942 resultados para Nonlinear static analysis
Quantitative end qualitative analysis of the electrical activity of rectus abdominis muscle portions
Resumo:
The purpose of this study was to investigate the electrical behavior pattern of the Rectus abdominis muscle by qualitative and quantitative analysis of the electromyographic signal obtained from its superior, medium and inferior portions during dynamic and static activities. Ten voluntaries (aged X = 17.8 years, SD = 1.6) athletic males were studied without history of muscle skeletal disfunction. For the quantitative analysis the RMS (Root Mean Square) values obtained in the electromyographic signal during the isometric exercises were normalized and expressed in maximum voluntary isometric contraction percentages. For the qualitative analysis of the dynamic activity the electromyographic signal was processed by full-wave rectification, linear envelope and normalization (amplitude and time), so that the resulting curve of the processed signal was submitted to descriptive graphic analysis. The results of the quantitative study show that there is not a statistically significant difference among the portions of the muscle. Qualitative analysis demonstrated two aspects: the presence of a common activation electric pattern in the portions of Rectus abdominis muscle and the absence of significant difference in the inclination angles in the electrical activity curve during the isotonic exercises.
Resumo:
Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.
Resumo:
Shape memory alloys (SMAs) provide a compact and effective actuation for a variety of mechanical systems. In this paper, a numerical simulation study of a three degree of-freedom airfoil, subjected to two-dimensional incompressible inviscid flow using a SMA is presented. SMA wire actuators are used to control the flap movement of a wing section. Through the thermo-mechanical constitutive equation of the SMA proposed by Brison, we simulate numerically the behavior of a double SMA wire actuator. Two SMA actuators are used: one to move the flap down and the other to move the flap up. Through the numerical results conducted in the present study, the behavior and characteristics of an SMA actuator with two SMA wires are shown the effectiveness of the SMA actuator. In conclusion, this paper shows the feasibility of using SMA wire actuators for flap movement, with success
Resumo:
Not long ago, most software was written by professional programmers, who could be presumed to have an interest in software engineering methodologies and in tools and techniques for improving software dependability. Today, however, a great deal of software is written not by professionals but by end-users, who create applications such as multimedia simulations, dynamic web pages, and spreadsheets. Applications such as these are often used to guide important decisions or aid in important tasks, and it is important that they be sufficiently dependable, but evidence shows that they frequently are not. For example, studies have shown that a large percentage of the spreadsheets created by end-users contain faults. Despite such evidence, until recently, relatively little research had been done to help end-users create more dependable software. We have been working to address this problem by finding ways to provide at least some of the benefits of formal software engineering techniques to end-user programmers. In this talk, focusing on the spreadsheet application paradigm, I present several of our approaches, focusing on methodologies that utilize source-code-analysis techniques to help end-users build more dependable spreadsheets. Behind the scenes, our methodologies use static analyses such as dataflow analysis and slicing, together with dynamic analyses such as execution monitoring, to support user tasks such as validation and fault localization. I show how, to accommodate the user base of spreadsheet languages, an interface to these methodologies can be provided in a manner that does not require an understanding of the theory behind the analyses, yet supports the interactive, incremental process by which spreadsheets are created. Finally, I present empirical results gathered in the use of our methodologies that highlight several costs and benefits trade-offs, and many opportunities for future work.
Resumo:
Vortex-induced motion (VIM) is a highly nonlinear dynamic phenomenon. Usual spectral analysis methods, using the Fourier transform, rely on the hypotheses of linear and stationary dynamics. A method to treat nonstationary signals that emerge from nonlinear systems is denoted Hilbert-Huang transform (HHT) method. The development of an analysis methodology to study the VIM of a monocolumn production, storage, and offloading system using HHT is presented. The purposes of the present methodology are to improve the statistics analysis of VIM. The results showed to be comparable to results obtained from a traditional analysis (mean of the 10% highest peaks) particularly for the motions in the transverse direction, although the difference between the results from the traditional analysis for the motions in the in-line direction showed a difference of around 25%. The results from the HHT analysis are more reliable than the traditional ones, owing to the larger number of points to calculate the statistics characteristics. These results may be used to design risers and mooring lines, as well as to obtain VIM parameters to calibrate numerical predictions. [DOI: 10.1115/1.4003493]
Resumo:
There are several techniques to characterize the elastic modulus of wood and those currently using the natural frequencies of vibration stand out as they are non-destructive techniques, producing results that can be repeated and compared over time. This study reports on the effectiveness of the testing methods based on the natural frequencies of vibration versus static bending to obtain the elastic properties of reforested structural wood components usually employed in civil construction. The following components were evaluated: 24 beams of Eucalyptus sp. with nominal dimensions (40 x 60 x 2.000 mm) and 14 beams of Pinus oocarpa with nominal dimensions (45 x 90 x 2.300 mm) both without treatment; 30 boards with nominal dimensions (40 x 240 x 2.010 mm) and 30 boards with nominal dimensions (40 x 240 x 3.050 mm), both of Pinus oocarpa and with chromate copper arsenate (CCA) preservative treatment. The results obtained in thiswork show good correlation when compared to the results obtained by the static bending mechanical method, especially when applying the natural frequency of longitudinal vibration. The use of longitudinal frequency was reliable and practical, therefore recommended for determining the modulus of elasticity of wood structural elements. It was also found that no specific support is needed for the specimens using the longitudinal frequency, as well as no previous calibrations, reducing the execution time and enabling to test many samples.
Resumo:
The purpose of this study is to present a position based tetrahedral finite element method of any order to accurately predict the mechanical behavior of solids constituted by functionally graded elastic materials and subjected to large displacements. The application of high-order elements makes it possible to overcome the volumetric and shear locking that appears in usual homogeneous isotropic situations or even in non-homogeneous cases developing small or large displacements. The use of parallel processing to improve the computational efficiency, allows employing high-order elements instead of low-order ones with reduced integration techniques or strain enhancements. The Green-Lagrange strain is adopted and the constitutive relation is the functionally graded Saint Venant-Kirchhoff law. The equilibrium is achieved by the minimum total potential energy principle. Examples of large displacement problems are presented and results confirm the locking free behavior of high-order elements for non-homogeneous materials. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Different representations for a control surface freeplay nonlinearity in a three degree of freedom aeroelastic system are assessed. These are the discontinuous, polynomial and hyperbolic tangent representations. The Duhamel formulation is used to model the aerodynamic loads. Assessment of the validity of these representations is performed through comparison with previous experimental observations. The results show that the instability and nonlinear response characteristics are accurately predicted when using the discontinuous and hyperbolic tangent representations. On the other hand, the polynomial representation fails to predict chaotic motions observed in the experiments. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
PURPOSE. The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment MATERIALS AND METHODS. Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 x 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45 degrees inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS. Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION. Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. [J Adv Prosthodont 2012;4:158-61]
Resumo:
Lemonte and Cordeiro [Birnbaum-Saunders nonlinear regression models, Comput. Stat. Data Anal. 53 (2009), pp. 4441-4452] introduced a class of Birnbaum-Saunders (BS) nonlinear regression models potentially useful in lifetime data analysis. We give a general matrix Bartlett correction formula to improve the likelihood ratio (LR) tests in these models. The formula is simple enough to be used analytically to obtain several closed-form expressions in special cases. Our results generalize those in Lemonte et al. [Improved likelihood inference in Birnbaum-Saunders regressions, Comput. Stat. DataAnal. 54 (2010), pp. 1307-1316], which hold only for the BS linear regression models. We consider Monte Carlo simulations to show that the corrected tests work better than the usual LR tests.
Resumo:
Since the mid 1980s the Atomic Force Microscope is one the most powerful tools to perform surface investigation, and since 1995 Non-Contact AFM achieved true atomic resolution. The Frequency-Modulated Atomic Force Microscope (FM-AFM) operates in the dynamic mode, which means that the control system of the FM-AFM must force the micro-cantilever to oscillate with constant amplitude and frequency. However, tip-sample interaction forces cause modulations in the microcantilever motion. A Phase-Locked loop (PLL) is used to demodulate the tip-sample interaction forces from the microcantilever motion. The demodulated signal is used as the feedback signal to the control system, and to generate both topographic and dissipation images. As a consequence, a proper design of the PLL is vital to the FM-AFM performance. In this work, using bifurcation analysis, the lock-in range of the PLL is determined as a function of the frequency shift (Q) of the microcantilever and of the other design parameters, providing a technique to properly design the PLL in the FM-AFM system. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Objectives: Cardiac surgery (CC) determines systemic and pulmonary changes that require special care. What motivated several studies conducted in healthy subjects to assess muscle strength were the awareness of the importance of respiratory muscle dysfunction in the development of respiratory failure. These studies used maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) values. This study examined the concordance between the values predicted by the equations proposed by Black & Hyatt and Neder, and the measured values in cardiac surgery (CS) patients. Methods: Data were collected from preoperative evaluation forms. The Lin coefficient and Bland-Altman plots were used for statistical concordance analysis. The multiple linear regression and analysis of variance (ANOVA) were used to produce new formulas. Results: There were weak correlations of 0.22 and 0.19 in the MIP analysis and of 0.10 and 0.32 in the MEP analysis, for the formulas of Black & Hyatt and Neder, respectively. The ANOVA for both MIP and MEP were significant (P <0.0001), and the following formulas were developed: MIP = 88.82 - (0.51 x age) + (19.86 x gender), and MEP = 91.36 -(030 x age) + (29.92 x gender). Conclusions: The Black and Hyatt and Neder formulas predict highly discrepant values of MIP and MEP and should not be used to identify muscle weakness in CS patients.
