879 resultados para Skinfold thicknesses
Resumo:
This work reports on the results of magnetophotoluminescence (MPL) measurements carried out in a sample containing two Al0.35Ga0.65As/GaAs, coupled double quantum wells (CDQWs), with inter-well barriers of different thicknesses, which have the heterointerfaces characterized by a distribution of bimodal roughness. The MPL measurements were performed at 4 K, with magnetic fields applied parallel to the growth direction, and varying from 0 to 12 T. The diamagnetic shift of the photoluminescence (PL) peaks is more sensitive to changes in the confinement potential, due to monolayer variations in the mini-well thickness, rather than to the exciton localization at the local potential fluctuations. As the magnetic field increases, the relative intensities of the two peaks in each PL band inverts, what is attributed to the reduction in the radiative lifetime of the delocalized excitons, which results in the radiative recombination, before the excitonic migration between the higher and lower energy regions in each CDQW occurs. The dependence of the full width at half maximum (FWHM) on magnetic field shows different behaviors for each PL peak, which are attributed to the different levels and correlation lengths of the potential fluctuations present in the regions associated with each recombination channel. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Abstract Objectives In this work we investigated how immunological dysfunction and malnutrition interact in alcoholic and viral aetiologies of cirrhosis. Methods To investigate the matter, 77 cirrhotic patients divided in three aetiologies [Alcohol, HCV and Alcohol + HCV) and 32 controls were prospectivelly and sequentially studied. Parameters of humoral immunity (Components 3 and 4 of seric complement and immunoglobulins A M, G and E) and of cellular immunity (total leukocytes and lymphocytes in peripheral blood, T lymphocytes subpopulations, CD4+ and CD8+, CD4+/CD8+ ratio and intradermic tests of delayed hypersensitivity), as well as nutrititional parameters: anthropometric measures, serum albumin and transferrin were evaluated. Results Multiple statistical comparisons showed that IgM was higher in HCV group; IgG was significantly elevated in both HCV and Alcohol + HCV, whereas for the Alcohol group, IgE was found at higher titles. The analysis of T- lymphocytes subpopulations showed no aetiologic differences, but intradermic tests of delayed hypersensitivity did show greater frequency of anergy in the Alcohol group. For anthropometric parameters, the Alcohol +HCV group displayed the lowest triceps skinfold whereas creatinine – height index evaluation was more preserved in the HCV group. Body mass index, arm muscle area and arm fat area showed that differently from alcohol group, the HCV group was similar to control. Conclusion Significant differences were found among the main aetiologies of cirrhosis concerning immunological alterations and nutritional status: better nutrition and worse immunology for HCV and vice-versa for alcohol.
Resumo:
This study evaluated whether periodontal ligament (PL) thickness varied with root size and examined the possible influence of this variation on orthodontic mechanics. Measurements were taken of the maxillary left first molar in 54 male Wistar rats. Mean mesial and distal PL thicknesses were compared between the intermediate buccal and mesiobuccal roots using paired Student's t-tests with a 5% significance level. Mean values differed significantly between roots (p < 2.2 × 10-16). PL thickness in rats is directly proportional to root dimensions
Resumo:
Objectives: The objective of this study is to compare subjective image quality and diagnostic validity of cone-beam CT (CBCT) panoramic reformatting with digital panoramic radiographs. Materials and methods: Four dry human skulls and two formalin-fixed human heads were scanned using nine different CBCTs, one multi-slice CT (MSCT) and one standard digital panoramic device. Panoramic views were generated from CBCTs in four slice thicknesses. Seven observers scored image quality and visibility of 14 anatomical structures. Four observers repeated the observation after 4 weeks. Results: Digital panoramic radiographs showed significantly better visualization of anatomical structures except for the condyle. Statistical analysis of image quality showed that the 3D imaging modalities (CBCTs and MSCT) were 7.3 times more likely to receive poor scores than the 2D modality. Yet, image quality from NewTom VGi® and 3D Accuitomo 170® was almost equivalent to that of digital panoramic radiographs with respective odds ratio estimates of 1.2 and 1.6 at 95% Wald confidence limits. A substantial overall agreement amongst observers was found. Intra-observer agreement was moderate to substantial. Conclusions: While 2D-panoramic images are significantly better for subjective diagnosis, 2/3 of the 3D-reformatted panoramic images are moderate or good for diagnostic purposes. Clinical relevance: Panoramic reformattings from particular CBCTs are comparable to digital panoramic images concerning the overall image quality and visualization of anatomical structures. This clinically implies that a 3D-derived panoramic view can be generated for diagnosis with a recommended 20-mm slice thickness, if CBCT data is a priori available for other purposes.
Resumo:
The growing demand for knowledge about the effect of high temperatures on structures has stimulated increasing research worldwide. This article presents experimental results for short composite steel and concrete columns subjected to high temperatures in ovens with or without an axial compression load, numerically analyzes the temperature distribution in these columns after 30 and 60 minutes and compares them with experimental results. The models consist of concrete-filled tubes of three different thicknesses and two different diameters, and the concrete fill has conventional properties that remained constant for all of the models. The stress-strain behavior of the composite columns was altered after exposure to high temperatures relative to the same columns at room temperature, which was most evident in the 60-minute tests due to the higher temperatures reached. The computational analysis adopted temperature rise curves that were obtained experimentally.
Resumo:
INTRODUÇÃO: A partir da década de 1990 foram iniciados os primeiros tratamentos cirúrgicos da obesidade em adolescentes, seguindo a sequência cirurgia bariátrica, perda ponderal e dismorfismo corporal, criando demanda por cirurgias plásticas para readequação do contorno corporal. O objetivo deste estudo foi identificar fatores associados a cirurgias plásticas de readequação de contorno corporal (morbidade e mortalidade), realizadas em pacientes submetidos a cirurgia bariátrica durante a adolescência. MÉTODO: Entre janeiro de 2008 e janeiro de 2011, 5 pacientes submetidos a gastroplastia redutora durante a adolescência, com consequente perda e estabilização de peso, foram submetidos a cirurgias plásticas do contorno corporal. A média de idade no início das cirurgias plásticas foi de 19,7 anos, sendo 3 (60%) pacientes do sexo feminino. Foram realizadas dermolipectomias abdominais em todos (100%) os pacientes, dermolipectomias crurais em 4 (80%), dermolipectomias braquiais em 2 (40%), mamoplastia com inclusão de implantes de silicone em 2 (40%) pacientes do sexo feminino, mastopexia na terceira paciente do sexo feminino (20%) e correção de ginecomastia em 1 (20%), toracoplastia em 2 (40%), torsoplastia em 2 (40%) e torsoplastia reversa em 1 (20%). Foram realizadas, em média, 3 intervenções cirúrgicas por paciente, sendo operados 20 sítios cirúrgicos. RESULTADOS: Ocorreram deiscências em 3 (15% dos sítios cirúrgicos) casos e foi necessário revisar a ressecção dermogordurosa por flacidez residual em 3 (15% dos sítios cirúrgicos) casos. CONCLUSÕES: Foram identificados alguns fatores associados às cirurgias plásticas de readequação de contorno corporal na amostra de 5 pacientes submetidos a cirurgia bariátrica durante a adolescência, comparáveis aos da literatura específica.
Resumo:
This paper discusses the theoretical and experimental results obtained for the excitonic binding energy (Eb) in a set of single and coupled double quantum wells (SQWs and CDQWs) of GaAs/AlGaAs with different Al concentrations (Al%) and inter-well barrier thicknesses. To obtain the theoretical Eb the method proposed by Mathieu, Lefebvre and Christol (MLC) was used, which is based on the idea of fractional-dimension space, together with the approach proposed by Zhao et al., which extends the MLC method for application in CDQWs. Through magnetophotoluminescence (MPL) measurements performed at 4 K with magnetic fields ranging from 0 T to 12 T, the diamagnetic shift curves were plotted and adjusted using two expressions: one appropriate to fit the curve in the range of low intensity fields and another for the range of high intensity fields, providing the experimental Eb values. The effects of increasing the Al% and the inter-well barrier thickness on Eb are discussed. The Eb reduction when going from the SQW to the CDQW with 5 Å inter-well barrier is clearly observed experimentally for 35% Al concentration and this trend can be noticed even for concentrations as low as 25% and 15%, although the Eb variations in these latter cases are within the error bars. As the Zhao's approach is unable to describe this effect, the wave functions and the probability densities for electrons and holes were calculated, allowing us to explain this effect as being due to a decrease in the spatial superposition of the wave functions caused by the thin inter-well barrier.
