944 resultados para THERMAL GRAVIMETRIC ANALYSIS
Resumo:
The lattice parameters extracted from Lebail analysis of neutron powder diffraction data collected between 2 and 300 K have been used to calculate the temperature evolution of the thermal expansion tensor for hopeite, Zn-3(PO4)(2)center dot 2H(2)O, Pnma,Z=4with a= 10.6065(4) angstrom, b = 18.2977(4) angstrom, c= 5.0257(2) A at 275 K. The a lattice parameter shows a negative thermal expansion, the b lattice parameter appears to saturate at 275 K while the c lattice parameter has a more typical positive thermal expansion. At 275 K, the magnitudes of the thermal expansion coefficients are alpha(a) = -1. 1(4) x 10(-5) K-1, alpha(b) = 2.4(9) x 10(-6) K-1 and alpha(c) = 3.6(2) x 10(-1) K-1. Under the conditions of these experiments, hopeite begins to dehydrate to the dihydrate between 300 and 325 K, and between 480 and 500 K the monohydrate is formed. The thermal expansion of the dihydrate has been calculated between 335 and 480 and at 480 K the magnitudes of the thermal expansion coefficients are alpha(a) = 1(2) x 10(-5) K-1, alpha(b) = 4(l) x 10(-6) K-1, alpha(c) = 4(2) x 10(-5) K-1, alpha(beta) = 1 (1) x 10(-1) K-1, and alpha(v) = 2(2) x 10(-1) K-1. The thermal expansion of hopeite is described in terms of its crystal structure and possible dehydration mechanisms for the alpha and beta modifications of hopeite are discussed.
Resumo:
A method is presented which allows thermal inertia (the soil heat capacity times the square root of the soil thermal diffusivity, C(h)rootD(h)), to be estimated remotely from micrometeorological observations. The method uses the drop in surface temperature, T-s, between sunset and sunrise, and the average night-time net radiation during that period, for clear, still nights. A Fourier series analysis was applied to analyse the time series of T-s . The Fourier series constants, together with the remote estimate of thermal inertia, were used in an analytical expression to calculate diurnal estimates of the soil heat flux, G. These remote estimates of C(h)rootD(h) and G compared well with values derived from in situ sensors. The remote and in situ estimates of C(h)rootD(h) both correlated well with topsoil moisture content. This method potentially allows area-average estimates of thermal inertia and soil heat flux to be derived from remote sensing, e.g. METEOSAT Second Generation, where the area is determined by the sensor's height and viewing angle. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
We have developed a new method for the analysis of voids in proteins (defined as empty cavities not accessible to solvent). This method combines analysis of individual discrete voids with analysis of packing quality. While these are different aspects of the same effect, they have traditionally been analysed using different approaches. The method has been applied to the calculation of total void volume and maximum void size in a non-redundant set of protein domains and has been used to examine correlations between thermal stability and void size. The tumour-suppressor protein p53 has then been compared with the non-redundant data set to determine whether its low thermal stability results from poor packing. We found that p53 has average packing, but the detrimental effects of some previously unexplained mutations to p53 observed in cancer can be explained by the creation of unusually large voids. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
A commercial dodecylbenzene (DDB) cable oil was aged at temperatures between 90 and 135 degrees C in air and was analyzed using various analytical techniques including optical and infra-red spectroscopy and dielectric analysis. On ageing, the oil darkened, significant oxidation features were found by infra-red spectroscopy and the acid number, water content and dielectric loss all increased. Ageing in the presence of paper or aluminum did not affect the ageing process, whereas ageing was significantly modified by the presence of copper. An absorption at 680 nm ("red absorbers") was detected by ultra-violet/visible spectroscopy followed by the production of an opaque precipitate. A reaction between copper and the acid generated on ageing is thought to produce copper carboxylates, and X-ray fluorescence confirmed that copper was indeed present in both the aged oil and the precipitate. Significantly, once red absorbers were detected, the dielectric loss increased to catastrophically high values and, therefore, the appearance of these compounds may serve as a useful diagnostic indicator. The development of acidity on ageing appears to be key in initiating the destructive copper conversion reaction and hence the control of oil acidity may be key to prolonging the life of DDB cable oils.
