INTRODUCTION: Despite significant left ventricular (LV) systolic dysfunction and cardiomegaly, pulmonary congestion does not seem to be a major finding in Chagas' cardiomyopathy (CC). This study sought to identify echocardiographic parameters associated with pulmonary congestion in CC and in dilated cardiomyopathy of other etiologies, such as non-CC (NCC), and to compare pulmonary venous hypertension between the two entities. METHODS: A total of 130 consecutive patients with CC and NCC, with similar echocardiographic characteristics, were assessed using Doppler echocardiography and chest radiography. Pulmonary venous vessel abnormalities were graded using a previously described pulmonary congestion score, and this score was compared with Doppler echocardiographic parameters. RESULTS: NCC patients were older than CC patients (62.4 ± 13.5 × 47.8 ± 11.2, p = 0.00), and there were more male subjects in the CC group (66.2% × 58.5%, p = 0.4). Pulmonary venous hypertension was present in 41 patients in the CC group (63.1%) and in 63 (96.9%) in the NCC group (p = 0.0), the mean lung congestion score being 3.2 ± 2.3 and 5.9 ± 2.6 (p = 0.0), respectively. On linear regression multivariate analysis, the E/e' ratio (β = 0.13; p = 0.0), LV diastolic diameter (β = 0.06; p = 0.06), left atrial diameter (β = 0.51; p = 0.08), and right ventricular (RV) end-diastolic diameter (β = 0.02; p = 0.48) were the variables that correlated with pulmonary congestion in both groups. CONCLUSIONS: Pulmonary congestion was less significant in patients with CC. The degree of LV of systolic and diastolic dysfunction and the RV diameter correlated with pulmonary congestion in both groups. The E/e' ratio was the hallmark of pulmonary congestion in both groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neotropical polycystic echinococcosis (NPE) is a parasitic disease caused by cestodes of Echinococcus vogeli. This parasite grows most commonly in the liver, where it produces multiples cysts that cause hepatic and vessel necrosis, infects the biliary ducts, and disseminates into the peritoneal cavity, spreading to other abdominal and thoracic organs. In cases of disseminated disease in the liver and involvement of biliary ducts or portal system, liver transplantation may be a favorable option. We present a report of the first case of liver transplantation for the treatment of advanced liver NPE caused by E. vogeli.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Mutações em genes envolvidos na formação do coração e anomalias em qualquer etapa deste processo causam frequentemente malformações cardíacas, que representam o tipo mais comum de defeitos em neonatais, afetando cerca de 1% dos nascimentos por ano. Assim, estima-se que 20 milhões de pessoas sejam portadoras de um defeito cardíaco congénito. O coração da Drosophila melanogaster (mosca-da-fruta), denominado vaso dorsal, é um órgão relativamente simples que actua como uma bomba muscular, contraindo automaticamente para permitir a circulação da hemolinfa através do corpo. A formação do vaso dorsal na mosca é muito semelhante ao desenvolvimento do coração em vertebrados, representando por isso, um poderoso modelo para estudar a rede de genes e os padrões regulatórios relacionados com o desenvolvimento deste órgão. Anteriormente, nós identificámos um gene em Drosophila, darhgef10, fortemente expresso no coração em desenvolvimento e cuja deleção induz anormalidades cardíacas subtis mas prevalentes. Os mutantes para darhgef10 são viáveis e férteis no ambiente controlado de laboratório. Este trabalho teve como objectivos caracterizar fenotipicamente os mutantes nulos para darhgef10, determinar a localização subcelular da proteína dArhgef10 e investigar a base celular subjacente ao defeito no alinhamento dos cardioblastos observado nos mutantes. Os nossos resultados revelaram que a deleção de darhgef10 provoca uma severa redução da viabilidade, sem no entanto comprometer o tempo de desenvolvimento e a longevidade. Por outro lado, o aumento da expressão de darhgef10 em músculos, glândulas salivares e no disco imaginal do olho afeta drasticamente a integridade destes tecidos. A expressão ectópica de darhgef10 in vitro e in vivo revelou que a proteína está localiza no citoplasma com enriquecimento junto à membrana celular, com associação à actina F. Live imaging de embriões mutantes para darhgef10 revelou que os defeitos observados no coração podem estar associados a um defeito na adesão dos músculos alary e/ou das células pericardiais ao vaso dorsal. O homólogo humano de darhgef10, ARHGEF10, também é expresso no coração e está associação a uma maior susceptibilidade