969 resultados para Mantle Convection
Resumo:
Severe local storms, including tornadoes, damaging hail and wind gusts, frequently occur over the eastern and northeastern states of India during the pre-monsoon season (March-May). Forecasting thunderstorms is one of the most difficult tasks in weather prediction, due to their rather small spatial and temporal extension and the inherent non-linearity of their dynamics and physics. In this paper, sensitivity experiments are conducted with the WRF-NMM model to test the impact of convective parameterization schemes on simulating severe thunderstorms that occurred over Kolkata on 20 May 2006 and 21 May 2007 and validated the model results with observation. In addition, a simulation without convective parameterization scheme was performed for each case to determine if the model could simulate the convection explicitly. A statistical analysis based on mean absolute error, root mean square error and correlation coefficient is performed for comparisons between the simulated and observed data with different convective schemes. This study shows that the prediction of thunderstorm affected parameters is sensitive to convective schemes. The Grell-Devenyi cloud ensemble convective scheme is well simulated the thunderstorm activities in terms of time, intensity and the region of occurrence of the events as compared to other convective schemes and also explicit scheme
Resumo:
Die in dieser Arbeit durchgeführten Untersuchungen zeigen, daß es möglich ist, komplexe thermische Systeme, unter Verwendung der thermisch-, elektrischen Analogien, mit PSpice zu simulieren. Im Mittelpunkt der Untersuchungen standen hierbei Strangkühlkörper zur Kühlung von elektronischen Bauelementen. Es konnte gezeigt werden,daß alle Wärmeübertragungsarten, (Wärmeleitung, Konvektion und Wärmestrahlung) in der Simulation berücksichtigt werden können. Für die Berechnung der Konvektion wurden verschiedene Methoden hergeleitet. Diese gelten zum einen für verschiedene Kühlkörpergeometrien, wie z.B. ebene Flächen und Kühlrippenzwischenräume, andererseits unterscheiden sie sich, je nachdem, ob freie oder erzwungene Konvektion betrachtet wird. Für die Wärmestrahlung zwischen den Kühlrippen wurden verschiedenen Berechnungsmethoden entwickelt. Für die Simulation mit PSpice wurde die Berechnung der Wärmestrahlung zwischen den Kühlrippen vereinfacht. Es konnte gezeigt werden, daß die Fehler, die durch die Vereinfachung entstehen, vernachlässigbar klein sind. Für das thermische Verhalten einer zu kühlenden Wärmequelle wurde ein allgemeines Modell entworfen. Zur Bestimmung der Modellparameter wurden verschiedene Meßverfahren entwickelt. Für eine im Fachgebiet Elektromechanik entwickelte Wärmequelle zum Test von Kühlvorrichtungen wurde mit Hilfe dieser Meßverfahren eine Parameterbestimmung durchgeführt. Die Erstellung des thermischen Modells eines Kühlkörpers für die Simulation in PSpice erfordert die Analyse der Kühlkörpergeometrie. Damit diese Analyse weitestgehend automatisiert werden kann, wurden verschiedene Algorithmen unter Matlab entwickelt. Es wurde ein Algorithmus entwickelt, der es ermöglicht, den Kühlkörper in Elementarzellen zu zerlegen, die für die Erstellung des Simulationsmodells benötigt werden. Desweiteren ist es für die Simulation notwendig zu wissen, welche der Elementarzellen am Rand des Kühlkörpers liegen, welche der Elementarzellen an einem Kühlrippenzwischenraum liegen und welche Kühlkörperkanten schräg verlaufen. Auch zur Lösung dieser Aufgaben wurden verschiedene Algorithmen entwickelt. Diese Algorithmen wurden zu einem Programm zusammengefaßt, das es gestattet, unterschiedliche Strangkühlkörper zu simulieren und die Simulationsergebnisse in Form der Temperaturverteilung auf der Montagefläche des Kühlkörpers grafisch darzustellen. Es können stationäre und transiente Simulationen durchgeführt werden. Desweiteren kann der thermische Widerstand des Kühlkörpers RthK als Funktion der Verlustleistung der Wärmequelle dargestellt werden. Zur Verifikation der Simulationsergebnisse wurden Temperaturmessungen an Kühlkörpern durchgeführt und mit den Simulationsergebnissen verglichen. Diese Vergleiche zeigen, daß die Abweichungen im Bereich der Streuung der Temperaturmessung liegen. Das hier entwickelte Verfahren zur thermischen Simulation von Strangkühlkörpern kann somit als gut bewertet werden.
