970 resultados para Ultrasound extractions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of ultrasound on improving the performance of a granular iron Permeable Reactive Barrier (PRB) in the degradation of Trichloroethylene (TCE) was evaluated. Two treatment columns made of clear Plexiglas with a height of 1ft and a diameter of 2 inches and filled with granular iron were used. One was fitted with 25Khz ultrasound probes. A solution of TCE was run through at constant flow rate. Samples obtained from the column at different residence times before and after sonication were analyzed for concentrations of TCE and used to generate concentration profiles to obtain rate constants, which were compared. An improvement of 23.4% in the reaction rate of TCE degradation was observed after sonication of the iron media suggesting that ultrasound may contribute to improving the performance of PRBs in the degradation of TCE in contaminated groundwater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oil industry is one of the activities that generates more waste to the environment. The drill cuttings is a waste generated in large quantities in the drilling process and that may cause environmental damage such as soil contamination and consequently the contamination of groundwater if disposed of without prior treatment. Arises the need to develop scientific activities and research ways to adapt these wastes the current environmental standards. In the case of solid wastes, the NBR 10004: 2004 of the Brazilian Association of Technical Standards (ABNT) classifies them into class I waste (hazardous) and class II (not dangerous), which determines which wastes may or may not be discarded in the environment without causing environmental impact. This study presents a novel alternative for treating drill cuttings, where this waste was classified as class I (Abreu & Souza, 2005), mainly by removing the n-paraffin present in it, since this arises when using drilling fluids base oil. Using microemulsion systems promotes the removal of this contaminant drill cuttings samples from wells located in Alto do Rodrigues - RN. Initially, we determined the concentration of paraffin using infrared method in samples were extracted with ultrasound, we obtained a paraffin concentration in the range from 36.59 to 43.52 g of paraffin per kilogram of cuttings. Used two microemulsion systems containing two nonionic surfactants from different classes, one is an alcohol ethoxylated (UNTL-90) and the other an nonylphenol ethoxylated (RNX 110). The results indicated that the system UNTL-90 surfactant has better efficiency than the system with RNX 110. The study of the influence of contact time at the extraction showed that for times greater than 25 minutes has a tendency to increase the percentage extraction with increasing contact time. It was also observed that the extraction is fast because at 1 minute contact has 22.7% extraction. The reuse of the microemulsion system without removing the paraffin extracted in previous steps, showed reduction of 29.32 in percentage of extraction by comparing the first and third extraction, but by comparing the first and second extractions reduction is 8.5 in percentage extraction, so the systems reuse optimization can be an option for economically viable removing paraffin from cuttings. The extraction with shaking is more effective in the treatment of cuttings, reaching the extraction percentage of 87.04%, that is, obtaining a drill cuttings with 0.551% paraffin. Using the percentage of paraffin employed in non-aqueous drilling fluids and fluid maximum limit on cuttings for disposal established by the Environmental Protection Agency of the United States (US EPA), one arrives at the conclusion that the level of paraffin on gravel cannot exceed 3.93%. Conclude that the amount of paraffin in the treated cuttings with the microemulsion system with shaking is below the established by US EPA, showing that the system used was efficient in removing the paraffin from the drill cuttings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessing the soil nutrient availability to plants under lab conditions is one of the main challenges to Soil Fertility and Chemistry, due to the complex behavior and the interaction of the soil properties. Many extractant solutions associated with mechanical forms of agitation have been proposed, showing different correlations with plant growth and nutrients absorption. Using ultrasonic energy is a agitation procedure of the soil:extractant solution suspension (based on the cavitation phenomenon). It allows the establishment of relations between the amount of extracted nutrient and the ultrasonic energy level. Thus, this work aims: to evaluate the effect of cavitation intensity on the extraction of P, Zn, Cu, Mn and Fe in soil samples from five Latosols under different uses around Uberlândia and Uberaba, Minas Gerais State; to obtain extracting curves as function of ultrasonic energy levels; and to obtain an index from extracting curves to expresses the nutrient retention by the soil solid phase. A