895 resultados para Oxygen.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, a new oxygenator (Dideco 903 [D903], Dideco, Mirandola, Italy) has been introduced to the perfusion community, and we set about testing its oxygen transfer performance and then comparing it to two other models. This evaluation was based on the comparison between oxygen transfer slope, gas phase arterial oxygen gradients, degree of blood shunting, maximum oxygen transfer, and diffusing capacity calculated for each membrane. Sixty patients were randomized into three groups of oxygenators (Dideco 703 [D703], Dideco; D903; and Quadrox, Jostra Medizintechnik AG, Hirrlingen, Germany) including 40/20 M/F of 68.6 +/- 11.3 years old, with a body weight of 71.5 +/- 12.1 kg, a body surface area (BSA) of 1.84 +/- 0.3 m(2), and a theoretical blood flow rate (index 2.4 times BSA) of 4.4 +/- 0.7 L/min. The maximum oxygen transfer (VO(2)) values were 313 mL O(2)/min (D703), 579 mL O(2)/min (D903), and 400 mL O(2)/min (Quadrox), with the D903 being the most superior (P < 0.05). Oxygen (O(2)) gradients were 320 mm Hg (D703), 235 mm Hg (D903), and 247 mm Hg (Quadrox), meaning D903 and Quadrox are more efficient versus the D703 (P < 0.05). Shunt fraction (Qs/Qt) and diffusing capacity (DmO(2)) were comparable (P = ns). Diffusing capacity values indexed to BSA (DmO(2)/m(2)) were 0.15 mL O(2)/min/mm Hg/m(2) (D703), 0.2 mL O(2)/min/mm Hg/m(2) (D903), and 0.18 mL O(2)/min/mm Hg/m(2) (Quadrox) with D903 outperforming D703 (P < 0.0005). During hypothermia (32.0 +/- 0.3 degrees C), there was a lower absolute and relative VO(2 )for all three oxygenators (P = ns). The O(2) gradients, DmO(2) and DmO(2)/m(2), were significantly lower for all oxygenators (P < 0.01). Also, Qs/Qt significantly rose for all oxygenators (P < 0.01). The oxygen transfer curve is characteristic to each oxygenator type and represents a tool to quantify oxygenator performance. Using this parameter, we demonstrated significant differences among commercially available oxygenators. However, all three oxygenators are considered to meet the oxygen needs of the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Low tissue oxygen tension is an important factor leading to the development of wound dehiscence and anastomotic leakage after colon surgery. We tested whether supplemental fluid and supplemental oxygen can increase tissue oxygen tension in healthy and injured, perianastomotic, and anastomotic colon in an acutely instrumented pig model of anastomosis surgery. METHODS: Sixteen Swiss Landrace pigs were anesthetized (isoflurane 0.8%-1%) and their lungs ventilated. The animals were randomly assigned to low fluid treatment ("low" group, 3 mL x kg(-1) x h(-1) lactated Ringer's solution) or high fluid treatment ("high" group, 10 mL/kg bolus, 18 mL x kg(-1) x h(-1) lactated Ringer's solution) during colon anastomosis surgery and a subsequent measurement period (4 h). Two-and-half hours after surgery, tissue oxygen tension was recorded for 30 min during ventilation with 30% oxygen. Three hours after surgery, the animals' lungs were ventilated with 100% oxygen for 60 min. Tissue oxygen tension was recorded in the last 30 min. Tissue oxygen tension was measured with polarographic Clark-type electrodes, positioned in healthy colonic wall, close (2 cm) to the anastomosis, and in the anastomosis. RESULTS: In every group, tissue oxygen tension during ventilation with 100% oxygen was approximately twice as high as during ventilation with 30% oxygen, a statistically significant result. High or low volume crystalloid fluid treatment had no effect on colon tissue oxygen tension. CONCLUSIONS: Supplemental oxygen, but not supplemental crystalloid fluid, increased tissue oxygen tension in healthy, perianastomotic, and anastomotic colon tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen-sensitive 3He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO2) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acqiured on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n = 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Oxidative killing is the primary defense against surgical pathogens; risk of infection is inversely related to tissue oxygenation. Subcutaneous tissue oxygenation in obese patients is significantly less than in lean patients during general anesthesia. However, it remains unknown whether reduced intraoperative tissue oxygenation in obese patients results from obesity per se or from a combination of anesthesia and surgery. In a pilot study, we tested the hypothesis that tissue oxygenation is reduced in spontaneously breathing, unanesthetized obese volunteers. METHODS: Seven lean volunteers with a body mass index (BMI) of 22 +/- 2 kg/m(2) were compared to seven volunteers with a BMI of 46 +/- 4 kg/m(2). Volunteers were subjected to the following oxygen challenges: (1) room air; (2) 2 l/min oxygen via nasal prongs, (3) 6 l/min oxygen through a rebreathing face mask; (4) oxygen as needed to achieve an arterial oxygen pressure (arterial pO(2)) of 200 mmHg; and (5) oxygen as needed to achieve an arterial pO(2) of 300 mmHg. The oxygen challenges were randomized. Arterial pO(2) was measured with a continuous intraarterial blood gas analyzer (Paratrend 7); deltoid subcutaneous tissue oxygenation was measured with a polarographic microoxygen sensor (Licox). RESULTS: Subcutaneous tissue oxygenation was similar in lean and obese