Resumo:
Tantalum coatings are of particular interest today as promising candidates to replace potentially hazardous electrodeposited chromium coatings for tribological and corrosion resistant applications, such as the internal lining on large-caliber gun barrels. Tantalum coatings have two crystalline phases, α-Ta (body-centered-cubic) and β-Ta (metastable tetragonal) that exhibit relatively different properties. Alpha-Ta is typically preferred for wear and corrosion resistant applications and unfortunately, is very difficult to deposit without the assistance of substrate heating or post-annealing treatments. Furthermore, there is no general consensus on the mechanism which causes α or β to form or if there is a phase transition or transformation from β → α during coating deposition. In this study, modulated pulsed power (MPP) magnetron sputtering was used to deposit tantalum coatings with thicknesses between 2 and 20 μm without external substrate heating. The MPP Ta coatings showed good adhesion and low residual stress. This study shows there is an abrupt β → α phase transition when the coating is 5–7 μm thick and not a total phase transformation. Thermocouple measurements reveal substrate temperature increases as a function of deposition time until reaching a saturation temperature of ~ 388 °C. The importance of substrate temperature evolution on the β → α phase transition is also explained.
Resumo:
Ultra-thin (thicknesses of 50-90 nm) nanocomposite films of cobalt ferrite nanoparticles (np-CoFe2O4, 18 nm in diameter) and polyelectrolytes (doped polyaniline-PANI, poly-3,4-ethylenedioxy thiophene: polystyrene sulfonic acid-PEDOT:PSS, and sulfonated lignin-SL) are assembled layer-by-layer onto interdigitated microelectrodes aiming at to create novel nanostructured sensoactive materials for liquid media chemical sensors. The nanocomposites display a distinctive globular morphology with nanoparticles densely-packed while surrounded by polyelectrolytes. Due to the presence of np-CoFe2O4 the nanocomposites display low electrical conductivity according to impedance data. On the other hand, this apparent shortcoming turns such nanocomposites much more sensitive to the presence of ions in solution than films made exclusively of conducting polyelectrolytes. For example, the electrical resistance of np-CoFe2O4/PEDOT:PSS and PANI/SL/np-CoFe2O4/SL architectures has a 10-fold decrease when they are immersed in 20 mmol. L-1 NaCl solution. Impedance spectra fitted with the response of an equivalent circuit model suggest that the interface created between nanoparticles and polyelectrolytes plays a major role on the nanocomposites electrical/dielectrical behavior. Since charge transport is sensitive to nanoparticle-polyelectrolyte interfaces as well as to the physicochemical conditions of the environment, the np-CoFe2O4-based nanocomposites can be used as sensing elements in chemical sensors operated under ac regime and room temperature.
Resumo:
We present the synthesis of a copolymer structure, poly(9,9′-n-di-hexyl-2,7-fluorene-alt-2,5- bithiophene), referred to herein as LaPPS43, and its physico-chemical characterization. Thin films of this polymer mixed with phenyl-C61-butyric acid methyl ester (PCBM) were used as the active layer in photovoltaic devices using the ITO/PEDOT:PSS/LaPPS43: PCBM/Ca/Al bulk heterojunction structure. The devices of different active layer thicknesses were electrically studied using J-V curves and the Photo-Celiv technique. The obtained results show that LaPPS43 combined with PCBM is a promising system for photovoltaic devices. Device performance is discussed in terms of the mean drift distance x for charge carriers. Photophysical data showed that the excitonic species are all localized in the aggregated forms. The mechanism of exciton formation and dissociation is also discussed.
A 2D BEM-FEM approach for time harmonic fluid-structure interaction analysis of thin elastic bodies.