Resumo:
In dieser Arbeit werden nichtüberlappende Gebietszerlegungsmethoden einerseits hinsichtlich der zu lösenden Problemklassen verallgemeinert und andererseits in bisher nicht untersuchten Kontexten betrachtet. Dabei stehen funktionalanalytische Untersuchungen zur Wohldefiniertheit, eindeutigen Lösbarkeit und Konvergenz im Vordergrund. Im ersten Teil werden lineare elliptische Dirichlet-Randwertprobleme behandelt, wobei neben Problemen mit dominantem Hauptteil auch solche mit singulärer Störung desselben, wie konvektions- oder reaktionsdominante Probleme zugelassen sind. Der zweite Teil befasst sich mit (gleichmäßig) monotonen koerziven quasilinearen elliptischen Dirichlet-Randwertproblemen. In beiden Fällen wird das Lipschitz-Gebiet in endlich viele Lipschitz-Teilgebiete zerlegt, wobei insbesondere Kreuzungspunkte und Teilgebiete ohne Außenrand zugelassen sind. Anschließend werden Transmissionsprobleme mit frei wählbaren $L^{\infty}$-Parameterfunktionen hergeleitet, wobei die Konormalenableitungen als Funktionale auf geeigneten Funktionenräumen über den Teilrändern ($H_{00}^{1/2}(\Gamma)$) interpretiert werden. Die iterative Lösung dieser Transmissionsprobleme mit einem Ansatz von Deng führt auf eine Substrukturierungsmethode mit Robin-artigen Transmissionsbedingungen, bei der eine Auswertung der Konormalenableitungen aufgrund einer geschickten Aufdatierung der Robin-Daten nicht notwendig ist (insbesondere ist die bekannte Robin-Robin-Methode von Lions als Spezialfall enthalten). Die Konvergenz bezüglich einer partitionierten $H^1$-Norm wird für beide Problemklassen gezeigt. Dabei werden keine über $H^1$ hinausgehende Regularitätsforderungen an die Lösungen gestellt und die Gebiete müssen keine zusätzlichen Glattheitsvoraussetzungen erfüllen. Im letzten Kapitel werden nichtmonotone koerzive quasilineare Probleme untersucht, wobei das Zugrunde liegende Gebiet nur in zwei Lipschitz-Teilgebiete zerlegt sein soll. Das zugehörige nichtlineare Transmissionsproblem wird durch Kirchhoff-Transformation in lineare Teilprobleme mit nichtlinearen Kopplungsbedingungen überführt. Ein optimierungsbasierter Lösungsansatz, welcher einen geeigneten Abstand der rücktransformierten Dirichlet-Daten der linearen Teilprobleme auf den Teilrändern minimiert, führt auf ein optimales Kontrollproblem. Die dabei entstehenden regularisierten freien Minimierungsprobleme werden mit Hilfe eines Gradientenverfahrens unter minimalen Glattheitsforderungen an die Nichtlinearitäten gelöst. Unter zusätzlichen Glattheitsvoraussetzungen an die Nichtlinearitäten und weiteren technischen Voraussetzungen an die Lösung des quasilinearen Ausgangsproblems, kann zudem die quadratische Konvergenz des Newton-Verfahrens gesichert werden.
