936 resultados para MICRODISC ELECTRODES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemically modified electrodes based on hexacyanometalate films are presented as a tool in analytical chemistry. Use of amperometric sensors and/or biosensors based on the metal-hexacyanoferrate films is a tendency. This article reviews some applications of these films for analytical determination of both inorganic (e.g. As3+, S2O3(2-)) and organic (e.g. cysteine, hydrazine, ascorbic acid, gluthatione, glucose, etc.) compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Platinum is widely used as electrode in electrocatalytic processes, however the use of polycrystalline electrodes introduces a series of variables in the electrochemical system due to the aleatory contribution of all the crystallographic orientations with different surface packing of atoms. Single crystal platinum electrodes of low Miller index present surface structure of high regularity and serve as model to establish a correlation among the macroscopic and microscopic properties of the electrochemical interface. Therefore, the main aim of this work is the study of the voltammetric profiles of the reversible adsorption-desorption of hydrogen on Pt(100), Pt(110) and Pt(111), in order to correlate the electrochemical properties of each different orientation with the surface atomic structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Macroscopic samples of fullerene nanostructures are obtained in a modified arc furnace using the electric arc method with a Helium atmosphere at low pressures. High purity graphite rods are used as electrodes but, when drilled and the orifices filled with powders of transition metals (Fe, Co, Ni) acting as catalysts, the resulting particles are carbon nanostructures of the fullerene family, known as Single Wall Nanotubes (SWNTs). They have typical diameters of 1.4 nm, lengths up to tenths of microns and they are arranged together in bundles containing several SWNTs. Those samples are observed and analyzed using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM) techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most relevant advances on the analytical applications of chemically modified electrodes (CME) are presented. CME have received great attention due to the possibility of electrode surface modification including chemisorption, composite generation and polymer coating. In recent years, the interest in CME has increased overall to improve the sensitivity and selectivity of the electroanalytical probes, considering the electron mediator incorporation and the new conducting polymers development. The general procedures employed for the electrode modification and the operational characteristics of some electrochemical sensors are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

UNS S31254 SS electrodes have been built to substitute platinum in conductimetric titrations. The electrodes were tested in both acid-basic titration (chloridric acid and sodium hydroxide) and precipitation titration (sodium chloride and argentum nitrate as titrant). The practical application was exemplified from conductimetric tritations of HF ¾ HNO3 mixtures used in metalurgical industry to passivate stainless steels. The results were compared with those obtained using commercial platinum electrodes. The equivalent volumes obtained were comparable within 3% experimental error. Its application depends on the nature of electrolyte. These results have shown that stainless steel, less expensive than platinum (about three order of magnitude), can substitute platinum electrodes in routine analyses and didactic laboratories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review focuses the development of electrochemical detection systems coupled to capillary electrophoresis. Conductometric, amperometric, voltametric, and potentiometric modes of detection are reviewed. The positioning of the electrodes, interferences of high electric field, and the materials employed in the fabrication and modification of the electrodes are discussed. The advantages of the use of electrochemical detection with capillary electrophoresis, regarding to the sensitivity and selectivity, is exemplified with a large number of applications. Also, the use of electrochemical detection systems in microchip technology is addressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Self-assembled monolayers (SAMs) modified electrodes exhibit unique behavior that can greatly benefit electrochemical sensing. This brief review highlights the applications of SAM modified electrodes in electroanalytical chemistry. After a general introduction, which includes the approaches for SAM development, different electrochemical systems for detecting inorganic and organic species are described and discussed. Special attention to the coupling of biological sensing element to the SAM is given, which can selectively recognize the analyte. Future prospects are also evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large Hadron Collider (LHC) is the main particle accelerator at CERN. LHC is created with main goal to search elementary particles and help science investigate our universe. Radiation in LHC is caused by charged particles circular acceleration, therefore detectors tracing particles in existed severe conditions during the experiments must be radiation tolerant. Moreover, further upgrade of luminosity (up to 1035 cm-2s-1) requires development of particle