918 resultados para ROBOTIC ARM
Resumo:
The major trans (1) and minor cis (2) isomers of 1,4,8,11-tetraazacyclotetradecane-6,13-dicarboxylate have been characterized as the complexes [Co(1)](ClO4) and [Co(H-2)(OH2)]Cl(ClO4).H2O. The former crystallized in the C-2/c space group and the latter in the P2(1)/c space group, with cell parameters a 16.258(7), b 9.050(3), c 15.413(6) Angstrom, beta133.29(3)degrees, and a 9.694(4), b 16.135(1), c 12.973(5) Angstrom, beta 93.00(2)degrees, respectively. Their characterization completes identification of the respective trans and cis isomers for the series of C-pendant macrocycles also including 1,4,8,11-tetraazacyclotetradecane-6-amine-13-carboxylate ((3), (4)) and 1,4,8,11-tetraazacyclotetradecane-6,13-diamine ((5), (6)). The complexes show limited distortion from octahedral geometry with the strain in the presence of the coordinated C-pendant carboxylate significantly reduced compared with that for the C-pendant amine in analogues, a consequence mainly of six-membered as opposed to five-membered chelate rings involving the pendant donor. A comparison of the physical properties for the trans isomers of the octahedral complexes of (1), (3), and (5), which reflect progressively increasing strain, is presented.
Resumo:
Novas ferramentas de Tecnologias Assistivas (TAs) têm aparecido ultimamente. Um exemplo são os Ambientes Virtuais (AVs), os quais são importantes para o desenvolvimento de novas TAs, que podem ser direcionadas para promoverem uma melhor qualidade de vida de pessoas com mobilidade reduzida permanente ou promover a reabilitação de pessoas com deficiência motora temporária. Outras ferramentas, que surgiram há algumas décadas com o desenvolvimento dos computadores, também ajudam no tratamento de pessoas com deficiência motora, que são as Interfaces Humano-Máquina (IHM). Utilizando em conjunto com equipamentos que capturam sinais biológicos, como equipamentos de Eletromiografia (EMG) e Eletroencefalografia (EEG), essas ferramentas se configuram como canais de comunicações entre o ser humano e os computadores, diferentemente das comumente utilizadas. Isso abre uma gama de possibilidades para sua utilização no tratamento e na assistência de pessoas com deficiência motora, onde sinais EMG podem ser utilizados para controlar próteses robóticas; e sinais EEG, quando capturados da região do córtex motor, podem ser utilizados em neuroreabilitação. Por outro lado, quando capturados na região occipital, os sinais de EEG podem ser utilizados para gerar comandos e outras finalidades. Este trabalho apresenta o desenvolvimento de novas ferramentas para auxiliar em pesquisas de TAs envolvendo sinais biológicos. Três diferentes AVs foram desenvolvidos para auxiliar nesse tipo de pesquisa. Além deles, um equipamento EEG comercial foi adaptado para ser utilizado com uma IHM, o qual utiliza dois desses três AVs desenvolvidos. Como resultados, temos a utilização bem sucedida do equipamento EEG obtido com sua utilização com SSVEP e Imaginação motora, além da implementação com sucesso dos três AVs desenvolvidos, que estão disponíveis para download gratuito, e que podem ser utilizados em demais pesquisas envolvendo TAs.
Resumo:
O Acidente Vascular Cerebral (AVC) é uma das principais causas de prejuízos ao sistema neuromuscular. Dispositivos Robóticos vêm sendo amplamente desenvolvidos e estudados com a finalidade de serem utilizados na assistência à marcha e para o treinamento da marcha durante a reabilitação. O objetivo deste trabalho é avaliar a marcha assistida pelo AROW (Assistive Robotic Walker) em indivíduos hemiparéticos pós-AVC, através da análise de sinais de acelerometria e sinais mioelétricos de superfície (sEMG) provenientes dos músculos vasto medial (VM), bíceps femoral (BF), tibial anterior (TA) e gastrocnêmio medial (GM), e também utilizando os métodos de avaliação GAS (Goal Attainment Scaling) e SUS (System Usability Scale). Nove indivíduos hemiparéticos participaram dos testes. A velocidade da marcha foi reduzida com o uso do AROW e, consequentemente, houve algumas alterações na duração das fases da marcha, por exemplo, uma maior duração da fase de apoio (p = 0,0174). O padrão de ativação muscular para o grupo analisado não apresentou diferença estatisticamente significativa (início da ativação VM: p= 0,4999; término da ativação VM: p= 0,5647; início BF: p= 0,1186; término BF: p= 0,7823; início TA: p= 0,5833; término TA: p= 0,8393; início GM: p= 0,6077; término GM: p= 0,1429). Entretanto, avaliando o padrão de ativação muscular individualmente, podem-se notar algumas alterações benéficas, por exemplo, redução da coativação dos músculos tibial anterior e gastrocnêmio medial. Os resultados das avaliações através do GAS (54,8) e SUS (81,4) sobre o uso do AROW mostraram boa aceitação pelos usuários, e os objetivos esperados durante o uso do andador foram atingidos. A adaptação rápida, facilidade de utilização e sentimento de segurança ao usar o dispositivo são pontos positivos obtidos com o uso do AROW.