Resumo:
[EN]This paper deals with two-dimensional time harmonic fluid-structure interaction problems when the fluid is at rest, and the elastic bodies have small thicknesses. A BEM-FEM numerical approach is used, where the BEM is applied to the fluid, and the structural FEM is applied to the thin elastic bodies.
Resumo:
Monte Carlo-Simulationen zum kritischen Verhalten dünnerIsing-Filme Dünne Ising-Filme können als vereinfachtes Modell zurBeschreibung von binären Mischungen oder von Flüssigkeitenin schlitzartigen Kapillaren dienen. Infolge dereingeschränkten Geometrie unterscheidet sich das kritischeVerhalten dieser Systeme signifikant von dem einesBulk-Systems, es kommt zu einem Crossover von zwei- zudreidimensionalem kritischen Verhalten. Zusätzlichverschiebt sich der Phasenübergang in den ungesättigtenBereich, ein Effekt, der als 'capillary condensation'bezeichnet wird. In der vorliegenden Arbeit wurden die kritischenEigenschaften von Ising-Filmen im Rahmen einer MonteCarlo-Simulation untersucht. Zur Verbesserung der Effizienzwurde ein Cluster-Algorithmus verwendet, der um einenGhost-Spin-Term zur Behandlung der Magnetfelder erweitertwar. Bei der Datenanalyse kamen moderneMulti-Histogramm-Techniken zur Anwendung. Für alle untersuchten Schichtdicken konnten kritischeTemperatur und Magnetfeld sehr präzise bestimmt werden. DieSkalenhypothese von Fisher und Nakanishi, die dieVerschiebung des kritischen Punktes gegenüber seinesBulk-Wertes beschreibt, wurde sowohl für Systeme mit freienOberflächen als auch für Systeme mit schwachemOberflächenfeld bestätigt. Der Wert des Gap-Exponenten derOberfläche wurde mit $Delta_1$=0.459(13) in Übereinstimmungmit den Literaturwerten abgeschätzt. Die Observablen Magnetisierung und magnetischeSuszeptibilität sowie deren auf die Oberfläche bezogenenEntsprechungen zeigen kein reines zweidimensionaleskritisches Verhalten. Zu ihrer Beschreibung in der Nähe deskritischen Punktes wurden effektive Exponenten für dieeinzelnen Schichtdicken bestimmt.
Resumo:
The research interest of this study is to investigate surface immobilization strategies for proteins and other biomolecules by the surface plasmon field-enhanced fluorescence spectroscopy (SPFS) technique. The recrystallization features of the S-layer proteins and the possibility of combining the S-layer lattice arrays with other functional molecules make this protein a prime candidate for supramolecular architectures. The recrystallization behavior on gold or on the secondary cell wall polymer (SCWP) was recorded by SPR. The optical thicknesses and surface densities for different protein layers were calculated. In DNA hybridization tests performed in order to discriminate different mismatches, recombinant S-layer-streptavidin fusion protein matrices showed their potential for new microarrays. Moreover, SCWPs coated gold chips, covered with a controlled and oriented assembly of S-layer fusion proteins, represent an even more sensitive fluorescence testing platform. Additionally, S-layer fusion proteins as the matrix for LHCII immobilization strongly demonstrate superiority over routine approaches, proving the possibility of utilizing them as a new strategy for biomolecular coupling. In the study of the SPFS hCG immunoassay, the biophysical and immunological characteristics of this glycoprotein hormone were presented first. After the investigation of the effect of the biotin thiol dilution on the coupling efficiently, the interfacial binding model including the appropriate binary SAM structure and the versatile streptavidin-biotin interaction was chosen as the basic supramolecular architecture for the fabrication of a SPFS-based immunoassay. Next, the affinity characteristics between different antibodies and hCG were measured via an equilibrium binding analysis, which is the first example for the titration of such a high affinity interaction by SPFS. The results agree very well with the constants derived from the literature. Finally, a sandwich assay and a competitive assay were selected as templates for SPFS-based hCG detection, and an excellent LOD of 0.15 mIU/ml was attained via the “one step” sandwich method. Such high sensitivity not only fulfills clinical requirements, but is also better than most other biosensors. Fully understanding how LHCII complexes transfer the sunlight energy directionally and efficiently to the reaction center is potentially useful for constructing biomimetic devices as solar cells. After the introduction of the structural and the spectroscopic features of LHCII, different surface immobilization strategies of LHCII were summarized next. Among them the strategy based on the His-tag and the immobilized metal (ion) affinity chromatography (IMAC) technique were of great interest and resulted in different kinds of home-fabricated His-tag chelating chips. Their substantial protein coupling capacity, maintenance of high biological activity and a remarkably repeatable binding ability on the same chip after regeneration was demonstrated. Moreover, different parameters related to the stability of surface coupled reconstituted complexes, including sucrose, detergent, lipid, oligomerization, temperature and circulation rate, were evaluated in order to standardize the most effective immobilization conditions. In addition, partial lipid bilayers obtained from LHCII contained proteo-liposomes fusion on the surface were observed by the QCM technique. Finally, the inter-complex energy transfer between neighboring LHCIIs on a gold protected silver surface by excitation with a blue laser (λ = 473nm) was recorded for the first time, and the factors influencing the energy transfer efficiency were evaluated.
