968 resultados para Water supply management indicators


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluoride levels in the public water supplies of 40 Brazilian cities were analyzed and classified on the basis of risk/benefit balance. Samples were collected monthly over a seven-year period from three sites for each water supply source. The samples were analyzed in duplicate in the laboratory of the Center for Research in Public Health - UNESP using an ion analyzer coupled to a fluoride-specific electrode. A total of 19,533 samples were analyzed, of which 18,847 were artificially fluoridated and 686 were not artificially fluoridated. In samples from cities performing water fluoridation, 51.57% (n=9,720) had fluoride levels in the range of 0.55 to 0.84 mg F/L; 30.53% (n=5,754) were below 0.55 mg F/L and 17.90% (n=3,373) were above 0.84 mg F/L (maximum concentration=6.96 mg F/L). Most of the cities performing fluoridation that had a majority of samples with fluoride levels above the recommended parameter had deep wells and more than one source of water supply. There was some variability in the fluoride levels of samples from the same site and between collection sites in the same city. The majority of samples from cities performing fluoridation had fluoride levels within the range that provides the best combination of risks and benefits, minimizing the risk of dental fluorosis while preventing dental caries. The conduction of studies about water distribution systems is suggested in cities with high natural fluoride concentrations in order to optimize the use of natural fluoride for fluoridation costs and avoid the risk of dental fluorosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fish farms' water quality management is analyzed with regard to the management employed and the different trophic states are compared within the system during the dry and rainy seasons. Six sites were marked two in the water supply (P1 and P2), and four within the fish farm (P3 to P6). Whereas sites P1 and P2 (water supply) were characterized as oligotrophic, the others were mesotrophic and eutrotrophic sites. Environmental variables, mainly nutrients, conductivity, COD, BOD5 and TSS tended to increase as from P3 due to management and fertilization. Greater impact has been registered in the fish farm under analysis for variables COD, ammonia, total phosphorus and TSS during the discharge and pond emptying period. Frequent monitoring of water quality should be undertaken in fish breeding and plankton production ponds, especially in those close to P3 and P4. Removal of sediment in decantation lake or P5 is also recommended to decrease nutrient concentrations, especially phosphorus, accumulated on the bottom soil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantitative variations in heterotrophic plate count (HPC) and in the presence of indicator microorganisms in 0.5, 1.5 and 20-L bottles of different brands of Brazilian mineral water were analyzed during their shelf life. No variations were identified in the presence of indicator microorganisms, but quantitative variations in HPC were observed in some brands, which suggests that changes may be occurring in the water quality during storage. The aim of this study was also to evaluate the quality of the bottled mineral waters and the presence of enterococci and Pseudomonas aeruginosa were verified in six and two bottles, respectively, which is in disagreement with the microbiological quality criteria established in the current legislation. Although no limit is set for HPC in mineral water, this study relies on the limit of 500 colony-forming units per mL of sample (CFU/mL). Seventy-two bottles presented levels above 500 CFU/mL and up to 560,000 CFU/mL. This study showed that the control of HPC (<500 CFU/mL) for non-returnable packaging seems to be adequate to ensure the quality of mineral water during storage. The high values of HPC and its variations detected during storage seem to fully justify the need for a reevaluation of the use of HPC in bottled mineral water quality management. More detailed studies on the potential health risk of HPC and its variations in mineral water are also needed. © 2012 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Strawberry yield and quality was evaluated after drastic pruning (second cycle), under different soil water tensions, drip irrigation. The experiment was conducted on beds at a greenhouse, located at Engineering Department, Federal University of Lavras (UFLA), from April to December of 2010. An experimental design was in randomized blocks with three replicates. The treatments were composed of six different soil water tension, 15, 25, 35, 45, 55 e 70 kPa. Results obtained allowed to verify that to higher values of: total and commercial fresh weight of fruits per plant, total and commercial number fruits per plant and total and commercial yield, it is necessary to irrigate when soil water tension gets approximately to 15 kPa, at 0.15 m deep. Commercial average fruit mass and noncommercial fresh weight of fruits per plant, were not reduced under different soil water tensions applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the total number of clusters per plant and the sugar concentration of Superior Seedless grapevine branches under different soil water tensions conditions. The statistical design was a randomized block with 4 treatments (a) control, b) 70 kPa tension, c) 50 kPa tension, d) 30 kPa tension, and 6 replications, each plot consisting of two plants. Soil moisture curves were plotted in laboratory and field conditions, potential bud fertility (carried out with the help of a 30x magnifier glass and collecting 17 branches in the primary arm of the plant with 15 buds each), actual fertility (given by the fertile buds to sprouted buds per plant ratio) and total sugars. Laboratory conditions helped stress to reach a -70 kPa level in just 21 days during the procedure to determine the retention curve in the laboratory. The different stress levels applied to the soil did not cause significant differences in the total number of clusters per plant. However, a -30 kPa stress showed a 68% reduction in water depth when compared to control and different soil water stress affected the carbohydrate percentage in branches of the Superior Seedless vine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography