864 resultados para Glass surfaces


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present algorithms for computing the differential geometry properties of intersection Curves of three implicit surfaces in R(4), using the implicit function theorem and generalizing the method of X. Ye and T. Maekawa for 4-dimension. We derive t, n, b(1), b(2) vectors and curvatures (k(1), k(2), k(3)) for transversal intersections of the intersection problem. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass ionomer cements are widely used in dentistry as restorative materials and adhesives for composite restorations. However, the results of genotoxicity studies using these materials are inconclusive in literature. The goal of this study was to examine the genotoxic and cytotoxic potential of three different glass ionomer cements available commercially (Ketac Cem, Ketac Molar and Vitrebond) by the single cell gel (comet) assay and trypan blue exclusion test, respectively. For this, such materials were exposed to Chinese hamster ovary (CHO) cells in vitro for 1 h at 37 degrees C. Data were assessed by Kruskall-Wallis nonparametric test. The results showed that the powder from Ketac Molar displayed genotoxicity only in the maximum concentration evaluated (100 mu g/mL). In the same way, the liquid from Vitrebond at 0.1% dilution caused an increase of DNA injury. Significant differences (P < 0.05) in cytotoxicity provoked by all powders tested of glass ionomer cements were observed for exposure at 1000 mu g/mL concentration. With respect to liquids of glass ionomer cements evaluated, the major toxic effect on cell viability was produced at 10%, beginning at the dilution of 0.5% for Vitrebond. Taken together, we conclude that some components of glass ionomer cements show both genotoxic and cytotoxic effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass-ionomer cements are widely used in dentistry as restorative materials and adhesives for composite restorations. A number of genotoxicity studies have been conducted using these materials with results conflicting so far. Thus, the approach was aimed to look at the genotoxic and cytotoxic potential of three different glass-ionomer cements available commercially (Ketac Cem, Ketac Molar and Vitrebond) by the single cell gel (comet) assay and trypan blue exclusion test, respectively. For this, such materials were exposed to mouse lymphoma cells in vitro for 1 h at 37 degrees C. Data were assessed by Kruskall-Wallis non-parametric test. The results showed that all powders assayed did not show genotoxic effects. on the other hand, the liquid from Vitrebond at 0.1% dilution caused an increase of DNA injury. Significant statistically differences (P < 0.05) in cytotoxicity provoked by all powders tested were observed for exposure at 1000 mu g mL(-1) concentration and 100 mu g mL(-1) for Ketac Molar. With respect to liquids of glass-ionomer cements evaluated, the major toxic effect on cell viability was produced at 1%, beginning at the dilution of 0.5% for Vitrebond. Taken together, these results support the notion that some components of glass-ionomer cements show both genotoxic and cytotoxic effects in higher concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to histologically analyze the influence of bioactive glass and/or acellular dermal matrix on bone healing in surgically created defects in the tibiae of 64 rats (Rattus norvegicus, albinus, Wistar). Materials and Methods: A 4-mm X 3-mm unicortical defect was created on the anterolateral surface of the tibia. Animals were divided into 4 groups: C, control; BG, the defect was filled with bioactive glass; ADM, the defect was covered with acellular dermal matrix; and BG/ADM, the defect was filled with bioactive glass and covered with acellular dermal matrix. Animals were sacrificed at 10 or 30 days postoperatively, and the specimens were removed for histologic processing. The formation of new bone in the cortical area of the defect was evaluated histomorphometrically. Results: At 10 and 30 days postoperatively, groups C (39.65% +/- 5.63% / 63.34% +/- 5.22%) and ADM (38.12% +/- 5.53 / 58.96% +/- 7.05%) presented a larger amount of bone formation compared to the other groups (P<.05). In the same periods, groups BG (13.10% +/- 6.29% / 29.5% +/- 5.56%) and BG/ADM (20.72% +/- 8.31% / 24.19% +/- 6.69%) exhibited statistically similar new bone formation. However, unlike the other groups, group BG/ADM did not present a significant increase in bone formation between the 2 time points. Conclusion: Based on these results, it can be concluded that all of the materials used in this study delayed bone healing in non-critical-size defects. INT J ORAL MAXILLOFAC IMPLANTS 2008;23:811-817

