930 resultados para Web 2.0 Business Model


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Slutrapport till Malmö stad, maj 2010

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The following paper was conducted with the support of several entrepreneurs and startups from Brazil. The aim of the research was to find out which impact the Business Model Canvas, further abbreviated as BMC, has on technology-oriented startups in Brazil. The first step of the study was identify some general concepts of entrepreneurship, as well as the conditions and environment of the country. Afterwards, it was focused on defining and comparing different business model tools and concepts to the BMC. After the literature review and meeting with several professionals in the area of entrepreneurship and startups, a questionnaire was formulated in order to conduct the qualitative study and identify the main impact of the tool. The questionnaire was answered by ten startups. In order to check the validity and credibility of the research outcomes, theory and investigator triangulation was used. As a result, the usage of the BMC could be evaluated by obtaining the outcomes and the theory, which showed that Brazilian tech startups are using Osterwalder’s model for the reason of idea creation and testing, validating and pivoting their business model. Interestingly, the research revealed that the entrepreneurs are using the tool often not in the traditional way of printing it, but rather applying it as a thinking approach. Besides, the entrepreneurs are focusing mostly on developing a strong Value Proposition, Customer Segment and sustainable Revenue Streams, while afterwards the remaining building blocks are built. Moreover, the research showed that the startups are using also other concepts, such as the Customer Development Process or Build-Measure-Learn Feedback Loop. These methodologies are often applied together with the BMC and helps to identify the most sustainable components of the business idea. Keywords: Business

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este projeto teve como principal objetivo continuar o desenvolvimento do quiosque multimédia FNAC. Filial do Grupo Pinault Printemps, a FNAC é líder europeu na distribuição de bens tecnológicos e culturais. Nesta fase do desenvolvimento, o foco do projeto centrou-se na procura da melhor forma de mostrar ao utilizador a localização de um produto na loja FNAC Madeira, expansão das funcionalidades aos restantes produtos e o redesenho da interface do quiosque multimédia FNAC. Por forma a identificar uma forma eficaz de dar a conhecer ao utilizador a localização de um produto dentro da loja FNAC Madeira, foi efetuado um estudo que consistiu em questionários e testes com utilizadores para comparar duas formas de localização, por planta da loja ou por vídeo em tempo real. A primeira versão do quiosque multimédia FNAC apenas possuía suporte a livros, pelo que foi necessário tornar a aplicação o mais abstrata possível por forma a gerar as categorias de produtos em runtime recorrendo a ficheiros XML. Por fim, para redesenhar a interface do quiosque multimédia FNAC, foram efetuadas análises às interfaces da primeira versão, utilizando as heurísticas de Nielsen e os “Principles of good form” de Larry Constantine. Após a fase de análise as interfaces foram redesenhadas tendo por base a análise efetuada, o guia de norma FNAC 2011 e breves testes de usabilidade com utilizadores. Do estudo realizado, na procura pela melhor forma de localização, foram identificados alguns problemas relacionados com a utilização de um vídeo em tempo real para a identificação, tal como as interferências externas por parte dos outros clientes do espaço comercial e foi possível constatar um melhor desempenho e aceitação da localização por planta. A localização por planta mostrou-se suficiente para os utilizadores conseguirem identificar o local onde o produto estava exposto, pois permitia-lhes identificar o local onde encontravam-se e obter uma localização mais precisa do local, necessitando apenas de olhar em volta para conseguir relacionar o que era possível visualizar na planta com aquilo que os rodeava na loja.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were used in mechanical test. The samples were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 were represented by the standard technique with two straight miniplates parallel to each other. Groups 2 and 5 were stabilized by squared miniplates and groups 3 and 6 were fixed by rectangular design. Each group was subjected to a mechanical test at a displacement speed of 10 mm/min on a universal testing machine, receiving linear vertical load on the region of the left first molar. The values of the maximum load and when displacements reached 5 mm were obtained and statistically analyzed by calculating the confidence interval of 95%. Fixation systems using squared (G2) and rectangular (G3) miniplates obtained similar results. No statistically significant differences with respect to the maximum load and the load at 5 mm displacement were found when compared to standard method in symphyseal fractures (G1). In parasymphysis the fixation method using squared miniplates (G5) obtained results without significant differences regarding the maximum load and the load at 5 mm when compared to the standard configuration (G4). The fixation method using rectangular miniplates (G6) showed inferior results which were statistically significant when compared to the standard configuration (G4) for parasymphysis fractures. The mechanical behavior of the fixation methods was similar, except when rectangular miniplates were used. The fixation methods showed better results with statistical significance in symphyseal fractures

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation aims at extending the JCircus tool, a translator of formal specifications into code that receives a Circus specification as input, and translates the specification into Java code. Circus is a formal language whose syntax is based on Z s and CSP s syntax. JCircus generated code uses JCSP, which is a Java API that implements CSP primitives. As JCSP does not implement all CSP s primitives, the translation strategy from Circus to Java is not trivial. Some CSP primitives, like parallelism, external choice, communication and multi-synchronization are partially implemented. As an aditional scope, this dissertation will also develop a tool for testing JCSP programs, called JCSPUnit, which will also be included in JCircus new version. The extended version of JCircus will be called JCircus 2.0.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Numerous "in vitro" investigations have been conducted to evaluate the role of screw size and pattern in determining optimal resistance to deformation, often these have been controversial. The aim of this study was to evaluate the effect of screw size and insertion technique on the stability of sagittal split osteotomies.Materials and methods: This study used twenty polyurethane replicas of human hemimandibles with a prefabricated sagittal split ramus osteotomy (SSRO). The hemimandibles were stabilized with 1.5 mm and 2.0 mm titanium screws inserted in an inverted L configuration. All specimens were tested to determine the strength and stability of the fixation.Results: In all cases there was failure of the synthetic bone before there was any evidence of screw failure. There were no significant differences in the load necessary to make the construct fail between the 1.5 or 2.0 mm screw sizes.Conclusion: There was no statistically significant difference between the strengths achieved with screws of 1.5 and 2.0 mm diameters for fixation of SSRO performed in synthetic mandibles. There was no fracture of the 1.5 mm or 2.0 mm diameter screws in any of the tests. 1.5 mm diameter screws in an inverted L pattern have as much stability and mechanical resistance as a 2.0 mm screw, may be safely used for this procedure. (C) 2010 European Association for Cranio-Maxillo-Facial Surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The so-called conformal affine Toda theory coupled to the matter fields (CATM), associated to the (s) over capl(2) affine Lie algebra, is studied. The conformal symmetry is fixed by setting a connection to zero, then one defines an off-critical model, the affine Toda model coupled to the matter (ATM). Using the dressing transformation method we construct the explicit forms of the two-soliton classical solutions, and show that a physical bound soliton-antisoliton pair (breather) does not exist. Moreover, we verify that these solutions share some features of the sine-Gordon (massive Thirring) solitons, and satisfy the classical equivalence of topological and Noether currents in the ATM model. We show, using bosonization techniques that the ATM theory decouples into a sine-Gordon model and a free scalar. Imposing the Noether and topological currents equivalence as a constraint, one can show that the ATM model leads to a bag model like mechanism for the confinement of the color charge inside the sine-Gordon solitons (baryons).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador: