886 resultados para Retinal Neovascularization
Resumo:
PURPOSE. To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. METHODS. SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. RESULTS. Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P 0.05). As a validation of that finding, SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P 0.243). However, SDRA revealed that smokers’ vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P 0.005) and an increased stiffness of retinal arterioles (P 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. CONCLUSIONS. SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.
Resumo:
The purpose of the following studies was to explore the effect of systemic vascular and endothelial dysfunction upon the ocular circulation and functionality of the retina. There are 6 principal sections to the present work. Retinal vessel activity in smokers and non-smokers: the principal findings of this work were: chronic smoking affects retinal vessel motion at baseline and during stimulation with flickering light; chronic smoking leads to a vaso-constrictory shift in retinal arteriolar reactivity to flicker; retinal arteriolar elasticity is decreased in chronic smokers. The effect of acute smoking on retinal vessel dynamics in smokers and non-smokers: the principal finding of this work was that retinal reactivity in chronic smokers is blunted when exposed to clicker light provocation immediately after smoking one cigarette. Ocular blood flow in coronary artery disease: The principal findings of this work were: retrobulbar and retinal blood flow is preserved in CAD patients, despite a change pulse wave transmission; arterial retinal response to flickering light provocation is significantly delayed in CAD patients; retinal venular diameters are significantly dilated in CAD patients. Autonomic nervous system function and peripheral circulation in CAD: The principal findings in this work were: CAD patients demonstrate a sympathetic overdrive during a 24 period; a delay in peripheral vascular reactivity (nail-fold capillaries) as observed in patients suffering from CAD could be caused by either arteriosclerotic changes of the vascular walls or due to systemic haemodynamic changes. Visual function in CAD: The principal findings in this work were: overall visual function in CAD patients is preserved, despite a decrease in contrast sensitivity; applying a filtering technique selecting those with greater coefficient of variance which in turn represents a decrease in reliability, some patients appear to have an impaired visual function as assessed using FDT visual field evaluation. Multiple functional, structural and biochemical vascular endothelial dysfunctions in patients suffering from CAD: relationships and possible implications: The principal findings of this work were: BMI significantly correlated with vWF (a marker of endothelial function) in CAD patients. Retinal vascular reactivity showed a significant correlation with peripheral reactivity parameters in controls which lacked in the CAD group and could reflect a loss in vascular endothelial integrity; visual field parameters as assessed by frequency doubling technology were strongly related with systemic vascular elasticity (ambulatory arterial stiffness index) in controls but not CAD patients.
Resumo:
To investigate the relationship between vascular function parameters measured at the retinal and systemic level and known markers for cardiovascular risk in patients with impaired glucose tolerance (IGT). Sixty age- and gender- matched White-European adults (30 IGT and 30 normal glucose tolerance -NGT) were recruited for the study. Fasting plasma glucose, lipids and 24-hour blood pressure (BP) was measured in all subjects. Systemic vascular and endothelial function was assessed using carotid-artery intimal media thickness (cIMT) and flow mediated dilation (FMD). Retinal vascular reactivity was assessed by the Dynamic Retinal Vessel Analyser (DVA). Additionally, blood glutathione (GSH, GSSG and tGSH) and plasma von-Willebrand (vWF) factor levels were also measured. Individuals with IGT demonstrated higher BP values (p<0.001), fasting TG and TG:HDL ratios (p<0.001) than NGT subjects. Furthermore, Total:HDL-C ratios and Framingham scores were raised (p=0.010 and p<0.001 respectively). Blood glutathione levels (GSH, GSSG and tGSH) were lower (p<0.001, p=0.039 and p<0.001 respectively) while plasma vWF was increased (p=0.014) in IGT subjects compared to controls. IGT individuals also demonstrated higher IMT in right and left carotid arteries (p=0.017 and p=0.005, respectively) alongside larger brachial artery diameter (p=0.015), lower FMD% (p=0.026) and GTN induced dilation (GID) (p=0.012) than healthy controls. At the retinal arterial level, the IGT subjects showed higher baseline fluctuations (BDF) (p=0.026), longer reaction time (RT) (p=0.032) and reduced baseline-corrected flicker response (bFR) (p=0.045). In IGT subjects retinal BDF correlated with and Total:HDL (p= 0.003) and HDL-C (p= 0.004). Arterial RT also correlated with FMD (p=0.017) in IGT but not NGT subjects. In IGT individuals there is a relationship between macro- and microvascular function, as well as a direct correlation between the observed retinal microcirculatory changes and established plasma markers for CVD. Multifactorial preventive interventions to decrease vascular risk in these individuals should be considered.
