971 resultados para Rapid diagnostic tests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To improve the accuracy and completeness of reporting of studies of diagnostic accuracy, to allow readers to assess the potential for bias in a study, and to evaluate a study's generalisability. Methods The Standards for Reporting of Diagnostic Accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a two day consensus meeting, with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. Results The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25 item checklist, by using evidence, whenever available. A prototype of a flow diagram provides information about the method of patient recruitment, the order of test execution, and the numbers of patients undergoing the test under evaluation and the reference standard, or both. Conclusions Evaluation of research depends on complete and accurate reporting. If medical journals adopt the STARD checklist and flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, we examined genetic and environmental influences on covariation among two reading tests used in neuropsychological assessment (Cambridge Contextual Reading Test [CCRT], [Beardsall, L., and Huppert, F. A. ( 1994). J. Clin. Exp. Neuropsychol. 16: 232 - 242], Schonell Graded Word Reading Test [SGWRT], [ Schonell, F. J., and Schonell, P. E. ( 1960). Diagnostic and attainment testing. Edinburgh: Oliver and Boyd.]) and among a selection of IQ subtests from the Multidimensional Aptitude Battery (MAB), [Jackson, D. N. (1984). Multidimensional aptitude battery, Ontario: Research Psychologists Press.] and the Wechsler Adult Intelligence Scale-Revised (WAIS-R) [Wechsler, D. (1981). Manual for the Wechsler Adult Intelligence Scale-Revised (WAIS-R). San Antonio: The Psychological Corporation]. Participants were 225 monozygotic and 275 dizygotic twin pairs aged from 15 years to 18 years ( mean, 16 years). For Verbal IQ subtests, phenotypic correlations with the reading tests ranged from 0.44 to 0.65. For Performance IQ subtests, phenotypic correlations with the reading tests ranged from 0.23 to 0.34. Results of Structural Equation Modeling (SEM) supported a model with one genetic General factor and three genetic group factors ( Verbal, Performance, Reading). Reading performance was influenced by the genetic General factor ( accounting for 13% and 20% of the variance for the CCRT and SGWRT, respectively), the genetic Verbal factor ( explaining 17% and 19% of variance for the CCRT and SGWRT), and the genetic Reading factor ( explaining 21% of the variance for both the CCRT and SGWRT). A common environment factor accounted for 25% and 14% of the CCRT and SGWRT variance, respectively. Genetic influences accounted for more than half of the phenotypic covariance between the reading tests and each of the IQ subtests. The heritabilities of the CCRT and SGWRT were 0.54 and 0.65, respectively. Observable covariance between reading assessments used by neuropsychologists to estimate IQ and IQ subtests appears to be largely due to genetic effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This paper describes SeqDoC, a simple, web-based tool to carry out direct comparison of ABI sequence chromatograms. This allows the rapid identification of single nucleotide polymorphisms (SNPs) and point mutations without the need to install or learn more complicated analysis software. Results: SeqDoC produces a subtracted trace showing differences between a reference and test chromatogram, and is optimised to emphasise those characteristic of single base changes. It automatically aligns sequences, and produces straightforward graphical output. The use of direct comparison of the sequence chromatograms means that artefacts introduced by automatic base-calling software are avoided. Homozygous and heterozygous substitutions and insertion/deletion events are all readily identified. SeqDoC successfully highlights nucleotide changes missed by the Staden package 'tracediff' program. Conclusion: SeqDoC is ideal for small-scale SNP identification, for identification of changes in random mutagenesis screens, and for verification of PCR amplification fidelity. Differences are highlighted, not interpreted, allowing the investigator to make the ultimate decision on the nature of the change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Test-retest reliabilities and practice affects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice affects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Rapid Screen of Concussion (RSC) is a brief psychometric test battery, designed to provide a functional criterion to aid clinical diagnosis of mild traumatic brain injury (mTBI). The present research aimed to examine the utility of this instrument for assessing recovery after mTBI. Three studies were conducted. In Study 1, Discriminant Function Analysis was performed to determine how well the RSC differentiated uninjured controls (N¼16), from mTBI patients (N¼22) and moderate to severe TBI patients (N¼14), several months post-injury. As predicted, moderate to severe TBI patients achieved lower scores than the mTBI and control groups. The RSC also successfully differentiated between each of the diagnostic groups, yielding an overall correct classification rate of 75%. Study 2 examined the predictive utility of the RSC in the mTBI sample (N¼22). Acute injury performance on the RSC was correlated with post-injury scores at an average of 5.5 months post-injury. Statistically significant partial correlation coefficients (r¼0.53r¼0.80) were found for each of the subtests, showing that low acute RSC scores were predictive of poor recovery scores on the RSC after mTBI. In the third study, Reliable Change Indices were calculated on the RSC subtests to examine individual