Resumo:
Three mu(1.5)-dicyanamide bridged Mn(II) and Co(II) complexes having molecular formula [Mn(dca)(2)(H2O)(2)](n)center dot(hmt)(n) (1), [Co(dca)(2) (H2O)(2)](n)center dot(hmt)(n) (2) and [Co(dca)(2)(bpds)](n) (3) [dca = dicyanamide; hmt = hexamethylenetetramine; bpds = 4,4'-bipyridyl disulfide] have been synthesized and characterized by single crystal X-ray diffraction study, low temperature (300-2 K) magnetic measurement and thermal behavior. The X-ray diffraction analysis of 1 and 2 reveals that they are isostructural, comprising of 1D coordination polymers [M(dca)(2)(H2O)(2)](n) [M = Mn(II), Co(II) for 1 and 2. respectively] with uncoordinated hmt molecules located among the chains. The [M(dca)(2)(H2O)(2)](n) chains and the lattice hint molecules are connected through H-bonds resulting in a 3D supramolecular architecture. The octahedral N4O2 chromophore surrounding the metal ion forms via two trans located water oxygens and four nitrogens from four nitrile dca. Complex 3 is a 1D chain formed by two mu(1.5)-dca and one bridging bpds. The octahedral N-6 coordination sphere surrounding the cobalt ions comprises four nitrogens from dca and two from bpds. Low temperature magnetic study indicates small antiferromagnetic coupling for all the complexes. Best fit parameters for 1: J = -0.17 cm(-1), g = -2.03 with R = 6.1 x 10(-4), for 2, J = -0.50 cm(-1), and for 3, J = -0.95 cm(-1). (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The synthesis. crystal structure and thermal study of the blue catena-(L-glutamato)-aqua copper(II) monohydrate have been reported. The compound crystallizes in P2(1)2(1)2(1) space group and consists of a polymeric three-dimensional network of copper(II) which is coordinated with the amino nitrogen and the carboxylate oxygen Of L-glutamate, the side chain carboxylate oxygen of a neighbouring L-glutamate and the oxygen of a water molecule in the equatorial position. Weak coordination of two additional glutamate oxygen atoms to both the axial positions Completes a distorted octahedron. The crystal structure shows that the lattice water is stabilized by the formation of strong H-bonding network with the coordinated water molecule. Removal and reabsorption of the water molecule have been studied by thermal analysis.
Resumo:
A combined mathematical model for predicting heat penetration and microbial inactivation in a solid body heated by conduction was tested experimentally by inoculating agar cylinders with Salmonella typhimurium or Enterococcus faecium and heating in a water bath. Regions of growth where bacteria had survived after heating were measured by image analysis and compared with model predictions. Visualisation of the regions of growth was improved by incorporating chromogenic metabolic indicators into the agar. Preliminary tests established that the model performed satisfactorily with both test organisms and with cylinders of different diameter. The model was then used in simulation studies in which the parameters D, z, inoculum size, cylinder diameter and heating temperature were systematically varied. These simulations showed that the biological variables D, z and inoculum size had a relatively small effect on the time needed to eliminate bacteria at the cylinder axis in comparison with the physical variables heating temperature and cylinder diameter, which had a much greater relative effect. (c) 2005 Elsevier B.V All rights reserved.