Resumo:
This paper proposes a wireless EEG acquisition platform based on Open Multimedia Architecture Platform (OMAP) embedded system. A high-impedance active dry electrode was tested for improving the scalp- electrode interface. It was used the sigma-delta ADS1298 analog-to-digital converter, and developed a “kernelspace” character driver to manage the communications between the converter unit and the OMAP’s ARM core. The acquired EEG signal data is processed by a “userspace” application, which accesses the driver’s memory, saves the data to a SD-card and transmits them through a wireless TCP/IP-socket to a PC. The electrodes were tested through the alpha wave replacement phenomenon. The experimental results presented the expected alpha rhythm (8-13 Hz) reactiveness to the eyes opening task. The driver spends about 725 μs to acquire and store the data samples. The application takes about 244 μs to get the data from the driver and 1.4 ms to save it in the SD-card. A WiFi throughput of 12.8Mbps was measured which results in a transmission time of 5 ms for 512 kb of data. The embedded system consumes about 200 mAh when wireless off and 400 mAh when it is on. The system exhibits a reliable performance to record EEG signals and transmit them wirelessly. Besides the microcontroller-based architectures, the proposed platform demonstrates that powerful ARM processors running embedded operating systems can be programmed with real-time constrains at the kernel level in order to control hardware, while maintaining their parallel processing abilities in high level software applications.
Resumo:
No atual modelo de agricultura, é indispensável que o produtor conheça a real disponibilidade de tempo para a execução das operações agrícolas ao longo do ciclo das culturas. Este é o primeiro passo para se planejar e se obter maior eficiência na execução dessas operações, que estão sujeitas às variações do clima. As variáveis meteorológicas de uma determinada região influenciam diretamente no número de dias disponíveis para trabalhar com máquinas agrícolas. O objetivo deste trabalho foi estimar as probabilidades de ocorrência de dias favoráveis para o trabalho mecanizado, utilizando-se informações meteorológicas do município de Santa Maria, RS, Brasil. As condições para se considerar o dia como favorável para o trabalho com máquinas foram a precipitação < 5 mm e o armazenamento de água no solo (ARM) entre 40 e 90% da capacidade de água disponível (CAD). O método da cadeia de Markov de primeira ordem foi utilizado para estimar as probabilidades condicionais de dias favoráveis ao trabalho com máquinas. Os resultados indicam que a metodologia aplicada para estimar as probabilidades de dias favoráveis ao uso de máquinas agrícolas foi viável, evidenciando as épocas mais apropriadas à execução de operações agrícolas mecanizadas no campo, para o município de Santa Maria, RS.
Resumo:
Storm- and tsunami-deposits are generated by similar depositional mechanisms making their discrimination hard to establish using classic sedimentologic methods. Here we propose an original approach to identify tsunami-induced deposits by combining numerical simulation and rock magnetism. To test our method, we investigate the tsunami deposit of the Boca do Rio estuary generated by the 1755 earthquake in Lisbon which is well described in the literature. We first test the 1755 tsunami scenario using a numerical inundation model to provide physical parameters for the tsunami wave. Then we use concentration (MS. SIRM) and grain size (chi(ARM), ARM, B1/2, ARM/SIRM) sensitive magnetic proxies coupled with SEM microscopy to unravel the magnetic mineralogy of the tsunami-induced deposit and its associated depositional mechanisms. In order to study the connection between the tsunami deposit and the different sedimentologic units present in the estuary, magnetic data were processed by multivariate statistical analyses. Our numerical simulation show a large inundation of the estuary with flow depths varying from 0.5 to 6 m and run up of similar to 7 m. Magnetic data show a dominance of paramagnetic minerals (quartz) mixed with lesser amount of ferromagnetic minerals, namely titanomagnetite and titanohematite both of a detrital origin and reworked from the underlying units. Multivariate statistical analyses indicate a better connection between the tsunami-induced deposit and a mixture of Units C and D. All these results point to a scenario where the energy released by the tsunami wave was strong enough to overtop and erode important amount of sand from the littoral dune and mixed it with reworked materials from underlying layers at least 1 m in depth. The method tested here represents an original and promising tool to identify tsunami-induced deposits in similar embayed beach environments.
