967 resultados para Sensor array processing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is devoted to study the pre-treatment of lignocellulosic biomass, especially wheat straw, by the application of the acidic ionic liquid (IL) such as 1-butyl-3-methylimidazolium hydrogen sulphate. The ability of this IL to hydrolysis and conversion of biomass was scrutinised. The pre-treatment with hydrogen sulphate-based IL allowed to obtain a liquor rich in hemicellulosic sugars, furans and organic acids, and a solid fraction mainly constituted by cellulose and lignin. Quantitative and qualitative analyses of the produced liquors were made by capillary electrophoresis and high-performance liquid chromatography. Pre-treatment conditions were set to produce xylose or furfural. Specific range of temperatures from 70 to 175 °C and residence times from 20.0 to 163.3 min were studied by fixing parameters such as biomass/IL ratio (10 % (w/w)) and water content (1.25 % (w/w)) in the pre-treatment process. Statistical modelling was applied to maximise the xylose and furfural concentrations. For the purpose of reaction condition comparison the severity factor for studied ionic liquid was proposed and applied in this work. Optimum conditions for xylose production were identified to be at 125 °C and 82.1 min, at which 16.7 % (w/w) xylose yield was attained. Furfural was preferably formed at higher pre-treatment temperatures and longer reaction time (161 °C and 104.5 min) reaching 30.7 % (w/w) maximum yield. The influence of water content on the optimum xylose formation was also studied. Pre-treatments with 5 and 10 % (w/w) water content were performed and an increase of 100 % and 140 % of xylose yield was observed, respectively, while the conversion into furfural maintained unchanged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro/nano wrinkled patterns on cross-linked urethane/urea polymeric flexible free standing films with two soft segments, polypropylene oxide and polybutadiene, can be induced by UV-irradiation. The ability to write/erase these 3D structures, in a controlled manner, is the main focus of this work. The imprinting of the wrinkled structures was accomplished by swelling in an appropriate solvent followed by drying the membranes after the cross-linking process and UV irradiation. The surface tailoring of the elastomeric membranes was imaged by optical microscopy, scanning electronic microscopy and by atomic force microscopy. To erase the wrinkled structures the elastomers were swollen. The swelling as well as the sol/gel fraction and the UV radiation were tuned in order to control the wrinkles characteristics. It was found that the wrinkles wavelength, in the order of microns (1±0,25μm), was stamped by the UV radiation intensity and exposure time while the wrinkles' amplitude, in the order of nanometers (150-450 nm), was highly dependent on the swelling and sol/gel fraction. A prototype for volatile organic compounds detection was developed taking advantage of the unique 3D micro/nano wrinkles features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bactérias eletroquimicamente ativas possuem a capacidade de transferir eletrões extracelularmente, durante a respiração celular. Esta característica tem sido atualmente explorada para aplicação na produção de eletricidade, tratamento de águas residuais, biorremediação e em diversas áreas da biotecnologia, onde a transferência eletrónica ocorre na presença de aceitadores insolúveis (tais como, óxidos metálicos e ânodos metálicos). Contudo, o número de espécies identificadas, isoladas e caracterizadas até à data é bastante reduzido. Os métodos atualmente disponíveis para deteção de bactérias eletroquimicamente ativas são morosos, dispendiosos e complexos de operar, tornando-se necessário o desenvolvimento de outros métodos mais rápidos, simples e menos dispendiosos que auxiliem na otimização das aplicações mencionadas. O objetivo principal deste trabalho foi o desenvolvimento de um sensor colorimétrico de papel utilizando um material eletrocrómico, trióxido de tungsténio, como camada ativa para a deteção destas bactérias. Para isso, foram definidos no papel poços delimitados por barreiras hidrofóbicas, através da impressão e difusão de uma camada de cera. As várias amostras de nanopartículas de WO3, sintetizadas por um método hidrotermal assistido por micro-ondas, foram depositadas nos poços por drop casting. As nanopartículas com estrutura cristalográfica hexagonal, impregnadas no sensor de papel, foram capazes de detetar com sucesso uma bactéria eletroquimicamente ativa, Geobacter sulfurreducens, desde uma fase de crescimento bastante inicial (Abs600 nm = 0,1, correspondente a 0,07 g/L com um rácio RGB de 1,10 ± 0,040) até à fase exponencial-tardia (Abs600 nm = 0,5, correspondente a 0,33 g/L com um rácio RGB de 1,33 ± 0,005), com P <0,0001. O sensor de papel e respetivo método de deteção colorimétrico desenvolvido neste trabalho, revelou ser sensível e específico à deteção destas bactérias, de uma forma rápida, simples e pouco dispendiosa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of this Thesis was the study of the sensor domains of two heme-containing methyl-accepting chemotaxis proteins (MCP) from Geobacter sulfurreducens: GSU0582 and GSU0935. These domains contain one c-type heme, form swapped dimers with a PAS-like fold and are the first examples of a new class of heme sensors. NMR spectroscopy was used to assign the heme and polypeptide signals in both sensors, as a first step to probe conformational changes in the vicinity of the hemes. However, the presence of two conformations in solution impaired the confident assignment of the polypeptide signals. To understand how conformational changes and swapped dimerization mechanism can effectively modulate the function of the two sensor domains and their signal transduction process, the sensor