Resumo:
The strain image contrast of some in vivo breast lesions changes with increasing applied load. This change is attributed to differences in the nonlinear elastic properties of the constituent tissues suggesting some potential to help classify breast diseases by their nonlinear elastic properties. A phantom with inclusions and long-term stability is desired to serve as a test bed for nonlinear elasticity imaging method development, testing, etc. This study reports a phantom designed to investigate nonlinear elastic properties with ultrasound elastographic techniques. The phantom contains four spherical inclusions and was manufactured from a mixture of gelatin, agar and oil. The phantom background and each of the inclusions have distinct Young's modulus and nonlinear mechanical behavior. This phantom was subjected to large deformations (up to 20%) while scanning with ultrasound, and changes in strain image contrast and contrast-to-noise ratio between inclusion and background, as a function of applied deformation, were investigated. The changes in contrast over a large deformation range predicted by the finite element analysis (FEA) were consistent with those experimentally observed. Therefore, the paper reports a procedure for making phantoms with predictable nonlinear behavior, based on independent measurements of the constituent materials, and shows that the resulting strain images (e. g., strain contrast) agree with that predicted with nonlinear FEA.
Resumo:
The extraction of information about neural activity timing from BOLD signal is a challenging task as the shape of the BOLD curve does not directly reflect the temporal characteristics of electrical activity of neurons. In this work, we introduce the concept of neural processing time (NPT) as a parameter of the biophysical model of the hemodynamic response function (HRF). Through this new concept we aim to infer more accurately the duration of neuronal response from the highly nonlinear BOLD effect. The face validity and applicability of the concept of NPT are evaluated through simulations and analysis of experimental time series. The results of both simulation and application were compared with summary measures of HRF shape. The experiment that was analyzed consisted of a decision-making paradigm with simultaneous emotional distracters. We hypothesize that the NPT in primary sensory areas, like the fusiform gyrus, is approximately the stimulus presentation duration. On the other hand, in areas related to processing of an emotional distracter, the NPT should depend on the experimental condition. As predicted, the NPT in fusiform gyrus is close to the stimulus duration and the NPT in dorsal anterior cingulate gyrus depends on the presence of an emotional distracter. Interestingly, the NPT in right but not left dorsal lateral prefrontal cortex depends on the stimulus emotional content. The summary measures of HRF obtained by a standard approach did not detect the variations observed in the NPT. Hum Brain Mapp, 2012. (C) 2010 Wiley Periodicals, Inc.
Resumo:
Background: Specific research tools and designs can assist in identifying the efficiency of physical activity in elderly women. Objectives: To identify the effects of physical activity on the physical condition of older women. Method: A one-year-long physical activity program (123 sessions) was implemented for women aged 60 years or older. Four physical assessments were conducted, in which weight, height, BMI, blood pressure, heart rate, absences, grip strength, flexibility, VO2max, and static and dynamic balance were assessed. The statistical analyses included a repeated measures analysis, both inferential (analysis of variance - ANOVA) and effect size (Cohen's d coefficient), as well as identification of the participants' efficiency (Data Envelopment Analysis - DEA). Results: Despite the observation of differences that depended on the analysis used, the results were successful in the sense that they showed that physical activity adapted to older women can effectively change the decline in physical ability associated with aging, depending on the purpose of the study. The 60-65 yrs group was the most capable of converting physical activity into health benefits in both the short and long term. The >65 yrs group took less advantage of physical activity. Conclusions: Adherence to the program and actual time spent on each type of exercise are the factors that determine which population can benefit from physical activity programs. The DEA allows the assessment of the results related to time spent on physical activity in terms of health concerns. Article registered in Clinicaltrials.gov under number NCT01558401.