986 resultados para Safety Device Attitudes.
Resumo:
Hazardous chemical products have to comply with, amongst others, the provisions of a correct classification of danger, labelling and compilation of the safety data sheets. The aim is to protect people's health and the environment from exposure to hazardous chemicals- especially the health and safety of direct users, professionals or not, and the general public, via environmental exposure. This publication is intended to contribute to the knowledge of the objectives and basic aspects of these legal provisions, and thereby increase their degree of compliance in Andalusia and other european regions. This Guide is directed toward those people who, in the development of their professional activities, are in one way or another in contact with dangerous chemical products.
Resumo:
Fecal incontinence (FI) is the involuntary loss of rectal contents through the anal canal. Reports of its prevalence vary from 1-21%. Studies, have demonstrated a positive effect on FI symptoms with injectable bulking agents. This study evaluated the safety and efficacy of NASHA/Dx gel in the treatment of FI. One hundred fifteen eligible patients suffering from FI received 4 injections of 1 mL NASHA/Dx gel. Primary efficacy was based on data from 86 patients that completed the study. This study demonstrated a ≥50% reduction from baseline in the number of FI episodes in 57.1% of patients at 6 months, and 64.0% at 12 months. Significant improvements (P < .001) were also noted in total number of both solid and loose FI episodes, FI free days, CCFIS, and FIQL scores in all 4 domains. The majority of the treatment related AEs (94.9%) were mild or moderate intensity, and (98.7%) of AEs resolved spontaneously, or following treatment, without sequelae. Results of this study indicate NASHA/Dx gel was efficacious in the treatment of FI. Treatment effect was significant both in reduction of number of FI episodes and disease specific quality of life at 6 months and lasted up to 12 months after treatment.
Resumo:
Mosquito-borne diseases such as dengue fever, chikungunya or malaria affect millions of people each year and control solutions are urgently needed. An international research program is currently being developed that relies on the introduction of the bacterial endosymbiont Wolbachia pipientis into Aedes aegypti to control dengue transmission. In order to prepare for open-field testing releases of Wolbachia-infected mosquitoes, an intensive social research and community engagement program was undertaken in Cairns, Northern Australia. The most common concern expressed by the diverse range of community members and stakeholders surveyed was the necessity of assuring the safety of the proposed approach for humans, animals and the environment. To address these concerns a series of safety experiments were undertaken. We report in this paper on the experimental data obtained, discuss the limitations of experimental risk assessment and focus on the necessity of including community concerns in scientific research.
Resumo:
Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.
Resumo:
BACKGROUND. Ritonavir-boosted saquinavir (SQVr) is nowadays regarded as an alternative antiretroviral drug probably due to several drawbacks, such as its high pill burden, twice daily dosing and the requirement of 200 mg ritonavir when given at the current standard 1000/100 mg bid dosing. Several once-daily SQVr dosing schemes have been studied with the 200 mg SQV old formulations, trying to overcome some of these disadvantages. SQV 500 mg strength tablets became available at the end of 2005, thus facilitating a once-daily regimen with fewer pills, although there is very limited experience with this formulation yet. METHODS. Prospective, multicentre study in which efficacy, safety and pharmacokinetics of a regimen of once-daily SQVr 1500/100 mg plus 2 NRTIs were evaluated under routine clinical care conditions in either antiretroviral-naïve patients or in those with no previous history of antiretroviral treatments and/or genotypic resistance tests suggesting SQV resistance. Plasma SQV trough levels were measured by HPLV-UV. RESULTS. Five hundred and fourteen caucasian patients were included (47.2% coinfected with hepatitis C and/or B virus; 7.8% with cirrhosis). Efficacy at 52 weeks (plasma RNA-HIV <50 copies/ml) was 67.7% (CI95: 63.6 - 71.7%) by intention-to-treat, and 92.2% (CI95: 89.8 - 94.6%) by on-treatment analysis. The reasons for failure were: dropout or loss to follow-up (18.4%), virological failure (7.8%), adverse events (3.1%), and other reasons (4.6%). The high rate of dropout may be explained by an enrollment and follow-up under routine clinical care condition, and a population with a significant number of drug users. The median SQV Cmin (n = 49) was 295 ng/ml (range, 53-2172). The only variable associated with virological failure in the multivariate analysis was adherence (OR: 3.36; CI95, 1.51-7.46, p = 0.003). CONCLUSIONS. Our results suggests that SQVr (1500/100 mg) once-daily plus 2 NRTIs is an effective regimen, without severe clinical adverse events or hepatotoxicity, scarce lipid changes, and no interactions with methadone. All these factors and its once-daily administration suggest this regimen as an appropriate option in patients with no SQV resistance-associated mutations.
