666 resultados para Plexus ganglionnaire cardiaque intrinsèque
Resumo:
Drugs and surgery can interfere with the biodistribution of radiopharmaceuticals and data about the effect of splenectomy on the metabolism of phytate-Tc-99m are scarce. This study aimed at evaluating the interference of splenectomy on phytate-Tc-99m biodistribution and liver function in rats. The SP group rats (n=6) underwent splenectomy. In group C (control) the animals were not operated on. After 15 days, all rats were injected with 0.1mL of Tc-99m-phytate via orbital plexus (0.66MBq). After 30 minutes, liver samples were harvested, weighed and the percentage of radioactivity per gram (%ATI-g) was determined by a Wizard Perkin-Elme gama counter. The ATI%-g in splenectomized rats (0.99±0.02) was significantly higher than in controls (0.4±0.02), (p=0.034). ALT, AST and HDL were significantly lower in SP rats (p= 0.001) and leukocytosis was observed in SP rats. In conclusion, splenectomy in rats changed the hepatic biodistribution of Tc-99m-phytate and liver enzimatic activity
Resumo:
To evaluate the biodistribution of sodium pertecnetate (Na99mTcO4) in organs and tissues, the morphometry of remnant intestinal mucosa and ponderal evolution in rats subjected to massive resection of the small intestine. Methods: Twenty-one Wistar rats were randomly divided into three groups of 7 animals each. The short bowel (SB) group was subjected to massive resection of the small intestine; the control group (C) rats were not operated on, and soft intestinal handling was performed in sham rats. The animals were weighed weekly. On the 30th postoperative day, 0.l mL of Na99mTcO4, with mean activity of 0.66 MBq was injected intravenously into the orbital plexus. After 30 minutes, the rats were killed with an overdose of anesthetic, and fragments of the liver, spleen, pancreas, stomach, duodenum, small intestine, thyroid, lung, heart, kidney, bladder, muscle, femur and brain were harvested. The biopsies were washed with 0.9% NaCl.,The radioactivity was counted using Gama Counter WizardTM 1470, PerkinElmer. The percentage of radioactivity per gram of tissue (%ATI-g) was calculated. Biopsies of the remaining jejunum were analysed by HE staining to obtain mucosal thickness. Analysis of variance (ANOVA) and the Tukey test for multiple comparisons were used, considering p<0.05 as signifi cant. Results: There were no signifi cant differences in %ATI-g of the Na99mTcO4 in the organs of the groups studied (p>0.05). An increase in the weight of the SB rats was observed after the second postoperative week. The jejunal mucosal thickness of the SB rats was signifi cantly greater than that of C and sham rats (p<0.05). Conclusion: In rats with experimentally-produced short bowel syndrome, an adaptive response by the intestinal mucosa reduced weight loss. The biodistribution of Na99mTcO4 was not affected by massive intestinal resection, suggesting that short bowel syndrome is not the cause of misleading interpretation, if an examination using this radiopharmaceutical is indicated
Resumo:
O objetivo deste trabalho foi analisar a distribuição dos vasos arteriais nos testículos em caprinos com diferentes graus de divisão escrotal. A configuração escrotal foi classificada da seguinte forma: Grupo I: constituído por caprinos com escroto único, Grupo II: com escroto separado até a metade do testículo e Grupo III: com separação escrotal estendendo-se além da metade do testículos. As artérias foram injetadas e coradas com solução de acetado de vinil, sendo os orgãos (30 pares) submetidos à corrossão para obtenção dos moldes vasculares. As artérias testiculares emergem da aorta abdominal, com trajeto retilíneo, atravessam o canal inguinal, apresentam-se espiraladas e envolvidas parcialmente pelo plexo pampiniforme. Próximo à extremidade caudada do testículo, dividem-se mais freqüentemente nos ramos cranial e caudal, os quais emitem vasos colaterais, de onde emergem ramos penetrantes. Os testículos dos animais com nível intermediário de divisão escrotal (Grupo II) apresentam menor quantidade destes ramos, sendo os quadrantes mais povoados o ventrolateral e o dorsolateral. Conclui-se que a origem, o trajeto e a distribuição das artérias testiculares não apresentam variações relacionadas ao grau de divisão escrotal em caprinos.