para a ocorrência de acidentes vasculares cerebrais aterotrombóticos, sugerindo que o que aprendemos sobre darhgef10 em Drosophila pode ter implicações do ponto de vista clínico para a saúde humana. ----------------------------- ABSTRACT: Mutations in genes controlling heart development and abnormalities in any of its steps frequently cause cardiac malformations, the most common type of birth defects in humans, affecting nearly 1% of births per year. Hence around 20 million adults are expected to live with a congenital heart defect. The Drosophila melanogaster heart, called dorsal vessel, is a relatively simple organ that acts as a muscular pump contracting automatically to allow the circulation of hemolymph. Drosophila heart formation shares many similarities with heart development in vertebrates providing a powerful system to study gene networks and regulatory pathways involved in heart development. We have previously identified a Drosophila gene, darhgef10, which is strongly expressed in the developing heart and when deleted, leads to flies with highly prevalent yet subtle heart abnormalities, compatible with unchallenged life in the laboratory. Our aims were to phenotypically characterize homozygous null darhgef10 mutants, characterize the subcellular localization of dArhgef10 and to study the cellular basis of the misaligned cardioblasts defect. We found that about half of darhgef10 mutants die during development. However, the survivors surprisingly have a nearly normal developmental time, adult locomotor behavior and total lifespan. Detection of transgene-derived dArhgef10 protein in vitro and in vivo using custom antibodies revealed a cytosolic protein slightly enriched in the cellular membranes and associated with F-actin. Tissue-specific darhgef10 expression disrupts the normal morphology of developing muscles, salivary glands and the eye. Live imaging of darhgef10 mutant embryos revealed that heart defect could be caused by a reduced capacity of attachment of pericardial cells and/or alary muscle to dorsal vessel. The human homolog of darhgef10 is also expressed in the heart and is a susceptibility gene for atherothrombotic stroke, suggesting that what we learn about the function of this gene and its phenotypes in Drosophila could have implications to human health.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ligature of the left renal vein is an alternative whenever this vessel is injured. The purpose of this study was to evaluate the capacity of the affluents of the left renal vein, proximal to the ligature, to maintain tissue vitality and function of the left kidney. Fifteen mongrel male dogs were divided in 3 groups of 5 dogs: Group I (control) - a laparotomy was performed, and the abdominal structures were only identified; Group II - the left renal vein was tied, close to vena cava; Group III - the same procedure as for Group II and a right nephrectomy. Blood urea nitrogen and serum creatinine levels were measured before the procedure, and every 3 days during 4 weeks in the postoperative period. Renal arteriography and an excretory urogram were performed on the animals that survived 60 days. Thereafter, or immediately after precocious death, the kidneys were removed for histological examination. All the animals of Group III died before two months (mean = 10.5 +-3.2 days), while the animals of Group II survived during that period. There was a complete exclusion of the left kidney in all dogs that underwent renal vein ligature. In the animals of Group II, the renal cortico-medullary limits could not be identified. At microscopy, the aspect was suggestive of nephrosclerosis. In the animals of Group III, the left kidney was enlarged, and a great amount of intravascular and intrapelvic blood clots were observed. At microscopy, extensive areas of necrosis, inflammatory infiltration, and hemorrhage were identified. In conclusion, the tributaries of the renal vein were not sufficient to maintain the tissue vitality and function of the left kidney after ligature of its main vein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Os mais recentes métodos de neuro imagem tal como a Ressonância Magnética (RM) permitiram obter imagens detalhadas do cérebro humano in vivo. Essas imagens revelam, muitas vezes, achados imprevistos face ao padrão normal, com elevada propensão para os indivíduos idosos e franca coexistência com fatores de risco vascular, como característica dum processo de envelhecimento normal. Embora na última década tenham surgido várias publicações sobre este assunto, ele continua ainda pouco explicado. Um pouco por todo o mundo têm emergido os programas