991 resultados para ROOT-CANAL DENTIN
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Background: Tooh extraction was demonstrated to increase sympathetic modulation of the heart, however, it is not understood the effects of endodontic treatment on cardiac autonomic regulation. We evaluated heart rate variability (HRV) during endodontic treatment. Method: 50 male and female patients aged between 18 and 40 years old and diagnosed with irreversible pulpitis or pulp necrosis of the lower molars with indication of gender endodontic treatment were analyzed. HRV was analyzed in the time (SDNN, RMSSD, pNN50) and frequency (LF, HF and LF/HF ratio) domains recorded in the first session of root canal treatment. The indices were analyzed in the following periods: T1) ten minutes before the endodontic treatment, T2) ten minutes after the administration of anesthesia before endodontic treatment, T3) during the entire period of endodontic treatment and T4) thirty minutes after the end of the endodontic treatment. Results: The SDNN, RMSSD and pNN50 indices increased at T2 compared to T1, the pNN50 and RMSSD indices increased at T3 and T4 compared to T2. The LF in normalized units increased at T4 compared to T2 and in absolute units it was increased at T4 compared to T1. The HF in normalized units was reduced at T4 compared to T2 and in absolute units was reduced at T1, T3 and T4 compared to T2. The LF/HF ratio was higher at T4 compared to T2. Conclusion: The global modulation of heart increases after local anesthesia and vagal tone reduce during surgery procedures and after the surgical procedures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: This study sought to assess if discoloration of tooth structures occurs after photodynamic therapy (PDT) and to determine the efficacy of a protocol to remove the photosensitizers. Background data: PDT has been used in root canal treatment to enhance cleaning and disinfection of the root canal system. PDT uses a low power laser in association with a dye as a photosensitizer. Photosensitizers can induce staining of the dental structures, resulting in an unaesthetic appearance. Methods: Forty teeth were randomly divided into four groups according to the photosensitizer used and pre-irradiation time: 0.01% methylene blue for 5 min (MB5); 0.01% methylene blue for 10 min (MB 10); 0.01% toluidine blue for 5 min (TB5); and 0.01% toluidine blue for 10 min (TB 10). Specimens were irradiated with a 660 nm diode laser with a 300 mu m diameter optical fiber, at 40 mW power setting for 3 min. Immediately after, the photosensitizers were removed with Endo-PTC cream +2.5% sodium hypochlorite (NaOCl). The shade was measured by a Vita Easyshade spectrophotometer based on the CIELAB color system (L*a*b* values) at three different experimental times: before PDT (T0), immediately after PDT (T1), and after removal of the photosensitizer (T2). Results: The results showed a decrease in the averages of the L*a*b* coordinate values after PDT (T1) in all the groups, when compared with the number at T0, with a significant statistical difference in group MB10. After photosensitizer removal (T2), all the values of the coordinates increased with significant statistical differences (p < 0.05) between T1 and T2 in L* and a*. Conclusions: It can be concluded that both methylene blue and toluidine blue dyes cause tooth discoloration, and that Endo-PTC cream associated with 2.5% NaOCl effectively remove these dyes, regardless of the pre-irradiation time used for PDT.
Resumo:
Aim To assess (i) heat generated by pluggers during warm vertical compaction of gutta-percha and investigation of temperature changes on the external root surface during canal filling, and (ii) the chemical changes of root canal sealers induced by heat.Methodology Four sealers, namely AH Plus, MTA Plus and two other experimental sealers based on tricalcium silicate, were characterised. External temperatures generated on the root surface during warm vertical compaction of gutta-percha with different sealers inside the root canal were monitored using an infrared thermography camera. Chemical changes induced by heating the sealers were assessed by Fourier transform infrared (FT-IR) spectroscopy.Results MTA Plus and the experimental sealers were composed of a cement and radiopacifier, with epoxy resin or a water-soluble polymer as dispersant, whilst AH Plus was epoxy resin-based. The heat generated at the tips of the continuous wave pluggers was found to be lower than the temperature set and indicated on the device LCD display. The sealers reduced the heat generated on the external root surfaces during the heating phase. AH Plus sustained changes to its chemical structure after exposure to heat, whilst the other sealers were unaffected.Conclusions The temperatures recorded at the tips of continuous wave pluggers varied with their taper and were lower than the temperature set on the System B LCD display. Root canal sealers reduced the dissipation of heat generated during warm vertical compaction, with the temperature at the external root surface maintained at 37-41 degrees C, a temperature below that is necessary to cause irreversible damage to bone and periodontium. The use of AH Plus sealer during warm vertical compaction techniques results in chemical changes in the sealer. The effect on sealer properties needs to be further investigated.
