923 resultados para Maxillofacial prosthesis implantation
Resumo:
OBJECTIVES: This study was designed to compare coronary collateral function in patients after bare-metal stent (BMS) or drug-eluting stent (DES) implantation. BACKGROUND: Drug-eluting stents have an inhibitory effect on the production of cytokines, chemotactic proteins, and growth factors, and may therefore negatively affect coronary collateral growth. METHODS: A total of 120 patients with long-term stable coronary artery disease (CAD) after stent implantation were included. Both the BMS group and the DES group comprised 60 patients matched for in-stent stenosis severity of the vessel undergoing collateral flow index (CFI) measurement at follow-up and for the duration of follow-up. The primary end point of the investigation was invasively determined coronary collateral function 6 months after stent implantation. Collateral function was assessed by simultaneous aortic, coronary wedge, and central venous pressure measurements (yielding CFI) and by intracoronary electrocardiogram during balloon occlusion. RESULTS: There were no differences between the groups regarding age, gender, body mass index, frequency of cardiovascular risk factors, use of cardiovascular drugs, severity of CAD, or site of coronary artery stenoses. Despite equal in-stent stenosis severity (46 +/- 34% and 45 +/- 36%) and equal follow-up duration (6.2 +/- 10 months and 6.5 +/- 5.4 months), CFI was diminished in the DES versus BMS group (0.154 +/- 0.097 vs. 0.224 +/- 0.142; p = 0.0049), and the rate of collaterals insufficient to prevent ischemia during occlusion (intracoronary electrocardiographic ST-segment elevation > or =0.1 mV) was higher with 50 of 60 patients in the DES group and 33 of 60 patients in the BMS group (p = 0.001). CONCLUSIONS: Collateral function long after coronary stenting is impaired with DES (sirolimus and paclitaxel) when compared with BMS. Considering the protective nature of collateral vessels, this could lead to more serious cardiac events in the presence of an abrupt coronary occlusion.
Resumo:
Seromas occurring around a vascular graft are a rare complication. We report a life-threatening plasma leakage that occurred through the polytetrafluoroethylene vascular prosthesis of an Impella right ventricular assist device (Impella RD [Impella Cardiosystems GmbH, Aachen, Germany]) implanted in a 62-year-old patient with acute right ventricular failure after cardiac transplantation. The leakage became progressively massive. Weaning the patient from the right ventricular assist device was not possible. The prosthesis was thus wrapped within a pericardial patch to contain the leakage. Three days later the patient could be successfully weaned and the pump was removed. The clinical evolution was favorable.
Resumo:
OBJECTIVE: To compare four different implantation modalities for the repair of superficial osteochondral defects in a caprine model using autologous, scaffold-free, engineered cartilage constructs, and to describe the short-term outcome of successfully implanted constructs. METHODS: Scaffold-free, autologous cartilage constructs were implanted within superficial osteochondral defects created in the stifle joints of nine adult goats. The implants were distributed between four 6-mm-diameter superficial osteochondral defects created in the trochlea femoris and secured in the defect using a covering periosteal flap (PF) alone or in combination with adhesives (platelet-rich plasma (PRP) or fibrin), or using PRP alone. Eight weeks after implantation surgery, the animals were killed. The defect sites were excised and subjected to macroscopic and histopathologic analyses. RESULTS: At 8 weeks, implants that had been held in place exclusively with a PF were well integrated both laterally and basally. The repair tissue manifested an architecture similar to that of hyaline articular cartilage. However, most of the implants that had been glued in place in the absence of a PF were lost during the initial 4-week phase of restricted joint movement. The use of human fibrin glue (FG) led to massive cell infiltration of the subchondral bone. CONCLUSIONS: The implantation of autologous, scaffold-free, engineered cartilage constructs might best be performed beneath a PF without the use of tissue adhesives. Successfully implanted constructs showed hyaline-like characteristics in adult goats within 2 months. Long-term animal studies and pilot clinical trials are now needed to evaluate the efficacy of this treatment strategy.
