999 resultados para Sinusoidal component


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the study of the so called Generalized Symmetrical Components, proposed by Tenti et. al. to the analysis of unbalanced periodic non sinusoidal three phase systems. As a result, it was possible to establish a proper relationship between such of generalized symmetrical components and Fortescue symmetrical components to the harmonic frequencies that compose a generic periodic non sinusoidal three phase system. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We evaluated the presence of ductal carcinoma in situ (DCIS) in core needle biopsies (CNB) from invasive ductal lesions. Methods: Retrospective study, which analyzed 90 cases of invasive ductal carcinoma lesions. The percentage of DCIS was quantified in each specimens obtained from CNB, which were compared to the surgical specimens. CNB and surgical specimens were evaluated by the same pathologist, and the percentage of DCIS in CNB was evaluated (percentage) and divided into categories. We considered the following parameters regarding the amount of DCIS: 1 = 0; 2 = 1 for 5%; 3 = 6 for 24%; 4 = 25 for 50%; 5 = 51 for 75% and 6 = 76 for 99%. The number of fragments and the histological pattern of DCIS was found. Results: We found the following results regarding the distribution of the percentage of DCIS in the CNB: 1 = 63.3%; 2 = 12.2%; 3 = 12.2%; 4 = 5.6%; 5 = 1.1% and 6 = 5.6%. The logistic regression analysis showed that CNB percentages above 45% reflected the presence of DCIS in the surgical specimen in 100% of the cases (p<0.001), with a specificity of 100%, accuracy of 83.3% and false positive rate of 0% (p <0.001). Conclusion: There is direct relationship between extensive intraductal component in the surgical specimen when the core biopsy shows 45% or more of the DCI or microinvasive in the material examined. © 2012 Barbalaco Neto et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a practical experimentation for comparing reactive/non-active energy measures, considering three-phase four-wire non-sinusoidal and unbalanced circuits, involving five different commercial electronic meters. The experimentation set provides separately voltage and current generation, each one with any waveform involving up to fifty-first harmonic components, identically compared with acquisitions obtained from utility. The experimental accuracy is guaranteed by a class A power analyzer, according to IEC61000-4-30 standard. Some current and voltage combination profiles are presented and confronted with two different references of reactive/non-active calculation methodologies; instantaneous power theory and IEEE 1459-2010. The first methodology considers the instantaneous power theory, present into the advanced mathematical internal algorithm from WT3000 power analyzer, and the second methodology, accomplish with IEEE 1459-2010 standard, uses waveform voltage and current acquisition from WT3000 as input data for a virtual meter developed on Mathlab/Simulink software. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The relationship between normal and tangential force components (grip force - GF and load force - LF, respectively) acting on the digits-object interface during object manipulation reveals neural mechanisms involved in movement control. Here, we examined whether the feedback type provided to the participants during exertion of LF would influence GF-LF coordination and task performance. Methods. Sixteen young (24.7 ±3.8 years-old) volunteers isometrically exerted continuously sinusoidal FZ (vertical component of LF) by pulling a fixed instrumented handle up and relaxing under two feedback conditions: targeting and tracking. In targeting condition, FZ exertion range was determined by horizontal lines representing the upper (10 N) and lower (1 N) targets, with frequency (0.77 or 1.53 Hz) dictated by a metronome. In tracking condition, a sinusoidal template set at similar frequencies and range was presented and should be superposed by the participants' exerted FZ. Task performance was assessed by absolute errors at peaks (AEPeak) and valleys (AEValley) and GF-LF coordination by GF-LF ratios, maximum cross-correlation coefficients (r max), and time lags. Results: The results revealed no effect of feedback and no feedback by frequency interaction on any variable. AE Peak and GF-LF ratio were higher and rmax lower at 1.53 Hz than at 0.77 Hz. Conclusion: These findings indicate that the type of feedback does not influence task performance and GF-LF coordination. Therefore, we recommend the use of tracking tasks when assessing GF-LF coordination during isometric LF exertion in externally fixed instrumented handles because they are easier to understand and provide additional indices (e.g., RMSE) of voluntary force control. © 2013 Pedão et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phenotypic data from female Canchim beef cattle were used to obtain estimates of genetic parameters for reproduction and growth traits using a linear animal mixed model. In addition, relationships among animal estimated breeding values (EBVs) for these traits were explored using principal component analysis. The traits studied in female Canchim cattle were age at first calving (AFC), age at second calving (ASC), calving interval (CI), and bodyweight at 420 days of age (BW420). The heritability estimates for AFC, ASC, CI and BW420 were 0.03±0.01, 0.07±0.01, 0.06±0.02, and 0.24±0.02, respectively. The genetic correlations for AFC with ASC, AFC with CI, AFC with BW420, ASC with CI, ASC with BW420, and CI with BW420 were 0.87±0.07, 0.23±0.02, -0.15±0.01, 0.67±0.13, -0.07±0.13, and 0.02±0.14, respectively. Standardised EBVs for AFC, ASC and CI