925 resultados para TRACE validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The present work describes setting up a laboratory unit for supercritical fluid extraction. In addition to its construction, a survey of cost was done to compare the cost of the homemade unit with that of commercial units. The equipment was validated using an extraction of annatto seeds’ oil, and the extraction and fractionation of fennel oil were used to validate the two separators; for both systems, the solvent was carbon dioxide. The chemical profiles of annatto and fennel extracts were assessed using thin layer chromatography; the images of the chromatographic plates were processed using the free ImageJ software. The cost survey showed that the homemade equipment has a very low cost (~US$ 16,000) compared to commercial equipment. The extraction curves of annatto were similar to those obtained in the literature (yield of 3.8% oil). The separators were validated, producing both a 2.5% fraction of fennel seed extract rich in essential oils and another extract fraction composed mainly of oleoresins. The ImageJ software proved to be a low-cost tool for obtaining an initial evaluation of the chemical profile of the extracts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract In Turkey and several Middle East countries' people consume “leblebi” which is a traditional snack food made from chickpeas (Cicer arietinum L.). Chickpea products are highly nutritive and a cheap food for human consumption and have become an essential part of daily diets in the world. The present study aims to determine the chemical, nutritional and dietary composition of fifty leblebi samples marketed in Turkey. Protein values of the leblebi ranged from 19.4 to 23.9% dehulled and 20.3 to 20.8% for nondehulled leblebi while a value of 19.1% was recorded for chickpeas. Mineral results showed that Potassium (K) was the most abundant element in leblebi ranging from 6514 to 14431 mg/kg. The amount of dietary components neutral detergent fibre (NDF), acid detergent fibre (ADF), acid detergent lignin (ADL) and cellulose did not vary much between the samples analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, the power generation is one of the most significant life aspects for the whole man-kind. Barely one can imagine our life without electricity and thermal energy. Thus, different technologies for producing those types of energy need to be used. Each of those technologies will always have their own advantages and disadvantages. Nevertheless, every technology must satisfy such requirements as efficiency, ecology safety and reliability. In the matter of the power generation with nuclear energy utilization these requirements needs to be highly main-tained, especially since accidents on nuclear power plants may cause very long term deadly consequences. In order to prevent possible disasters related to the accident on a nuclear power plant strong and powerful algorithms were invented in last decades. Such algorithms are able to manage calculations of different physical processes and phenomena of real facilities. How-ever, the results acquired by the computing must be verified with experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate cancer (PCa) has emerged as the most commonly diagnosed lethal cancer in European men. PCa is a heterogeneous cancer that in the majority of the cases is slow growing: consequently, these patients would not need any medical treatment. Currently, the measurement of prostate-specific antigen (PSA) from blood by immunoassay followed by digital rectal examination and a pathological examination of prostate tissue biopsies are the most widely used methods in the diagnosis of PCa. These methods suffer from a lack of sensitivity and specificity that may cause either missed cancers or overtreatment as a consequence of over-diagnosis. Therefore, more reliable biomarkers are needed for a better discrimination between indolent and potentially aggressive cancers. The aim of this thesis was the identification and validation of novel biomarkers for PCa. The mRNA expression level of 14 genes including AMACR, AR, PCA3, SPINK1, TMPRSS2-ERG, KLK3, ACSM1, CACNA1D, DLX1, LMNB1, PLA2G7, RHOU, SPON2, and TDRD1 was measured by a truly quantitative reverse transcription PCR in different prostate tissue samples from men with and without PCa. For the last eight genes the function of the genes in PCa progression was studied by a specific siRNA knockdown in PC-3 and VCaP cells. The results from radical prostatectomy and cystoprostatectomy samples showed statistically significant overexpression for all the target genes, except for KLK3 in men with PCa compared with men without PCa. Statistically significant difference was also observed in low versus high Gleason grade tumors (for PLA2G7), PSA relapse versus no relapse (for SPON2), and low versus high TNM stages (for CACNA1D and DLX1). Functional studies and siRNA silencing results revealed a cytotoxicity effect for the knock-down of DLX1, PLA2G7, and RHOU, and altered tumor cell invasion for PLA2G7, RHOU, ACSM1, and CACNA1D knock-down in 3D conditions. In addition, effects on tumor cell motility were observed after silencing PLA2G7 and RHOU in 2D monolayer cultures. Altogether, these findings indicate the possibility of utilizing these new markers as diagnostic and prognostic markers, and they may also represent therapeutic targets for PCa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional business models and the traditionally successful development methods that have been distinctive to the industrial era, do not satisfy the needs of modern IT companies. Due to the rapid nature of IT markets, the uncertainty of new innovations‟ success and the overwhelming competition with established companies, startups need to make quick decisions and eliminate wasted resources more effectively than ever before. There is a need for an empirical basis on which to build business models, as well as evaluate the presumptions regarding value and profit. Less than ten years ago, the Lean software development principles and practices became widely well-known in the academic circles. Those practices help startup entrepreneurs to validate their learning, test their assumptions and be more and more dynamical and flexible. What