Resumo:
Les peptides et protéines extracteurs de lipides (PEL) se lient aux membranes lipidiques puis en extraient des lipides en formant de plus petits auto-assemblages, un phénomène qui peut aller jusqu'à la fragmentation des membranes. Dans la nature, cette extraction se produit sur une gamme de cellules et entraîne des conséquences variées, comme la modification de la composition de la membrane et la mort de la cellule. Cette thèse se penche sur l’extraction lipidique, ou fragmentation, induite par le peptide mélittine et la protéine Binder-of-SPerm 1 (BSP1) sur des membranes lipidiques modèles. Pour ce faire, des liposomes de différentes compositions sont préparés et incubés avec la mélittine ou la BSP1. L'association aux membranes est déterminée par la fluorescence intrinsèque des PEL, tandis que l'extraction est caractérisée par une plateforme analytique combinant des tests colorimétriques et des analyses en chromatographie en phase liquide et spectrométrie de masse (LCMS). La mélittine fait partie des peptides antimicrobiens cationiques, un groupe de PEL très répandu chez les organismes vivants. Ces peptides sont intéressants du point du vue médical étant donné leur mode d’action qui vise directement les lipides des membranes. Plusieurs de ceux-ci agissent sur les membranes des bactéries selon le mécanisme dit « en tapis », par lequel ils s’adsorbent à leur surface, forment des pores et ultimement causent leur fragmentation. Dans cette thèse, la mélittine est utilisée comme peptide modèle afin d’étudier le mécanisme par lequel les peptides antimicrobiens cationiques fragmentent les membranes. Les résultats montrent que la fragmentation des membranes de phosphatidylcholines (PC) est réduite par une déméthylation graduelle de leur groupement ammonium. L'analyse du matériel fragmenté révèle que les PC sont préférentiellement extraites des membranes, dû à un enrichissement local en PC autour de la mélittine à l'intérieur de la membrane. De plus, un analogue de la mélittine, dont la majorité des résidus cationiques sont neutralisés, est utilisé pour évaluer le rôle du caractère cationique de la mélittine native. La neutralisation augmente l'affinité du peptide pour les membranes neutres et anioniques, réduit la fragmentation des membranes neutres et augmente la fragmentation des membranes anioniques. Malgré les interactions électrostatiques entre le peptide cationique et les lipides anioniques, aucune spécificité lipidique n'est observée dans l'extraction. La BSP1 est la protéine la plus abondante du liquide séminal bovin et constitue un autre exemple de PEL naturel important. Elle se mélange aux spermatozoïdes lors de l’éjaculation et extrait des lipides de leur membrane, notamment le cholestérol et les phosphatidylcholines. Cette étape cruciale modifie la composition lipidique de la membrane du spermatozoïde, ce qui faciliterait par la suite la fécondation de l’ovule. Cependant, le contact prolongé de la protéine avec les spermatozoïdes endommagerait la semence. Cette thèse cherche donc à approfondir notre compréhension de ce délicat phénomène en étudiant le mécanisme moléculaire par lequel la protéine fragmente les membranes lipidiques. Les résultats des présents travaux permettent de proposer un mécanisme d’extraction lipidique en 3 étapes : 1) L'association à l’interface des membranes; 2) La relocalisation de l’interface vers le cœur lipidique; 3) La fragmentation des membranes. La BSP1 se lie directement à deux PC à l'interface; une quantité suffisante de PC dans les membranes est nécessaire pour permettre l'association et la fragmentation. Cette liaison spécifique ne mène généralement pas à une extraction lipidique sélective. L'impact des insaturations des chaînes lipidiques, de la présence de lysophosphatidylcholines, de phosphatidyléthanolamine, de cholestérol et de lipides anioniques est également évalué. Les présentes observations soulignent la complexe relation entre l'affinité d'un PEL pour une membrane et le niveau de fragmentation qu'il induit. L'importance de la relocalisation des PEL de l'interface vers le cœur hydrophobe des membranes pour permettre leur fragmentation est réitérée. Cette fragmentation semble s'accompagner d'une extraction lipidique préférentielle seulement lorsqu'une séparation de phase est induite au niveau de la membrane, nonobstant les interactions spécifiques PEL-lipide. Les prévalences des structures amphiphiles chez certains PEL, ainsi que de la fragmentation en auto-assemblages discoïdaux sont discutées. Finalement, le rôle des interactions électrostatiques entre les peptides antimicrobiens cationiques et les membranes bactériennes anioniques est nuancé : les résidus chargés diminueraient l'association des peptides aux membranes neutres suite à l'augmentation de leur énergie de solvatation.