soil-solution suspension (ratio 1:10) was sonicated using a probe ultrasound equipment under different combinations of power and time: i) 30 W for 35, 70, 140 and 280 s; ii) 50 W for 21, 42, 84 and 168 s; and iii) 70 W for 15, 30, 60 and 120 s. The extractant solutions used were Mehlich-1 (for all elements), Olsen and distilled water for P. After each sonication, P concentration was quantified by molybdenum blue colorimetric method and Zn, Cu, Mn and Fe by flame atomic absorption spectrophotometry. The cavitation intensity did not affect the P extraction, only the total energy applied. The P extraction was influenced by extractant solution, decreasing as follows: Mehlich-1>Olsen>water. In cultivated Latosols, the P extraction increased linearly with ultrasonic energy, and the slope of the 1:1 linear regression reflects the P retention in the soil. The Zn and Fe extractions were influenced only by total energy applied. Mn and Cu extractions were influenced by both cavitation intensity and total ultrasonic energy. Soils containing similar amounts of P, Cu, Zn, Mn, and Fe may have a different extraction rate. Likewise, soils containing different amounts of those elements may have the same extraction rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To investigate the predictive ability of four digital assessment parameters to detect levator ani (LA) muscle defects (avulsion injury) and compare these to transperineal tomographic ultrasound images. Methods This was an observational study imbedded in a larger quasi-experimental cohort study for women with urinary incontinence. Seventy-two women, ≥60 years who had attended or were going to attend physiotherapy for treatment of urinary incontinence, were included in the study. Inclusion criteria from the parent study were symptoms of stress, urge or both types of urinary incontinence. The predictive ability of the following digital parameters: direct palpation of a discontinuity of the LA muscle from insertion on the pubic ramus; palpation of the distance between the muscle insertion sites; palpation of LA strength; palpation of LA tone, were analyzed against findings from tomographic transperineal ultrasound images. Correlation between methods was measured using Cohen's kappa for each of the individual parameters. Results Seventeen women (24%) presented with a complete or partial avulsion of the puborectalis muscle as diagnosed with tomographic ultrasound imaging. Nine women (13%) had complete avulsions, one of which was bilateral. The predictive ability of the digital assessment parameters varied from poor (k = 0.187, 95% CI [0.02–0.36]) to moderate (k = 0.569, 95% CI [0.31–0.83]). The new parameter of ‘width between insertion sites’ performed best. Conclusions Adding the parameter of “width between insertion sites” appears to enhance our ability to detect avulsion of the levator ani (LA) muscle by digital examination however it does not distinguish between unilateral or bilateral avulsion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work looks at the effect on mid-gap interface state defect density estimates for In0.53Ga0.47As semiconductor capacitors when different AC voltage amplitudes are selected for a fixed voltage bias step size (100 mV) during room temperature only electrical characterization. Results are presented for Au/Ni/Al2O3/In0.53Ga0.47As/InP metal–oxide–semiconductor capacitors with (1) n-type and p-type semiconductors, (2) different Al2O3 thicknesses, (3) different In0.53Ga0.47As surface passivation concentrations of ammonium sulphide, and (4) different transfer times to the atomic layer deposition chamber after passivation treatment on the semiconductor surface—thereby demonstrating a cross-section of device characteristics. The authors set out to determine the importance of the AC voltage amplitude selection on the interface state defect density extractions and whether this selection has a combined effect with the oxide capacitance. These capacitors are prototypical of the type of gate oxide material stacks that could form equivalent metal–oxide–semiconductor field-effect transistors beyond the 32 nm technology node. The authors do not attempt to achieve the best scaled equivalent oxide thickness in this work, as our focus is on accurately extracting device properties that will allow the investigation and reduction of interface state defect densities at the high-k/III–V semiconductor interface. The operating voltage for future devices will be reduced, potentially leading to an associated reduction in the AC voltage amplitude, which will force a decrease in the signal-to-noise ratio of electrical responses and could therefore result in less accurate impedance measurements. A concern thus arises regarding the accuracy of the electrical property extractions using such impedance measurements for future devices, particularly in relation to the mid-gap interface state defect density estimated from the conductance method and from the combined high–low frequency capacitance–voltage method. The authors apply a fixed voltage step of 100 mV for all voltage