Resumo:
The effects of high pressure (to 800 MPa) applied at different temperatures (20-70 degreesC) for 20 min on beef post-rigor longissimus dorsi texture were studied. Texture profile analysis showed that when heated at ambient pressure there was the expected increase in hardness with increasing temperature and when pressure was applied at room temperature there was again the expected increase in hardness with increasing pressure. Similar results to those found at ambient temperature were found when pressure was applied at 40 degreesC. However, at higher temperatures, 60 and 70 degreesC it was found that pressures of 200 MPa caused large and significant decreases in hardness. The results found for hardness were mirrored by those for gumminess and chewiness. To further understand the changes in texture observed, intact beef longissimus dorsi samples and extracted myofibrils were both subjected to differential scanning calorimetry after being subjected to the same pressure/temperature regimes. As expected collagen was reasonably inert to pressure and only at temperatures of 60-70 degreesC was it denatured/unfolded. However, myosin was relatively easily unfolded by both pressure and temperature and when pressure denatured a new and modified structure was formed of low thermal stability. Although this new structure had low thermal stability at ambient pressure it still formed in both the meat and myofibrils when pressure was applied at 60 degreesC. It seems unlikely that structurally induced changes can be a major cause of the significant loss of hardness observed when beef is treated at high temperature (60-70 degreesC) and 200 MPa and it is suggested that accelerated proteolysis under these conditions is the major cause. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
The thermal decomposition of the complex K-4[Ni(NO2)6]center dot H2O has been investigated over the temperature range 25-600 degrees C by a combination of infrared spectroscopy, powder X-ray diffraction, FAB-mass spectrometry and elemental analysis. The first stage of reaction is loss of water and isomerisation of one of the coordinated nitro groups to form the complex K-4 [Ni(NO2)(4) (ONO)]center dot NO2. At temperatures around 200 degrees C the remaining nitro groups within the complex isomerise to the chelating nitrite form and this process acts as a precursor to the loss of NO2 gas at temperatures above 270 degrees C. The product, which is stable up to 600 degrees C, is the complex K-4[Ni(ONO)(4)]center dot NO2, where the nickel atom is formally in the +1 oxidation state. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Interpenetrating polymeric networks based on sodium alginate and poly(N-isopropylacrylamide) (PNIPAAm) covalently crosslinked with N,N′-methylenebisacrylamide have been investigated using rheology, thermogravimetry, differential scanning calorimetry, X-ray diffraction measurements and scanning electron microscopy (SEM). An improved elastic response of the samples with a higher PNIPAAm content and increased amount of crosslinking agent was found. The temperature-responsive behaviour of the hydrogel samples was evidenced by viscoelastic measurements performed at various temperatures. It is shown that the properties of these gels can be tuned according to composition, amount of crosslinking agent and temperature changes. X-ray scattering analysis revealed that the hydrophobic groups are locally segregated even in the swollen state whilst cryo-SEM showed the highly heterogeneous nature of the gels.
Resumo:
The adaptive thermal comfort theory considers people as active rather than passive recipients in response to ambient physical thermal stimuli, in contrast with conventional, heat-balance-based, thermal comfort theory. Occupants actively interact with the environments they occupy by means of utilizing adaptations in terms of physiological, behavioural and psychological dimensions to achieve ‘real world’ thermal comfort. This paper introduces a method of quantifying the physiological, behavioural and psychological portions of the adaptation process by using the analytic hierarchy process (AHP) based on the case studies conducted in the UK and China. Apart from three categories of adaptations which are viewed as criteria, six possible alternatives are considered: physiological indices/health status, the indoor environment, the outdoor environment, personal physical factors, environmental control and thermal expectation. With the AHP technique, all the above-mentioned criteria, factors and corresponding elements are arranged in a hierarchy tree and quantified by using a series of pair-wise judgements. A sensitivity analysis is carried out to improve the quality of these results. The proposed quantitative weighting method provides researchers with opportunities to better understand the adaptive mechanisms and reveal the significance of each category for the achievement of adaptive thermal comfort.
