982 resultados para P element susceptibility


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with what a source precisely sees when it drives a receiver such as a continuous structural object. An equivalent lumped element system consisting of masses, springs and dampers is developed to visually represent the operational structural dynamics of a single-input structure at the driving point. The development is solely based on the mobility model of the driving point response. The mobility model is mathematically inverted to give the impedance model that is suitable for lumped element modeling. The two types of structures studied are unconstrained inertial objects and constrained resilient objects. The lumped element systems presented suggest a new view to dynamics that a single-input flexible structure in operation can be decomposed into the two subsystems: a base system of single degree of freedom (or of a mass for an inertial object) whose mass is in contact with the source and an appendage system consisting of a series of oscillators each of which is attached to the base mass. The driving point response is a result of the coupling between the two subsystems. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Most clinical cases of osteomyelitis in dogs involve infectious agents, especially bacteria and fungi. The characterization of these microorganisms may aid in the prevention and treatment of disease.Objective: The aim of this study was to evaluate retrospectively microbiological cultures and in vitro antimicrobial susceptibility profile of isolates from 52 cases of bacterial osteomyelitis in long bones of dogs over 2000-2013. In 78% of the cases injuries were caused by a motor vehicle accident, but there were a few cases of dog bites (17%) and ascending infection due to pododermatitis (5%).Animals and methods: The isolated microorganisms were identified based on conventional phenotypic methods. In vitro disk diffusion test was performed using 30 different antimicrobials.Results: The isolates were obtained from femur (28%), humerus (16%), tibia (31%), and radius/ulna (25%). Among 52 cases, culture was positive in 88% of cases. Thirteen genus of different species of microorganisms were isolated. The most common microorganisms isolated were Staphylococcus spp. and Escherichia coli followed by Streptococcus spp., enteric bacteria, Corynebacterium sp. and anaerobic bacteria. In 42% of cases cultures were mixed. The most effective drugs against isolated bacteria were amoxicillin and clavulanate potassium (79%) followed by ceftriaxone (69%). High-resistance rates were documented against azithromycin (80%), penicillin (59%), and clindamycin (59%).Conclusions: The present study highlights diverse etiologic agents in cases of infectious bacterial osteomyelitis, with predominance of Staphylococcus genus, and reinforces the importance of obtaining cultures and susceptibility profiles given the high rates of antimicrobial resistance.