963 resultados para Sensitivity and specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Leptospirosis is often mistaken for other acute febrile illnesses because of its nonspecific presentation. Bacteriologic, serologic, and molecular methods have several limitations for early diagnosis: technical complexity, low availability, low sensitivity in early disease, or high cost. This study aimed to validate a case definition, based on simple clinical and laboratory tests, that is intended for bedside diagnosis of leptospirosis among hospitalized patients. METHODS: Adult patients, admitted to two reference hospitals in Recife, Brazil, with a febrile illness of less than 21 days and with a clinical suspicion of leptospirosis, were included to test a case definition comprising ten clinical and laboratory criteria. Leptospirosis was confirmed or excluded by a composite reference standard (microscopic agglutination test, ELISA, and blood culture). Test properties were determined for each cutoff number of the criteria from the case definition. RESULTS: Ninety seven patients were included; 75 had confirmed leptospirosis and 22 did not. Mean number of criteria from the case definition that were fulfilled was 7.8±1.2 for confirmed leptospirosis and 5.9±1.5 for non-leptospirosis patients (p<0.0001). Best sensitivity (85.3%) and specificity (68.2%) combination was found with a cutoff of 7 or more criteria, reaching positive and negative predictive values of 90.1% and 57.7%, respectively; accuracy was 81.4%. CONCLUSIONS: The case definition, for a cutoff of at least 7 criteria, reached average sensitivity and specificity, but with a high positive predictive value. Its simplicity and low cost make it useful for rapid bedside leptospirosis diagnosis in Brazilian hospitalized patients with acute severe febrile disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Introdução: A obstrução da via aérea central (OVAC) refere-se a um processo patológico que conduz a limitação do fluxo de ar ao nível do espaço glótico e subglótico, traqueia e brônquios principais. O seu correcto diagnóstico e tratamento constituem um território de interesse e preocupação para os profissionais de saúde, e requerem um profundo conhecimento da sua etiologia, fisiologia, diagnóstico e opções terapêuticas dado o potencial em originar significativa morbilidade e mortalidade. A avaliação da OVAC abrange múltiplas vertentes, entre as quais se salienta o componente clínico (sinais e sintomas), a repercussão fisiopatológica (função respiratória) e o estudo imagiológico (TC do tórax e broncoscopia). A compilação destes dados associada à etiologia, constituem factores importantes para estabelecer o prognóstico, determinar a necessidade de tratamento ou delinear uma futura intervenção terapêutica. A broncoscopia é o Gold Standard de avaliação desta condição, mas desde há cerca de 40 anos a curva de débito-volume constitui uma ferramenta não invasiva de detecção de OVAC. Apesar deste método ser utilizado até os nossos dias, poucos têm sido os estudos com o objectivo de verificar a sensibilidade e especificidade da curva de débito-volume na detecção de OVAC, bem como averiguar a relação entre as alterações morfológicas e quantitativas da mesma com a localização, o tipo e o grau da obstrução. Material e Métodos: Entre 1 de Novembro de 2009 e 30 de Abril de 2010, os doentes com indicação para a realização de broncoscopia diagnóstica ou terapêutica na Unidade de Técnicas Invasivas Pneumológicas (UTIP) do Centro Hospitalar Lisboa Norte – Hospital Pulido Valente (CHLN – HPV) foram seleccionados de forma consecutiva de acordo com os critérios de inclusão e exclusão. As avaliações (broncoscopia, curva de débito-volume e avaliação da dispneia) realizaram-se com um intervalo de tempo máximo de sete dias. A broncoscopia flexível foi realizada segundo as normas da British Thoracic Society e as curvas de débito-volume segundo as normas da ATS/ERS TaskForce 2005. Para a avaliação da dispneia recorreu-se à escala de dispneia MRC (Medical Research Council). Um painel de peritos realizou a avaliação da morfologia da curva de débito-volume (sugestiva ou não de OVAC) e um elemento independente a verificação dos critérios quantitativos e morfológicos (variáveis intra e extratorácica e fixa) da curva. O estudo foi aprovado pela Comissão de Ética para a Saúde do CHLN e todos os doentes assinaram um consentimento informado de participação. Resultados: Estudaram-se 82 doentes, 36 (44%) dos quais com OVAC. A predominância foi do