864 resultados para Infrasound and low frequency noise-exposure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vertebroplasty restores stiffness and strength of fractured vertebral bodies, but alters their stress transfer. This unwanted effect may be reduced by using more compliant cements. However, systematic experimental comparison of structural properties between standard and low-modulus augmentation needs to be done. This study investigated how standard and low-modulus cement augmentation affects apparent stiffness, strength, and endplate pressure distribution of vertebral body sections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The standard treatment of fever in chemotherapy-induced neutropenia (FN) includes emergency hospitalization and empirical intravenous antimicrobial therapy. This study determined if first-day step-down to oral outpatient treatment is not inferior to continued standard regarding safety and efficacy in children with low-risk FN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional hepatitis B vaccines do not elicit adequate antibody production in 5-10% vaccinees. This trial tests the ability of a third-generation vaccine, containing PreS1 and PreS2 antigens in addition to the S antigen, to elicit seroprotective titres in documented non- and low-responders, compared with those to a conventional vaccine. In the primary population of non-responders (<10 IU/l anti-HBs antibodies after > or = 4 previous injections of conventional vaccine) an enhanced antibody response was seen to additional injections of the third-generation vaccine compared with a conventional vaccine (absolute difference 14.9%; P = 0.006). Enhanced antibody responses were also found in a population that included low responders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multicenter trial was performed to confirm the therapeutic efficacy and the toxicity profile of the combination of cladribine, cyclophosphamide and prednisone in low-grade non-Hodgkin's lymphoma (NHL) and chronic lymphocytic leukemia (CLL). Twenty-three adults with previously treated (61%) or untreated (39%) NHL International Working Formulation A or Binet B and C CLL were administered cladribine 0.1 mg/kg/day as a subcutaneous bolus for 5 days, intravenous cyclophosphamide 500 mg/m2 on day 1, and oral prednisone 40 mg/m2 on days 1-5, every 4 weeks. Unexpected early hematological toxicities led to dose modifications for pretreated patients who received cladribine for 3 days only up to a maximum of five courses. Responses were observed in 75%, with 7 patients obtaining a complete clinical and hematological response. Median duration of complete response was 9 months. Median time to progression or relapse was 31 months. Myelosuppression and infections were dose limiting whereas posttreatment complications, including fatalities, resulted from infections. Median overall survival time from trial entry was 60 months. Activity of the combination of cladribine, cyclophosphamide and prednisone was confirmed. However, in the specific setting of a multicenter trial, unexpected fatal infectious episodes occurred in pretreated patients. Great caution is thus required in these susceptible patients and the routine use of corticosteroids should probably be abandoned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Drug-reactive T cells are involved in most drug-induced hypersensitivity reactions. The frequency of such cells in peripheral blood of patients with drug allergy after remission is unclear. OBJECTIVE: We determined the frequency of drug-reactive T cells in the peripheral blood of patients 4 months to 12 years after severe delayed-type drug hypersensitivity reactions, and whether the frequency of these cell differs from the frequency of tetanus toxoid-reactive T cells. METHODS: We analyzed 5 patients with delayed-type drug hypersensitivity reactions, applying 2 methods: quantification of cytokine-secreting T cells by enzyme-linked immunospot (ELISpot), and fluorescent dye 5,6-carboxylfluorescein diacetate succinimidyl ester (CFSE) intensity distribution analysis of drug-reactive T cells. RESULTS: Frequencies found were between 0.02% and 0.4% of CD4(+) T cells reacting to the respective drugs measured by CFSE analysis, and between 0.01% and 0.08% of T cells as determined by ELISpot. Reactivity was seen neither to drugs to which the patients were not sensitized nor in healthy individuals after stimulation with any of the drugs used. CONCLUSION: About 1:250 to 1:10,000 of T cells of patients with drug allergy are reactive to the relevant drugs. This frequency of drug-reactive T cells is higher than the frequency of T cells able to recognize recall antigens like tetanus toxoid in the same subjects. A substantial frequency could be observed as long as 12 years later in 1 patient even after strict drug avoidance. Patients with severe delayed drug hypersensitivity reactions are therefore potentially prone to react again to the incriminated drug even years after strict drug