sweep measurements at each AC frequency. Each of these measurements is repeated 15 times for the equidistant AC voltage amplitudes between 10 mV and 150 mV. This provides the desired AC voltage amplitude to step size ratios from 1:10 to 3:2. Our results indicate that, although the selection of the oxide capacitance is important both to the success and accuracy of the extraction method, the mid-gap interface state defect density extractions are not overly sensitive to the AC voltage amplitude employed regardless of what oxide capacitance is used in the extractions, particularly in the range from 50% below the voltage sweep step size to 50% above it. Therefore, the use of larger AC voltage amplitudes in this range to achieve a better signal-to-noise ratio during impedance measurements for future low operating voltage devices will not distort the extracted interface state defect density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To investigate the predictive ability of four digital assessment parameters to detect levator ani (LA) muscle defects (avulsion injury) and compare these to transperineal tomographic ultrasound images. Methods This was an observational study imbedded in a larger quasi-experimental cohort study for women with urinary incontinence. Seventy-two women, ≥60 years who had attended or were going to attend physiotherapy for treatment of urinary incontinence, were included in the study. Inclusion criteria from the parent study were symptoms of stress, urge or both types of urinary incontinence. The predictive ability of the following digital parameters: direct palpation of a discontinuity of the LA muscle from insertion on the pubic ramus; palpation of the distance between the muscle insertion sites; palpation of LA strength; palpation of LA tone, were analyzed against findings from tomographic transperineal ultrasound images. Correlation between methods was measured using Cohen's kappa for each of the individual parameters. Results Seventeen women (24%) presented with a complete or partial avulsion of the puborectalis muscle as diagnosed with tomographic ultrasound imaging. Nine women (13%) had complete avulsions, one of which was bilateral. The predictive ability of the digital assessment parameters varied from poor (k = 0.187, 95% CI [0.02–0.36]) to moderate (k = 0.569, 95% CI [0.31–0.83]). The new parameter of ‘width between insertion sites’ performed best. Conclusions Adding the parameter of “width between insertion sites” appears to enhance our ability to detect avulsion of the levator ani (LA) muscle by digital examination however it does not distinguish between unilateral or bilateral avulsion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To reconstruct the cycling of reactive phosphorus (P) in the Bering Sea, a P speciation record covering the last ~ 4 Ma was generated from sediments recovered during Integrated Ocean Drilling Program (IODP) Expedition 323 at Site U1341 (Bowers Ridge). A chemical extraction procedure distinguishing between different operationally defined P fractions provides new insight into reactive P input, burial and diagenetic transformations. Reactive P mass accumulation rates (MARs) are ~ 20-110 µmol/cm2/ka, which is comparable to other open ocean locations but orders of magnitude lower than most upwelling settings. We find that authigenic carbonate fluorapatite (CFA) and opal-bound P are the dominant P fractions at Site U1341. An overall increasing contribution of CFA to total P with sediment depth is consistent with a gradual "sink switching" from more labile P fractions (fish remains, Fe oxides, organic matter) to stable authigenic CFA. However, the positive correlation of CFA with Al content implies that a significant portion of the supposedly reactive CFA is non-reactive "detrital contamination" by eolian and/or riverine CFA. In contrast to CFA, opal-bound P has rarely been studied in marine sediments. We find for the first time that opal-bound P directly correlates with excess silica contents. This P fraction was apparently available to biosiliceous phytoplankton at the time of sediment deposition and is a long-term sink for reactive P in the ocean, despite the likelihood for diagenetic re-mobilisation of this P at depth (indicated by increasing ratios of excess silica to opal-bound P). Average reactive P MARs at Site U1341 increase by ~ 25% if opal-bound P is accounted for, but decrease by ~ 25% if 50% of the extracted CFA fraction (based on the lowest CFA value at Site U1341) is assumed to be detrital. Combining our results with literature data, we present a qualitative perspective of terrestrial CFA and opal-bound P deposition in the modern ocean. Riverine CFA input has mostly been reported from continental shelves and margins draining P-rich lithologies, while eolian CFA input is found across wide ocean regions underlying the Northern Hemispheric "dust belt". Opal-bound P burial is important in the Southern Ocean, North Pacific, and likely in upwelling areas. Shifts in detrital CFA and opal-bound P deposition across ocean basins likely occurred over