993 resultados para automated testing
Resumo:
A major problem in developmental neurotoxicity (DNT) risk assessment is the lack of toxicological hazard information for most compounds. Therefore, new approaches are being considered to provide adequate experimental data that allow regulatory decisions. This process requires a matching of regulatory needs on the one hand and the opportunities provided by new test systems and methods on the other hand. Alignment of academically and industrially driven assay development with regulatory needs in the field of DNT is a core mission of the International STakeholder NETwork (ISTNET) in DNT testing. The first meeting of ISTNET was held in Zurich on 23-24 January 2014 in order to explore the concept of adverse outcome pathway (AOP) to practical DNT testing. AOPs were considered promising tools to promote test systems development according to regulatory needs. Moreover, the AOP concept was identified as an important guiding principle to assemble predictive integrated testing strategies (ITSs) for DNT. The recommendations on a road map towards AOP-based DNT testing is considered a stepwise approach, operating initially with incomplete AOPs for compound grouping, and focussing on key events of neurodevelopment. Next steps to be considered in follow-up activities are the use of case studies to further apply the AOP concept in regulatory DNT testing, making use of AOP intersections (common key events) for economic development of screening assays, and addressing the transition from qualitative descriptions to quantitative network modelling.
Resumo:
Työn teoriaosuudessa käsitellään lujia hitsattavia teräksiä sekä niiden hitsauksessa huomioitavia erityispiirteitä. Työssä esitellään hitsattavuuden arviointiin kehitettyjä teoreettisia menetelmiä sekä otetaan kantaa hitsauksen suoritustekniikkaan ja lisäainevalintaan. Myös lujien terästen hitsauksessa tyypilliset hitsausvirheet on käsitelty tässä työssä. Työn kokeellisessa osassa selvitettiin metsäteknologian tuotteita valmistavan metalliyrityksen käyttämien lujien terästen hitsattavuus ja hitsauksen esivalmistelujen tarpeellisuus. Kokeelliseen osioon kuului myös sopivan lisäainelangan valinta sekä tarkempaan tarkasteluun valitun esimerkkituotteen hitsien laadun selvittäminen. Tutkimuksissa käytettyjä menetelmiä olivat makro- ja mikrohietutkimus, hitsausliitoksen poikittainen vetokoe, Vickersin kovuuskoe ja murtokoe. Tarkasteluissa peilautuu myös hitsauksen automatisoinnin vaikutukset lujien terästen hitsaukseen. Kokeellisessa osiossa huomattiin nuorrutettujen terästen pehmeneminen liian suurella lämmöntuonnilla. Termomekaanisesti valssatut teräkset ovat paremmin hitsattavissa kuin nuorrutetut ja karkaistut teräkset. Kyseessä olevassa yrityksessä hitsattavien materiaalien paksuudet ovat pääsääntöisesti niin ohuita, ettei korotettua työlämpötilaa tarvita. Alilujat lisäaineet soveltuvat hitsauslisäaineeksi tuotantokäyttöön muutamia tuotekohtaisia poikkeuksia lukuun ottamatta.
Resumo:
Different types of aerosolization and deagglomeration testing systems exist for studying the properties of nanomaterial powders and their aerosols. However, results are dependent on the specific methods used. In order to have well-characterized aerosols, we require a better understanding of how system parameters and testing conditions influence the properties of the aerosols generated. In the present study, four experimental setups delivering different aerosolization energies were used to test the resultant aerosols of two distinct nanomaterials (hydrophobic and hydrophilic TiO2). The reproducibility of results within each system was good. However, the number concentrations and size distributions of the aerosols created varied across the four systems; for number concentrations, e.g., from 10(3) to 10(6) #/cm(3). Moreover, distinct differences were also observed between the two materials with different surface coatings. The article discusses how system characteristics and other pertinent conditions modify the test results. We propose using air velocity as a suitable proxy for estimating energy input levels in aerosolization systems. The information derived from this work will be especially useful for establishing standard operating procedures for testing nanopowders, as well as for estimating their release rates under different energy input conditions, which is relevant for occupational exposure.