patterns of recovery from mTBI. While 17 of the 23 participants made a significant improvement on their acute injury DSST scores (74%), only 13 of 25 made a significant improvement on the Rapid Sentence Judgement Test (52%), highlighting differential recovery of function, and challenging the notion of full recovery from mTBI within 3 months. These overall results offer support for the construct and predictive validity of the RSC and demonstrate that inexpensive tests of brain function may be useful for managing mTBI acutely for prognosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper is twofold: first, we compute quality-adjusted measures of productivity change for the three most important diagnostic technologies (i.e., the Computerised Tomography Scan, Electrocardiogram and Echocardiogram) in the major Portuguese hospitals. We use the Malmquist–Luenberger index, which allows to measure productivity growth while controlling for the quality of the production. Second, using non-parametric tests, we analyse whether the implementation of the Prospective Payment System may have had a positive impact on the movements of productivity over time. The results show that the PPS has helped hospitals to use these tools more efficiently and to improve their effectiveness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Self-tests are those where an individual can obtain a result without recourse to a health professional, by getting a result immediately or by sending a sample to a laboratory that returns the result directly. Self-tests can be diagnostic, for disease monitoring, or both. There are currently tests for more than 20 different conditions available to the UK public, and self-testing is marketed as a way of alerting people to serious health problems so they can seek medical help. Almost nothing is known about the extent to which people self-test for cancer or why they do this. Self-tests for cancer could alter perceptions of risk and health behaviour, cause psychological morbidity and have a significant impact on the demand for healthcare. This study aims to gain an understanding of the frequency of self-testing for cancer and characteristics of users. Methods: Cross-sectional survey. Adults registered in participating general practices in the West Midlands Region, will be asked to complete a questionnaire that will collect socio-demographic information and basic data regarding previous and potential future use of self-test kits. The only exclusions will be people who the GP feels it would be inappropriate to send a questionnaire, for example because they are unable to give informed consent. Freepost envelopes will be included and non-responders will receive one reminder. Standardised prevalence rates will be estimated. Discussion: Cancer related self-tests, currently available from pharmacies or over the Internet, include faecal occult blood tests (related to bowel cancer), prostate specific antigen tests (related to prostate cancer), breast cancer kits (self examination guide) and haematuria tests (related to urinary tract cancers). The effect of an increase in self-testing for cancer is unknown but may be considerable: it may affect the delivery of population based screening programmes; empower patients or cause unnecessary anxiety; reduce costs on existing healthcare services or increase demand to investigate patients with positive test results. It is important that more is known about the characteristics of those who are using self-tests if we are to determine the potential impact on health services and the public. © 2006 Wilson et al; licensee BioMed Central Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonics offers the possibility of developing sophisticated fluid manipulation tools in lab-on-a-chip technologies. Here we demonstrate the ability to shape ultrasonic fields by using phononic lattices, patterned on a disposable chip, to carry out the complex sequence of fluidic manipulations required to detect the rodent malaria parasite Plasmodium berghei in blood. To illustrate the different tools that are available to us, we used acoustic fields to produce the required rotational vortices that mechanically lyse both the red blood cells and the parasitic cells present in a drop of blood. This procedure was followed by the amplification of parasitic genomic sequences using different acoustic fields and frequencies to heat the sample and perform a real-time PCR amplification. The system does not require the use of lytic reagents nor enrichment steps, making it suitable for further integration into lab-on-a-chip point-of-care devices. This acoustic sample preparation and PCR enables us to detect ca. 30 parasites in a microliter-sized blood sample, which is the same order of magnitude in sensitivity as lab-based PCR tests. Unlike other lab-on-a-chip methods, where the sample moves through channels, here we use our ability to shape the acoustic fields in a frequency-dependent manner to provide different analytical functions. The methods also provide a clear route toward the integration of PCR to detect pathogens in a single handheld system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the accuracy and acceptability of polymerase chain reaction (PCR) and optical immunoassay (OIA) tests for the detection of maternal group B streptococcus (GBS) colonisation during labour, comparing their performance with the current UK policy of risk factor-based screening. Design Diagnostic test accuracy study. Setting and population Fourteen hundred women in labour at two large UK maternity units provided vaginal and rectal swabs for testing. Methods The PCR and OIA index tests were compared with the reference standard of selective enriched culture, assessed blind to index tests. Factors influencing