Resumo:
The purpose of this study was to evaluate in vitro antimicrobial activity of chlorhexidine gel and liquid 2%, and 2% sodium hypochlorite on Candida albicans, Enterococcus faecalis, Escherichia coli in root canals. For this, we used 40 human single-rooted teeth were divided into 4 groups (n = 10) according to assist the chemical used: 1) 2% chlorhexidine liquid, 2) 2% chlorhexidine gel, 3) sodium hypochlorite 2%, and 4) physiological saline (control). Content were collected immediately after root canal instrumentation and after 7 days of biomechanical. For the samples was conducted to evaluate the antimicrobial activity and the results were subjected to statistical analysis of Kruskal-Wallis and Dunn's test with a significance of 5%. It was found that chlorhexidine gel and liquid as well as sodium hypochlorite were effective against the microorganisms tested
Resumo:
The aim of this study it was to evaluate the use of irrigating solution used during root canal preparation on the adhesive cementation of prefabricated fiberglass pins. The bond strength between different regions of the root and the fiberglass pins cemented into the root canal were evaluated by push-out assay. For this study, 36 human teeth were used, all equally prepared. The irrigating solutions used for biomechanical preparation were: saline solution, sodium hypochlorite 2,5% and glycolic extract of salvia 20%. The dual cure resin cement was used for cementation of pins. After cementation, specimens were sectioned to give 3 slices of approximately 2 mm each (cervical, middle and apical), which were submitted to mechanical push-out test. Were performed ANOVA and Tukey's test with a significance level of 5%, for the analysis of mechanical test. Comparing the thirds we observed that the only solution that presented statistical difference in the bond strength was sodium hypochlorite, which showed higher values for the middle and apical third compared with the cervical third, but when compared without taking into consideration the dental thirds, solutions studied showed no differences in bond strength. Therefore, it was concluded that the solutions studied can be used during endodontic treatment without causing harmful effects on the final adhesive restoration
Resumo:
The purpose of this study was to evaluate the antimicrobial activity of chlorhexidine gel 2% as auxiliary chemical substance on the biomechanical preparation (BMP) and medication intracanal (ICM) on C. albicans, E. faecalis, E. coli and their endotoxin in root canals. We used 48 single-rooted human teeth divided into four groups according to dressing ICM: 1) Ca(OH)2 + pyrogen-free saline solution; 2) 2% chlorhexidine gel (CLX); 3) Ca(OH)2 + CLX, and; 4) pyrogen-free saline solution (control group). Were collected the contents of root canals to confirm the presence of microorganisms (confirmation), immediately after instrumentation (1st collection), after 7 days of the BMP (2nd collection), after 14 days of the action of ICM (3rd Collection) and 7 days after removal of the ICM (4 th collection). Were performed: the evaluation of antimicrobial activity and the content analysis of endotoxins for all sampling tests. The results were statistically analyzed using Kruskall-Wallis and Dunn tests with a significance of 5%. It was found that the CLX as auxiliary chemical substance has significantly reduced microorganisms confirmation collection when compared. In relation to the neutralization of endotoxin, it was found that the 1st and 2nd collections presented a decrease of 92.03% and 98.10% in mean percentage respectively, when compared to the confirmation collection. In the 3rd and 4th samplings, the Ca (OH)2 + CLX group showed the best results. It was concluded that the BMP and the ICM were able to eliminate the tested microrganisms, however, they were not able to completely eliminate endotoxins root canal
Resumo:
The maxillary lateral incisor has a very peculiar and internal morphology that can be influenced by the its external anatomy such as supernumerary roots and ruts deep root, which often hinders an effective endodontic treatment. Generally, this tooth have a single root with one root canal, but teeth with two to four channels can be found. The main canal can present ramifications such as accessory canals, laterals, collaterals, recorrents and apical deltas. All this factors interfere directally on endodonthics treatment. The objective of this work is a study of the internal anatomy of the maxillary lateral incisors by digital and conventional radiographics methods, comparing the results obteined by each method Six hundred upper lateral incisor were used in this study teeth of the collection of the Department of Anatomy ICT – UNESP. All the teeth were radiographed by vestibular face, using a digital radiographic unit(Dabi Atlante). After this step, all the teeth underwent by conventional radiographic technique(Kodak 2200) so that the results obtained were compared. To classify the channel system, it was adopted the classification of Pucci and Reig. All data obtained by digital technique were compared with those obtained in the conventional technique and were subjected to statistical analysis
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.