Resumo:
Purpose-To develop a non-invasive method for quantification of blood and pigment distributions across the posterior pole of the fundus from multispectral images using a computer-generated reflectance model of the fundus. Methods - A computer model was developed to simulate light interaction with the fundus at different wavelengths. The distribution of macular pigment (MP) and retinal haemoglobins in the fundus was obtained by comparing the model predictions with multispectral image data at each pixel. Fundus images were acquired from 16 healthy subjects from various ethnic backgrounds and parametric maps showing the distribution of MP and of retinal haemoglobins throughout the posterior pole were computed. Results - The relative distributions of MP and retinal haemoglobins in the subjects were successfully derived from multispectral images acquired at wavelengths 507, 525, 552, 585, 596, and 611?nm, providing certain conditions were met and eye movement between exposures was minimal. Recovery of other fundus pigments was not feasible and further development of the imaging technique and refinement of the software are necessary to understand the full potential of multispectral retinal image analysis. Conclusion - The distributions of MP and retinal haemoglobins obtained in this preliminary investigation are in good agreement with published data on normal subjects. The ongoing development of the imaging system should allow for absolute parameter values to be computed. A further study will investigate subjects with known pathologies to determine the effectiveness of the method as a screening and diagnostic tool.
Resumo:
Purpose: To report the outcome of retinal artery macroaneurysm associated with a congenital anomalous retinal artery. Methods: The patient was examined with ophthalmoscopy and fluorescein angiography. Results: A 60-year-old woman presented with visual acuity of 20/80 in her right eye. She was found to have an abnormal retinal vessel emerging from the optic disk, passing toward the center of the macula, and looping back toward the disk. The center of the loop had a leaking macroaneurysm, which was treated conservatively. At the 4-month follow-up visit, the visual acuity in the right eye had improved to 20/20 with resolution of most of the macular edema, exudates, and hemorrhage. Conclusion: This case demonstrates that retinal artery macroaneurysm can be successfully managed with a conservative approach, even when associated with a congenital anomalous retinal vessel.
Resumo:
Presentaton Purpose:We conducted a small study to assess the novel, retro - mode imaging technique of the NIDEK F-10 scanning laser ophthalmoscope, for detecting and quantifying retinal drusen. Methods:Fundus photographs of 4 eyes of 2 patients taken in retro-mode on the Nidek F-10 SLO were graded independently by 6,experienced, masked fundus graders for the presence of retinal drusen , and compared to stereo colour fundus photographs taken with a Topcon TRC-50DX camera. Results:The mean number of retinal drusen detected in retro mode was 142.96+/- 60.8, range 63-265, and on colour fundus photography mean of 66.6+/-32.6, range 26-177. All observers independently detected approximately twice as many drusen on retro-mode than colour fundus photography (p<0.0001, Student’s paired t-test) . The statistical significance of interobserver variation in drusen detection was p=0.07 on colour fundus photography , and p=0.02 on retro mode ( ANOVA) . Conclusions:The retro-mode of the F-10 camera uses infrared laser and an aperture with a modified central stop, with the aperture deviated laterally from the confocal light path. This forms a pseudo -3D image which is a new means of detecting abnomalites in the deeper retinal layers. Retro-mode imaging of retinal drusen using the F-10 Nidek SLO is a highly sensitive technique for detecting and quantifying retinal drusen , and detected twice as many drusen than colour fundus photography. This small pilot study suggests that this novel type of imaging may have a role in the future detection and analysis of retinal drusen, a field that is likely to become increasingly important in future AMD prevention studies.
Resumo:
Poster Introduction: In neovascular age-related macular degeneration (nAMD), optical coherence tomography (OCT) is an important tool to determine when intravitreal injections of ranibizumab should be administered. Current guidelines recommend that patients should be reviewed four weekly and OCT indications for further treatment include subretinal fluid and intraretinal fluid or cysts. Purpose: We have reviewed the OCT scans of subjects who have successfully responded to ranibizumab to look for factors that might predict which patients will not require injection and could have extended appointments. Method: This was a prospective study in which we observed for 6 consecutive months the OCT images of 28 subjects who had received intravitreal ranibizumab for nAMD and were judged to be clinically inactive at recruitment to the study. Ratios between full retinal thickness (FRT = neurosensory retina + outer reflective band) and outer reflective band (ORB) thickness at the fovea were calculated for each subject at the moment of entering the study and at each successive visit for 6 consecutive months. Results: Patients with lower FRT/ORB ratios were found to be less likely to require an additional injection of ranibizumab and no subject with a ratio of 1.75 or less needed further injections. Conclusion: This small pilot study suggests that on macular OCT, the FRT/ORB ratio, and in particular values of 1.75 or less, may prove to be a useful, practical tool when deciding the follow up period for subjects undergoing treatment with intravitreal ranibizumab for nAMD.
Resumo:
Introduction: We have adapted the existing , optometry diabetic retinopathy screening pathway and software , so that it can be used for wet AMD fast track referral. Purpose: To compare the conventional, optometry wet AMD fast track referral service using FAX transmission, with a teleophthalmology service using colour fundus photography transmitted to a central retinal grading centre. Method: 40 optometry practices involved in diabetic retinopathy screening were enrolled and had modified computer software installed. Referrals were made by conventional fast track FAX to the macular clinic, and patients were photographed by the optometrist and images transmitted to a central grading centre Results of the two pathways were compared in terms of 1)speed of diagnosis and 2)sensitivity and specificity of diagnosis of wet AMD. Results: Over a ten month period, 62 consecutive patients were referred. The mean time for conventional pathway was 20.8 days (range 3-34),and for new teleophthalmology pathway was 6.9 days (range 1-13). Sensitivity of technician grading of images was 96%, Specificity 53%, and consultant ophthalmologist was sensitivity 96%, specificiity 87%. The technician showed a learning effect with specificity increasing from 30.7% for first 31 patient cohort, to 70.6% for the second cohort. One patient had images that could not be graded. Conclusion: Rapid referral of wet AMD cases by optometrists using modified diabetic retinopathy screening software, allows fast and accurate diagnosis, and may reduce unnecessary referrals. Retinal grading technicians can be trained to grade wet AMD images.
Resumo:
Presentation Purpose:We conducted a study to determine if the spectral domain optical coherence tomography (SD-OCT) could be used as a tool to assess effective delivery of threshold and subthreshold laser burns created using 532nm green wavelength laser. Methods:10 patients planned for panretinal photocoagulation (PRP) for proliferative diabetic retinopathy were included in this study. Before initiating the full PRP, a row of moderately white laser burns as used for conventional PRP was created using 532 nm laser set at threshold power for 0.1 second with 300 microns spot size. Further rows of laser burns were created by altering the duration and power settings on the laser device. The area of the retina irradiated with laser was imaged using the Topcon SD-OCT within a few minutes of laser treatment. Results:Laser burns created using threshold power were seen on the OCT scan in all cases as a homogenous diffuse increase in reflectivity extending across the full thickness of retina (Fig 1). Retinal burns created by lowering the duration of laser pulse to 0.01s were barely visible ophthalmoscopically but were clearly detectable on the OCT scan as a localised, well-defined area of increased tissue reflectivity (Fig 2). Conclusions:OCT is a useful to tool to assess the delivery of laser burns created using the 532 nm green laser. Burns of a subthreshold intensity that may not be visible ophthalmoscopically result in retinal changes that are clearly detectable on OCT imaging. Further studies would be needed to assess the clinical effectiveness of subthreshold laser treatment for retinal vascular diseases using the 532 nm green laser.