Resumo:
Gegenstand dieser Arbeit ist die Untersuchung von Photokathoden mit negativer Elektronenaffinität (NEA) mittels zeitlich hochauflösender Vermessung der emittierten Ladungs- und Spinpolarisationsverteilungen nach Anregung mit einem ultrakurzen Laserpuls.
Untersucht wurden uniaxial deformierte GaAsP-Photokathoden mit dünnen emittierenden Schichten (≤150nm), sowie undeformierte GaAs-Photokathoden mit unterschiedlichen Schichtdicken.
Die Untersuchungen wurden an einer 100keV-Elektronenquelle durchgeführt, wie sie am Mainzer Mikrotron (MAMI) zur Erzeugung eines Spinpolarisierten Elektronenstrahls verwendet wird. Mit der Apparatur konnte eine Zeitauflösung von 2,5ps erreicht werden.
Es zeigte sich, dass die tatsächliche Antwortzeit der Photokathoden die erreichte Zeitauflösung noch unterschreitet. Eine Depolarisation in den kurzen, wegen der Zeitauflösung auf 2,5ps begrenzten, Elektronenpulsen konnte aber nachgewiesen werden. Weiterhin wurde gezeigt, dass der Polarisationsverlust der emittierten Elektronen bei dünnen Schichten im Wesentlichen auf eine energiekorrelierte Depolarisation beim Durchqueren der Bandbiegungszone zurückzuführen ist. Als weiteres Resultat wird, für die GaAsP-Photokathoden mit einer Schichtdicke von 150nm, eine Obergrenze für die mittlere Emissionszeit von
Resumo:
Ziel war Herstellung und Charakterisierung festkörperunterstützter Membransysteme aus Glykolipopolymeren auf Goldoberflächen, mit elektrischen Eigenschaften, die denen der Schwarzfilmmembranen entsprechen. Um diese Eigenschaften mit impedanzspektroskopischen Techniken messen zu können, ist die Präparation der Membranen auf Goldfilmen notwendig. Eine direkte Verankerung der Glykolipopolymermoleküle (GLP) auf der Goldoberfläche ist nicht möglich, daher werden die untersuchten GLP mit Hilfe von photoreaktiven Molekülen kovalent auf der Goldoberfläche immobilisiert. Untersuchten Abstandhalter waren Thio-Polyethylenglykol und eine Mischung zweier Alkanthiole, bestehend aus 1-Thiohexanol und Bis-(Aminododecyl)-disulfid. Thio-PEG-Monoschichten zeigten sehr unterschiedliche Schichtdicken, weil die Moleküle auf der Oberfläche sehr unterschiedliche Konformationen annehmen können, die eine regelmässige Anordnung erschweren. Langmuir-Blodgett Übertrag sowie die durchgeführte photochemische Fixierung der GLP-Moleküle auf Thio-PEG Schichten führte zu Eigenschaften, die auf den Aufbau einer Lipidmonolage hinweisen. Diese stellte jedoch im Bereich der Lipidmoleküle keine geschlossene Schicht dar. Es kommen als Abstandhaltermoleküle für die Photofunktionalisierung nur Moleküle in Frage, die aufgrund ihrer Eigenschaften eine regelmässige Anordnung auf der Goldoberfläche anstreben. Diese Voraussetzung erfüllt am besten die Gruppe der Alkanthiole. Terminal funktionalisierte Alkanthiole müssen jedoch mit nicht oder anderweitig funktionalisierten Alkanthiolen verdünnt assembliert werden, um weitergehende Funktionalisierungen