género masculino, em relação ao feminino. A sensibilidade e especificidade dos critérios quantitativos da curva de débito-volume na detecção de OVAC foi de 91.3% e 88.9% respectivamente. Quando se utilizaram os critérios morfológicos da curva de débito-volume os valores foram de 93.5% e 30.6%. A agregação dos critérios morfológicos e quantitativos permitiu alcançar uma sensibilidade de 95.7% e especificidade de 86.1%. Nesta amostra, o critério quantitativo com maior ocorrência foi o FEF50/FIF50≥1 (83% dos doentes com OVAC). Este mostrou relacionar-se com todas as localizações de obstrução excepto o terço médio da traqueia. Mostrou, ainda, ter uma relação forte e positiva com o grau e tipo de obstrução (intra e extraluminal). O segundo foi o FEV1/PEF≥8, presente em 36% dos casos de OVAC. Relacionou-se com as obstruções no terço inferior da traqueia e brônquio principal direito (BPD). Também apresentou relação forte e positiva com o grau de obstrução e com os tipos de obstrução anteriormente descritos. Quanto à sintomatologia foi possível associar o grau de obstrução com o de dispneia e a presença de estridor com o grau e localização da obstrução na traqueia. Conclusões: Os resultados deste estudo demonstram que os critérios quantitativos da curva de débito-volume têm elevada sensibilidade e especificidade na detecção de OVAC. O critério FEV50/FIF50≥1 tem um bom poder discriminativo na detecção dessa condição, tendo sido relacionado com a localização, o grau e o tipo de obstrução. O critério FEV1/PEF≥8, embora com menor poder discriminativo, também se relaciona com o grau, a localização e o tipo de obstrução. A morfologia da curva tem uma boa sensibilidade mas baixa especificidade na detecção de OVAC, mas a agregação entre os critérios morfológicos e quantitativos aumenta a sensibilidade e especificidade. A dispneia e o estridor foram relacionados com o grau de obstrução e o último com a localização ao nível da traqueia.-------------ABSTRACT: Introduction: Central airway obstruction (CAO) refers to a pathological process that leads to restriction of airflow at the level of the glottis and subglottis, trachea and main bronchi. It’s proper diagnosis and treatment is an area of interest and concern to health professionals, and requires a deep knowledge of its etiology, physiology, diagnosis and treatment options, concerning the potential to cause significant morbidity and mortality. The evaluation of CAO covers multiple aspects: the clinical component (signs and symptoms), the pathophysiological effect (lung function) and the imaging study (bronchoscopy and chest CT). The compilation of this data associated with the etiology, are important for establishing prognosis, determine the need for treatment or outline a future therapeutic intervention. Bronchoscopy is the gold standard for evaluating this condition, but for the last 40 years the flow-volume loop has been used as a noninvasive tool for detecting CAO. Although this method is still in use, only few studies were made in order to verify its sensitivity and specificity in detecting CAO, and investigate the relation between morphological and quantitative changes of the curve to location, type and degree of obstruction. Methods: Between 1st November 2009 and 30th April 2010, patients with indication to perform diagnostic or therapeutic bronchoscopy in Interventional Pulmonology Unit - Hospital Pulido Valente (CHLN - HPV), were selected consecutively according to the inclusion and exclusion criteria. All assessments (bronchoscopy, flow-volume loop and dyspnea) were carried out within a period of seven days. The flexible bronchoscopy was performed according to the standards of the British Thoracic Society and the flow-volume loops in accordance with the standards of the ATS / ERS Taskforce 2005. For the evaluation of dyspnea was used to MRC dyspnea scale (Medical Research Council). A panel of experts evaluated the morphology of flow-volume loop (suggestive or non-suggestive of CAO) and an independent element established the quantitative criteria and morphological (intra and extrathoracic variables and fixed) of the curve. This study was approved by the Ethics Committee for Health CHLN and all the patients signed an informed consent to participate. Results: We’ve studied 82 patients, 36 (44%) of those with CAO. The majority of the patients were males, compared to females. The sensitivity and specificity of the quantitative criteria of the flow-volume curve in detecting CAO was 91.3% and 88.9% respectively. When we