avoidance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Experimental studies provide evidence that inhaled nanoparticles may translocate over the airspace epithelium and cause increased cellular inflammation. Little is known, however, about the dependence of particle size or material on translocation characteristics, inflammatory response and intracellular localization. RESULTS: Using a triple cell co-culture model of the human airway wall composed of epithelial cells, macrophages and dendritic cells we quantified the entering of fine (1 mum) and nano-sized (0.078 mum) polystyrene particles by laser scanning microscopy. The number distribution of particles within the cell types was significantly different between fine and nano-sized particles suggesting different translocation characteristics. Analysis of the intracellular localization of gold (0.025 mum) and titanium dioxide (0.02-0.03 mum) nanoparticles by energy filtering transmission electron microscopy showed differences in intracellular localization depending on particle composition. Titanium dioxide nanoparticles were detected as single particles without membranes as well as in membrane-bound agglomerations. Gold nanoparticles were found inside the cells as free particles only. The potential of the different particle types (different sizes and different materials) to induce a cellular response was determined by measurements of the tumour necrosis factor-alpha in the supernatants. We measured a 2-3 fold increase of tumour necrosis factor-alpha in the supernatants after applying 1 mum polystyrene particles, gold nanoparticles, but not with polystyrene and titanium dioxide nanoparticles. CONCLUSION: Quantitative laser scanning microscopy provided evidence that the translocation and entering characteristics of particles are size-dependent. Energy filtering transmission electron microscopy showed that the intracellular localization of nanoparticles depends on the particle material. Both particle size and material affect the cellular responses to particle exposure as measured by the generation of tumour necrosis factor-alpha.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with growth hormone deficiency (GHD) have increased cardiovascular risk and may show elevated triglyceride and reduced high density lipoprotein (HDL) cholesterol concentrations, two lipid abnormalities usually accompanied by increased small dense LDL in the 'atherogenic lipoprotein phenotype' (ALP). In the present study, we directly investigated (1) whether hypopituitary patients with GHD have increased small dense LDL; (2) whether growth hormone replacement therapy (GHRT) beneficially impact on such particles; (3) the prevalence of ALP in GHD and GHRT patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. METHODS: In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. RESULTS: Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. CONCLUSIONS: The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to explore a Kalman Filter approach to estimating swing of crane-suspended loads. Measuring real-time swing is needed to implement swing damping control strategies where crane joints are used to remove energy from a swinging load. The typical solution to measuring swing uses an inertial sensor attached to the hook block. Measured hook block twist is used to resolve the other two sensed body rates into tangential and radial swing. Uncertainty in the twist measurement leads to inaccurate tangential and radial swing calculations and ineffective swing damping. A typical mitigation approach is to bandpass the inertial sensor readings to remove low frequency drift and high frequency noise. The center frequency of the bandpass filter is usually designed to track the load length and the pass band width set to trade off performance with damping loop gain. The Kalman Filter approach developed here allows all swing motions (radial, tangential and twist) to be measured without the use of a bandpass filter. This provides an alternate solution for swing damping control implementation. After developing a Kalman Filter solution for a two-dimensional swing scenario, the three-dimensional system is considered where simplifying assumptions, suggested by the two-dimensional study, are exploited. One of the interesting aspects of the three-dimensional study is the hook block twist model. Unlike the mass-independence of a pendulum's natural frequency, the twist natural frequency depends both on the pendulum length and the load’s mass distribution. The linear Kalman Filter is applied to experimental data demonstrating the ability to extract the individual swing components for complex motions. It should be noted that the three-dimensional simplifying assumptions preclude the ability to measure two "secondary" hook block rotations. The ability to segregate these motions from the primary swing degrees of freedom was illustrated in the two-dimensional study and could be included into the three-dimensional solution if they were found to be important for a particular application.