is special about today‟s software startups is that they are increasingly individual. There are quantitative research studies available regarding the details of Lean startups. Broad research with hundreds of companies presented in a few charts is informative, but a detailed study of fewer examples gives an insight to the way software entrepreneurs see Lean startup philosophy and how they describe it in their own words. This thesis focuses on Lean software startups‟ early phases, namely Customer Discovery (discovering a valuable solution to a real problem) and Customer Validation (being in a good market with a product which satisfies that market). The thesis first offers a sufficiently compact insight into the Lean software startup concept to a reader who is not previously familiar with the term. The Lean startup philosophy is then put into a real-life test, based on interviews with four Finnish Lean software startup entrepreneurs. The interviews reveal 1) whether the Lean startup philosophy is actually valuable for them, 2) how can the theory be practically implemented in real life and 3) does theoretical Lean startup knowledge compensate a lack of entrepreneurship experience. A reader gets familiar with the key elements and tools of Lean startups, as well as their mutual connections. The thesis explains why Lean startups waste less time and money than many other startups. The thesis, especially its research sections, aims at providing data and analysis simultaneously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional business models and the traditionally successful development methods that have been distinctive to the industrial era, do not satisfy the needs of modern IT companies. Due to the rapid nature of IT markets, the uncertainty of new innovations‟ success and the overwhelming competition with established companies, startups need to make quick decisions and eliminate wasted resources more effectively than ever before. There is a need for an empirical basis on which to build business models, as well as evaluate the presumptions regarding value and profit. Less than ten years ago, the Lean software development principles and practices became widely well-known in the academic circles. Those practices help startup entrepreneurs to validate their learning, test their assumptions and be more and more dynamical and flexible. What is special about today‟s software startups is that they are increasingly individual. There are quantitative research studies available regarding the details of Lean startups. Broad research with hundreds of companies presented in a few charts is informative, but a detailed study of fewer examples gives an insight to the way software entrepreneurs see Lean startup philosophy and how they describe it in their own words. This thesis focuses on Lean software startups‟ early phases, namely Customer Discovery (discovering a valuable solution to a real problem) and Customer Validation (being in a good market with a product which satisfies that market). The thesis first offers a sufficiently compact insight into the Lean software startup concept to a reader who is not previously familiar with the term. The Lean startup philosophy is then put into a real-life test, based on interviews with four Finnish Lean software startup entrepreneurs. The interviews reveal 1) whether the Lean startup philosophy is actually valuable for them, 2) how can the theory be practically implemented in real life and 3) does theoretical Lean startup knowledge compensate a lack of entrepreneurship experience. A reader gets familiar with the key elements and tools of Lean startups, as well as their mutual connections. The thesis explains why Lean startups waste less time and money than many other startups. The thesis, especially its research sections, aims at providing data and analysis simultaneously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation ofan Ice Skating Protocol to Predict Aerobic Power in Hockey Players In assessing the physiological capacity of ice hockey players, researchers have often reported the outcomes from different anaerobic skate tests, and the general physical fitness of participants. However, with respect to measuring the aerobic power of ice hockey players, few studies have reported a sport-specific protocol, and currently there is a lack of cohort-specific information describing aerobic power based on evaluations using an on-ice protocol. The Faught Aerobic Skating Test (FAST) uses an on-ice continuous skating protocol to induce a physical stress on a participant's aerobic energy system. The FAST incorporates the principle of increasing workloads at measured time intervals during a continuous skating exercise. Regression analysis was used to determine the estimate of aerobic power within gender and age level. Data were collected on 532 hockey players, (males=384, females=148) ranging in age between 9 and 25 years. Participants completed a laboratory test to measure aerobic power using a modified Bruce protocol, and the on-ice FAST. Regression equations were developed for six male and female, age-specific cohorts separately. The most consistent predictors were weight and final stage completed on the FAST. These results support the application of the FAST to estimate aerobic power among hockey players with R^ values ranging from 0.174 to 0.396 and SEE ranging from 5.65 to 8.58 ml kg' min'' depending on the cohort. Thus we conclude that FAST to be an accurate predictor of aerobic power in age and gender-specific hockey playing cohorts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current classification system for spinal cord injury (SCI) considers only somatic information and neglects autonomic damage after injiuy. Heart rate variability (HRV) has the potential to be a valuable measure of cardiac autonomic control after (SCI). Five individuals with tetraplegia and four able-bodied controls underwent 1 min continuous ECG recordings during rest, after Metoprolol administration (max dose=3x5mg) and after Atropine administration (0.02mg/kg) in both supine and 40° head-up tilt. After Metoprolol administration there was a 61.8% decrease in the LF:HF ratio in the SCI participants suggesting that the LF:HF ratio is a reflection of cardiac sympathetic outflow. After Atropine