Resumo:
Die Konvektionstrocknung ist eine der ältesten Methoden zur Konservierung von Lebensmitteln. Es ist bekannt, dass Agrarprodukte temperaturempfindlich sind. Bei Überhitzung erleiden sie chemische und physikalische Veränderungen, die ihre Qualität vermindern. In der industriellen Praxis wird die Konvektionstrocknung in der Regel auf Grundlage empirisch ermittelter Werte durchgeführt, welche die Produkttemperatur nicht berücksichtigen. Es ist deshalb nicht sichergestellt, ob der Prozess optimal oder auch nur gut betrieben wird. Inhalt dieser Arbeit ist ein Vergleich der klassischen einstufigen Konvektionstrocknung mit einer Prozessführungsstrategie bei der die Produkttemperatur als Regelgröße eingeführt wird. Anhand der Untersuchung des Trocknungsverhaltens von Äpfeln werden die beiden Verfahren analysiert, die erhaltenen Ergebnisse miteinander verglichen und daraus optimierte Trocknungsbedingungen abgeleitet. Die für dieses Projekt entwickelte Prozessanlage erlaubt die simultane Untersuchung sämtlicher wesentlicher Temperaturen, der Gewichtsveränderung und der optischen Qualitätskriterien. Gleichzeitig ist es möglich, entweder die Lufttemperatur oder die Temperatur des Produktes zur regeln, während die jeweils andere Größe als Messwert erfasst wird. Es kann weiterhin zwischen Durch- und Überströmung gewählt werden.
Resumo:
The main task of this work has been to investigate the effects of anisotropy onto the propagation of seismic waves along the Upper Mantle below Germany and adjacent areas. Refraction- and reflexion seismic experiments proved the existence of Upper Mantle anisotropy and its influence onto the propagation of Pn-waves. By the 3D tomographic investigations that have been done here for the crust and the upper mantle, considering the influence of anisotropy, a gap for the investigations in Europe has been closed. These investigations have been done with the SSH-Inversionprogram of Prof. Dr. M. Koch, which is able to compute simultaneously the seismic structure and hypocenters. For the investigation, a dataset has been available with recordings between the years 1975 to 2003 with a total of 60249 P- and 54212 S-phase records of 10028 seismic events. At the beginning, a precise analysis of the residuals (RES, the difference between calculated and observed arrivaltime) has been done which confirmed the existence of anisotropy for Pn-phases. The recognized sinusoidal distribution has been compensated by an extension of the SSH-program by an ellipse with a slow and rectangular fast axis with azimuth to correct the Pn-velocities. The azimuth of the fast axis has been fixed by the application of the simultaneous inversion at 25° - 27° with a variation of the velocities at +- 2.5 about an average value at 8 km/s. This new value differs from the old one at 35°, recognized in the initial residual analysis. This depends on the new computed hypocenters together with the structure. The application of the elliptical correction has resulted in a better fit of the vertical layered 1D-Model, compared to the results of preceding seismological experiments and 1D and 2D investigations. The optimal result of the 1D-inversion has been used as initial starting model for the 3D-inversions to compute the three dimensional picture of the seismic structure of the Crust and Upper Mantle. The simultaneous inversion has showed an optimization of the relocalization of the hypocenters and the reconstruction of the seismic structure in comparison to the geology and tectonic, as described by other investigations. The investigations for the seismic structure and the relocalization have been confirmed by several different tests. First, synthetic traveltime data are computed with an anisotropic variation and inverted with and without anisotropic correction. Further, tests with randomly disturbed hypocenters and traveltime data have been proceeded to verify the influence of the initial values onto the relocalization accuracy and onto the seismic structure and to test for a further improvement by the application of the anisotropic correction. Finally, the results of the work have been applied onto the Waldkirch earthquake in 2004 to compare the isotropic and the anisotropic relocalization with the initial optimal one to verify whether there is some improvement.
