943 resultados para Microneedle electrodes
Resumo:
This paper reviews the catalytic and electrocatalytic oxidation of organic compounds using cerium (IV) salts. Direct and indirect methods and those using modified electrodes are described.
Resumo:
The combination of cyclic voltammetry and on line mass spectrometry, called differential electrochemical mass spectrometry (DEMS), is already a well established method for on line identification and quantitative detection of the products and intermediates of electrochemical reactions. This article aims to show the principles of the method and how this technique have been used to study electrochemical problems such the electrocatalytic oxidation of organic molecules, as methanol and ethanol, at noble metal electrodes.
Resumo:
This paper is designed to divulge some tests found in books, articles and international technical standards, by means of which it is possible to evaluate the performance of reference electrode widely used in potentiometric and voltammetric methods. The reference potential (Eref), junction resistance (Rj), the ability of keeping up the potential when current is flowing (polarizability), and of generating junction potentials (Ej) are applied to some commercial electrodes. The results obtained are amply discussed and some corrective procedures are suggested when the electrode fails.
Resumo:
A study of the kinetics of oxygen evolution in alkaline conditions from ceramic films of Mn2O3 supported on stainless steel was carried out. This study has been done through the determination of transfer coefficients, Tafel slopes and exchange currents using potentiodynamic and quasi-potentiostatic measurements. The activation energy was determined as a function of the overpotential and, additionally, the electrode active surface was estimated. The results are consistent with data already published for other electrodes, implying that the methods used in this work were reliable and precise.
Resumo:
The field of flow injection potentiometry (FIP) is reviewed and its current status assessed. The research development and application of electrodes in flow injection systems are presented and discussed.
Resumo:
It has been carried out an investigation of ethanol electro-oxidation on Ti/IrO2 electrodes. The experimental results show a high selectivity towards acetaldehyde formation thus, offering potential advantages in cost and availability of raw material. It has been observed that the electrode is partially blocked by a film formed after the oxidation of the starting material which can be removed by pulse technique between RDO and RDH onset. The mechanism and the selectivity of the product formed is presented.
Resumo:
Chemically modified electrodes based on hexacyanometalate films are presented as a tool in analytical chemistry. Use of amperometric sensors and/or biosensors based on the metal-hexacyanoferrate films is a tendency. This article reviews some applications of these films for analytical determination of both inorganic (e.g. As3+, S2O3(2-)) and organic (e.g. cysteine, hydrazine, ascorbic acid, gluthatione, glucose, etc.) compounds.
Resumo:
Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).
Resumo:
Platinum is widely used as electrode in electrocatalytic processes, however the use of polycrystalline electrodes introduces a series of variables in the electrochemical system due to the aleatory contribution of all the crystallographic orientations with different surface packing of atoms. Single crystal platinum electrodes of low Miller index present surface structure of high regularity and serve as model to establish a correlation among the macroscopic and microscopic properties of the electrochemical interface. Therefore, the main aim of this work is the study of the voltammetric profiles of the reversible adsorption-desorption of hydrogen on Pt(100), Pt(110) and Pt(111), in order to correlate the electrochemical properties of each different orientation with the surface atomic structure.
Resumo:
Macroscopic samples of fullerene nanostructures are obtained in a modified arc furnace using the electric arc method with a Helium atmosphere at low pressures. High purity graphite rods are used as electrodes but, when drilled and the orifices filled with powders of transition metals (Fe, Co, Ni) acting as catalysts, the resulting particles are carbon nanostructures of the fullerene family, known as Single Wall Nanotubes (SWNTs). They have typical diameters of 1.4 nm, lengths up to tenths of microns and they are arranged together in bundles containing several SWNTs. Those samples are observed and analyzed using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM) techniques.
Resumo:
The most relevant advances on the analytical applications of chemically modified electrodes (CME) are presented. CME have received great attention due to the possibility of electrode surface modification including chemisorption, composite generation and polymer coating. In recent years, the interest in CME has increased overall to improve the sensitivity and selectivity of the electroanalytical probes, considering the electron mediator incorporation and the new conducting polymers development. The general procedures employed for the electrode modification and the operational characteristics of some electrochemical sensors are discussed.
Resumo:
UNS S31254 SS electrodes have been built to substitute platinum in conductimetric titrations. The electrodes were tested in both acid-basic titration (chloridric acid and sodium hydroxide) and precipitation titration (sodium chloride and argentum nitrate as titrant). The practical application was exemplified from conductimetric tritations of HF ¾ HNO3 mixtures used in metalurgical industry to passivate stainless steels. The results were compared with those obtained using commercial platinum electrodes. The equivalent volumes obtained were comparable within 3% experimental error. Its application depends on the nature of electrolyte. These results have shown that stainless steel, less expensive than platinum (about three order of magnitude), can substitute platinum electrodes in routine analyses and didactic laboratories.
Resumo:
This review focuses the development of electrochemical detection systems coupled to capillary electrophoresis. Conductometric, amperometric, voltametric, and potentiometric modes of detection are reviewed. The positioning of the electrodes, interferences of high electric field, and the materials employed in the fabrication and modification of the electrodes are discussed. The advantages of the use of electrochemical detection with capillary electrophoresis, regarding to the sensitivity and selectivity, is exemplified with a large number of applications. Also, the use of electrochemical detection systems in microchip technology is addressed.
Resumo:
Self-assembled monolayers (SAMs) modified electrodes exhibit unique behavior that can greatly benefit electrochemical sensing. This brief review highlights the applications of SAM modified electrodes in electroanalytical chemistry. After a general introduction, which includes the approaches for SAM development, different electrochemical systems for detecting inorganic and organic species are described and discussed. Special attention to the coupling of biological sensing element to the SAM is given, which can selectively recognize the analyte. Future prospects are also evaluated.
Resumo:
Large Hadron Collider (LHC) is the main particle accelerator at CERN. LHC is created with main goal to search elementary particles and help science investigate our universe. Radiation in LHC is caused by charged particles circular acceleration, therefore detectors tracing particles in existed severe conditions during the experiments must be radiation tolerant. Moreover, further upgrade of luminosity (up to 1035 cm-2s-1) requires development of particle detector’s structure. This work is dedicated to show the new type 3D stripixel detector with serious structural improvement. The new type of radiation-hard detector has a three-dimensional (3D) array of the p+ and n+ electrodes that penetrate into the detector bulk. The electrons and holes are then collected at oppositely biased electrodes. Proposed 3D stripixel detector demonstrates that full depletion voltage is lower that that for planar detectors. Low depletion voltage is one of the main advantages because only depleted part of the device is active are. Because of small spacing between electrodes, charge collection distances are smaller which results in high speed of the detector’s response. In this work is also briefly discussed dual-column type detectors, meaning consisting both n+ and p+ type columnar electrodes in its structure, and was declared that dual-column detectors show better electric filed distribution then single sided radiation detectors. The dead space or in other words low electric field region in significantly suppressed. Simulations were carried out by using Atlas device simulation software. As a simulation results in this work are represented the electric field distribution under different bias voltages.