Resumo:
O trabalho apresentado nesta dissertação refere-se à concepção, projecto e realização experimental de um conversor estático de potência tolerante a falhas. Foram analisados trabalhos de investigação sobre modos de falha de conversores electrónicos de potência, topologias de conversores tolerantes a falhas, métodos de detecção de falhas, entre outros. Com vista à concepção de uma solução, foram nomeados e analisados os principais modos de falhas para três soluções propostas de conversores com topologias tolerantes a falhas onde existem elementos redundantes em modo de espera. Foram analisados os vários aspectos de natureza técnica dos circuitos de potência e guiamento de sinais onde se salientam a necessidade de tempos mortos entre os sinais de disparo de IGBT do mesmo ramo, o isolamento galvânico entre os vários andares de disparo, a necessidade de minimizar as auto-induções entre o condensador DC e os braços do conversor de potência. Com vista a melhorar a fiabilidade e segurança de funcionamento do conversor estático de potência tolerante a falhas, foi concebido um circuito electrónico permitindo a aceleração da actuação normal de contactores e outro circuito responsável pelo encaminhamento e inibição dos sinais de disparo. Para a aplicação do conversor estático de potência tolerante a falhas desenvolvido num accionamento com um motor de corrente contínua, foi implementado um algoritmo de controlo numa placa de processamento digital de sinais (DSP), sendo a supervisão e actuação do sistema realizados em tempo-real, para a detecção de falhas e actuação de contactores e controlo de corrente e velocidade do motor utilizando uma estratégia de comando PWM. Foram realizados ensaios que, mediante uma detecção adequada de falhas, realiza a comutação entre blocos de conversores de potência. São apresentados e discutidos resultados experimentais, obtidos usando o protótipo laboratorial.
Resumo:
Storm- and tsunami-deposits are generated by similar depositional mechanisms making their discrimination hard to establish using classic sedimentologic methods. Here we propose an original approach to identify tsunami-induced deposits by combining numerical simulation and rock magnetism. To test our method, we investigate the tsunami deposit of the Boca do Rio estuary generated by the 1755 earthquake in Lisbon which is well described in the literature. We first test the 1755 tsunami scenario using a numerical inundation model to provide physical parameters for the tsunami wave. Then we use concentration (MS. SIRM) and grain size (chi(ARM), ARM, B1/2, ARM/SIRM) sensitive magnetic proxies coupled with SEM microscopy to unravel the magnetic mineralogy of the tsunami-induced deposit and its associated depositional mechanisms. In order to study the connection between the tsunami deposit and the different sedimentologic units present in the estuary, magnetic data were processed by multivariate statistical analyses. Our numerical simulation show a large inundation of the estuary with flow depths varying from 0.5 to 6 m and run up of similar to 7 m. Magnetic data show a dominance of paramagnetic minerals (quartz) mixed with lesser amount of ferromagnetic minerals, namely titanomagnetite and titanohematite both of a detrital origin and reworked from the underlying units. Multivariate statistical analyses indicate a better connection between the tsunami-induced deposit and a mixture of Units C and D. All these results point to a scenario where the energy released by the tsunami wave was strong enough to overtop and erode important amount of sand from the littoral dune and mixed it with reworked materials from underlying layers at least 1 m in depth. The method tested here represents an original and promising tool to identify tsunami-induced deposits in similar embayed beach environments.