Resumo:
FTY720 (aussi connu sous le nom de Fingolimod ou Gilenya) agit sur les récepteurs sphingosine-1-phosphate (S1P) et induit la suppression du système immunitaire (immunosuppression). Cette molécule est reconnue pour avoir une activité contre plusieurs cellules cancéreuses. Cette activité est indépendante de l’action sur les récepteurs S1P et on attribue plutôt la mort (apoptose) des cellules cancéreuse à la capacité que possède la molécule à réduire le transport des nutriments dans la cellule. Toutefois, malgré ses nombreux avantages, FTY720 ne peut pas être utilisé afin de traiter des humains puisque l’activation secondaire des récepteurs S1P1 et S1P3 mènent à une diminution du rythme cardiaque (bradycardie) chez les patients. Notre groupe s’est donc concentré sur la synthèse d’analogues qui potentiellement n’activeraient pas le récepteur S1P tout en gardant une activité biologique contre plusieurs cellules cancéreuses. Malgré le fait que nos analogues agissent également sur la diminution du transport des nutriments dans les cellules, nous ne connaissons pas le mécanisme d’action par lequel ceux-ci agissent. Au passage, le projet de recherche ci-présenté nous aura par ailleurs permis de développer une grande variété de sondes photo-actives dans l’espoir d’isoler une ou plusieurs protéines qui seraient impliquées dans le mécanisme d’action.
Resumo:
Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale.
Resumo:
Background General anaesthesia and regional anaesthesia have been used successfully for upper extremity orthopaedic procedures. Despite the advantages of regional anaesthesia, there is low utilisation in Nigeria. In this study, we assessed the types of anaesthesia employed for upper extremity surgeries in our centre. Methods After obtaining approval from the institutional ethics committee, all the patients who had upper extremity surgeries from 1 January 2011 to 31 December 2012 were included in this review. Both prospective and retrospective data were gathered. The choice of anaesthesia was at the discretion of the attending anaesthetist. Results A total of 226 patients with a male-to-female ratio of 1.6:1 and median age of 35.0 (range 2 – 89) years, had orthopaedic upper extremity procedures during the study period. Sixty-three cases (27.9%) had general anaesthesia, 5 (2.2%) combined regional and general anaesthesia while 158 (69.9%) had regional blocks. The regional blocks comprised 145 (89%) different approaches to the brachial plexus and 18 (11%) local anaesthetic infiltrations. The arm was the site mostly operated upon; while supraclavicular and axillary brachial plexus blocks were performed in equal amounts. In 14 (6.2%) patients, brachial plexus blocks were performed with spinal anaesthesia because of concomitant iliac crest bone grafts. While the duration of surgery did not differ significantly, regional anaesthesia provided a significantly longer duration of anaesthesia than general anaesthesia (251 ± 70.8 min versus 141.3 ± 65.5 min; p = 0.0000001). Conclusion There is a high use of regional anaesthesia for upper extremity orthopaedic surgeries in our centre, which is a positive development in a resource limited setting.
Resumo:
National audience
Resumo:
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle.
Resumo:
Les maladies cardiovasculaires ont un impact considérable sur la vie des Canadiens, et de nombreux efforts ont permis d’identifier différents facteurs de risque associés à cette condition. L’hypertension artérielle représente un de ces facteurs modifiables les plus importants. Quoique l’hypertension est définie à l’aide de mesures de pression artérielle en périphérie, il devient de plus en plus apparent que la mesure de pression centrale et de ses composantes auraient des avantages au niveau de la prédiction de la survenue d’événements cardiovasculaires. Le présent mémoire vise à mieux caractériser deux déterminants de cette pression centrale, le traitement antihypertenseur à base de bêtabloqueurs et l’insuffisance rénale chronique précoce. En utilisant les données recueillies dans la banque de données populationnelle CARTaGENE, il a été possible à l’aide d’analyses statistiques par appariement basé sur le coefficient de propension de démontrer que l’utilisation d’agents antihypertensifs de type bêtabloqueurs était associée à un profil hémodynamique central défavorable. Ainsi, les individus recevant ces agents avaient une pression centrale et une amplification artérielle plus élevées que des individus du groupe contrôle apparié et ce, malgré une pression périphérique identique. Cet effet semblait être incomplètement expliqué par la réduction du rythme cardiaque associé à l’utilisation de bêtabloqueurs. Aussi, il a été démontré que l’insuffisance rénale chronique de stade 3 (débit de filtration glomérulaire estimé entre 30 et 60 mL/min/1.73m2) n’était pas associée à une élévation des paramètres hémodynamiques centraux, contrairement à ce qui avait déjà été décrit chez des individus avec insuffisance rénale chronique plus avancée. De plus, le niveau d’albuminurie ne serait également pas associé à un changement du profil central dans un sous-groupe de la cohorte CARTaGENE.
