997 resultados para Instalações de ar comprimido
Resumo:
The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis
Resumo:
The study and selection of an equipment of air conditioner for any type of environment, should be made without overestimate or undersizing the project. The undersizing does not provide an adequate comfort temperature if the environment is too hot because the air conditioner does not remove all the heat necessary in the environment. But if the project is oversized, energy consumption is higher and there is an unnecessary cost. To prevent these failures is necessary to make a calculation of the thermal load on the environment and choose the equipment that has a higher cooling capacity than the calculated heat load and closer to the calculated heat load. In this graduate work will be chosen an air-conditioned equipment for bus, showing the calculations made for the thermal load for various types of heat gain in this type of vehicle. The thermal load on vehicles is more complicated to calculate than in areas because there are several factors that vary with the movement of the vehicle. It will also explain the compression refrigeration cycle, which is the cooling system used in vehicles because it is weightless, compact and lower cost. From the calculated heat load, it will be chosen an air conditioner that best suits the project and, finally, a brief presentation of the selected equipment will be made
Resumo:
Are presented on this paper, concepts of corrective, preventive and predictive maintenances, following the prerequisites for planning and implementation of a maintenance plan. You also find the theoretical introduction of some measurement instruments accompanied by the necessary and recommended activities during routine maintenances of the electrical equipments in a building installation. Using case study, it is possible to assess a real maintenance plan applied to two occupied floors in a financial institution. The developing of a case study consolidates the effectiveness of the present concepts on this theoretical introduction and shows that the current maintenance plan can be improved in order to obtain better results on company productivity and reliability of equipments. As a conclusion, we can notice the importance of a solid maintenance plan and the need of including this theme on the graduation in Electrical Engineering
Resumo:
A necessidade de se ter profissionais capacitados para pensar a questão urbana e propor soluções inovadoras é o ponto de partida para a criação do curso de Arquitetura e Urbanismo na Faculdade de Ciências e Tecnologia da Universidade Estadual Paulista “Júlio de Mesquita Filho”. Quando da sua criação, toda a estruturação foi baseada na infraestrutura já existente no campus para que posteriormente novas instalações, adequadas às especificidades do curso, fossem pleiteadas. Com apenas oito anos de funcionamento, alunos e professores enfrentam dificuldades no desenvolvimento das atividades em função da falta de infraestrutura adequada. Dessa forma, o presente trabalho é dedicado ao desenvolvimento de um projeto que atenda de forma satisfatória as demandas existentes no curso. A partir da elaboração de estudos de projetos análogos e de analises das necessidades do campus e suas necessidades obtém‐se as diretrizes que encaminham para a escolha da uma área apropriada para implantação nesta unidade universitária e pautam o desenvolvimento do projeto, que busca inserir‐se de forma adequada ao contexto préexistente
Resumo:
This study aimed to develop a computer program which systematizes the structural shielding design calculation in diagnostic radiology facilities. For this purpose methodology of the National Council of Radiation Protection and Measurements (NCRP 147[5]) was used. By comparative statistics studies, it was verified if reference parameters values suggested by the US publication correspond to the average national values. The World Wide Web was chosen because of its characteristics as a powerful mean of communication, especially in terms of the wide variety of useful resources and easy access. To compare the reference values of some parameters proposed by NCRP 147 to Brazilian average, studies about the normalized workload per patient, performance of X-ray tube and primary air kerma, unshielded, at one meter from the focal point of the X-ray tube were made. Through this research, relative differences were found. In workload values this differences reached up to 50% in mammography compared to those presented by the NCRP 147; in X-ray tube performance the percentage differences reached 69% in dental radiology, and air kerma results amounted 31% in fluoroscopy. This demonstrates the importance of validation of international protocols to local realities
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
This paper addresses methods of reducing the electric energy consumption on residences by the means of constructive measures and replacement of electric devices. Analyzing their impacts on residential and national level based on data issued by IBGE (Brazilian Institute of Geography and Statistics) and PROCEL (National Program for Electricity Conservation).