de prevenção da doença e promoção da saúde desenvolvidos pela Saúde Pública suportadas sobretudo pelo avanço das tecnologias médicas que resultaram, entre outros impactos, num crescimento da população idosa. Estima-se, em 2030, uma composição demográfica com 20% de indivíduos acima dos 65 anos. Neste contexto, a doença microvascular cerebral é a causa mais frequente de comprometimento cognitivo vascular no idoso sendo as características senescentes na imagem por RM do tipo lesões isquémicas da Substância Branca (Leukoaraiosis) e enfartes lacunares (Status lacunar), atrofia cerebral, gliose e acumulação excessiva de ferro nos núcleos da base. Esta tese, considerando a linha de investigação de que deriva – Ciências da Vida - especialização em Medicina Clinica - Biotecnologia, reúne e reflete sobre três vertentes ligadas à RM e interdependentes em relação a uma problemática comum. A primeira trata da caracterização da Tecnologia por Ressonância Magnética existente em Portugal, a qual inclui uma avaliação exploratória da aplicação da técnica de Difusão Anisotrópica nos estudos cerebrais. As dimensões analíticas estudadas foram a Tecnológica, Sociodemográfica e Económica. Na recolha de dados recorreu-se a várias fontes de informação e a uma metodologia exploratória faseada, validada pela triangulação dos resultados. A sua análise obedeceu a critérios de estratificação e agrupamento segundo as mesmas dimensões analíticas. Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular A segunda descreve o estudo anátomo – radiológico que recaiu sobre parâmetros de quantificação assente na temática do cérebro do idoso em cadáver segundo uma metodologia experimental aplicada às métricas da difusão por RM. Na terceira, e última, é apresentado o estudo técnico - radiológico para avaliação e otimização da imagem ponderada em difusão em estudos clínicos associados ao cérebro do idoso “The Usual Brain Aging” ou Envelhecimento Cerebral Normal, com base metodológica assente nos critérios e indicadores estabelecidos pelo Estudo de Imagem de Roterdão (Rotterdam Scan Study - RSS). Como principais resultados obteve-se que não existem em Portugal estruturas para avaliação dos equipamentos pesados ou Agência de Avaliação das Tecnologias da Saúde para desenvolver o importante papel da produção de estudos comparativos entre os equipamentos disponíveis no mercado, a relação preço-qualidade e a sua afetação às necessidades clínico-epidemiológicas. Constatou-se que a implementação de equipamentos de RM está fortemente assente em critérios económicos carecendo de recomendações e diretivas para o uso racionalizado destas tecnologias. Quanto a dados quantitativos concluímos que a maioria dos equipamentos está instalada em instituições privadas (80,2%); a intensidade de campo magnético mais frequente é [1,5T] com 119 equipamentos; os equipamentos estão instalados maioritariamente nos distritos de Lisboa (55 unidades) e do Porto (39 unidades); o rácio médio de equipamentos por habitante em Portugal é de 1 para 65 195 habitantes; a amplitude de gradientes com maior expressão na amostra é 30-39mT/m; a maioria dos equipamentos foi instalada no intervalo temporal [2009-2012] com 59 equipamentos; apenas 6 instituições desenvolvem investigação clinica e a maioria das bobinas para estudos de crânio são do tipo Array. O estudo de otimização da técnica da difusão revelou, quanto à avaliação dos valoresb, que os mais baixos (b=500 s/mm2 e b=1000 s/mm2), apresentam maior IS e SNR sendo esta uma boa medida referente à qualidade de imagem, no entanto, os valores-b mais elevados (b=2000 s/mm2) apresentam maior CNR e CR, face aos anteriores, o Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular que apesar de proporcionar inferior detalhe anatómico e consequentemente inferior qualidade de imagem, num encéfalo normal, pode auxiliar na interpretação e apresentar vantagens na identificação de lesões microvasculares sempre que persistirem dúvidas em relação ao diagnóstico diferencial de doença microvascular do tipo status lacunar ou Hiperintensidades da Substância Branca. As alterações deste parâmetro são particularmente refletidas nas diferenças da avaliação da qualidade de imagem na região fronto-calos Concluímos da avaliação quantitativa da concentração média de ferro (26Fe) em todas as faixas etárias que os núcleos da base que apresentam maior concentração são, por ordem decrescente: Substância Nigra, Globus Pallidus, Putamen, Tálamo, Núcleo Rubro e Núcleo Caudado; que existe uma predominância na concentração de ferro (26Fe) no hemisfério esquerdo e que os indivíduos do género masculino apresentam mais ferro (26Fe) que os do