Resumo:
Les troubles respiratoires du sommeil ont une prévalence élevée dans la population générale, l’apnée obstructive du sommeil étant le plus important de ces troubles. Malgré tout, une grande proportion des patients avec apnée ne sont pas diagnostiqués. La méthode la plus complète pour diagnostiquer l’apnée est l’enregistrement d’une nuit de sommeil par polysomnographie, aussi appelée enregistrement de type 1, qui est un processus long et coûteux. Pour surmonter ces difficultés, des appareils d’enregistrements portables (ou de type 3) ont été développés. Toutefois, ces enregistrements de type 3 ne capturent pas l’activité cérébrale, mesurée avec l’électroencéphalographie (EEG). Le présent mémoire décrit une étude comparative entre les enregistrements de type 1 et de type 3. Tous les événements respiratoires d’apnée, d’hypopnée et d’éveils liés à un effort respiratoire (RERA, en anglais) seront analysés ainsi que les éveils cérébraux (ou éveils EEG) et les éveils autonomiques. Ces éveils autonomiques se définissent par une hausse de la fréquence cardiaque suite à un événement respiratoire. Pour enrichir les analyses, les variables respiratoires suivantes ont été étudiées : une chute de la saturation en oxygène de 4 % (ODI), l’index d’apnée-hypopnée (IAH), l’indice de perturbations respiratoires avec apnées + hypopnées + RERAs et les éveils EEG (RDIe, en anglais) et le RDI incluant les éveils autonomiques définis par une augmentation de la fréquence cardiaque de 5 bpm (RDIa5). L’objectif de la présente étude est d’évaluer la proportion d’événements respiratoires avec éveils autonomiques ainsi que leur impact sur le RDI des enregistrements de type 1 et 3. L’hypothèse suggère que les événements avec éveils autonomiques auraient un plus grand impact sur le RDI des enregistrements de type 3 contrairement au type 1. Cette étude inclut 72 sujets ayant suivi un enregistrement de polysomnographie complète de type 1 ainsi que 79 sujets différents ayant suivi un enregistrement ambulatoire de type 3. Les analyses suivantes ont été effectuées : 1) les pourcentages d’événements associés avec seulement des éveils autonomiques dans les enregistrements de type 1 et de type 3 ; 2) les fréquences de migration entre les catégories basses et élevées de sévérité de l’AHI en prenant en compte les événements associés avec seulement des éveils autonomiques ; 3) les Bland-Altman (B-A) pour mesurer l’accord entre l’AHI, le RDIe et le RDIa5 (type 1), et entre l’AHI et le RDIa5 (type 3) et ; 4) les corrélations de Pearson et les coefficients de corrélation intraclasse (ICC) pour mesurer l’accord entre l’AHI, le RDIe et le RDIa5 (type 1), et entre l’AHI et le RDIa5 (type 3). L’utilisation du critère de RDIa5 permet d’ajouter 49 % d’événements comptés avec l’AHI pour les enregistrements de type 1, et 51 % d’événements pour ceux de type 3. La présente étude montre que les éveils autonomiques ont un impact similaire autant pour le RDI des enregistrements de type 3 que de type 1. En conclusion, on peut affirmer que le RDIa5 est acceptable et fiable pour les enregistrements de type 3.
Resumo:
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle.
Resumo:
Les maladies cardiovasculaires ont un impact considérable sur la vie des Canadiens, et de nombreux efforts ont permis d’identifier différents facteurs de risque associés à cette condition. L’hypertension artérielle représente un de ces facteurs modifiables les plus importants. Quoique l’hypertension est définie à l’aide de mesures de pression artérielle en périphérie, il devient de plus en plus apparent que la mesure de pression centrale et de ses composantes auraient des avantages au niveau de la prédiction de la survenue d’événements cardiovasculaires. Le présent mémoire vise à mieux caractériser deux déterminants de cette pression centrale, le traitement antihypertenseur à base de bêtabloqueurs et l’insuffisance rénale chronique précoce. En utilisant les données recueillies dans la banque de données populationnelle CARTaGENE, il a été possible à l’aide d’analyses statistiques par appariement basé sur le coefficient de propension de démontrer que l’utilisation d’agents antihypertensifs de type bêtabloqueurs était associée à un profil hémodynamique central défavorable. Ainsi, les individus recevant ces agents avaient une pression centrale et une amplification artérielle plus élevées que des individus du groupe contrôle apparié et ce, malgré une pression périphérique identique. Cet effet semblait être incomplètement expliqué par la réduction du rythme cardiaque associé à l’utilisation de bêtabloqueurs. Aussi, il a été démontré que l’insuffisance rénale chronique de stade 3 (débit de filtration glomérulaire estimé entre 30 et 60 mL/min/1.73m2) n’était pas associée à une élévation des paramètres hémodynamiques centraux, contrairement à ce qui avait déjà été décrit chez des individus avec insuffisance rénale chronique plus avancée. De plus, le niveau d’albuminurie ne serait également pas associé à un changement du profil central dans un sous-groupe de la cohorte CARTaGENE.