time, responding to changing weathering patterns, sea level, and biogenic opal deposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit  beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit  beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient  digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the  modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP  modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of  modulators topologies, is intended to accelerate the design process and evaluation of  modulators. This design tool is further developed to enable the design, analysis and evaluation of  beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such as stroke volume, ejection fraction, and cardiac output. By repeating the measurements from a subject after a brief exercise period, an increase in stroke volume and ejection fraction are easily demonstrable, potentially with or without an increase in left ventricular end-diastolic volume (which indicates preload). Thus, factors that affect cardiac performance can readily be discussed. This activity may be performed as a practical demonstration and visualized using an overhead projector or networked computers, concentrating on using the ultrasound images to teach basic physiological principles. This has proved to be highly popular with students, who reported a significant improvement in their understanding of Frank-Starling's law of the heart with ultrasound imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Point-of-care ultrasound (POCUS) use in clinical care is growing rapidly, and advocates have recently proposed the integration of ultrasound into undergraduate medical education (UME). The evidentiary basis for this integration has not been evaluated critically or systematically. In this study, we conducted a critical and systematic review framed by the rationales enumerated by advocates of ultrasound in UME in academic publications.

Methods: This research was conducted in two phases. First, the dominant discursive rationales for the integration of ultrasound in UME were identified using techniques from Foucauldian critical discourse analysis (CDA) from an archive of 403 academic publications. We then sought empirical evidence in support of theses rationales, using a critical synthesis methodology also adapted from CDA.

Results: We identified four dominant discursive rationales, with different levels of evidentiary support. Ultrasound was not demonstrated to improve students’ understanding of anatomy. The benefit of ultrasound in teaching physical examination was inconsistent,and rests on minimal evidence. With POCUS, students’ diagnostic accuracy was improved for certain pathologies, but findings were inconsistent for others. Finally, the rationale that ultrasound training in UME will improve quality of patient care was difficult to evaluate.

Discussion: Our analysis has shown that the frequently repeated rationales for the integration of ultrasound in UME are not supported by a sufficient base of empirical research. The repetition of these dominant discursive rationales in academic publications legitimizes them and may preclude further primary research. Since the value of clinical ultrasound use by medical students remains unproven, educators must consider whether the associated financial and temporal costs are justified or whether more research is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

aparoscopic surgery plays today an important role in the diagnosis and staging of abdominal lymphomas; in fact it provides adequate lymph node sampling for histological typing and immunophenotyping. The mini-invasive procedure is safe and effective. Intra-operative ultrasound permits to study the parenchimal organs in addition to intra-abdominal lymph node and/or masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, lipofilling has established itself as one of the most effective and least invasive techniques to treat connective dystrophy subsequent to radiotherapy. We report the case of a patient diagnosed with intraductal carcinoma of the right breast in 1996, at the age of 41. The patient underwent quadrantectomy with ipsilateral axillary lymph node dissection and adjuvant chemotherapy and radiotherapy. Four years later, a recurrence led the patient to undergo a subcutaneous mastectomy and immediate reconstruction, involving the submuscular insertion of a permanent implant. In 2007 the patient suffered both radiodermatitis and capsular contracture around the implant, causing constant pain and significant functional limitation. She first took a leukotriene inhibitor (Zafirlukast, 20 mg daily for 8 months) to reduce the capsular contracture. She then underwent lipofilling (Coleman’s technique) of the area affected by radiodermatitis, in which the skin was considerably thinned and visibly ischemic. A second session followed four months later. Clinical, photographic and ultrasound examination revealed clear and lasting thickening of the superficial tissues, increased coverage of the implant, and reduced skin discoloration and tension.