neonatal GBS colonisation were assessed using multiple logistic regression, adjusting for antibiotic use. The acceptability of testing to participants was evaluated through a structured questionnaire administered after delivery. Main outcome measures The sensitivity and specificity of PCR, OIA and risk factor-based screening. Results Maternal GBS colonisation was 21% (19-24%) by combined vaginal and rectal swab enriched culture. PCR test of either vaginal or rectal swabs was more sensitive (84% [79-88%] versus 72% [65-77%]) and specific (87% [85-89%] versus 57% [53-60%]) than OIA (P <0.001), and far more sensitive (84 versus 30% [25-35%]) and specific (87 versus 80% [77-82%]) than risk factor-based screening (P <0.001). Maternal antibiotics (odds ratio, 0.22 [0.07-0.62]; P = 0.004) and a positive PCR test (odds ratio, 29.4 [15.8-54.8]; P <0.001) were strongly related to neonatal GBS colonisation, whereas risk factors were not (odds ratio, 1.44 [0.80-2.62]; P = 0.2). Conclusion Intrapartum PCR screening is a more accurate predictor of maternal and neonatal GBS colonisation than is OIA or risk factor-based screening, and is acceptable to women. © RCOG 2010 BJOG An International Journal of Obstetrics and Gynaecology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes work carried out to develop methods of verifying that machine tools are capable of machining parts to within specification, immediately before carrying out critical material removal operations, and with negligible impact on process times. A review of machine tool calibration and verification technologies identified that current techniques were not suitable due to requirements for significant time and skilled human intervention. A 'solution toolkit' is presented consisting of a selection circular tests and artefact probing which are able to rapidly verify the kinematic errors and in some cases also dynamic errors for different types of machine tool, as well as supplementary methods for tool and spindle error detection. A novel artefact probing process is introduced which simplifies data processing so that the process can be readily automated using only the native machine tool controller. Laboratory testing and industrial case studies are described which demonstrate the effectiveness of this approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the rapid globalization and integration of world capital markets, more and more stocks are listed in multiple markets. With multi-listed stocks, the traditional measurement of systematic risk, the domestic beta, is not appropriate since it only contain information from one market. ^ Prakash et al. (1993) developed a technique, the global beta, to capture information from multiple markets wherein the stocks are listed. In this study, the global betas are obtained as well as domestic betas for 704 multi-listed stocks from 59 world equity markets. Welch tests show that domestic betas are not equal across markets, therefore, global beta is more appropriate in a global investment setting. ^ The traditional Capital Asset Pricing Models (CAPM) is also tested with regards to both domestic beta and global beta. The results generally support the positive relationship between stocks returns and global beta while tend to reject this relationship between stocks returns and domestic beta. Further tests of International CAPM with domestic beta and global beta strengthen the conclusion.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing useof nanomaterials in consumer products and biomedical applications creates the possibilities of intentional/unintentional exposure to humans and the environment. Beyond the physiological limit, the nanomaterialexposure to humans can induce toxicity. It is difficult to define toxicity of nanoparticles on humans as it varies by nanomaterialcomposition, size, surface properties and the target organ/cell line. Traditional tests for nanomaterialtoxicity assessment are mostly based on bulk-colorimetric assays. In many studies, nanomaterials have found to interfere with assay-dye to produce false results and usually require several hours or days to collect results. Therefore, there is a clear need for alternative tools that can provide accurate, rapid, and sensitive measure of initial nanomaterialscreening. Recent advancement in single cell studies has suggested discovering cell properties not found earlier in traditional bulk assays. A complex phenomenon, like nanotoxicity, may become clearer when studied at the single cell level, including with small colonies of cells. Advances in lab-on-a-chip techniques have played a significant role in drug discoveries and biosensor applications, however, rarely explored for nanomaterialtoxicity assessment. We presented such cell-integrated chip-based approach that provided quantitative and rapid response of cellhealth, through electrochemical measurements. Moreover, the novel design of the device presented in this study was capable of capturing and analyzing the cells at a single cell and small cell-population level. We examined the change in exocytosis (i.e. neurotransmitterrelease) properties of a single PC12 cell, when exposed to CuOand TiO2 nanoparticles. We found both nanomaterials to interfere with the cell exocytosis function. We also studied the whole-cell response of a single-cell and a small cell-population simultaneously in real-time for the first time. The presented study can be a reference to the future research in the direction of nanotoxicity assessment to develop miniature, simple, and cost-effective tool for fast, quantitative measurements at high throughput level. The designed lab-on-a-chip device and measurement techniques utilized in the present work can be applied for the assessment of othernanoparticles' toxicity, as well.