género feminino nas faixas etárias [30-40[, [40-50[ e [50-60[. Como principal conclusão do estudo da concentração média de ferro em relação à idade destacamos que a concentração média de ferro (26Fe) é superior nos grupos etários superiores, logo aumenta com a idade, sobretudo na Substância Nigra e no Núcleo Lenticular. No estudo técnico-radiológico encontrámos evidências do aumento da difusibilidade da água na substância branca subcortical dos sujeitos idosos comparativamente aos mais jovens. Uma relação idêntica foi avaliada nos tálamos. O aumento relacionado com a idade parece ser predominantemente observado em doentes com mais de 65 anos de idade o que pode refletir alterações estruturais ligeiras associados ao envelhecimento normal. Os resultados indicam que a análise quantitativa das imagens ponderadas em difusão fornece informações, sobre a estrutura do cérebro, as quai s não estão disponíveis apenas por inspeção visual, tanto nas imagens ponderadas em difusão como em outras sequências de aplicação clínica de rotina. Para fazer face às desvantagens dos sistemas de quantificação das HSB os quais são dispendiosos, complexos, requererem tecnologia e formação específicas, recomendamos que a aplicação automatizada GUIAL, desenvolvida ao longo do nosso trabalho é de utilização elementar e prática para que seja introduzida nos sistemas de aquisição de imagem por RM com o fim de integrar o processamento de imagem nos indivíduos portadores de fatores de risco vascular. A avaliação do ADC, nesta amostra, permitiu concluir que a variação desta variável é explicada estatisticamente pela existência da condição clínica de status lacunar em ambos os hemisférios ou por outras palavras, o status lacunar influencia o valor de ADC. Embora uma pequena percentagem da variação do ADC seja explicada pelo género, o ADC nos homens foi superior ao das mulheres o que não nos surpreende, pois são também os homens onde a frequência de doença microvascular se revelou mais expressiva. Os valores do ADC, globalmente, entre os hemisférios cerebrais não mostraram alterações exceto na SB entre os idosos e não idosos. A SB da região frontal mostrou valores diminuídos na anisotropia e isotropia face às restantes áreas anatómicas. Os estudos indicam que na idade avançada existe uma maior predisposição para suscetibilidades de estrutura com status de desconexão. A classificação das HSB foi superior em indivíduos mais velhos e com status lacunar, e em menor quantidade (inferior rating de classificação) nos indivíduos idosos sem status lacunar. As alterações volumétricas foram mais frequentes no homem do que na mulher, presumivelmente devido à associação com a elevada classificação de status lacunar. Um aumento do índice de Evan correspondeu, neste estudo, ao aumento das HSB, à diminuição do volume cerebral total, à expansão ventrículo-sulcal frontal e ao aumento da medida do ângulo caloso. Estes resultados foram agravados pela classificação elevada de status lacunar nos indivíduos que apresentaram indícios de doença de pequenos vasos, com manifesto aumento dos espaços de Virchow-Robin,enfartes lacunares ou HSB. Esses resultados foram mais expressivos no género masculino do que no feminino revelando uma maior vulnerabilidade sobretudo na atrofia frontal nos homens. Por sua vez as dimensões do Corpo Caloso tornaram-se reduzidas devido à compressão dos ventrículos laterais e terceiro ventrículo. Estes indicadores tiveram expressão particularmente nos indivíduos com mais de 65 anos. ---------------------------------------------------------------------------------------------ABSTRACT: The latest neuroimaging methods, such as Magnetic Resonance Imaging (MRI), have enabled detailed images of in vivo human brain. These images reveal often unexpected findings related to the normal pattern, with high predisposition for the elderly people with forthright coexistence with vascular risk factors such as characteristics of a normal aging process. Although it has been, in the last decade, several publications on this subject, it is still little explained. All over the world have emerged disease prevention programs and health promotion developed by the Public Health sector, supported mainly by the advancement of medical technologies that have resulted, among other impacts, in a growing of the elderly population. It is estimated, in 2030, a demographic composition with 20% o people over 65 years. In this context, microvascular disease is the most common cause of cognitive vascular impairment in the elderly and senescent characteristics in the MRI trough ischemic lesions of the white matter (Leukoaraiosis) and lacunar infarcts (lacunar status), cerebral atrophy, gliosis and iron accumulation in the basal ganglia in excess.This thesis, considering the research line that stems - Life Sciences - specialization in Clinical Medicine, Biotechnology, gathers and reflects on three aspects linked to MR, interdependent and related to a common problem. The first deals with the Magnetic Resonance Technology characterization in Portugal, which includes an exploratory evaluation of the implementation of Anisotropic Diffusion technique in brain studies. The analytical dimensions studied were the Technologic, Socio-demographic and Economics. Collecting data was supported by different sources of information and was applied an exploratory methodology whose results were validated by triangulation. The research method was grouped and stratified criteria under the same analytical dimensions. The second describes the anatomical study - which was focused on radiological measurement parameters, based on the brain’s specimen under an experimental methodology applied to MRI diffusion metrics. Radiological evaluation and optimization of the weighted image diffusion in clinical studies were associated with the brain of the elderly "The Usual Brain Aging" with methodological basis based on established criteria and indicators by Rotterdam Scan Study (RSS). The main results obtained reveal the inexistence frameworks in Portugal for evaluation of equipments or Agency of Health Technology to produce studies comparing the equipment available on the market, the value for money and its allocation to clinical and epidemiological needs. It was found that the implementation of MRI equipment is strongly based on economic criteria lacking recommendations and guidelines for the rationalized use of these technologies. As the quantitative data we conclude that most of the scanners are located in private clinical institutions (80,2%); the most frequent magnetic field intensity is [1.5T] with 119 scanners; the scanners are mainly installed in Lisbon (55 units) and Porto (39 units) districts; the average ratio of equipment per capita in Portugal is 1 to 65 195 people; the gradient power with higher expression in the sample is 30-39mT / m;most of the scanners were installed in the years range [2009-2012 years] with 59 equipment; only 6 clinical placements develop clinical research and the most coils for brain studies are of Array type. The optimization study of diffusion technique revealed, as the assessment of the bvalues, the lower (b = 500 s / mm2 and b = 1000 s / mm 2), promotes an increase in the SI and SNR being this measure related to a higher image quality, however the highest b values (b = 2000 s / mm 2) have a higher CNR (Contrast to Noise-Ratio) and CR (Contrast Ratio), compared to the previous ones. This may provide less anatomical details and, thus, ower image quality, of a normal brain, however can help the interpretation and have advantages in identifying microvascular injuries when doubts persist regarding the differential diagnosis of microvascular disease of lacunar or WMH (White Matter Hyperintensities) status type. Changes on this parameter are Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular particularly reflected in the differences of image quality evaluation in the frontocallosum anatomical area. We conclude from the quantitative assessment of the average concentration of iron (26Fe), in all age groups to the basal ganglia, that the higher concentrations are, in descending order: Nigral Substantia, Globus pallidus, Putamen, Thalamus, Rubio nucleus and Caudate nucleus; that there is a predominance in the concentration of iron (26Fe) in the left hemisphere and that male gender show higher iron (26Fe) level tha females, in the age groups [30-40 [[40-50 [and [50- 60 [. Regarding a main conclusion of the mean concentration study of iron, in terms of age we point out that the average concentration of iron (26Fe) is higher among older groups and increases with age, especially in Nigral Substantia and Lenticular Nucleus. On the technical and radiological study we found evidence of an increased in water /diffusivity in the ubcortical white matter of the elderly compared with younger subjects. A similar relationship was assessed in the Thalamus. The increase agerelated seems to be predominantly observed in patients over 65 years which may reflect minor structural changes associated with normal aging. The results indicate that quantitative analysis of diffusion weighted imaging can provide information about the structure of the brain which is not reached only by visual inspection or standard sequences applied in clinical routine. To