968 resultados para Planar auto-calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desarrollo empresarial y creación de empresa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desarrollo empresarial y creación de empresa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new Ultra-High Vacuum (UHV) reflectance spectrometer was successfully designed, making use of a Janis Industries ST-400 sample cryostat, IR Labs bolometer, and Briiker IFS 66 v/S spectrometer. Two of the noteworthy features include an in situ gold evaporator and internal reference path, both of which allow for the experiment to progress with a completely undisturbed sample position. As tested, the system was designed to operate between 4.2 K and 325 K over a frequency range of 60 - 670 cm~^. This frequency range can easily be extended through the addition of appUcable detectors. Tests were performed on SrTiOa, a highly ionic incipient ferroelectric insulator with a well known reflectance. The presence and temperatmre dependence of the lowest frequency "soft" mode were measured, as was the presence of the other two infrared modes. During the structural phase transition from cubic to tetragonal perovskite, the splitting of the second phonon mode was also observed. All of the collected data indicate good agreement with previous measurements, with a minor discrepency between the actual and recorded sample temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conjecture claiming that every planar graph is acyclic 5-choosable[Borodin et al., 2002] has been verified for several restricted classes of planargraphs. Recently, O. V. Borodin and A. O. Ivanova, [Journal of Graph Theory,68(2), October 2011, 169-176], have shown that a planar graph is acyclically 5-choosable if it does not contain an i-cycle adjacent to a j-cycle, where 3<=j<=5 if i=3 and 4<=j<=6 if i=4. We improve the above mentioned result and prove that every planar graph without an i-cycle adjacent to a j-cycle with3<=j<=5 if i=3 and 4<=j<=5 if i=4 is acyclically 5-choosable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we consider the properties of planar topological defects in unconventional superconductors. Specifically, we calculate microscopically the interaction energy of domain walls separating degenerate ground states in a chiral p-wave fermionic superfluid. The interaction is mediated by the quasiparticles experiencing Andreev scattering at the domain walls. As a by-product, we derive a useful general expression for the free energy of an arbitrary nonuniform texture of the order parameter in terms of the quasiparticle scattering matrix. The thesis is structured as follows. We begin with a historical review of the theories of superconductivity (Sec. 1.1), which led the way to the celebrated Bardeen-Cooper- Schrieffer (BCS) theory (Sec. 1.3). Then we proceed to the treatment of superconductors with so-called "unconventional pairing" in Sec. 1.4, and in Sec. 1.5 we introduce the specific case of chiral p-wave superconductivity. After introducing in Sec. 2 the domain wall (DW) model that will be considered throughout the work, we derive the Bogoliubov-de Gennes (BdG) equations in Sec. 3.1, which determine the quasiparticle excitation spectrum for a nonuniform superconductor. In this work, we use the semiclassical (Andreev) approximation, and solve the Andreev equations (which are a particular case of the BdG equations) in Sec. 4 to determine the quasiparticle spectrum for both the single- and two-DW textures. The Andreev equations are derived in Sec. 3.2, and the formal properties of the Andreev scattering coefficients are discussed in the following subsection. In Sec. 5, we use the transfer matrix method to relate the interaction energy of the DWs to the scattering matrix of the Bogoliubov quasiparticles. This facilitates the derivation of an analytical expression for the interaction energy between the two DWs in Sec. 5.3. Finally, to illustrate the general applicability our method, we apply it in Sec. 6 to the interaction between phase solitons in a two-band s-wave superconductor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the List Colouring Conjecture, if G is a multigraph then χ' (G)=χl' (G) . In this thesis, we discuss a relaxed version of this conjecture that every simple graph G is edge-(∆ + 1)-choosable as by Vizing’s Theorem ∆(G) ≤χ' (G)≤∆(G) + 1. We prove that if G is a planar graph without 7-cycles with ∆(G)≠5,6 , or without adjacent 4-cycles with ∆(G)≠5, or with no 3-cycles adjacent to 5-cycles, then G is edge-(∆ + 1)-choosable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the synthesis and use of an N-substituted ferrocene bearing a proline-derived chiral directing group and diastereoselective lithiation-electrophile quench of the pro-Sp hydrogen of the ferrocene to give planar chiral products in >95:5 dr. The auxiliary group is found to be stable to lithium bases of types RLi and R2NLi giving the same diastereoselectivity. The anti- epimer of the previously mentioned syn auxiliary induces lithiation of pro Rp rather than pro Sp hydrogen in >95:5 dr. Upon electrophile quench and elimination, the enantiomer of the syn-derived planar chiral imidazolone is obtained. Hence, this method provides a practical way to prepare planar chiral enantiomers in this series without the use of a more expensive D-proline derived starting material. The syn and anti epimers have β, γ-stereogenic centers and the origin of stereoselectivity in lithiation appears to be driven by the conformational bias exerted by the β-silyloxy moiety in each chiral auxiliary. In the thesis, this conclusion is supported using insensitivity of lithiation selectivity to the bulkiness of the base, comparison of enantiomers, deuteration experiments, nOe difference studies and computational modeling of the ground states and lithiation transition states for both substrates. The products are then converted to ligand precursors to make iridium and rhodium complexes. Among them, one of the cationic iridium complex is found to be effective in the asymmetric hydrogenation of 2-substituted quinolines with enantioselectivities up to 80% at pressures as low as 5 atm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias de Ingeniería Eléctrica con Especialidad en Electrónica) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Administración con Especialidad en Recursos Humanos) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias de Enfermería con Énfasis en Administración de Servicios) UANL, 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en ciencias de enfermería) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Orientación en Materiales de Construcción) UANL, 2012.