Resumo:
Introdução – A medição da pressão arterial (PA), utilizando dispositivos automáticos, é frequentemente realizada na prática clínica e na automedição, permitindo adquirir informação fiável para o diagnóstico, controlo e tratamento da hipertensão arterial. Porém, muitos dos dispositivos automáticos disponíveis no mercado não estão validados segundo protocolos existentes para o efeito. O objetivo do estudo foi confirmar a validação do dispositivo de medição automática da PA, OMRON® M6 Comfort, segundo o Protocolo Internacional da European Society of Hypertension (ESH), de 2010, para a validação de dispositivos de medição automática da PA em adultos. Metodologia – Foram estudados 33 indivíduos, aos quais foram realizadas 9 medições sequenciais da PA, no braço esquerdo, com um esfignomanómetro aneróide alternando com o dispositivo automático. Seguidamente avaliaram-se as diferenças entre os valores obtidos pelos dispositivos para a pressão arterial sistólica (PAS) e diastólica (PAD), classificando-as em três níveis (≤ 5, ≤ 10 ou ≤ 15 mmHg). O número das diferenças em cada nível foi comparado ao requerido pelo Protocolo (fase 1.1). Para cada sujeito foi ainda determinado o número de diferenças com valores ≤ 5 mmHg. Pelo menos 24 dos 33 indivíduos devem ter 2 ou 3 diferenças com valores ≤ 5 mmHg e no máximo 3 dos 33 indivíduos podem apresentar as 3 diferenças com valores > 5 mmHg (fase 1.2). Resultados – O dispositivo OMRON® M6 Comfort foi aprovado nas fases 1.1 e 1.2 para a PAS e PAD. A média das diferenças entre as medições da PA, determinada pelos dispositivos automático e manual, foi de -0,82 ± 5,62 mmHg para a PAS e 2,14 ± 5,15 mmHg para a PAD. Considerações Finais – O dispositivo OMRON® M6 Comfort é válido para a medição da PA em adultos, de acordo com o Protocolo Internacional da ESH, de 2010. - ABSTRACT - Introduction – The measurement of blood pressure (BP) using automatic devices is often performed in clinical practice and self-measurement allowing the acquisition of reliable information for the diagnosis, monitoring and treatment of hypertension. However not all of the automated devices available in the market are validated in accordance with the existing protocols for this purpose. The purpose of this study was to confirm the validation of the automatic measuring device of the BP, OMRON® M6 Comfort, according to the “European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults”. Methodology – The study involved 33 subjects, in each one of them, 9 sequential measurements of BP were performed, in the left arm, with the aneroid sphygmomanometer alternating with the automatic device. Afterwards, the differences on the values obtained by the different devices were evaluated, for systolic blood pressure (SBP) and diastolic (DBP), and these differences were then classified into three levels (≤ 5, ≤ 10 or ≤ 15 mmHg). The number of differences at each level was compared to the number required by the protocol (phase 1.1). For each subject the number of differences with values ≤ 5 mmHg was also determined. At least 24 of the 33 subjects should have 2 or 3 differences with values ≤ 5 mmHg and a maximum of 3 of the 33 subjects may have all differences with values > 5 mmHg (phase 1.2). Results – The device OMRON M6 Comfort ® was approved in phases 1.1 and 1.2 for SBP and DBP. The average difference between measurements of BP, as determined by automatic and manual devices, was -0.82 ± 5.62 mmHg for SBP and 2.14 ± 5.15 mmHg for DBP. Conclusion – The device OMRON M6 Comfort® is valid for measuring BP in adults, according to the ESH International Protocol of 2010.
Resumo:
O diagnóstico de doença hepática autoimune em doentes com patologia hepática implica a exclusão de outras causas de lesão hepática como vírica, alcoólica, tóxica, devido a alterações genéticas ou metabólicas, esteatose hepática não alcoólica e uma criteriosa avaliação de dados clínicos, bioquímicos, histológicos e colangiográficos especificas destas patologias (Invernizzi et al 2007) O diagnóstico e tratamento precoces destas patologias são fundamentais para a prevenção da alta morbilidade e mortalidade associada a estes doentes. O despiste de patologia hepática autoimune assenta na utilização de testes serológicos para a deteção de autoanticorpos associados a estas patologias. O conhecimento destes testes e a interpretação dos resultados obtidos revelam-se fundamentais para o diagnóstico ou exclusão destas doenças (Beuers 2005). Deste modo, foi objetivo deste trabalho a pesquisa e identificação de autoanticorpos em uso clínico: ANA, AMA, AML, ANCA, Anti-SLA/LP, anti-LKM, anti-LC1 e anti-actina F, em doentes com suspeita de HAI e CBP em que foi excluída causa vírica, alcoólica e tóxica. O trabalho incidiu particularmente na comparação dos resultados do perfil de autoanticorpos de pedidos feitos ao exterior com os resultados obtidos recorrendo à utilização de um novo kit de imunoblot, e assim determinar a relevância da introdução da pesquisa dos novos autoanticorpos e avaliar a relação custo/benefício da implementação do kit BlueDot liver da D-tek® na rotina laboratorial do serviço de Patologia Clínica do Hospital Pedro Hispano. Os resultados encontrados foram de 100% de concordância entre os métodos de imunofluorescência indireta e imunoblot, e Elisa e Imunoblot. Deste modo seria uma boa estratégia a implementação desta última técnica na rotina laboratorial uma vez que proporciona uma rápida disponibilização dos resultados para o clínico, antecipando desta forma o diagnóstico e o início rápido do tratamento em benefício do doente. Por outro lado, quando analisámos a relação custo/beneficio, seria vantajosa a implementação desta técnica uma vez que o laboratório dispõe de capacidade técnica, e o custo de aquisição do kit não excede o valor praticado atualmente correspondendo a uma poupança de 51%.