volunteers: (1) room air, 52 +/- 10 vs 58 +/- 8 mmHg; (2) 2 l/min, 77 +/- 25 vs 79 +/- 24 mmHg; (3) 6 l/min, 125 +/- 43 vs 121 +/- 25 mmHg; (4) arterial pO(2) = 200 mmHg, 115 +/- 42 vs 144 +/- 23 mmHg; (5) arterial pO(2) = 300 mmHg, 145 +/- 41 vs 154 +/- 32 mmHg. CONCLUSION: In this pilot study, we could not identify significant differences in deltoid subcutaneous tissue oxygen pressure between lean and morbidly obese volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. METHODS: In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. RESULTS: Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. CONCLUSIONS: The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical stress response markedly increases sympathetic nerve activity and catecholamine concentrations. This may contribute to peripheral vasoconstriction, reduced wound perfusion and subsequent tissue hypoxia. Opioids are known to depress the hypothalamic-adrenal response to surgery in a dose-dependent manner. We tested the hypothesis that continuous remifentanil administration produces improved subcutaneous tissue oxygen tension compared to fentanyl bolus administration. Forty-six patients undergoing major abdominal surgery were randomly assigned to receive either fentanyl bolus administration or continuous remifentanil infusion. Mean subcutaneous tissue oxygen values over the entire intra-operative period were significantly higher in the remifentanil group, when compared to the fentanyl group: 8 (2) kPa vs 6.7 (1.5) kPa, % CI difference: - 2.3 kPa to - 0.3 kPa, p = 0.013. Continuous intra-operative opioid administration may blunt vasoconstriction caused by surgical stress and adrenergic responses more than an equi-effective anaesthetic regimen based on smaller-dose bolus opioid administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Wound infection remains a common and serious complication after colonic surgery. Although many colonic operations are performed laparoscopically, it remains unclear whether this has any impact on the incidence of wound infection. Subcutaneous tissue oxygenation is an excellent predictor of surgical wound infection. The impact of open and laparoscopic colonic surgery on tissue oxygenation was compared. METHODS: Fifty-two patients undergoing elective open and laparoscopic left-sided colonic resections were evaluated in a prospective observational study. Anaesthesia management was standardized and intraoperative arterial partial pressure of oxygen was kept at 150 mmHg in both groups. Oxygen tension was measured in the subcutaneous tissue of the right upper arm. RESULTS: At the start of surgery subcutaneous tissue oxygen tension (PsqO(2)) was similar in both groups (mean(s.d.) 65.8(17.2) and 63.7(23.6) mmHg for open and laparoscopic operations respectively; P = 0.714). Tissue oxygen remained stable in the open group, but dropped significantly in the laparoscopic group during the course of surgery (PsqO(2) after operation 53.4(12.9) and 45.5(11.6) mmHg, respectively; P = 0.012). CONCLUSION: Laparoscopic colonic surgery significantly decreases PsqO(2), an effect that occurs early in the course of surgery. As tissue oxygen tension is a predictor of wound infection, these results may explain why the risk of wound infection after laparoscopic surgery remains higher than expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine if changes in intrarenal oxygenation during acute unilateral ureteral obstruction can be depicted with blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained from all patients. BOLD MR imaging was performed in 10 male patients (mean age, 45 years +/- 17 [standard deviation]; range, 20-73 years) with a distal unilateral ureteral calculus and in 10 healthy age-matched male volunteers to estimate R2*, which is inversely related to tissue Po(2). R2* values were determined in the cortex and medulla of the obstructed and the contralateral nonobstructed kidneys. To reduce external effects on R2*, the R2* ratio between the medulla and cortex was also analyzed. Statistical analysis was performed with nonparametric rank tests. P < .05 was considered to indicate a significant difference. RESULTS: All patients had significantly lower medullary and cortical R2* values in the obstructed kidney (median R2* in medulla, 10.9 sec(-1) [range, 9.1-14.3 sec(-1)]; median R2* in cortex, 10.4 sec(-1) [range, 9.7-11.3 sec(-1)]) than in the nonobstructed kidney (median R2* in medulla, 17.2 sec(-1) [range, 14.6-23.2 sec(-1)], P = .005; median R2* in cortex, 11.7 sec(-1) [range, 11.0-14.0 sec(-1)], P = .005); values in the obstructed kidneys were also significantly lower than values in the kidneys of healthy control subjects (median R2* in medulla, 16.1 sec(-1) [range, 13.9-18.1 sec(-1)], P < .001; median R2* in cortex, 11.6 sec(-1) [range, 10.5-12.9 sec(-1)], P < .001). R2* ratios in the obstructed kidneys (median, 1.06; range, 0.85-1.27) were significantly lower than those in the nonobstructed kidneys (median, 1.49; range, 1.26-1.71; P = .005) and those in the kidneys of healthy control subjects (median, 1.38; range, 1.23-1.47; P < .001). In contrast, R2* ratios in the nonobstructed kidneys of patients were significantly higher than those in kidneys of healthy control subjects (P = .01). CONCLUSION: Increased oxygen content in the renal cortex and medulla occurs with acute unilateral ureteral obstruction, suggesting reduced function of the affected kidney.