address the disadvantages the systems of quantification of WMH which the authors state that are costly, complex, require specific technology and training, we recommend that the automated application GUIAL, developed over our work is basic and practical to use and to be introduced in MR image systems acquisition in order to integrate image processing in patients with vascular risk factors. The evaluation of the ADC showed that its variation is statistically explained by the existence of the medical condition of lacunar status, in both hemispheres, or in other words, the lacunar status influences the ADC value. Although a small percentage of the ADC variation is explained by gender, the ADC in men was higher than women which Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular do not surprise us, since they are also men where the frequency of microvasculardisease has proved more significant. The values of ADC, overall, between the cerebral hemispheres showed no changes but were different in WM among the elderly and non-elderly subjects.The WM's forehead showed decreased values in anisotropy and isotropy face the other anatomical areas. The studies indicate that in old age there is a greater tendency to higher susceptibility to disconnection- status framework. The classification of WMH was higher in elderly people and lacunar status, and fewer (lower classification rating) in the elderly without lacunar status. volumetric changes were more frequent in men than in women, most probably because of its association with high lacunar status rating. An increase of Evan index corresponded, in this study, to an increase in WMH, to a decreased of total brain volume, to a ventricle sulcal frontal and callous angle expansion. These results were wound up by high ranking of lacunar status in subjects who had small vessel disease, clear increase in spaces of Virchow-Robin, lacunar infarctions or WMH. These results were more significant in males than in females revealing vulnerability particularly in the frontal atrophy in men. In turn the size of Corpus Callosum because reduced due to the compression of the lateral and third ventricles. These indicators had expression particularly in individuals over 65 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this note we demonstrate that the use of an index to standardize the fishing effort using the cpue of a standard vessel or gear is mistaken, once the cpues- catch per unit of total effort after standardization is similar to cpues - catch per unit of effort of the standard vesel or gear arbitrarily chosen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The currently available clinical imaging methods do not provide highly detailed information about location and severity of axonal injury or the expected recovery time of patients with traumatic brain injury [1]. High-Definition Fiber Tractography (HDFT) is a novel imaging modality that allows visualizing and quantifying, directly, the degree of axons damage, predicting functional deficits due to traumatic axonal injury and loss of cortical projections. This imaging modality is based on diffusion technology [2]. The inexistence of a phantom able to mimic properly the human brain hinders the possibility of testing, calibrating and validating these medical imaging techniques. Most research done in this area fails in key points, such as the size limit reproduced of the brain fibers and the quick and easy reproducibility of phantoms [3]. For that reason, it is necessary to develop similar structures matching the micron scale of axon tubes. Flexible textiles can play an important role since they allow producing controlled packing densities and crossing structures that match closely the human crossing patterns of the brain. To build a brain phantom, several parameters must be taken into account in what concerns to the materials selection, like hydrophobicity, density and fiber diameter, since these factors influence directly the values of fractional anisotropy. Fiber cross-section shape is other important parameter. Earlier studies showed that synthetic fibrous materials are a good choice for building a brain phantom [4]. The present work is integrated in a broader project that aims to develop a brain phantom made by fibrous materials to validate and calibrate HDFT. Due to the similarity between thousands of hollow multifilaments in a fibrous arrangement, like a yarn, and the axons, low twist polypropylene multifilament yarns were selected for this development. In this sense, extruded hollow filaments were analysed in scanning electron microscope to characterize their main dimensions and shape. In