Resumo:
The gas turbine (GT) is known to have: low cost of capital over the amount of energy, high flexibility, high reliability, short delivery time, commissioning and commercial operation at the beginning and quick departure. The gas turbine is also recognized for its superior environmental performance, manifested in air pollution containment and reducing greenhouse gases (Mahi, 1994). Gas turbines in simple cycle mode (SC) have long been used by utilities to limited power generation peak. In addition, manufacturing facilities use gas turbines for power generation units on site, often in combination with the process of heat production, such as hot water and steam process. In recent years, the performance of industrial gas turbines has been improved due to significant investments in research and development, in terms of fuel to electricity conversion efficiency, plant capacity, availability and reliability. The greater availability of energy resources such as natural gas (NG), the significant reduction of capital costs and the introduction of advanced cycles, have also been a success factor for the increased use of gas turbines to load applications base (Poulikas, 2004). Open Cycle Gas Turbine with a greater degree of heat to the atmosphere may alternatively be used to produce additional electricity using a steam cycle, or to compose a cogeneration process. The combined cycle (CC) uses the heat from the gas turbine exhaust gas to increase the power output and increase the overall efficiency of more than 50% second (Najjar, 2001). The initial discovery of these cycles in the commercial power generation market was possible due to the development of the gas turbine. Only from the 1970s that gas turbine inlet temperature and therefore the exhaust gas temperature was sufficiently high to allow a better efficiency in the combined cycle ... (Complete Abstract click electronic access below)
Resumo:
Tendo em vista a problemática mundial com relação à degradação dos materiais plásticos e sua dispersão no meio ambiente, e diante de estudo realizado anteriormente onde se observou alterações histopatológicas e bioquímicas na próstata de animais expostos ao DBP (Di-N-Butil-ftalato) no período perinatal, este estudo teve por objetivo avaliar o potencial carcinogênico do DBP administrado desde o período fetal e após iniciação pelo MNU em um modelo de carcinogênese prostática. Ratas prenhes foram divididas em 4 grupos experimentais: 2 tratados: n=16/grupo (TDBP100 e TDBP500) e 2 controles: n=8/grupo (CN e CMNU). O grupo TDBP100 foi exposto ao DBP (100 mg/kg) e o TDBP500 a 500 mg/kg do 15º. dia de gestação (DG15) até a 21º. dia pósnatal (DPN21), enquanto que os animais controle receberam o veículo. Após o desmame, os machos foram separados e os grupos tratados e CMNU receberam dose única de MNU (50 mg/Kg, i.p.) na 6ª. semana pós-natal. Metade dos animais tratados (n=8/grupo) continuaram recebendo o DBP (DBP100+ e DBP500+) após o desmame em doses semanais até o dia do sacrifício (DPN180), enquanto os demais foram mantidos pelo mesmo período sem tratamento (DBP100- e DBP500-).Após a aplicação do MNU, os animais foram submetidos a injeções semanais de Cipionato de Testosterona (promotor) 2mg/aplicação. No dia do sacrifício, o sangue foi coletado, os órgãos reprodutores foram pesados e fragmentos do lobo ventral da próstata foram processados para inclusão em resina e Paraplast para as análises estruturais; e imunocitoquímicas para a detecção de AR e ER. Fragmentos de próstata ventral foram congelados e estocados a -80ºC e após extração das proteínas, estas foram destinadas à reação de Western Blot para avaliar a expressão das mesmas proteínas. Houve diminuição na distância anogenital nos animais DBP500 no DPN1 quando comparado com o grupo controle apontando para o efeito efetivo do DBP ...
Resumo:
Is it possible to encapsulate in a pill the benefits of an analytical treatment? Quickly suspending the symptoms? Since the nineteenth century psychiatry has offered to the so called mentally ill "medieval forms" of treatment, as is the case of institutional admissions, the straightjacket, lobotomies, shock treatments, etc. What has changed since the mid-twentieth century advent of chlorpromazine, the first psychoactive drug, and the "psychopharmacological revolution"? Today with the Psychiatric Reform mental institutions admissions are being gradually abandoned, yet we see the rise of psychoactive drugs as protagonists in mental health treatment. This theoretical essay is an extension of a master's thesis in progress on the long-term use of psychotropic drugs. It falls within the field of mental health, specifically in the debate on the medicalization of society in contemporary processes of subjectivation of the psychiatric clinics and the treatment modalities currently offered to individuals in their suffering-existence. Thus, we seek to problematize this degrading psychiatric clinics, which produces what we call the pill-subject.
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Persistent Organic Pollutants (POPs) are chemical substances extraordinarily toxic and persistent in the environment. Due to these properties, POPs are targets of the Stockholm Convention which aims to provide means to eliminate production and use by encouraging the reduction and, where possible, eliminating the release of these contaminants to the environment. One of the articles of this _Convention aims to assess the basal levels of such substances in the environment to monitor both the reduction of release to the environment, and to assess human exposure, using analyzes of milk and air for example. Although efforts to control POPs production and release to the environment have been made, data about their levels in Brazil are still scarce, mainly in the atmosphere or indoor environment. Considering the permanence of people inside its house, this study presents a method for POP extraction from XAD-2 sorbent employed in indoor air sampling, with identification and quantification by GC-ECD. GC-ECD linear range of the studied analytes, congeners of polychlorinated biphenyls (PCB) (28, 52, 101, 118, 138, 153 and 180), DDTs and their metabolites (DDDs, DDEs) and endosullan (isomers c - and 13 - and metabolite endosulfan sulfate) ranged between 0.5 and 16.0 ng mL-I with r2 > 0.967. The method developing consist of selecting the extraction solvent system by agitation (90 rpm, 1 hour) with n-hexan,e (2 mL) or n-hexane:acetone (1:1, v/v) (2 mL), concentration the extract with a gentle N2 stream, and evaluation of breakthrough with passage or air through the fortified XAD-2 cartridge before extraction, employing a low volume air suction pump (Pump Model 224 universal-PCXR8; 5-5000 mL min-1, SKC Inc., Eighty Four, PA, USA), Calibrator Dry-Cal DC-Lite (BIOS, Butler, NJ, USA)). Two fortification levels were employed, 15 and 30 ng. After selecting n-hexane as extraction solvent, with accuracy and precision ranging...