Resumo:
Les troubles respiratoires du sommeil ont une prévalence élevée dans la population générale, l’apnée obstructive du sommeil étant le plus important de ces troubles. Malgré tout, une grande proportion des patients avec apnée ne sont pas diagnostiqués. La méthode la plus complète pour diagnostiquer l’apnée est l’enregistrement d’une nuit de sommeil par polysomnographie, aussi appelée enregistrement de type 1, qui est un processus long et coûteux. Pour surmonter ces difficultés, des appareils d’enregistrements portables (ou de type 3) ont été développés. Toutefois, ces enregistrements de type 3 ne capturent pas l’activité cérébrale, mesurée avec l’électroencéphalographie (EEG). Le présent mémoire décrit une étude comparative entre les enregistrements de type 1 et de type 3. Tous les événements respiratoires d’apnée, d’hypopnée et d’éveils liés à un effort respiratoire (RERA, en anglais) seront analysés ainsi que les éveils cérébraux (ou éveils EEG) et les éveils autonomiques. Ces éveils autonomiques se définissent par une hausse de la fréquence cardiaque suite à un événement respiratoire. Pour enrichir les analyses, les variables respiratoires suivantes ont été étudiées : une chute de la saturation en oxygène de 4 % (ODI), l’index d’apnée-hypopnée (IAH), l’indice de perturbations respiratoires avec apnées + hypopnées + RERAs et les éveils EEG (RDIe, en anglais) et le RDI incluant les éveils autonomiques définis par une augmentation de la fréquence cardiaque de 5 bpm (RDIa5). L’objectif de la présente étude est d’évaluer la proportion d’événements respiratoires avec éveils autonomiques ainsi que leur impact sur le RDI des enregistrements de type 1 et 3. L’hypothèse suggère que les événements avec éveils autonomiques auraient un plus grand impact sur le RDI des enregistrements de type 3 contrairement au type 1. Cette étude inclut 72 sujets ayant suivi un enregistrement de polysomnographie complète de type 1 ainsi que 79 sujets différents ayant suivi un enregistrement ambulatoire de type 3. Les analyses suivantes ont été effectuées : 1) les pourcentages d’événements associés avec seulement des éveils autonomiques dans les enregistrements de type 1 et de type 3 ; 2) les fréquences de migration entre les catégories basses et élevées de sévérité de l’AHI en prenant en compte les événements associés avec seulement des éveils autonomiques ; 3) les Bland-Altman (B-A) pour mesurer l’accord entre l’AHI, le RDIe et le RDIa5 (type 1), et entre l’AHI et le RDIa5 (type 3) et ; 4) les corrélations de Pearson et les coefficients de corrélation intraclasse (ICC) pour mesurer l’accord entre l’AHI, le RDIe et le RDIa5 (type 1), et entre l’AHI et le RDIa5 (type 3). L’utilisation du critère de RDIa5 permet d’ajouter 49 % d’événements comptés avec l’AHI pour les enregistrements de type 1, et 51 % d’événements pour ceux de type 3. La présente étude montre que les éveils autonomiques ont un impact similaire autant pour le RDI des enregistrements de type 3 que de type 1. En conclusion, on peut affirmer que le RDIa5 est acceptable et fiable pour les enregistrements de type 3.
Resumo:
The rapid development of interventional procedures for the treatment of arrhythmias in humans, especially the use of catheter ablation techniques, has renewed interest in cardiac anatomy. Although the substrates of atrial fibrillation (AF), its initiation and maintenance, remain to be fully elucidated, catheter ablation in the left atrium (LA) has become a common therapeutic option for patients with this arrhythmia. Using ablation catheters, various isolation lines and focal targets are created, the majority of which are based on gross anatomical, electroanatomical, and myoarchitectual patterns of the left atrial wall. Our aim was therefore to review the gross morphological and architectural features of the LA and their relations to extracardiac structures. The latter have also become relevant because extracardiac complications of AF ablation can occur, due to injuries to the phrenic and vagal plexus nerves, adjacent coronary arteries, or the esophageal wall causing devastating consequences.