order to approximate the dimensional scale to human axons, five types of polypropylene yarns with different linear density (denier) were used, aiming to understand the effect of linear density on the filament inner and outer areas. Moreover, in order to achieve the required dimensions, the polypropylene filaments cross-section was diminished in a drawing stage of a filament extrusion line. Subsequently, tensile tests were performed to characterize the mechanical behaviour of hollow filaments and to evaluate the differences between stretched and non-stretched filaments. In general, an increase of the linear density causes the increase in the size of the filament cross section. With the increase of structure orientation of filaments, induced by stretching, breaking tenacity increases and elongation at break decreases. The production of hollow fibers, with the required characteristics, is one of the key steps to create a brain phantom that properly mimics the human brain that may be used for the validation and calibration of HDFT, an imaging approach that is expected to contribute significantly to the areas of brain related research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives Unipolar depression (UPD) is a leading cause of global burden of diseases, particularly among the elderly, whose treatment may be challenging. In such cases, ECT is often recommended due to its safety and efficacy. This report presents a case of a 67-year-old male inpatient that developed a rare cardiac complication during ECT. Methods Clinical case report with patient’s consent and bibliographic review. Results A 67-year-old male inpatient with recurrent severe psychotic depression was hospitalized and ECT was indicated after failure of the pharmacological treatment. A comprehensive clinical pre-evaluation revealed only nonspecific ST-segment changes in electrocardiogram. During the 7th ECT session, it was observed transitory ST-segment depression followed by a discrete increase of plasma troponin I. Severe tri-vessel coronary artery stenosis was found and a percutaneous coronary angioplasty was performed, with satisfactory psychiatric and cardiac outcomes. Conclusions Unipolar depression (UPD) and cardiovascular disease are often coexistent conditions, especially among the elderly. In the current case, myocardial ischemia was detected lately during ECT therapy and its treatment allowed the UPD treatment to be completed adequately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Membrane-like scaffolds are suitable to induce regeneration in many and different anatomic sites, such as periodontal membrane, skin, liver and cardiac tissues. In some circumstances, the films should adapt to geometrical changes of the attached tissues, such as in cardiac or blood vessel tissue engineering applications. In this context, we developed stretchable two-dimensional multilayer constructs through the assembling of two natural-based polyelectrolytes, chitosan (CHT) and chondroitin sulphate (CS), using the layer-by-layer methodology. The morphology, topography and the transparency of the films were evaluated. The in- fluence of genipin, a natural-derived cross-linker agent, was also investigated in the control of the mechanical properties of the CHT/CS films. The water uptake ability can be tailored by changing the cross-linker concentration, which influenced the young modulus and ultimate tensile strength. The maximum extension tends to decrease with the increase of genipin concentration, compromising the elastic properties of CHT/CS films: nevertheless using lower cross-linker contents, the ultimate tensile stress is similar to the films not cross-linked but exhibiting a significant higher modulus. The in vitro biological assays showed better L929 cell adhesion and proliferation when using the crosslinked membranes and confirmed the non-cytotoxicity of the CHT/CS films. The developed free-standing biomimetic multilayer could be designed to fulfill specific therapeutic requirements by tuning properties such as swelling, mechanical and biological performances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the initial clinical experience of transmyocardial laser revascularization (TMLR) in patients with severe diffuse coronary artery disease. METHODS: Between February, 1998 and February, 1999, 20 patients were submitted to TMLR at the Heart Institute (InCor), University of São Paulo Medical School, Brazil, isolated or in association with conventional coronary artery bypass graft (CABG). All patients had severe diffuse coronary artery disease, with angina functional class III/IV (Canadian Cardiovascular Society