Resumo:
Poster section Design. Retrospective study. Purpose. To assess whether there are changes in foveal thickness (FT) and total macular volume (TMV) in pregnancy in diabetic subjects. Methods. The audit consisted of pregnant women with diabetes, with no maculopathy, who completed their antenatal care at Birmingham Heartlands Hospital. The Zeiss Stratus Optical coherence tomography (OCT) was performed on patients attending diabetic retinopathy (DR) screening at intervals throughout their pregnancy. To be included in the audit patients had to have at least one OCT scan during their pregnancy. Results. Altogether there were 8 type 1 and 22 type 2 patients with mean diabetes duration of 6 years (range 1-20). Mean gestation at DR screening with OCT during the first trimester was 9.7 weeks (6-13) (n=22). The mean and standard deviation for FT for the right was 179.1 µm ± 21.49 and for the left eye was 187.3 µm ± 23.55. The mean TMV was right 6.43 µm ± 0.35 and left 6.50 µm ± 0.39. The mean gestation at DR screening with OCT during the second trimester was 23.4 weeks (18-26) (n=25). The mean FT for the right was 191.4 µm ± 22.70 and the left 195.6 µm ± 24.77. The mean TMV was right 6.74 µm ± 0.45 and left 6.91 µm ± 0.35. The gestation of DR screening with OCT during the third trimester was 31.1 weeks (27-36) (n=15). The mean FT for the right was 181.5 µm ± 24.84 and for the left 193.1 µm ± 28.55. The mean TMV was right 6.80 µm ± 0.40 and left 6.84 µm ± 0.31. There were no significant differences in FT over the 3 trimesters. The TMV showed a significant difference when comparing the first and second trimesters (p<0.05). However, there was no significant statistical difference in TMV in the second and third trimesters. None of the patients showed any macula edema on the OCT. Conclusions. The results suggest there is no significant change in foveal thickness in pregnancy in diabetic subjects. There was a significant statistical difference in total macular volume in the second trimester; however, this would not be clinically significant. This is an important observation proven by the OCT which has not been previously studied.
Resumo:
Lutein and zeaxanthin are lipid-soluble antioxidants found within the macula region of the retina. Links have been suggested between increased levels of these carotenoids and reduced risk for age-related macular disease (ARMD). Therefore, the effect of lutein-based supplementation on retinal and visual function in people with early stages of ARMD (age-related maculopathy, ARM) was assessed using multi-focal electroretinography (mfERG), contrast sensitivity and distance visual acuity. A total of fourteen participants were randomly allocated to either receive a lutein-based oral supplement (treated group) or no supplement (non-treated group). There were eight participants aged between 56 and 81 years (65·50 (sd 9·27) years) in the treated group and six participants aged between 61 and 83 years (69·67 (sd 7·52) years) in the non-treated group. Sample sizes provided 80 % power at the 5 % significance level. Participants attended for three visits (0, 20 and 40 weeks). At 60 weeks, the treated group attended a fourth visit following 20 weeks of supplement withdrawal. No changes were seen between the treated and non-treated groups during supplementation. Although not clinically significant, mfERG ring 3 N2 latency (P= 0·041) and ring 4 P1 latency (P= 0·016) increased, and a trend for reduction of mfERG amplitudes was observed in rings 1, 3 and 4 on supplement withdrawal. The statistically significant increase in mfERG latencies and the trend for reduced mfERG amplitudes on withdrawal are encouraging and may suggest a potentially beneficial effect of lutein-based supplementation in ARM-affected eyes. Copyright © 2012 The Authors.
Resumo:
Structural retinal vascular characteristics, such as vessel calibers, tortuosity and bifurcation angles are increasingly quantified in an objective manner, slowly replacing subjective qualitative disease classification schemes. This paper provides an overview of the current methodologies and calculations used to compute retinal vessel tortuosity. We set out the different parameter calculations and provide an insight into the clinical applications, while critically reviewing its pitfalls and shortcomings.