detector’s structure. This work is dedicated to show the new type 3D stripixel detector with serious structural improvement. The new type of radiation-hard detector has a three-dimensional (3D) array of the p+ and n+ electrodes that penetrate into the detector bulk. The electrons and holes are then collected at oppositely biased electrodes. Proposed 3D stripixel detector demonstrates that full depletion voltage is lower that that for planar detectors. Low depletion voltage is one of the main advantages because only depleted part of the device is active are. Because of small spacing between electrodes, charge collection distances are smaller which results in high speed of the detector’s response. In this work is also briefly discussed dual-column type detectors, meaning consisting both n+ and p+ type columnar electrodes in its structure, and was declared that dual-column detectors show better electric filed distribution then single sided radiation detectors. The dead space or in other words low electric field region in significantly suppressed. Simulations were carried out by using Atlas device simulation software. As a simulation results in this work are represented the electric field distribution under different bias voltages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new way for the construction of silver electrodes utilizing recordable CDs. The new electrodes were explored for the quantification of chloride (by potentiometry/FIA), cyanide (by amperometry/FIA) and for lead analysis (by square wave voltammetry). For the flowing measurements, a digital multimeter, connected to a microcomputer (via RS 232 interface) was used to collect directly the potential signal (for Cl- measurements) or to take the output signal from a potentiostat (for CN- measurements). The square wave voltammetry analysis was performed in a commercial instrument. The results shown good performance of the new electrodes and the detection limit (s/n = 3) attained for these three analytes were: 0.2, 50, and 200 µg L-1 for Pb2+, Cl-, and CN- respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The anodic voltammetric behavior of 4-chlorophenol (4-CF) in aqueous solution has been studied on a Boron-doped diamond electrode using square wave voltammetry (SWV). After optimization of the experimental conditions, 4-CF was analyzed in pure and natural waters using a Britton-Robinson buffer with pH = 6.0 as the supporting electrolyte. Oxidation occurs at 0.80 V vs Ag/AgCl in a two-electron process controlled by adsorption of the species. The detection limits obtained were 6.4 µg L-1 in pure water and 21.5 µg L-1 for polluted water taken from a local creek, respectively. The combination of square wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After an introductory discussion emphasising the importance of electrochemistry for the so-called Green Chemical Processes, the article presents a short discussion of the classical ozone generation technologies. Next a revision of the electrochemical ozone production technology focusing on such aspects as: fundamentals, latest advances, advantages and limitations of this technology is presented. Recent results about fundamentals of electrochemical ozone production obtained in our laboratory, using different electrode materials (e.g. boron doped diamond electrodes, lead dioxide and DSAÒ-based electrodes) also are presented. Different chemical processes of interest to the solution of environmental problems involving ozone are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electroflotation (EF) with aluminum electrodes was applied in the treatment of Brazilian industrial coconut wastewater. The results show that EF with polarity inversion is a very good treatment when compared to others. The removal of pollutants in the wastewater after EF with polarity inversion was 96.3% of oils and grease, 99% of color and 66% of total organic carbon. Also, metal concentrations, turbidity and total solids were reduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nickel, palladium and platinum micro-crystals were dispersed in films covering a vitreous carbon plate electrode by ion exchange followed by electroreduction of their ions. These modified electrodes were used in the electrocatalytic hydrogenation of several substrates of different classes and their efficiency is reported. A comparison among them was performed based on the structural characteristics of the metals. A modified electrode containing platinum showed to be more efficient than a palladium modified electrode and the one of nickel was the less efficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to optimize the preparation of electrodes with riboflavin (RF) immobilized on a silica surface modified with niobium oxide and carbon paste. Electrode preparation was optimized employing a factorial design consisting of two levels and three factors. The electrochemical properties of immobilized RF were investigated by cyclic voltammetry. The factorial analysis was carried out analysing the current intensity (Ipa). It was possible to optimize the electrode to get the best reversibility in the redox process, i. e. the lowest separation between anodic and cathodic peak potentials and a current ratio close to unity. The concentration of supporting electrolyte has a small effect. The proportion has the highest effect and the interaction factor between proportion and mixture has also a significant effect on the current intensity.