Resumo:
Three different drying methods, a forced convection double-pass solar drier (DPSD), typical cabinet type natural convection solar drier (CD) and traditional open-sun drying (OSD) were used for draying of bamboo shoots in central Vietnam. During drying the operational parameters such as drying temperature, relative humidity, air velocity, insolation and water evaporation have been recorded hourly. The mean drying temperatures and relative humidity in the drying chamber were 55.2°C, 23.7%; 47.5°C, 37,6%; 36.2°C, 47.8% in DPSD, CD and OSD, respectively. The mean global radiation during all experimental runs was 670 Wm^−2. The result also shows that fastest drying process was occurred in DPSD where the falling-rate period was achieved after 7 hours, in change to OSD where it took 16 hours. The overall drying efficiency was 23.11%, 15.83% and 9.73% in case of DPSD, CD and OSD, respectively. Although the construction cost of DPSD was significantly higher than in CD, the drying costs per one kilogram of bamboo shoots were by 42.8% lower in case of DPSD as compared to CD. Double-pass solar drier was found to be technically and economically suitable for drying of bamboo shoots under the specific conditions in central Vietnam and in all cases, the use of this drier led to considerable reduction in drying time in comparison to traditional open-sun drying.
Resumo:
One of the most prominent industrial applications of heat transfer science and engineering has been electronics thermal control. Driven by the relentless increase in spatial density of microelectronic devices, integrated circuit chip powers have risen by a factor of 100 over the past twenty years, with a somewhat smaller increase in heat flux. The traditional approaches using natural convection and forced-air cooling are becoming less viable as power levels increase. This paper provides a high-level overview of the thermal management problem from the perspective of a practitioner, as well as speculation on the prospects for electronics thermal engineering in years to come.
Resumo:
This Team Dargles poster is about the team's resource on the Copyright, Design and Patents Act 1988.
Resumo:
This document lists the references used by Team Dargles for both the poster and the resource for Info2009.
Resumo:
En aquesta tesi s'aborda l'estudi de la turbulència convectiva, a partir d'un treball experimental realitzat a l'estany de Banyoles. Més concretament, els objectius s'emmarquen en dues categories diferents. En la primera, es pretén sistematitzar el marc teòric-conceptual de la turbulència i més concretament de la turbulència convectiva, el qual es troba molt dispers a la bibliografia i sovint enfocat des de perspectives prou diverses. Dins aquest primer objectiu també es pretén sistematitzar tot un conjunt d'eines experimentals de tractament de dades que ens permetran obtenir els valors de les velocitats de dissipació de l'energia cinètica turbulenta i de la variància de temperatura de forma automàtica y obtenir els fluxos turbulents. També volem abordar la caracterització del les escales turbulentes, pel que treballarem amb l'escala de Thorpe i utilitzarem l'anàlisi d'ondetes del senyal de microstructura tèrmica. Dins la segona categoria d'objectius, aquests aplicats directament a l'estany de Banyoles, es pretén aplicar els conceptes desenvolupats al primer objectiu en dos sistemes convectius, un de tipus plomall i l'altre del tipus multidifusiu. Dins aquest context, en els dos primers capítols es presenta teòricament com s'obtenen els fluxos turbulents i s'introdueixen els fenòmens convectius, i en el tercer i quart capítols es descriuen tot un conjunt d'eines d'anàlisi experimental que ens serviran per a l'estudi del cas concret de la convecció al fons de l'estany de Banyoles.
Resumo:
The identification, tracking, and statistical analysis of tropical convective complexes using satellite imagery is explored in the context of identifying feature points suitable for tracking. The feature points are determined based on the shape of complexes using the distance transform technique. This approach has been applied to the determination feature points for tropical convective complexes identified in a time series of global cloud imagery. The feature points are used to track the complexes, and from the tracks statistical diagnostic fields are computed. This approach allows the nature and distribution of organized deep convection in the Tropics to be explored.