Resumo:
The Retinal Vessel Analyser (RVA) is a commercially available ophthalmoscopic instrument capable of acquiring vessel diameter fluctuations in real time and in high temporal resolution. Visual stimulation by means of flickering light is a unique exploration tool of neurovascular coupling in the human retina. Vessel reactivity as mediated by local vascular endothelial vasodilators and vasoconstrictors can be assessed non-invasively, in vivo. In brief, the work in this thesis • deals with interobserver and intraobserver reproducibility of the flicker responses in healthy volunteers • explains the superiority of individually analysed reactivity parameters over vendorgenerated output • links in static retinal measures with dynamic ones • highlights practical limitations in the use of the RVA that may undermine its clinical usefulness • provides recommendations for standardising measurements in terms of vessel location and vessel segment length and • presents three case reports of essential hypertensives in a -year follow-up. Strict standardisation of measurement procedures is a necessity when utilising the RVA system. Agreement between research groups on implemented protocols needs to be met, before it could be considered a clinically useful tool in detecting or predicting microvascular dysfunction.
Resumo:
To assess the impact of light scatter, similar to that introduced by cataract on retinal vessel blood oxygen saturation measurements using poly-bead solutions of varying concentrations. Eight healthy, young, non-smoking individuals were enrolled for this study. All subjects underwent digital blood pressure measurements, assessment of non-contact intraocular pressure, pupil dilation and retinal vessel oximetry using dual wavelength photography (Oximetry Module, Imedos Systems, Germany). To simulate light scatter, cells comprising a plastic collar and two plano lenses were filled with solutions of differing concentrations (0.001, 0.002 and 0.004%) of polystyrene microspheres (Polysciences Inc., USA). The adopted light scatter model showed an artifactual increase in venous optical density ratio (p=0.036), with the 0.004% condition producing significantly higher venous optical density ratio values when compared to images without a cell in place. Spectrophotometric analysis, and thus retinal vessel oximetry of the retinal vessels, is altered by artificial light scatter. © 2013 Elsevier Ltd.
Resumo:
Purpose: Diabetes is a leading cause of visual impairment in working age population in the UK. This study looked at the causes of Severe Visual Impairment(SVI) in the patients attending diabetic eye clinic and influence on the rate of SVI, over a 12 year period, after introducing retinal screening programmes in the hospital and the community in 1993 (review in 1992, 1998 & 2004). Methods: Medical records of all the patients attending the diabetic eye clinic over a period of 5months(April to August) in 1992, 1998 and 2004 were reviewed. The data collected for each patient included age, sex, ethnic origin, diabetes (type,duration &treatment), the best corrected visual acuity (present and at time of presentation), type and duration of retinopathy and attendance record to both diabetic clinic and diabetic eye clinic. In this study, SVI is defined as a visual acuity of 6/36 or worse in at least one eye. Results: In 1992, of a total 245 patients, 58patients(23.6%) had SVI {38 (15.5% of total) due to diabetic retinopathy [31(12.6%) maculopathy, 2(0.8%) vitreous haemorrhage and 5(2%) retinal detachment] and 20(8.1%) due to non–diabetic retinopathy causes}. In 1998, of a total 297, 77patients(25.9%) had SVI {33(11.1% of total) due to diabetic retinopathy [19(6.4%) maculopathy, 9(3%) proliferative retinopathy, 8(2.7%) vitreous haemorrhage and 3(1%) retinal detachment]and 44(14.8%)due to non–diabetic retinopathy}. In 2004, of a total 471, 72patients(15.2%) had SVI{46(9.7%of total) due to diabetic retinopathy [37(7.8%) maculopathy, 1(0.2%) proliferative retinopathy, 6(1.8%) vitreous haemorrhage and 2(0.4%) retinal detachment]and 26(5.5%) due to non– diabetic retinopathy causes}. Conclusions: Introduction of formalised annual diabetic review including retinal screening and a community retinal screening programme has reduced the rate of severe visual impairment due to diabetic retinopathy, in patients attending diabetic eye clinic, from 15.5% in1992 to 9.7% in2004. Keywords: diabetic retinopathy