administration there was a 99.1% decrease in the HF power in the SCI participants suggesting that HF power is highly representative of cardiac parasympathetic outflow. There were no significant differences between the SCI and able-bodied participants. Thus, HRV measures are a valid index of cardiac autonomic control after SCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Linear alkylbenzenes, LAB, formed by the Alel3 or HF catalyzed alkylation of benzene are common raw materials for surfactant manufacture. Normally they are sulphonated using S03 or oleum to give the corresponding linear alkylbenzene sulphonates In >95 % yield. As concern has grown about the environmental impact of surfactants,' questions have been raised about the trace levels of unreacted raw materials, linear alkylbenzenes and minor impurities present in them. With the advent of modem analytical instruments and techniques, namely GCIMS, the opportunity has arisen to identify the exact nature of these impurities and to determine the actual levels of them present in the commercial linear ,alkylbenzenes. The object of the proposed study was to separate, identify and quantify major and minor components (1-10%) in commercial linear alkylbenzenes. The focus of this study was on the structure elucidation and determination of impurities and on the qualitative determination of them in all analyzed linear alkylbenzene samples. A gas chromatography/mass spectrometry, (GCIMS) study was performed o~ five samples from the same manufacturer (different production dates) and then it was followed by the analyses of ten commercial linear alkylbenzenes from four different suppliers. All the major components, namely linear alkylbenzene isomers, followed the same elution pattern with the 2-phenyl isomer eluting last. The individual isomers were identified by interpretation of their electron impact and chemical ionization mass spectra. The percent isomer distribution was found to be different from sample to sample. Average molecular weights were calculated using two methods, GC and GCIMS, and compared with the results reported on the Certificate of Analyses (C.O.A.) provided by the manufacturers of commercial linear alkylbenzenes. The GC results in most cases agreed with the reported values, whereas GC/MS results were significantly lower, between 0.41 and 3.29 amu. The minor components, impurities such as branched alkylbenzenes and dialkyltetralins eluted according to their molecular weights. Their fragmentation patterns were studied using electron impact ionization mode and their molecular weight ions confirmed by a 'soft ionization technique', chemical ionization. The level of impurities present i~ the analyzed commercial linear alkylbenzenes was expressed as the percent of the total sample weight, as well as, in mg/g. The percent of impurities was observed to vary between 4.5 % and 16.8 % with the highest being in sample "I". Quantitation (mg/g) of impurities such as branched alkylbenzenes and dialkyltetralins was done using cis/trans-l,4,6,7-tetramethyltetralin as an internal standard. Samples were analyzed using .GC/MS system operating under full scan and single ion monitoring data acquisition modes. The latter data acquisition mode, which offers higher sensitivity, was used to analyze all samples under investigation for presence of linear dialkyltetralins. Dialkyltetralins were reported quantitatively, whereas branched alkylbenzenes were reported semi-qualitatively. The GC/MS method that was developed during the course of this study allowed identification of some other trace impurities present in commercial LABs. Compounds such as non-linear dialkyltetralins, dialkylindanes, diphenylalkanes and alkylnaphthalenes were identified but their detailed structure elucidation and the quantitation was beyond the scope of this study. However, further investigation of these compounds will be the subject of a future study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanoporous materials with large surface area and well-ordered pore structure have been synthesized. Thiol groups were grafted on the materials' surface to make heavy metal ion pre-concentration media. The adsorption properties ofthe materials were explored. Mercury, gold and silver can be strongly adsorbed by these materials, even in the presence of alkaline earth metal ion. Though the materials can adsorb other heavy metal ions such as lead and copper, they show differential adsorption ability when several ions are present in solution. The adsorption sequence is: mercury> == silver> copper » lead and cadmium. In the second part of this work, the memory effects of mercury, gold, silver and boron were investigated. The addition of 2% L-cysteine and 1% thiourea eliminates the problems of the three metal ions completely. The wash-out time for mercury dropped from more than 20 minutes to 18 seconds, and the wash-out time for gold decreased from more than 30 minutes to 49 seconds. The memory effect of boron can be reduced by the use of mannitol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microbial ichnofossils in volcanic rocks provide a significant record of subsurface microbes and potentially extraterrestrial biosignatures. Here, the textures, mineralogy, and geochemistry of two continental basaltic hydrovolcanic deposits - Reed Rocks and Black Hills - in the Fort Rock Volcanic Field (FRVF) are investigated. Methods include petrographic microscopy, micro and powder X-ray diffraction, SEM/BSE/EDF imaging, energy dispersive spectroscopy, stable isotopes, and X-ray fluorescence. Petrographic analysis revealed granular and tubular textures with biogenic morphologies that include terminal enlargements, septate divisions, branching forms, spiral filaments, and ovoid bodies resembling endolithic microborings described in ocean basalts. They display evidence of behaviour and a geologic context expressing their relative age and syngenicity. Differences in abiotic alteration and the abundance/morphotype assemblage of putative microborings between the sites indicate that water/rock ratio, fluid composition and flux, temperature and secondary phase formation are influences on microboring formation. This study is the first report of reputed endolithic microborings in basalts erupted in a continental lacustrine setting.