domains folding and stability were studied by circular dichroism and UV-visible spectroscopy. The results showed differences in the thermodynamic stability of the sensors, with GSU0582 displaying higher structural stability. These studies also demonstrated that the heme moiety undergoes conformational changes matching those occurring at the global protein structure and that the content of intrinsically disordered segments within these proteins (25% for GSU0935; 13% for GSU0582) correlates with the stability differences observed. The thermodynamic and kinetic properties of the sensor domains were determined at different pH and ionic strength by visible spectroscopy and stopped-flow techniques. Despite the remarkably similar spectroscopic and structural features of the two sensor domains, the results showed that their properties are quite distinct. Sensor domain GSU0935 displayed more negative reduction potentials and smaller reduction rate constants, which were more affected by pH and ionic strength. The available structures were used to rationalize these differences. Overall, the results described in this Thesis indicate that the two G. sulfurreducens MCP sensor domains are designed to function in different working potential ranges, allowing this bacterium to trigger an adequate cellular response in distinct anoxic subsurface environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the invention of photography humans have been using images to capture, store and analyse the act that they are interested in. With the developments in this field, assisted by better computers, it is possible to use image processing technology as an accurate method of analysis and measurement. Image processing's principal qualities are flexibility, adaptability and the ability to easily and quickly process a large amount of information. Successful examples of applications can be seen in several areas of human life, such as biomedical, industry, surveillance, military and mapping. This is so true that there are several Nobel prizes related to imaging. The accurate measurement of deformations, displacements, strain fields and surface defects are challenging in many material tests in Civil Engineering because traditionally these measurements require complex and expensive equipment, plus time consuming calibration. Image processing can be an inexpensive and effective tool for load displacement measurements. Using an adequate image acquisition system and taking advantage of the computation power of modern computers it is possible to accurately measure very small displacements with high precision. On the market there are already several commercial software packages. However they are commercialized at high cost. In this work block-matching algorithms will be used in order to compare the results from image processing with the data obtained with physical transducers during laboratory load tests. In order to test the proposed solutions several load tests were carried out in partnership with researchers from the Civil Engineering Department at Universidade Nova de Lisboa (UNL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis a piezoelectric energy harvesting system, responsible for regulating the power output of a piezoelectric transducer subjected to ambient vibration, is designed to power an RF receiver with a 6 mW power consump-tion. The electrical characterisation of the chosen piezoelectric transducer is the starting point of the design, which subsequently presents a full-bridge cross-coupled rectifier that rectifies the AC output of the transducer and a low-dropout regulator responsible for delivering a constant voltage system output of 0.6 V, with low voltage ripple, which represents the receiver’s required sup-ply voltage. The circuit is designed using CMOS 130 nm UMC technology, and the system presents an inductorless architecture, with reduced area and cost. The electrical simulations run for the complete circuit lead to the conclusion that the proposed piezoelectric energy harvesting system is a plausible solution to power the RF receiver, provided that the chosen transducer is subjected to moderate levels of vibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mobile IT era is here, it is still growing and expanding at a steady rate and, most of all, it is entertaining. Mobile devices are used for entertainment, whether social through the so-called social networks, or private through web browsing, video watching or gaming. Youngsters make heavy use of these devices, and even small children show impressive adaptability and skill. However not much attention is directed towards education, especially in the case of young children. Too much time is usually spent in games which only purpose is to keep children entertained, time that could be put to better use such as developing elementary geometric notions. Taking advantage of this pocket computer scenario, it is proposed an application geared towards small children in the 6 – 9 age group that allows them to consolidate knowledge regarding geometric shapes, forming a stepping stone that leads to some fundamental mathematical knowledge to be exercised later on. To achieve this goal, the application will detect simple geometric shapes like squares, circles and triangles using the device’s camera. The novelty of this application will be a core real-time detection system designed and developed from the ground up for mobile devices, taking into account their characteristic limitations such as reduced processing power, memory and battery. User feedback was be gathered, aggregated and studied to assess the educational factor of the application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A apresentação do presente relatório visa a obtenção do Grau de Mestre em Ensino de Físico Química de acordo com o estabelecido no regulamento para Licenciados “Pré-Bolonha”, que abrange as licenciaturas