer were embolized. All patients were treated with a coaxial catheter technique with polyvinyl alcohol (PVA) particles alone or a combination of PVA particles and coils. After embolization, each tumor was angiographically graded according to devascularization (grades 1-3) based on tumor blush after contrast injection into the main tumor-feeding arteries. RESULTS: In patients with complete devascularization (grade 1), mean EBL was calculated to be 1,119 mL, whereas in patients with partial embolization (grades 2 and 3) EBL was 1,788 mL and 2,500 mL. With respect to intraoperative EBL, no significant difference between devascularization grades was found (p > 0.05). Moderate correlation (r = 0.51, p = 0.019) was observed between intraoperative EBL and tumor size before embolization. Only low correlation (r = 0.44, p = 0.046) was found between intraoperative EBL and operating time. Major complications included transient palsy of the sciatic nerve and gluteal abscess in one patient. CONCLUSION: The results of this study support the concept that there is no statistically significant difference among amounts of intraoperative EBL with varying degrees of embolization.
Resumo:
Background: Classical Roux-en-Y gastric bypass (cRYGB) is a combined restrictive and slightly malabsorptive operation. Excess-BMI-loss (EBMIL) in cRYGB is ~60%, but is diminished for super obese patients (BMI > 50 kg/m2). We therefore designed a modified, mainly malabsorptive distal RYGB (dRYGB). Methods: We report mid-term results after 77 consecutive dRYGB in which malabsorption is inversely related to the length of the common channel. The common channel was 100–150 cm long depending on preoperative BMI, the biliopancreatic limb was 100 cm long, which left >>250 cm for the alimentary channel. To avoid the potentially dangerous combination of malabsorption with sustained restriction the pouch size was increased to ~50ml and a 25 mm circular stapler was used for the gastro-jejunostomy. Results: 33 open and later on 44 laparoscopic interventions have been performed. Median preoperative BMI was 50.2 kg/m 2. No severe intraoperative complications have been observed and no anastomotic leakage was noted in the postoperative period. 5 patients needed balloon dilation of an anastomotic stricture. 3 marginal ulcers occurred at the gastrojejunostomy. The 54 patients with a follow-up time of over 12 months (median 24 months) showed an overall median BMI-reduction of 17 to an actual median BMI of 31.6 kg/m2, corresponding to a EBMIL of 74.5%. Obesity-related comorbid conditions were significantly reduced or cured. Intermittent diarrhea or steatorrhea in 12 patients was easily treated by pancreatic enzyme supplementation. Conclusion: dRYGB is technically more demanding than cRYGB, but shows excellent results in terms of weight-loss and therefore also in reduction of comorbidity especially in super-obese patients. Measuring all three limb lengths allows for a calibration of the malabsorption. The quality of food-intake being important to (super-) obese patients in terms of quality of life, a less restrictive pouch seems more adapted to them. Lifelong multidisciplinary follow-up is mandatory.
Resumo:
Severe peripartum hemorrhage (PPH) contributes to maternal morbidity and mortality and is one of the most frequent emergencies in obstetrics, occurring at a prevalence of 0.5-5.0%. Detection of antepartum risk factors is essential in order to implement preventive measures. Proper training of obstetric staff and publication of recommendations and guidelines can effectively reduce the frequency of PPH and its resulting morbidity and mortality. Therefore, an interdisciplinary expert committee was formed, with members from Germany, Austria, and Switzerland, to summarize recent scientific findings. An up-to-date presentation of the importance of embolization and of the diagnosis of coagulopathy in PPH is provided. Furthermore, the committee recommends changes in the management of PPH including new surgical options and the off-label use of recombinant factor VIIa.
Resumo:
We describe a case of massive embolization of atherosclerotic material during aortic cannulation and the surgical approach chosen to treat it, that is, retrograde cerebral perfusion and subtotal arch replacement in deep hypothermic circulatory arrest.
Resumo:
BACKGROUND: Complete arterial CABG is a surgical option to improve long-term results in the treatment of coronary artery disease (CAD). Harvesting of multiple arterial grafts is commonly associated with prolonged operating times and increased trauma. By use of new operative techniques (skeletonized grafts and the T-graft approach), CABG in multivessel CAD is now possible with only 2 grafts. We present our experience in the use of these techniques on a routine basis. METHODS AND RESULTS: Between March 1996 and September 1999, 490 patients (aged 61+/-9 years, 20% female) underwent complete arterial CABG. Left ventricular ejection fraction ranged from 15% to 85% (mean 59+/-15%). Triple-vessel disease was present in 88% of the patients. The incidence of diabetes mellitus was 32% (14% insulin dependent). Either both internal thoracic arteries (ITAs) (23%) or the left ITA and radial artery (77%) were used as conduits. In 85% of the patients, a T graft was created. Mean operating time was 198+/-46 minutes; bypass time, 82+/-25 minutes; and ischemic time, 58+/-22 minutes. Two to 7 (mean 4.1+/-0.9) anastomoses were performed per patient. Perioperative intra-aortic balloon pump was necessary in 12 patients (2.4%). The rate of perioperative myocardial infarction was 1.2%. Sternal complications occurred in 1. 0%, and in-hospital mortality was 2.2%. Postoperative coronary angiography in 172 patients (35%) documented excellent patency rates (left ITA 98.3%, right ITA 96.5%, and radial artery 96.6%). CONCLUSIONS: Complete arterial revascularization in multivessel CAD is possible with the use of only 2 grafts with good perioperative results. This approach allows for complete arterial CABG on a routine basis.