Resumo:
Air distribution systems are one of the major electrical energy consumers in air-conditioned commercial buildings which maintain comfortable indoor thermal environment and air quality by supplying specified amounts of treated air into different zones. The sizes of air distribution lines affect energy efficiency of the distribution systems. Equal friction and static regain are two well-known approaches for sizing the air distribution lines. Concerns to life cycle cost of the air distribution systems, T and IPS methods have been developed. Hitherto, all these methods are based on static design conditions. Therefore, dynamic performance of the system has not been yet addressed; whereas, the air distribution systems are mostly performed in dynamic rather than static conditions. Besides, none of the existing methods consider any aspects of thermal comfort and environmental impacts. This study attempts to investigate the existing methods for sizing of the air distribution systems and proposes a dynamic approach for size optimisation of the air distribution lines by taking into account optimisation criteria such as economic aspects, environmental impacts and technical performance. These criteria have been respectively addressed through whole life costing analysis, life cycle assessment and deviation from set-point temperature of different zones. Integration of these criteria into the TRNSYS software produces a novel dynamic optimisation approach for duct sizing. Due to the integration of different criteria into a well- known performance evaluation software, this approach could be easily adopted by designers in busy nature of design. Comparison of this integrated approach with the existing methods reveals that under the defined criteria, system performance is improved up to 15% compared to the existing methods. This approach is interpreted as a significant step forward reaching to the net zero emission building in future.
Resumo:
The solubility of penciclovir (C10N5O3H17) in a novel film formulation designed for the treatment of cold sores was determined using X-ray, thermal, microscopic and release rate techniques. Solubilities of 0.15–0.23, 0.44, 0.53 and 0.42% (w/w) resulted for each procedure. Linear calibration lines were achieved for experimentally and theoretically determined differential scanning calorimetry (DSC) and X-ray powder diffractometry (XRPD) data. Intra- and inter-batch data precision values were determined; intra values were more precise. Microscopy was additionally useful for examining crystal shape, size distribution and homogeneity of drug distribution within the film. Whereas DSC also determined melting point, XRPD identified polymorphs and release data provided relevant kinetics.
Resumo:
Natural-ventilation potential (NVP) value can provide the designers significant information to properly design and arrange natural ventilation strategy at the preliminary or conceptual stage of ventilation and building design. Based on the previous study by Yang et al. [Investigation potential of natural driving forces for ventilation in four major cities in China. Building and Environment 2005;40:739–46], we developed a revised model to estimate the potential for natural ventilation considering both thermal comfort and IAQ issues for buildings in China. It differs from the previous one by Yang et al. in two predominant aspects: (1) indoor air temperature varies synchronously with the outdoor air temperature rather than staying at a constant value as assumed by Yang et al. This would recover the real characteristic of natural ventilation, (2) thermal comfort evaluation index is integrated into the model and thus the NVP can be more reasonably predicted. By adopting the same input parameters, the NVP values are obtained and compared with the early work of Yang et al. for a single building in four representative cities which are located in different climates, i.e., Urumqi in severe cold regions, Beijing in cold regions, Shanghai in hot summer and cold winter regions and Guangzhou in hot summer and warm winter regions of China. Our outcome shows that Guangzhou has the highest and best yearly natural-ventilation potential, followed by Shanghai, Beijing and Urumqi, which is quite distinct from that of Yang et al. From the analysis, it is clear that our model evaluates the NVP values more consistently with the outdoor climate data and thus reveals the true value of NVP.
Resumo:
The probabilistic projections of climate change for the United Kingdom (UK Climate Impacts Programme) show a trend towards hotter and drier summers. This suggests an expected increase in cooling demand for buildings – a conflicting requirement to reducing building energy needs and related CO2 emissions. Though passive design is used to reduce thermal loads of a building, a supplementary cooling system is often necessary. For such mixed-mode strategies, indirect evaporative cooling is investigated as a low energy option in the context of a warmer and drier UK climate. Analysis of the climate projections shows an increase in wet-bulb depression; providing a good indication of the cooling potential of an evaporative cooler. Modelling a mixed-mode building at two different locations, showed such a building was capable of maintaining adequate thermal comfort in future probable climates. Comparing the control climate to the scenario climate, an increase in the median of evaporative cooling load is evident. The shift is greater for London than for Glasgow with a respective 71.6% and 3.3% increase in the median annual cooling load. The study shows evaporative cooling should continue to function as an effective low-energy cooling technique in future, warming climates.