de cinco anos com, pelo menos, cinco anos de experiência profissional. O percurso académico e profissional permitiram a aquisição de conhecimentos, tanto na Física como na Química, e um conjunto de aptidões como a capacidade organizacional, a capacidade de trabalhar em equipa e competências sociais. A constante vontade em atualizar conhecimentos e adquirir novas competências têm sido um incentivo para continuar a frequentar cursos de formação, seminários, workshops conferências dedicadas a esta área, assim como às do ensino. O presente trabalho é composto por duas partes. Na primeira parte, encontra-se a discrição da minha atividade profissional. Na segunda parte, encontra-se a apresentação detalhada do estudo da atividade laboratorial da bola saltitante por dois processos diferentes: utilizando um sensor de movimento e usando a análise de vídeo através do software Tracker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viral vectors are playing an increasingly important role in the vaccine and gene therapy elds. The broad spectrum of potential applications, together with expanding medical markets, drives the e orts to improve the production processes for viral vaccines and viral vectors. Developing countries, in particular, are becoming the main vaccine market. It is thus critical to decrease the cost per dose, which is only achievable by improving the production process. In particular advances in the upstream processing have substantially increased bioreactor yields, shifting the bioprocess bottlenecks towards the downstream processing. The work presented in this thesis aimed to develop new processes for adenoviruses puri cation. The use of state-of-the-art technology combined with innovative continuous processes contributed to build robust and cost-e ective strategies for puri cation of complex biopharmaceuticals.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A proteção dos recursos hídricos tem uma enorme importância ecológica, sendo a água um recurso indispensável à Vida e fundamental para o bem-estar de uma sociedade. Para isso, muitos dos poluentes que afetam a qualidade deste recurso natural são detetados e eliminados nas estações de tratamento de águas residuais. Porém, o impacto dos Produtos Farmacêuticos e de Cuidado Pessoal (PPCPs), usados à escala global, carece ainda da atenção necessária, dado que os meios técnicos atualmente disponíveis para detetar estes produtos são dispendiosos ou insuficientes. Dentro daquela classe de produtos, destaca-se o Ibuprofeno, uma vez que este composto, sendo lipossolúvel, tem a capacidade para se acumular nas gorduras dos seres vivos e, por conseguinte, persistir no meio-ambiente com efeitos nocivos. Para além desse facto, por diferentes vias de reação, o Ibuprofeno tem potencial para gerar produtos de carácter semelhante. No entanto, pouco esforços têm sido feitos no sentido de o detetar. Assim, pretendeu-se com este projeto desenvolver metodologias com vista à deteção de muito baixas concentrações (entre o nano e o picoMolar) daquele composto em meio aquoso. Foi utilizada a tecnologia de Língua Eletrónica por Espectroscopia de Impedância e, para tentar melhorar a sensibilidade do sensor à molécula-alvo, foram utilizados filmes finos à base de nanotubos de carbono e de diferentes polieletrólitos, preparados pela técnica de Camada-sobre-Camada (LbL, do inglês Layer-by-Layer). A caracterização destes filmes foi feita pela técnica Espectrofotometria na faixa dos Ultravioleta e Visível. Para além da análise de diferentes concentrações de Ibuprofeno, foram ainda analisadas soluções de Cloreto de Sódio, com o intuito de perceber se o sensor é versátil na deteção de outro tipo de compostos, sendo, então, o sal um composto barato e relevante neste âmbito, uma vez que a água na Natureza apresenta sempre alguma salinidade. O trabalho compreendeu ainda o desenvolvimento de um programa informático para automatizar o processo de aquisição dos dados espectrais de impedância, recolhidos pelo analisador HAMEG Programmable LCR Bridge HM8118, o que foi feito com sucesso. Posteriormente, os dados foram tratados pelo procedimento estatístico de Análise de Componentes Principais, que permitiu discriminar espacialmente e sequencialmente as diferentes concentrações dos compostos analisados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are constantly immersed in stimuli. Upon reaching our senses, stimuli are processed within various brain systems along various pathways into the brain, and eventually turned into a percept. However, there are percepts that do not result from responses to external source stimuli. A particular case of this situation is the auditory percept known as tinnitus. Tinnitus can be seen as a task-irrelevant auditory percept, commonly reported to interfere with normal daily tasks. This is known from reports made by tinnitus sufferers that refer to their phantom percept as distracting, and that it diverts their focus from the task-relevant stimuli.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study in the field of Consumer Behavior, brand name memory of consumers with regard to verbal and visual incongruent and congruent information such as memory structure of brands was tested. Hence, four experimental groups with different constellations of verbal and visual congruity and incongruity were created to compare their brand name memory performance. The experiment was conducted in several classes with 128 students, each group with 32 participants. It was found that brands, which are presented in a congruent or moderately incongruent relation to their brand schema, result in a better brand recall than their incongruent counterparts. A difference between visual congruity and moderately incongruity could not be confirmed. In contrast to visual incongruent information, verbal incongruent information does not result in a worse brand recall performance.