Resumo:
Many people regard the concept of hypothesis testing as fundamental to inferential statistics. Various schools of thought, in particular frequentist and Bayesian, have promoted radically different solutions for taking a decision about the plausibility of competing hypotheses. Comprehensive philosophical comparisons about their advantages and drawbacks are widely available and continue to span over large debates in the literature. More recently, controversial discussion was initiated by an editorial decision of a scientific journal [1] to refuse any paper submitted for publication containing null hypothesis testing procedures. Since the large majority of papers published in forensic journals propose the evaluation of statistical evidence based on the so called p-values, it is of interest to expose the discussion of this journal's decision within the forensic science community. This paper aims to provide forensic science researchers with a primer on the main concepts and their implications for making informed methodological choices.
Resumo:
Invasive mold infections are life-threatening diseases for which appropriate antifungal therapy is crucial. Their epidemiology is evolving, with the emergence of triazole-resistant Aspergillus spp. and multidrug-resistant non-Aspergillus molds. Despite the lack of interpretive criteria, antifungal susceptibility testing of molds may be useful in guiding antifungal therapy. The standard broth microdilution method (BMD) is demanding and requires expertise. We assessed the performance of a commercialized gradient diffusion method (Etest method) as an alternative to BMD. The MICs or minimal effective concentrations (MECs) of amphotericin B, voriconazole, posaconazole, caspofungin, and micafungin were assessed for 290 clinical isolates of the most representative pathogenic molds (154 Aspergillus and 136 non-Aspergillus isolates) with the BMD and Etest methods. Essential agreements (EAs) within ±2 dilutions of ≥90% between the two methods were considered acceptable. EAs for amphotericin B and voriconazole were >90% for most potentially susceptible species. For posaconazole, the correlation was acceptable for Mucoromycotina but Etest MIC values were consistently lower for Aspergillus spp. (EAs of <90%). Excellent EAs were found for echinocandins with highly susceptible (MECs of <0.015 μg/ml) or intrinsically resistant (MECs of >16 μg/ml) strains. However, MEC determinations lacked consistency between methods for strains exhibiting mid-range MECs for echinocandins. We concluded that the Etest method is an appropriate alternative to BMD for antifungal susceptibility testing of molds under specific circumstances, including testing with amphotericin B or triazoles for non-Aspergillus molds (Mucoromycotina and Fusarium spp.). Additional study of molecularly characterized triazole-resistant Aspergillus isolates is required to confirm the ability of the Etest method to detect voriconazole and posaconazole resistance among Aspergillus spp.
Resumo:
The detailed in-vivo characterization of subcortical brain structures is essential not only to understand the basic organizational principles of the healthy brain but also for the study of the involvement of the basal ganglia in brain disorders. The particular tissue properties of basal ganglia - most importantly their high iron content, strongly affect the contrast of magnetic resonance imaging (MRI) images, hampering the accurate automated assessment of these regions. This technical challenge explains the substantial controversy in the literature about the magnitude, directionality and neurobiological interpretation of basal ganglia structural changes estimated from MRI and computational anatomy techniques. My scientific project addresses the pertinent need for accurate automated delineation of basal ganglia using two complementary strategies: ? Empirical testing of the utility of novel imaging protocols to provide superior contrast in the basal ganglia and to quantify brain tissue properties; ? Improvement of the algorithms for the reliable automated detection of basal ganglia and thalamus Previous research demonstrated that MRI protocols based on magnetization transfer (MT) saturation maps provide optimal grey-white matter contrast in subcortical structures compared with the widely used Tl-weighted (Tlw) images (Helms et al., 2009). Under the assumption of a direct impact of brain tissue properties on MR contrast my first study addressed the question of the mechanisms underlying the regional specificities effect of the basal ganglia. I used established whole-brain voxel-based methods to test for grey matter volume differences between MT and Tlw imaging protocols with an emphasis on subcortical structures. I applied a regression model to explain the observed grey matter differences from the regionally specific impact of brain tissue properties on the MR contrast. The results of my first project prompted further methodological developments to create adequate priors for the basal ganglia and thalamus allowing optimal automated delineation of these structures in a probabilistic tissue classification framework. I established a standardized workflow for manual labelling of the basal ganglia, thalamus and cerebellar dentate to create new tissue probability maps from quantitative MR maps featuring optimal grey-white matter contrast in subcortical areas. The validation step of the new tissue priors included a comparison of the classification performance with the existing probability maps. In my third project I continued investigating the factors impacting automated brain tissue classification that result in interpretational shortcomings when using Tlw MRI data in the framework of computational anatomy. While the intensity in Tlw images is predominantly
Resumo:
We empirically applied the GrooFiWorld agent-based model (Puga-González et al. 2009) in a group of captive mangabeys (Cercocebus torquatus). We analysed several measurements related to aggression and affiliative patterns. The group adopted a combination of despotic and egalitarian behaviours resulting from the behavioural flexibility observed in the Cercopithecinae subfamily. Our study also demonstrates that the GrooFiWorld agent-based model can be extended to other members of the Cercopithecinae subfamily generating parsimonious hypotheses related to the social organization.