used the morphological criteria of flow-volume loop these values were 93.5% and 30.6%. The combination of quantitative and morphological criteria produced values of 95.7% sensitivity and 86.1% specificity. FEF50/FIF50≥1 was the most representative quantitative criterion (83% of patients with CAO) and it was correlated with all sites of obstruction except in the middle third of the trachea. It has shown a strong and positive association with the degree and type of obstruction (intra and extraluminal). The second was the FEV1/PEF ≥ 8, present in 36% of cases of CAO. It could be correlated with the obstruction in the lower third of the trachea and right main bronchus. It also showed a strong positive relation with the degree and types of obstruction described above. Regarding symptoms, we found a link between the degree of obstruction and dyspnea. The presence of stridor was correlated with the location and the degree of obstruction in the trachea. Conclusion: The results of this study demonstrate that the quantitative criteria of the flow-volume loop have a high sensitivity and specificity in detecting CAO. The criterion FEV50/FIF50 ≥ 1 has a good discriminative power to detect this condition and was related to the location, degree and type of obstruction. The criterion FEV1/PEF ≥ 8, although with a weaker discriminative power, also relates to the degree, location and type of obstruction. The morphology of the curve has a good sensitivity but low specificity in detecting CAO although the combination between the morphological and quantitative criteria increases sensitivity and specificity. Dyspnea and stridor were related to the degree of obstruction and the last one with its location in the trachea.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Dengue is prevalent in many tropical and sub-tropical regions. The clinical diagnosis of dengue is still complex, and not much data are available. This work aimed at assessing the diagnostic accuracy of the tourniquet test in patients with suspected dengue infection and its positivity in different classifications of this disease as reported to the Information System for Notifiable Disease in Belo Horizonte, State of Minas Gerais, Brazil between 2001 and 2006. Methods Cross-section analysis of the diagnostic accuracy of the tourniquet test for dengue, using IgM-anti-DENV ELISA as a gold standard. Results We selected 9,836 suspected cases, of which 41.1% were confirmed to be dengue. Classic dengue was present in 95.8%, dengue with complications in 2.5% and dengue hemorrhagic fever in 1.7%. The tourniquet test was positive in 16.9% of classic dengue cases, 61.7% of dengue cases with complications and 82.9% of cases of dengue hemorrhagic fever. The sensitivity and specificity of the tourniquet test were 19.1% and 86.4%, respectively. Conclusions A positive tourniquet test can be a valuable tool to support diagnosis of dengue where laboratory tests are not available. However, the absence of a positive test should not be read as the absence of infection. In addition, the tourniquet test was demonstrated to be an indicator of dengue severity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract:INTRODUCTION:The Montenegro skin test (MST) has good clinical applicability and low cost for the diagnosis of American tegumentary leishmaniasis (ATL). However, no studies have validated the reference value (5mm) typically used to discriminate positive and negative results. We investigated MST results and evaluated its performance using different cut-off points.METHODS:The results of laboratory tests for 4,256 patients with suspected ATL were analyzed, and 1,182 individuals were found to fulfill the established criteria. Two groups were formed. The positive cutaneous leishmaniasis (PCL) group included patients with skin lesions and positive direct search for parasites (DS) results. The negative cutaneous leishmaniasis (NCL) group included patients with skin lesions with evolution up to 2 months, negative DS results, and negative indirect immunofluorescence assay results who were residents of urban areas that were reported to be probable sites of infection at domiciles and peridomiciles.RESULTS:The PCL and NCL groups included 769 and 413 individuals, respectively. The mean ± standard deviation MST in the PCL group was 12.62 ± 5.91mm [95% confidence interval (CI): 12.20-13.04], and that in the NCL group was 1.43 ± 2.17mm (95% CI: 1.23-1.63). Receiver-operating characteristic curve analysis indicated 97.4% sensitivity and 