Resumo:
BACKGROUND: During orthopedic surgery, embolization of bone marrow fat can lead to potentially fatal, intra-operative cardiovascular deterioration. Vasoactive mediators may also be released from the bone marrow and contribute to these changes. Increased plasma levels of endothelin-1 (ET-1) have been observed after pulmonary air and thrombo-embolism. The role of ET-1 in the development of acute cardiovascular deterioration as a result of bone marrow fat embolization during vertebroplasty was therefore investigated. METHODS: Bone cement was injected into three lumbar vertebrae of six sheep in order to force bone marrow fat into the circulation. Invasive blood pressures and heart rate were recorded continuously until 60 min after the last injection. Cardiac output, arterial and mixed venous blood gas parameters and plasma ET-1 concentrations were measured at selected time points. Post-mortem, lung biopsies were taken for analysis of intravascular fat. RESULTS: Cement injections resulted in a sudden (within 1 min) and severe increase in pulmonary arterial pressure (>100%). Plasma concentrations of ET-1 started to increase after the second injection, but no significant changes were observed. Intravascular fat and bone marrow cells were present in all lung lobes. CONCLUSION: Cement injections into vertebral bodies elicited fat embolism resulting in subsequent cardiovascular changes that were characterized by an increase in pulmonary arterial pressure. Cardiovascular complications as a result of bone marrow fat embolism should thus be considered in patients undergoing vertebroplasty. No significant changes in ET-1 plasma values were observed. Thus, ET-1 did not contribute to the acute cardiovascular changes after fat embolism.
Resumo:
In industrial countries, cardiovascular diseases remain the primary cause of death. This review summarizes the role of percutaneous coronary interventions (PCI) in the treatment of coronary heart disease. Interventional therapy of coronary artery disease was initiated in 1977 with the introduction of balloon angioplasty by Andreas Grüntzig in Zurich. Technical progress since has been related to construction and materials of catheters, but also to digital processing of x-ray imaging. Additional methods - rotablation, atherectomy, laser, intravascular ultrasound, and most importantly stent implantation were developed. Only stents significantly changed the procedure. They are today an integral part of PCI.
Resumo:
AIMS: Currently available devices for transcatheter closure of patent foramen ovale (PFO) which rely on a permanent implant have limitations, including late complications. The study objective was to evaluate the safety, feasibility, and effectiveness of the PFx Closure System, the first transcatheter technique for PFO closure without an implantable device. METHODS AND RESULTS: A prospective study of 144 patients was conducted at nine clinical sites from October 2005 through August 2007. All patients had a history of cryptogenic stroke, transient ischemic attack, migraines, or decompression illness. The mean balloon stretched diameter of the PFO was 7.9 +/- 2.5 mm. Technical success (successful application of radiofrequency energy) was achieved in 130 patients. One patient required a transfusion as a result of blood loss during the procedure. There were no other major procedural complications. There were no recurrent strokes, deaths, conduction abnormalities, or perforations following the procedure. At a mean follow-up of 6 months, successful closure was achieved in 79 patients (55%). In PFOs with balloon sized or stretched diameters less than 8 mm, the closure rate was 72% (53/74). CONCLUSION: This study demonstrates that transcatheter closure of a PFO without a permanent implant is technically feasible and safe. Further technique and device modifications are required to achieve higher closure rates.
Resumo:
BACKGROUND: The efficacy of granulocyte colony-stimulating factor (G-CSF) for coronary collateral growth promotion and thus impending myocardial salvage has not been studied so far, to our best knowledge. METHODS AND RESULTS: In 52 patients with chronic stable coronary artery disease, age 62+/-11 years, the effect on a marker of myocardial infarct size (ECG ST segment elevation) and on quantitative collateral function during a 1-minute coronary balloon occlusion was tested in a randomized, placebo-controlled, double-blind fashion. The study protocol before coronary intervention consisted of occlusive surface and intracoronary lead ECG recording as well as collateral flow index (CFI, no unit) measurement in a stenotic and a > or =1 normal coronary artery before and after a 2-week period with subcutaneous G-CSF (10 microg/kg; n=26) or placebo (n=26). The CFI was determined by simultaneous measurement of mean aortic, distal coronary occlusive, and central venous pressure. The ECG ST segment elevation >0.1 mV disappeared significantly more often in response to G-CSF (11/53 vessels; 21%) than to placebo (0/55 vessels; P=0.0005), and simultaneously, CFI changed from 0.121+/-0.087 at baseline to 0.166+/-0.086 at follow-up in the G-CSF group, and from 0.152+/-0.082 to 0.131+/-0.071 in the placebo group (P<0.0001 for interaction of treatment and time). The absolute change in CFI from baseline to follow-up amounted to +0.049+/-0.062 in the G-CSF group and to -0.010+/-0.060 in the placebo group (P<0.0001). CONCLUSIONS: Subcutaneous G-CSF is efficacious during a short-term protocol in improving signs of myocardial salvage by coronary collateral growth promotion.
Resumo:
BACKGROUND: Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. METHODS AND RESULTS: Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45+/-11 years, and 1.8+/-0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37+/-53 months of follow-up. CONCLUSIONS: Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.
Resumo:
BACKGROUND: Cardiac surgery is the reference treatment for patients with left main (LM) disease, although percutaneous coronary intervention with drug-eluting stents is emerging as a possible alternative. The objective of this registry was to evaluate the 2-year outcome of elective percutaneous coronary intervention for unprotected LM disease with paclitaxel-eluting stents. METHODS AND RESULTS: A total of 291 patients were prospectively included from 4 centers. Acute myocardial infarction and cardiogenic shock were the only exclusion criteria. Patients were 69+/-11 years old, 29% were diabetic, and 25% had 3-vessel disease. For distal LM lesions (78%), the provisional side-branch T-stenting approach was used in 92% of cases and final kissing balloon inflation in 97%. Angiographic success was obtained in 99.7% of cases. At 2-year follow-up, the total cardiac death rate was 5.4% (1 EuroSCORE point was associated with a 15% [95% confidence interval 2.9% to 28.2%, P=0.013] higher risk of cardiac death), target-lesion revascularization was 8.7%, and incidence of Q-wave or non-Q-wave myocardial infarction was 0.9% and 3.1%, respectively. The combined end point occurred in 15.8% of cases and stroke in 0.7%. The incidence of definite and probable LM stent thrombosis was 0.7%, whereas the incidence of any stent thrombosis was 3.8%, with a higher risk in patients with side-branch stenting in the presence of LM bifurcation lesions (hazard ratio 9.6, 95% confidence interval 1.2 to 77.7, P=0.035). CONCLUSIONS: Unprotected LM stenting with paclitaxel-eluting stents, with a strategy of provisional side-branch T-stenting for distal lesions, provides excellent acute angiographic results and good mid-term clinical outcomes, with a 15.8% rate of major adverse cardiac events at 2-year follow-up.
Resumo:
BACKGROUND: Different stents in infrainguinal arteries have recently been associated with stent fractures and unfavorable clinical outcome, although data is limited regarding fractures of the Xpert selfexpanding nitinol stent. Thus, purpose of the present investigation was to evaluate its incidence and clinical implications in lower limb arteries. PATIENTS AND METHODS: Fifty-three consecutive patients (53 limbs) with peripheral arterial disease underwent secondary Xpert stent implantation due to suboptimal primary balloon angioplasty (PTA). Median age was 76 years. Stent fractures were evaluated by plain X-ray at median follow-up of 16 months. Stent patency was assessed by duplex ultrasound and sustained clinical improvement was defined as improvement of the ABI of > or = 0.10 together with improvement of at least one Rutherford class above the baseline finding throughout follow-up. RESULTS: Median length of femoropopliteal and infrapopliteal lesion was 3.0 and 2.3 cm, respectively. Sixtyfive stents were implanted in 43 limbs with femoropopliteal and 10 stents in 10 limbs with infrapopliteal lesion, respectively. Stent fractures occurred in 3 of 43 limbs (7.0%) of patients with femoropopliteal lesion with stent-based fracture rate of 4.6%. All fractured stents showed multiple struts fractures and occurred in the distal and middle superficial femoral artery. No stent fracture was observed in infrapopliteal lesions. The fractured stents were not associated with any clinical deterioration. Sustained clinical improvement was 71.0% and 54.6% for femoropopliteal and infrapopliteal lesions, respectively. Stent patency assessed by duplex was 65.2 and 63.9% for femoropopliteal and infrapopliteal lesions, respectively. CONCLUSIONS: Fractures of the Xpert stent were seldom and not associated with unfavorable clinical outcome at midterm follow-up.