score) unresponsive to medical therapy. Fourteen patients were submitted to TMLR as the sole therapy, whereas 6 underwent concomitant CABG. Fifty per cent of the patients had either been previously submitted to a CABG or to a percutaneous transluminal coronary angioplasty (PTCA). Mean age was 60 years, ranging from 45 to 74 years. RESULTS: All patients had three-vessel disease, with normal or mildly impaired left ventricular global function. Follow-up ranged from 1 to 13 months (mean 6.6 months), with no postoperative short or long term mortality. There was significant symptom improvement after the procedure, with 85% of the patients free of angina, and the remaining 15 % of the patients showing improvement in functional class, as well as in exercise tolerance. CONCLUSION: This novel technique can be considered a low risk alternative for a highly selected group of patients not suitable for conventional revascularization procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The authors analyzed the 30-day and 6-month outcomes of 1,126 consecutive patients who underwent coronary stent implantation in 1996 and 1997. METHODS: The 30-day results and 6-month angiographic follow-up were analyzed in patients treated with coronary stents in 1996 and 1997. All patients underwent coronary stenting with high-pressure implantation (>12 atm) and antiplatelet drug regimen (aspirin plus ticlopidine). RESULTS: During the study period, 1,390 coronary stents were implanted in 1,200 vessels of 1,126 patients; 477 patients were treated in the year 1996 and 649 in 1997. The number of percutaneous procedures performed using stents increased significantly in 1997 compared to 1996 (64 % vs 48%, p=0.0001). The 30-day results were similar in both years; the success and stent thrombosis rates were equal (97% and 0.8%, respectively). The occurrence of new Q wave MI (1.3% vs 1.1%, 1996 vs 1997, p=NS), emergency coronary bypass surgery (1% vs 0.6%, 1996 vs 1997, p=NS) and 30-day death rates (0.2% vs 0.5%, 1996 vs 1997, p=NS) were similar. The 6-month restenosis rate was 25% in 1996 and 27% in 1997 (p= NS); the target vessel revascularization rate was 15% in 1996 and 16% in 1997 (p = NS). CONCLUSIONS: Intracoronary stenting showed a high success rate and a low incidence of 30-day occurrence of new major coronary events in both periods, despite the greater angiographic complexity of the patients treated with in 1997. These adverse variables did not have a negative influence at the 6-month clinical and angiographic follow-up, with similar rates of restenosis and ischemia-driven target lesion revascularization rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction <30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To study the quantitative changes in intramyocardial blood vessels in rats in whom nitric oxide synthesis was inhibited. METHODS: Four groups of 10 rats were studied: control (C25 and C40) and L-NAME (L25 and L40). The animals L25 and L40 received L-NAME in the dosage of 50mg/kg/day for 25 and 40 days, respectively. On days 26 and 41 the animals in groups 25 and 40 were sacrificed. Analysis of the myocardium was performed using light microscopy and stereology. RESULTS: Arterial blood pressure and heart weight increased 74.5 and 57.8% after 25 days and 90.2 and 34.6% after 40 days, respectively. Comparing the L-NAME rats with the respective controls revealed that vessel volume density decreased 31.3% after 40 days, and the vessel length-density decreased 53.5% after 25 days and 25.7% after 40 days. The mean cross-sectional area of the vessels showed an important reduction of 154.6% after 25 days. The intramyocardial vessels decreased significantly in length- density in the L-NAME animals. The mean cross-sectional area of the vessels, which normally increases during heart growth between 25 and 40 days, showed a precocious increase by the 25th day in the L-NAME rats. This suggests an increase of the size of the heart, including blood vessels. CONCLUSION: The inhibition of the NO synthesis provokes rarefaction in the intramyocardial vessels that progresses with the time of administration of L-NAME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary dissection occurs frequently and in several degrees during coronary angioplasty, which is one of the mechanisms for increasing the lumen diameter of a vessel. However the length of the dissection may affect the procedure, becoming the most frequent cause of total occlusion after coronary angioplasty. We report here a case of extensive dissection that occurred during the coronary angioplasty of a focused lesion, which we treated with two long stents.