exhibited a high association with the first principal component, whereas the standardised EBV for BW420 was closely associated with the second principal component. The heritability estimates for AFC, ASC and CI suggest that these traits would respond slowly to selection. However, selection response could be enhanced by constructing selection indices based on the principal components. © CSIRO 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A seletividade espacial para cor tem sido investigada usando métodos eletrofisiológicos invasivos e não invasivos, e métodos psicofísicos. Em eletrofisiologia cortical visual não invasiva este tópico foi investigado usando métodos convencionais de estimulação periódica e extração de respostas por promediação simples. Novos métodos de estimulação (apresentação pseudo-aleatória) e extração de respostas corticais não invasivas (correlação cruzada) foram desenvolvidos e ainda não foram usados para investigar a seletividade espacial de cor de respostas corticais. Este trabalho objetivou introduzir esse novo método de eletrofisiologia pseudoaleatória para estudar a seletividade espacial de cor. Foram avaliados 14 tricromatas e 16 discromatópsicos com acuidade visual normal ou corrigida. Os voluntários foram avaliados pelo anomaloscópio HMC e teste de figuras de Ishihara para caracterizar a visão de cores quanto à presença de tricromacia. Foram usadas redes senoidais, 8º de ângulo visual, vermelho-verde para 8 frequências espaciais entre 0,2 a 10 cpg. O estímulo foi temporalmente modulado por uma sequência-m binária em um modo de apresentação de padrão reverso. O sistema VERIS foi usado para extrair o primeiro e o segundo slice do kernel de segunda ordem (K2.1 e K2.2, respectivamente). Após a modelagem da resposta às frequências espaciais com função de diferença de gaussianas, extraiu-se a frequência espacial ótima e banda de frequências com amplitudes acima de ¾ da amplitude máxima da função para servirem como indicadores da seletividade espacial da função. Também foi estimada a acuidade visual cromática pelo ajuste de uma função linear aos dados de amplitude a partir da frequência espacial do pico de amplitude até a mais alta frequência espacial testada. Em tricromatas, foi encontrada respostas cromáticas no K2.1 e no K2.2 que apresentaram seletividade espacial diferentes. Os componentes negativos do K2.1 e do K2.2 apresentaram sintonia passa-banda e o componente positivo do K2.1 apresentou sintonia passa-baixa. A acuidade visual estimada de todos os componentes estudados foi próxima àquelas encontradas por Mullen (1985) e Kelly (1983). Diferentes componentes celulares podem estar contribuindo para a geração do VECP pseudoaleatório. Este novo método se candidata a ser uma importante ferramenta para a avaliação não invasiva da visão de cores em humanos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A interferência eletromagnética causada pela linha de energia elétrica afeta negativamente os sinais de instrumentos eletrônicos, especialmente aqueles com baixos níveis de amplitude. Este tipo de interferência é conhecida como interferência de modo comum. Existem muitos métodos e arquiteturas utilizadas para minimizar a influência deste fenômeno de interferência em instrumentos eletrônicos, o mais comum dos quais é a utilização de filtros rejeita banda. Este trabalho apresenta: a análise, desenvolvimento, protótipo e teste de uma nova arquitetura de filtro com característica reconfigurável para instrumentos biomédicos e medição de dados de fluxo em fluido de alta complexidade, com objetivo de reduzir a interferência de modo comum e preservar as componentes do sinal útil na mesma faixa de frequência do ruído, utilizando a técnica de equilíbrio dinâmico de impedância. Além disso, este trabalho pode ser usado em qualquer sistema de medição que também sofra interferência na frequência da linha de alimentação (50/60 Hz, no Brasil e na França, 60 Hz nos Estados Unidos da América). Os blocos de circuitos foram modelados matematicamente e a função de transferência global do circuito fechado foi gerada. Em seguida, o projeto foi descrito e simulado na língua VHDL_AMS e também em um software de simulação eletrônica, usando blocos de componentes discretos, com e sem realimentação. Após análise teórica dos resultados da simulação, um circuito protótipo foi construído e testado usando como entrada um sinal obtido a partir de eletrodos de ECG e Eletrodos Eletroresistivos. Os resultados experimentais do circuito condizem com os da simulação: uma redução de ruído de 98,7% foi obtida em simulações utilizando um sinal sinusoidal, e uma redução de 92% foi realizada utilizando eletrodos de ECG em testes experimentais. Os mesmos testes em eletrodos Eletroresistivos, obtendo o maior valor de 80,3% de redução (durante análise de 3 casos). Em ambos os casos, o sinal útil foi preservado. O método e a sua arquitetura pode ser aplicado para atenuar as interferências que ocorrem na mesma banda de frequência das componentes do sinal útil, preservando ao mesmo tempo estes sinais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an approach to load characterization and revenue metering, which accounts for the influence of supply deterioration and line impedance. It makes use of the Conservative Power Theory and aims at characterizing the load from the measurements done at the point of common coupling. Despite the inherent limitations of a single-point measurement, the proposed methodology enables evaluation of power terms, which clarify the effects of reactivity, asymmetry and distortion, and attempts to depurate the power consumption accounted to the load from those terms deriving from supply nonidealities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)