einzugehen. Die untersuchten GLP lassen sich aufgrund ihrer amphiphilen Struktur an der Wasser-Luft Grenzfläche vororientieren. In allen Fällen gelingt auch der Langmuir-Blodgett Übertrag der komprimierten Schicht, sowie, nach der für die Anbindung notwendigen Trocknung, die photochemisch kovalente Fixierung der Monoschicht durch Bestrahlung mit UV-Licht. Damit konnte erstmals die photochemisch kovalente Fixierung von GLPs auf der Goldoberfläche gezeigt werden. Untersuchungen erfolgten an einem Copolymer sowie zwei unterschiedlichen Homopolymermolekülen. Der unterschiedliche molekulare Aufbau der GLP spiegelt sich in ihrem Verhalten an der Wasser-Luft Grenzfläche sowie in den Eigenschaften der gebildeten Monoschichten wieder. Die Copolymer-Schichten zeigten sehr unterschiedliche Schichtdicken. Auch die EIS-Daten sind schlecht reproduzierbar. Dies ist auf die molekulare Struktur des Copolymers zurückzuführen. Gänzlich unterschiedlich verhalten sich die Homopolymere. Aufgrund ihrer Struktur lassen sie sich zu dichten Schichten komprimieren. Messungen der Fluoreszenzerholung nach Photobleichung (FRAP) zeigen homogene aber nicht fluide Schichten. Die photochemisch kovalente Fixierung des Moleküls auf der Goldoberfläche konnte durch SPR- sowie EIS-Messungen nachgewiesen werden. Die EIS-Messungen zeigen Werte, die sich in Bereichen der idealen Modellmembran bewegen. Der erfolgreiche Einbau von Valinomycin konnte bestätigt werden. FRAP Untersuchungen zeigten die Bildung homogener Schichten. Diese sind jedoch im Bereich der proximalen Lipidschicht nicht fluide. Um die Fluidität in Anlehnung an die Eigenschaften der natürlichen Membranen zu erhöhen, wurden die photochemisch kovalent fixierten Anker-Glykolipopolymer-Moleküle durch Mischung mit freien Lipiden lateral verdünnt. Auch die kovalente Fixierung der GLP-Bausteine innerhalb gemischten Schichten konnte erfolgreich demonstriert werden. Die Schichten zeigten sich jedoch, mit Ausnahme der Schichten aus 50mol% Homopolymer und 50mol% Lipid, inhomogen. Nach Photobleichung durch den Laserblitz kam es nur bei den 50mol%:50mol% -Schichten (Ho: Lipid) zur Erholung der Fluoreszenz, was auf das Vorliegen von beweglichen Lipidmolekülen innerhalb der Membran schliessen lässt. Der Versuch der Inkorporation von Valinomycin gelang ebenfalls. Alle genannten Ergebnisse deuten darauf hin, dass die molekulare Architektur der hergestellten Schichten durch die unterschiedlichen Längendimensionen des Homopolymer-Moleküls einerseits, sowie des Lipids andererseits nicht für alle Mischungsverhältnisse ausreichend stabil ist. Die für die kovalente Fixierung erforderliche Trocknung der Schicht führt zu einer deutlichen Verminderung des Wassergehaltes des Systems und einer daraus resultierenden starken Destabilisierung der aufgebauten Schichten. Insgesamt gesehen stellt somit die photochemische Fixierung der glykosidischen Homopolymer-Membranen ein vielversprechendes Modellsystem dar.