Resumo:
BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
Antibiotics used by general practitioners frequently appear in adverse-event reports of drug-induced hepatotoxicity. Most cases are idiosyncratic (the adverse reaction cannot be predicted from the drug's pharmacological profile or from pre-clinical toxicology tests) and occur via an immunological reaction or in response to the presence of hepatotoxic metabolites. With the exception of trovafloxacin and telithromycin (now severely restricted), hepatotoxicity crude incidence remains globally low but variable. Thus, amoxicillin/clavulanate and co-trimoxazole, as well as flucloxacillin, cause hepatotoxic reactions at rates that make them visible in general practice (cases are often isolated, may have a delayed onset, sometimes appear only after cessation of therapy and can produce an array of hepatic lesions that mirror hepatobiliary disease, making causality often difficult to establish). Conversely, hepatotoxic reactions related to macrolides, tetracyclines and fluoroquinolones (in that order, from high to low) are much rarer, and are identifiable only through large-scale studies or worldwide pharmacovigilance reporting. For antibiotics specifically used for tuberculosis, adverse effects range from asymptomatic increases in liver enzymes to acute hepatitis and fulminant hepatic failure. Yet, it is difficult to single out individual drugs, as treatment always entails associations. Patients at risk are mainly those with previous experience of hepatotoxic reaction to antibiotics, the aged or those with impaired hepatic function in the absence of close monitoring, making it important to carefully balance potential risks with expected benefits in primary care. Pharmacogenetic testing using the new genome-wide association studies approach holds promise for better understanding the mechanism(s) underlying hepatotoxicity.
Resumo:
In this paper we discuss the consensus view on the use of qualifying biomarkers in drug safety, raised within the frame of the XXIV meeting of the Spanish Society of Clinical Pharmacology held in Málaga (Spain) in October, 2011. The widespread use of biomarkers as surrogate endpoints is a goal that scientists have long been pursuing. Thirty years ago, when molecular pharmacogenomics evolved, we anticipated that these genetic biomarkers would soon obviate the routine use of drug therapies in a way that patients should adapt to the therapy rather than the opposite. This expected revolution in routine clinical practice never took place as quickly nor with the intensity as initially expected. The concerted action of operating multicenter networks holds great promise for future studies to identify biomarkers related to drug toxicity and to provide better insight into the underlying pathogenesis. Today some pharmacogenomic advances are already widely accepted, but pharmacogenomics still needs further development to elaborate more precise algorithms and many barriers to implementing individualized medicine exist. We briefly discuss our view about these barriers and we provide suggestions and areas of focus to advance in the field.
Resumo:
OBJECTIVE: Previous literature has suggested that laws and regulations may impact the use of palliative sedation. Our present study compares the attitudes of French-speaking physicians practicing in the Quebec and Swiss environments, where different laws are in place regarding physician-assisted suicide. METHOD: Data were drawn from two prior studies, one by Blondeau and colleagues and another by Beauverd and coworkers, employing the same two-by-two experimental design with length of prognosis and type of suffering as independent variables. Both the effect of these variables and the effect of their interaction on Swiss and Quebec physicians' attitudes toward sedation were compared. The written comments of respondents were submitted to a qualitative content analysis and summarized in a comparative perspective. RESULTS: The analysis of variance showed that only the type of suffering had an effect on physicians' attitudes toward sedation. The results of the Wilcoxon test indicated that the attitudes of physicians from Quebec and Switzerland tended to be different for two vignettes: long-term prognosis with existential suffering (p = 0.0577) and short-term prognosis with physical suffering (p = 0.0914). In both cases, the Swiss physicians were less prone to palliative sedation. SIGNIFICANCE OF RESULTS: The attitudes of physicians from Quebec and Switzerland toward palliative sedation, particularly regarding prognosis and type of suffering, seem similar. However, the results suggest that physicians from Quebec could be slightly more open to palliative sedation, even though most were not in favor of this practice as an answer to end-of-life existential suffering.
Resumo:
BACKGROUND Drugs for inhalation are the cornerstone of therapy in obstructive lung disease. We have observed that up to 75 % of patients do not perform a correct inhalation technique. The inability of patients to correctly use their inhaler device may be a direct consequence of insufficient or poor inhaler technique instruction. The objective of this study is to test the efficacy of two educational interventions to improve the inhalation techniques in patients with Chronic Obstructive Pulmonary Disease (COPD). METHODS This study uses both a multicenter patients´ preference trial and a comprehensive cohort design with 495 COPD-diagnosed patients selected by a non-probabilistic method of sampling from seven Primary Care Centers. The participants will be divided into two groups and five arms. The two groups are: 1) the patients´ preference group with two arms and 2) the randomized group with three arms. In the preference group, the two arms correspond to the two educational interventions (Intervention A and Intervention B) designed for this study. In the randomized group the three arms comprise: intervention A, intervention B and a control arm. Intervention A is written information (a leaflet describing the correct inhalation techniques). Intervention B is written information about inhalation techniques plus training by an instructor. Every patient in each group will be visited six times during the year of the study at health care center. DISCUSSION Our hypothesis is that the application of two educational interventions in patients with COPD who are treated with inhaled therapy will increase the number of patients who perform a correct inhalation technique by at least 25 %. We will evaluate the effectiveness of these interventions on patient inhalation technique improvement, considering that it will be adequate and feasible within the context of clinical practice.
Resumo:
The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.