Resumo:
PURPOSE: The aim of this study was to determine occupational facial fractures in central Switzerland. Concomitant injuries were also studied. MATERIALS AND METHODS: The Department of Cranio-Maxillofacial Surgery at the University Hospital in Berne provides a 24-hour maxillofacial trauma service for its population (1.6 million). The present study was comprised of 42 patients (8.4% of treated maxillofacial injuries) with occupational maxillofacial fractures registered at this unit between 2000 and 2002. Information on the topic of occupation, the cause of the accidents, and the topographic location of the fractures was analyzed. RESULTS: The mean age of the patients was 44.4 years, with a male to female ratio of 41:1. Sixty-nine percent of the injuries occurred in farm and forestry workers and in construction laborers during the summertime (33%). Workers in these occupations carried a 127-fold (farm and forestry workers) and a 44-fold (construction laborers) higher risk of incurring maxillofacial fractures than did service and office workers. Injuries were most frequently (43%) caused by a thrown, projected, or falling object. Eighty-two percent of the fractures occurred in the midface region and at the skull base. Fifty-nine percent of the patients had concomitant injuries. In 69%, surgery was necessary, the mean duration of their hospital stay being 4.8 days. CONCLUSION: The probability of sustaining work-related maxillofacial traumata is correlated to the nature of the occupation. Farm and forestry workers are at the highest risk, most frequently injured by being struck by an object or an animal. The introduction of personalized safety measures should become obligatory in high-risk occupations.
Resumo:
In the last years life duration of shoulder prostheses could be prolonged through improvement of prosthesis quality, instrumentation and surgical techniques. After shoulder total arthroplasty, the patients show signifi cant reduction of pain and good functional mid and long term results. Indication to shoulder arthroplasty can be made by even younger and sportive active patients. Many sport activities remain possible after implantation of a shoulder prosthesis. A systematic rehabilitation is mandatory to yield optimal functional results. Intensity of sports activities should remain in relation with the preoperative status. Activities with total contact and high impaction strength should be avoided to extend the duration of life of the prosthesis.
Resumo:
Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement into the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.
A systematic review of prophylactic antibiotics in the surgical treatment of maxillofacial fractures
Resumo:
PURPOSE: A systematic review was performed to find evidence for prophylactic administration of antibiotics in relation to treatment of maxillofacial fractures. METHODS: Four studies were retrieved that fulfilled most of the requirements of being randomized controlled clinical trials. RESULTS: An analysis of these studies showed a 3-fold decrease in the infection rate of mandibular fractures in the antibiotic treated groups compared with the control groups. A variety of antibiotics had been used with an apparently uniform effect. A "1-shot" regimen or a 1-day treatment course had a similar or perhaps even better effect than 7 days of treatment. No infections were related to condylar, maxillary, or zygoma fractures. CONCLUSION: A 1-shot or 1-day administration of prophylactic antibiotics seem to be the best documented to reduce infections in the management of mandibular fractures not involving the condylar region.
Resumo:
OBJECTIVES: We assessed the impact of vessel size on angiographic and long-term clinical outcome after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) within a randomized trial (SIRTAX [Sirolimus-Eluting Stent Compared With Paclitaxel-Eluting Stent for Coronary Revascularization]). BACKGROUND: Percutaneous coronary intervention in small-vessel disease is associated with an increased risk of major adverse cardiac events (MACE). METHODS: A total of 1,012 patients were randomly assigned to treatment with SES (n = 503) or PES (n = 509). A stratified analysis of angiographic and clinical outcome was performed up to 2 years after PCI according to size of the treated vessel (reference vessel diameter < or =2.75 vs. >2.75 mm). RESULTS: Of 1,012 patients, 370 patients (37%) with 495 lesions underwent stent implantation in small vessels only, 504 patients (50%) with 613 lesions in large vessels only, and 138 patients (14%) with 301 lesions in both small and large vessels (mixed). In patients with small-vessel stents, SES reduced MACE by 55% (10.4% vs. 21.4%; p = 0.004), mainly driven by a 69% reduction of target lesion revascularization (TLR) (6.0% vs. 17.7%; p = 0.001) compared with PES at 2 years. In patients with large- and mixed-vessel stents, rates of MACE (large: 10.4% vs. 13.1%; p = 0.33; mixed: 16.7% vs. 18.0%; p = 0.83) and TLR (large: 6.9% vs. 8.6%; p = 0.47; mixed: 16.7% vs. 15.4%; p = 0.86) were similar for SES and PES. There were no significant differences with respect to death and myocardial infarction between the 3 groups. CONCLUSIONS: Compared with PES, SES more effectively reduced MACE and TLR in small-vessel disease. Differences between SES and PES appear less pronounced in patients with large- and mixed-vessel disease. (The SIRTAX trial; http://clinicaltrials.gov/ct/show/NCT00297661?order=1; NCT00297661).