93.9% specificity for a cut-off of 5mm and 95.8% sensitivity and 97.1% specificity for a cut-off of 6mm.CONCLUSIONS:Either 5mm or 6mm could be used as the cut-off value for diagnosing ATL, as both values had high sensitivity and specificity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: The treatment of individuals with active tuberculosis (TB) and the identification and treatment of latent tuberculosis infection (LTBI) contacts are the two most important strategies for the control of TB. The objective of this study was compare the performance of tuberculin skin testing (TST) with QuantiFERON-TB Gold In TUBE(r) in the diagnosis of LTBI in contacts of patients with active TB. METHODS: Cross-sectional analytical study with 60 contacts of patients with active pulmonary TB. A blood sample of each contact was taken for interferon-gamma release assay (IGRA) and subsequently performed the TST. A receiver operating characteristic curve was generated to assess the cutoff points and the sensitivity, predictive values, and accuracy were calculated. The agreement between IGRA and TST results was evaluated by Kappa coefficient. RESULTS: Here, 67.9% sensitivity, 84.4% specificity, 79.1% PPV, 75% NPV, and 76.7% accuracy were observed for the 5mm cutoff point. The prevalence of LTBI determined by TST and IGRA was 40% and 46.7%, respectively. CONCLUSIONS: Both QuantiFERON-TB Gold In TUBE(r) and TST showed good performance in LTBI diagnosis. The creation of specific diagnostic methods is necessary for the diagnosis of LTBI with higher sensitivity and specificity, preferably with low cost and not require a return visit for reading because with early treatment of latent forms can prevent active TB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: In Brazil, culling of seropositive dogs is one of the recommended strategies to control visceral leishmaniasis. Since infectiousness is correlated with clinical signs, control measures targeting symptomatic dogs could be more effective. METHODS: A cross-sectional study was carried out among 1,410 dogs, predictive models were developed based on clinical signs and an indirect immunofluorescence antibody test. RESULTS: The validated predictive model showed sensitivity and specificity of 86.5% and 70.0%, respectively. CONCLUSIONS: Predictive models could be used as tools to aid control programs in focusing on a smaller fraction of dogs contributing more to infection dissemination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report the experience of a radiology department in the use of computed tomography - guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. METHODS: This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). RESULTS: In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. CONCLUSION: The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to differentiate benign ovarian tumors from malignant ones before surgery using color and pulsed Doppler sonography, and to compare results obtained before and after use of contrast medium, thereby verifying whether contrast results in an improvement in the diagnostic sensitivity. METHODS: Sixty two women (mean age 49.9 years) with ovarian tumors were studied, 45 with benign and 17 with malignant tumors. All women underwent a transvaginal color Doppler ultrasonographic exam. A study of the arterial vascular flow was made in all tumor areas, as well as an impedance evaluation of arterial vascular flow using the resistance index. RESULT: Localization of the vessels in the tumor revealed a greater proportion of malignant tumors with detectable internal vascular flows (64%) than benign tumors with such flows (22%). There was a considerable overlap of these findings. The use of contrast identified a greater number of vessels with confirmation in the totality of tumors, but did not improve the Doppler capacity in tumoral differentiation. Malignant tumors presented lower values of resistance index than the benign ones, whether or not contrast was used. The cutoff value for resistance index that better maximized the Doppler sensitivity and specificity was 0.55. Through this value, an increase of the sensitivity after contrast use was obtained, varying from 47% to 82%, while specificity remained statistically unchanged. CONCLUSION: Although the injection of a microbubble agent improved the sensitivity of the method detecting vascularization of tumors, a positive finding for vascularization by this method was not clinically useful in the differentiation of benign and malignant