Resumo:
This paper provides for the first time an objective short-term (8 yr) climatology of African convective weather systems based on satellite imagery. Eight years of infrared International Satellite Cloud Climatology Project-European Space Agency's Meteorological Satellite (ISCCP-Meteosat) satellite imagery has been analyzed using objective feature identification, tracking, and statistical techniques for the July, August, and September periods and the region of Africa and the adjacent Atlantic ocean. This allows various diagnostics to be computed and used to study the distribution of mesoscale and synoptic-scale convective weather systems from mesoscale cloud clusters and squall lines to tropical cyclones. An 8-yr seasonal climatology (1983-90) and the seasonal cycle of this convective activity are presented and discussed. Also discussed is the dependence of organized convection for this region, on the orography, convective, and potential instability and vertical wind shear using European Centre for Medium-Range Weather Forecasts reanalysis data.
Resumo:
The representation of the diurnal cycle in the Hadley Centre climate model is evaluated using simulations of the infrared radiances observed by Meteosat 7. In both the window and water vapour channels, the standard version of the model with 19 levels produces a good simulation of the geographical distributions of the mean radiances and of the amplitude of the diurnal cycle. Increasing the vertical resolution to 30 levels leads to further improvements in the mean fields. The timing of the maximum and minimum radiances reveals significant model errors, however, which are sensitive to the frequency with which the radiation scheme is called. In most regions, these errors are consistent with well documented errors in the timing of convective precipitation, which peaks before noon in the model, in contrast to the observed peak in the late afternoon or evening. When the radiation scheme is called every model time step (half an hour), as opposed to every three hours in the standard version, the timing of the minimum radiance is improved for convective regions over central Africa, due to the creation of upper-level layer-cloud by detrainment from the convection scheme, which persists well after the convection itself has dissipated. However, this produces a decoupling between the timing of the diurnal cycles of precipitation and window channel radiance. The possibility is raised that a similar decoupling may occur in reality and the implications of this for the retrieval of the diurnal cycle of precipitation from infrared radiances are discussed.
Resumo:
Convectively coupled equatorial waves are fundamental components of the interaction between the physics and dynamics of the tropical atmosphere. A new methodology, which isolates individual equatorial wave modes, has been developed and applied to observational data. The methodology assumes that the horizontal structures given by equatorial wave theory can be used to project upper- and lower-tropospheric data onto equatorial wave modes. The dynamical fields are first separated into eastward- and westward-moving components with a specified domain of frequency–zonal wavenumber. Each of the components for each field is then projected onto the different equatorial modes using the y structures of these modes given by the theory. The latitudinal scale yo of the modes is predetermined by data to fit the equatorial trapping in a suitable latitude belt y = ±Y. The extent to which the different dynamical fields are consistent with one another in their depiction of each equatorial wave structure determines the confidence in the reality of that structure. Comparison of the analyzed modes with the eastward- and westward-moving components in the convection field enables the identification of the dynamical structure and nature of convectively coupled equatorial waves. In a case study, the methodology is applied to two independent data sources, ECMWF Reanalysis and satellite-observed window brightness temperature (Tb) data for the summer of 1992. Various convectively coupled equatorial Kelvin, mixed Rossby–gravity, and Rossby waves have been detected. The results indicate a robust consistency between the two independent data sources. Different vertical structures for different wave modes and a significant Doppler shifting effect of the background zonal winds on wave structures are found and discussed. It is found that in addition to low-level convergence, anomalous fluxes induced by strong equatorial zonal winds associated with equatorial waves are important for inducing equatorial convection. There is evidence that equatorial convection associated with Rossby waves leads to a change in structure involving a horizontal structure similar to that of a Kelvin wave moving westward with it. The vertical structure may also be radically changed. The analysis method should make a very powerful diagnostic tool for investigating convectively coupled equatorial waves and the interaction of equatorial dynamics and physics in the real atmosphere. The results from application of the analysis method for a reanalysis dataset should provide a benchmark against which model studies can be compared.