Resumo:
La dermatite irritative est décrite comme une réaction réversible, non immunologique caractérisée par des lésions d'aspect très variable, allant de la simple rougeur jusqu'à la formation de bulles voire d'une nécrose, accompagnée de prurit ou d'une sensation de brûlure suite à I' application d'une substance chimique. Le teste de prédiction d'irritation cutanée est traditionnellement depuis les années 1940 le Test de Draize. Ce test consiste en l'application d'une substance chimique sur une peau rasée de lapin pendant 4h et de regarder à 24h si des signes cliniques d'irritations sont présents. Cette méthode critiquable autant d'un point de vue éthique que qualitative reste actuellement le teste le plus utilisé. Depuis le début des années 2000 de nouvelles méthodes in vitro se sont développées tel que le model d'épiderme humain recombiné (RHE). Il s agit d'une multicouche de kératinocyte bien différencié obtenu depuis une culture de don d'ovocyte. Cependant cette méthode en plus d'être très couteuse n'obtient au mieux que 76% de résultat similaire comparé au test in vivo humain. Il existe donc la nécessité de développer une nouvelle méthode in vitro qui simulerait encore mieux la réalité anatomique et physiologique retrouvée in vivo. Notre objectif a été de développer cette nouvelle méthode in vitro. Pour cela nous avons travaillé avec de la peau humaine directement prélevée après une abdominoplastie. Celle ci après préparation avec un dermatome, un couteau dont la lame est réglable pour découper l'épaisseur souhaitée de peau, est montée dans un système de diffusion cellulaire. La couche cornée est alors exposée de manière optimale à 1 ml de la substance chimique testée pendant 4h. L'échantillon de peau est alors fixé dans du formaldéhyde pour permettre la préparation de lames standards d'hématoxyline et éosine. L'irritation est alors investiguée selon des critères histopathologiques de spongioses, de nécroses et de vacuolisations cellulaires. Les résultats de ce.tte première batterie de testes sont plus que prometteurs. En effet, comparé au résultat in vivo, nous obtenons 100% de concordance pour les 4 même substances testes irritantes ou non irritantes, ce qui est supérieur au model d épiderme humain recombiné (76%). De plus le coefficient de variation entre les 3 différentes séries est inférieur à 0.1 ce qui montre une bonne reproductibilité dans un même laboratoire. Dans le futur cette méthode va devoir être testée avec un plus grand nombre de substances chimiques et sa reproductibilité évaluée dans différents laboratoires. Mais cette première evaluation, très encourageante, ouvre des pistes précieuses pour l'avenir des tests irritatifs.
Resumo:
Living bacteria or yeast cells are frequently used as bioreporters for the detection of specific chemical analytes or conditions of sample toxicity. In particular, bacteria or yeast equipped with synthetic gene circuitry that allows the production of a reliable non-cognate signal (e.g., fluorescent protein or bioluminescence) in response to a defined target make robust and flexible analytical platforms. We report here how bacterial cells expressing a fluorescence reporter ("bactosensors"), which are mostly used for batch sample analysis, can be deployed for automated semi-continuous target analysis in a single concise biochip. Escherichia coli-based bactosensor cells were continuously grown in a 13 or 50 nanoliter-volume reactor on a two-layered polydimethylsiloxane-on-glass microfluidic chip. Physiologically active cells were directed from the nl-reactor to a dedicated sample exposure area, where they were concentrated and reacted in 40 minutes with the target chemical by localized emission of the fluorescent reporter signal. We demonstrate the functioning of the bactosensor-chip by the automated detection of 50 μgarsenite-As l(-1) in water on consecutive days and after a one-week constant operation. Best induction of the bactosensors of 6-9-fold to 50 μg l(-1) was found at an apparent dilution rate of 0.12 h(-1) in the 50 nl microreactor. The bactosensor chip principle could be widely applicable to construct automated monitoring devices for a variety of targets in different environments.