972 resultados para Quality tools


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho realizado sob orientação do Prof. António Brandão Moniz para a disciplina “Factores Sociais da Inovação” do Mestrado Engenharia Informática realizado na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, para a obtenção do grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis submitted to the Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia for the degree of Doctor of Philosophy in Environmental Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado integrado em Engenharia do Ambiente, perfil: Gestão de Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To examine whether religiousness mediates the relationship between sociodemographic factors, multimorbidity and health-related quality of life of older adults.METHODS This population-based cross-sectional study is part of the Survey on Health, Well-Being, and Aging (SABE). The sample was composed by 911 older adults from Sao Paulo, SP, Southeastern Brazil. Structural equation modeling was performed to assess the mediator effect of religiousness on the relationship between selected variables and health-related quality of life of older adults, with models for men and women. The independent variables were: age, education, family functioning and multimorbidity. The outcome variable was health-related quality of life of older adults, measured by SF-12 (physical and mental components). The mediator variables were organizational, non-organizational and intrinsic religiousness. Cronbach’s alpha values were: physical component = 0.85; mental component = 0.80; intrinsic religiousness = 0.89 and family APGAR (Adaptability, Partnership, Growth, Affection, and Resolve) = 0.91.RESULTS Higher levels of organizational and intrinsic religiousness were associated with better physical and mental components. Higher education, better family functioning and fewer diseases contributed directly to improved performance in physical and mental components, regardless of religiousness. For women, organizational religiousness mediated the relationship between age and physical (β = 2.401, p < 0.01) and mental (β = 1.663, p < 0.01) components. For men, intrinsic religiousness mediated the relationship between education and mental component (β = 7.158, p < 0.01).CONCLUSIONS Organizational and intrinsic religiousness had a beneficial effect on the relationship between age, education and health-related quality of life of these older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTOBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context.METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants.RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods.CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drilling of polymeric matrix composite structures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To validate an instrument designed to assess health promotion in the school environment. METHODS A questionnaire, based on guidelines from the World Health Organization and in line with the Brazilian school health context, was developed to validate the research instrument. There were 60 items in the instrument that included 40 questions for the school manager and 20 items with direct observations made by the interviewer. The items’ content validation was performed using the Delphi technique, with the instrument being applied in 53 schools from two medium-sized cities in the South region of Brazil. Reliability (Cronbach’s alpha and split-half) and validity (principal component analysis) analyses were performed. RESULTS The final instrument remained composed of 28 items, distributed into three dimensions: pedagogical, structural and relational. The resulting components showed good factorial loads (> 0.4) and acceptable reliability (> 0.6) for most items. The pedagogical dimension identifies educational activities regarding drugs and sexuality, violence and prejudice, auto care and peace and quality of life. The structural dimension is comprised of access, sanitary structure, and conservation and equipment. The relational dimension includes relationships within the school and with the community. CONCLUSIONS The proposed instrument presents satisfactory validity and reliability values, which include aspects relevant to promote health in schools. Its use allows the description of the health promotion conditions to which students from each educational institution are exposed. Because this instrument includes items directly observed by the investigator, it should only be used during periods when there are full and regular activities at the school in question.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews the literature for lowering of dose to paediatric patients through use of exposure factors and additional filtration. Dose reference levels set by The International Commission on Radiological Protection (ICRP) will be considered. Guidance was put in place in 1996 requires updating to come into line with modern imaging equipment. There is a wide range of literature that specifies that grids should not be used on paediatric patients. Although much of the literature advocates additional filtration, contrasting views on the relative benefits of using aluminium or copper filtration, and their effects on dose reduction and image quality can vary. Changing kVp and mAs has an effect on the dose to the patient and image quality. Collimation protects adjacent structures whilst reducing scattered radiation.