ovarian tumors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Worldwide, around 9% of the children are born with less than 37 weeks of labour, causing risk to the premature child, whom it is not prepared to develop a number of basic functions that begin soon after the birth. In order to ensure that those risk pregnancies are being properly monitored by the obstetricians in time to avoid those problems, Data Mining (DM) models were induced in this study to predict preterm births in a real environment using data from 3376 patients (women) admitted in the maternal and perinatal care unit of Centro Hospitalar of Oporto. A sensitive metric to predict preterm deliveries was developed, assisting physicians in the decision-making process regarding the patients’ observation. It was possible to obtain promising results, achieving sensitivity and specificity values of 96% and 98%, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Maternity Care, a quick decision has to be made about the most suitable delivery type for the current patient. Guidelines are followed by physicians to support that decision; however, those practice recommendations are limited and underused. In the last years, caesarean delivery has been pursued in over 28% of pregnancies, and other operative techniques regarding specific problems have also been excessively employed. This study identifies obstetric and pregnancy factors that can be used to predict the most appropriate delivery technique, through the induction of data mining models using real data gathered in the perinatal and maternal care unit of Centro Hospitalar of Oporto (CHP). Predicting the type of birth envisions high-quality services, increased safety and effectiveness of specific practices to help guide maternity care decisions and facilitate optimal outcomes in mother and child. In this work was possible to acquire good results, achieving sensitivity and specificity values of 90.11% and 80.05%, respectively, providing the CHP with a model capable of correctly identify caesarean sections and vaginal deliveries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD) in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations) and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada al Laboratori de Inmunopatología del SIDA del Dr Alcamí a l’Instituto de Salud Carlos III-Centro Nacional de Microbiologia, entre finals de desembre de 2006 i març de 2007. L’objectiu ha estat millorar la caracterització de l’envolta del VIH-1 mitjançant l’obtenció de virus recombinants, ja que això permet estudiar l’envolta viral tant genètica com fenotípicament. En aquest cas, s’ha estudiat l'envolta viral dels pacients sotmesos a vacunació terapèutica amb cèl•lules dendrítiques polsades amb virus autòlegs. Durant aquesta estada es realitza un aprenentatge profund de les tècniques adequades per a l'amplificació i clonatge del gen complet de l'envolta del VIH-1 (env), així com de l’obtenció de virus recombinants amb l’envolta del pacient i els corresponents assaigs de tropisme viral i neutralització sèrica. Aquesta metodologia empra el virus quimèric pNL4.3 delta_env Renilla, construït a partir del virus de referència NL4.3 i que té dues característiques importants: la primera és que conté un gen marcador Renilla, que a l’interior de les cèl•lules infectades té activitat luciferasa. La utilització del virus pNL4.3 delta_env Renilla en assaigs de neutralització presenta diversos avantatges front altres assaigs més convencionals, tant a nivell de sensibilitat i especificitat com d’estalvi de temps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The unresolved issue of false-positive D-dimer results in the diagnostic workup of pulmonary embolism Pulmonary embolism (PE) remains a difficult diagnosis as it lacks specific symptoms and clinical signs. After the determination of the pretest PE probability by a validated clinical score, D-dimers (DD) is the initial blood test in the majority of patients whose probability is low or intermediate. The low specificity of DD results in a high number of false-positives that then require thoracic angio-CT. A new clinical decision rule, called the Pulmonary Embolism Rule-out criteria (PERC), identifies patients at such low risk that PE can be safely ruled-out without a DD test. Its safety has been confirmed in US emergency departments, but retrospective European studies showed that it would lead to 5-7% of undiagnosed PE. Alternative strategies are needed to reduce the proportion of false-positive DD results.