Resumo:
BACKGROUND: The aim of this study was to investigate the biochemical properties, histological and immunohistochemical appearance, and magnetic resonance (MR) imaging findings of reparative cartilage after autologous chondrocyte implantation (ACI) for osteochondritis dissecans (OCD). METHODS: Six patients (mean age 20.2 +/- 8.8 years; 13-35 years) who underwent ACI for full-thickness cartilage defects of the femoral condyle were studied. One year after the procedure, a second-look arthroscopic operation was performed with biopsy of reparative tissue. The International Cartilage Repair Society (ICRS) visual histological assessment scale was used for histological assessment. Biopsied tissue was immunohistochemically analyzed with the use of monoclonal antihuman collagen type I and monoclonal antihuman collagen type II primary antibodies. Glycosaminoglycan (GAG) concentrations in biopsied reparative cartilage samples were measured by high performance liquid chromatography (HPLC). MR imaging was performed with T1- and T2-weighted imaging and three-dimensional spoiled gradient-recalled (3D-SPGR) MR imaging. RESULTS: Four tissue samples were graded as having a mixed morphology of hyaline and fibrocartilage while the other two were graded as fibrocartilage. Average ICRS scores for each criterion were (I) 1.0 +/- 1.5; (II) 1.7 +/- 0.5; (III) 0.6 +/- 1.0; (IV) 3.0 +/- 0.0; (V) 1.8 +/- 1.5; and (VI) 2.5 +/- 1.2. Average total score was 10.7 +/- 2.8. On immunohistochemical analysis, the matrix from deep and middle layers of reparative cartilage stained positive for type II collagen; however, the surface layer did not stain well. The average GAG concentration in reparative cartilage was 76.6 +/- 4.2 microg/mg whereas that in normal cartilage was 108 +/- 11.2 microg/mg. Common complications observed on 3D-SPGR MR imaging were hypertrophy of grafted periosteum, edema-like signal in bone marrow, and incomplete repair of subchondral bone at the surgical site. Clinically, patients had significant improvements in Lysholm scores. CONCLUSIONS: In spite of a good clinical course, reparative cartilage after ACI had less GAG concentration and was inferior to healthy hyaline cartilage in histological and immunohistochemical appearance and on MRI findings.
Resumo:
Mesenchymal stem cells (MSCs) provide an important source of pluripotent cells for musculoskeletal tissue repair. This study examined the impact of MSC implantation on cartilage healing characteristics in a large animal model. Twelve full-thickness 15-mm cartilage lesions in the femoropatellar articulations of six young mature horses were repaired by injection of a self-polymerizing autogenous fibrin vehicle containing mesenchymal stem cells, or autogenous fibrin alone in control joints. Arthroscopic second look and defect biopsy was obtained at 30 days, and all animals were euthanized 8 months after repair. Cartilage repair tissue and surrounding cartilage were assessed by histology, histochemistry, collagen type I and type II immunohistochemistry, collagen type II in situ hybridization, and matrix biochemical assays. Arthroscopic scores for MSC-implanted defects were significantly improved at the 30-day arthroscopic assessment. Biopsy showed MSC-implanted defects contained increased fibrous tissue with several defects containing predominantly type II collagen. Long-term assessment revealed repair tissue filled grafted and control lesions at 8 months, with no significant difference between stem cell-treated and control defects. Collagen type II and proteoglycan content in MSC-implanted and control defects were similar. Mesenchymal stem cell grafts improved the early healing response, but did not significantly enhance the long-term histologic appearance or biochemical composition of full-thickness cartilage lesions.
Resumo:
BACKGROUND: Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS: Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for > or = 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630+/-166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9+/-16.0 versus 13.3+/-7.9 mm; P<0.001) and stents (34.6+/-22.4 versus 18.6+/-9.5 mm; P<0.001), more stents per lesion (1.6+/-0.9 versus 1.1+/-0.4; P<0.001), and stent overlap (39% versus 8%; P<0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9+/-6.9 versus 20.4+/-7.2 mm2; P=0.46) but significantly larger for the in-stent segment (28.6+/-11.9 versus 20.1+/-6.7 mm2; P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P<0.001) and maximal incomplete stent apposition area was larger (8.3+/-7.5 versus 4.0+/-3.8 mm2; P=0.03) in patients with very late stent thrombosis compared with controls. CONCLUSIONS: Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.