Resumo:
Storm- and tsunami-deposits are generated by similar depositional mechanisms making their discrimination hard to establish using classic sedimentologic methods. Here we propose an original approach to identify tsunami-induced deposits by combining numerical simulation and rock magnetism. To test our method, we investigate the tsunami deposit of the Boca do Rio estuary generated by the 1755 earthquake in Lisbon which is well described in the literature. We first test the 1755 tsunami scenario using a numerical inundation model to provide physical parameters for the tsunami wave. Then we use concentration (MS. SIRM) and grain size (chi(ARM), ARM, B1/2, ARM/SIRM) sensitive magnetic proxies coupled with SEM microscopy to unravel the magnetic mineralogy of the tsunami-induced deposit and its associated depositional mechanisms. In order to study the connection between the tsunami deposit and the different sedimentologic units present in the estuary, magnetic data were processed by multivariate statistical analyses. Our numerical simulation show a large inundation of the estuary with flow depths varying from 0.5 to 6 m and run up of similar to 7 m. Magnetic data show a dominance of paramagnetic minerals (quartz) mixed with lesser amount of ferromagnetic minerals, namely titanomagnetite and titanohematite both of a detrital origin and reworked from the underlying units. Multivariate statistical analyses indicate a better connection between the tsunami-induced deposit and a mixture of Units C and D. All these results point to a scenario where the energy released by the tsunami wave was strong enough to overtop and erode important amount of sand from the littoral dune and mixed it with reworked materials from underlying layers at least 1 m in depth. The method tested here represents an original and promising tool to identify tsunami-induced deposits in similar embayed beach environments.
Resumo:
Neonatal anthropometry is an inexpensive, noninvasive and convenient tool for bedside evaluation, especially in sick and fragile neonates. Anthropometry can be used in neonates as a tool for several purposes: diagnosis of foetal malnutrition and prediction of early postnatal complications; postnatal assessment of growth, body composition and nutritional status; prediction of long-term complications including metabolic syndrome; assessment of dysmorphology; and estimation of body surface. However, in this age group anthropometry has been notorious for its inaccuracy and the main concern is to make validated indices available. Direct measurements, such as body weight, length and body circumferences are the most commonly used measurements for nutritional assessment in clinical practice and in field studies. Body weight is the most reliable anthropometric measurement and therefore is often used alone in the assessment of the nutritional status, despite not reflecting body composition. Derived indices from direct measurements have been proposed to improve the accuracy of anthropometry. Equations based on body weight and length, mid-arm circumference/head circumference ratio, and upper-arm cross-sectional areas are among the most used derived indices to assess nutritional status and body proportionality, even though these indices require further validation for the estimation of body composition in neonates.
Resumo:
RESUMO: Introdução – A evolução tecnológica permitiu uma deteção precoce do cancro e, consequentemente, uma abordagem terapêutica mais eficaz e efetiva, resultando no aumento da sobrevida dos doentes. Assim, pretende-se avaliar a influência da radioterapia na qualidade de vida dos doentes com cancro da mama. Metodologia – 47 participantes que efetuaram radioterapia no Centro Hospitalar Barreiro-Montijo preencheram os dois questionários, o EORTC QLQ-C30 e o QLQ-BR23, antes de iniciar radioterapia e no último dia do tratamento. Os resultados foram analisados através do programa informático SPSS, versão 19.0. Resultados – Observou-se um ligeiro decréscimo na qualidade da saúde global no segundo momento de avaliação. Verificou-se uma diminuição nas escalas sintomática e funcional no segundo momento de avaliação. Em relação ao questionário QLQ-BR23, na escala sintomática, observou-se uma diminuição nos efeitos secundários resultantes da radioterapia no último momento de avaliação. Discussão dos Resultados – Os resultados obtidos no questionário QLQ-C30 revelam que a avaliação global da saúde dos doentes não é influenciada pelo tratamento de radioterapia. Em relação ao questionário QLQ-BR23, os sintomas relacionados com a mama e o braço tiveram um aumento ligeiramente significativo no segundo momento de avaliação, sendo estes associados à radioterapia. De acordo com os resultados obtidos, a radioterapia não influencia a qualidade de vida em doentes com cancro da mama.
Resumo:
Mestrado em Fisioterapia.
Resumo:
Mestrado em Fisioterapia