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to report the use of the subepithelial connective tissue graft technique combined with the coronally positioned flap on a composite resin-restored root surface to treat Miller Class I gingival recessions associated with deep cervical abrasions in maxillary central incisors. Clinical measurements, including gingival recession height, probing depth, and bleeding on probing (BoP), were recorded during the preoperative clinical examination and at 2, 6, 12, and 24 months postoperatively. During the follow-up periods, no periodontal pockets or BoP were observed. The periodontal tissue of the teeth presented normal color, texture, and contouring. In addition, it was observed that creeping attachment had occurred on the restoration. This case report shows that this form of treatment can be highly effective and predictable in resolving gingival recession associated with a deep cervical abrasion. (Quintessence Int 2012;43:597-602)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The restoration and recovery of the alveolar healing process are a challenge to dental surgeons to achieve satisfactory results at the osseointegration of implants and implant rehabilitation. Different operative technique and biomaterials are being used to reconstruct the framework of the alveolar process. One of the biomaterials used for this purpose is the bioactive glass. The aim of this study was to report clinical and histologic final results of 7 clinical reports of alveolar ridge augmentation using bioactive glass. Clinically, bioglass was able to maintain bone architecture of the alveolar bone and repaired satisfactory. Biopsy was performed on the histologic samples and showed bone formation in intimate contact to the particles of the biomaterial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Implant overdenture prostheses are prone to acrylic resin fracture because of space limitations around the implant overdenture components.Purpose. The purpose of this study was to evaluate the influence of E-glass fibers and acrylic resin thickness in resisting acrylic resin fracture around a simulated overdenture abutment.Material and methods. A model was developed to simulate the clinical situation of an implant overdenture abutment with varying acrylic resin thickness (1.5 or 3.0 mm) with or without E-glass fiber reinforcement. Forty-eight specimens with an underlying simulated abutment were divided into 4 groups (n=12): 1.5 mm acrylic resin without E-glass fibers identified as thin with no E-glass fiber mesh (TN-N); 1.5 mm acrylic resin with E-glass fibers identified as thin with E-glass fiber mesh (TN-F); 3.0 mm acrylic resin without E-glass fibers identified as thick without E-glass fiber mesh (TK-N); and 3.0 mm acrylic resin with E-glass fibers identified as thick with E-glass fiber mesh (TK-F). All specimens were submitted to a 3-point bending test and fracture loads (N) were analyzed with a 2-way ANOVA and Tukey's post hoc test (alpha=.05).Results. The results revealed significant differences in fracture load among the 4 groups, with significant effects from both thickness (P<.001) and inclusion of the mesh (P<.001). Results demonstrated no interaction between mesh and thickness (P=.690). The TN-N: 39 +/- 5 N; TN-F: 50 +/- 6.9 N; TK-N: 162 +/- 13 N; and TK-F: 193 +/- 21 N groups were all statistically different (P<.001).Conclusions. The fracture load of a processed, acrylic resin implant-supported overdenture can be significantly increased by the addition of E-glass fibers even when using thin acrylic resin sections. on a relative basis, the increase in fracture load was similar when adding E-glass fibers or increasing acrylic resin thickness. (J Prosthet Dent 2011;106:373-377)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of carbamide peroxide (CP) on surfaces of different restorative materials. Porcelain, composite resin, glass ionomer, and amalgam were analyzed in this study. Surface roughness (Ra) was measured before and after treatment with 10% and 15% CP. Fifteen percent CP increased Ra values in both the glass ionomer and amalgam subgroups, while 10% CP increased Ra values in the glass ionomer subgroup only. Changes in restorative material surfaces can be more severe when bleaching is completed without a clinician's supervision. Hence, thorough patient examinations must be done before, during, and after bleaching treatment. Int J Prosthodont 2011;24:155-157

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen's kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. on the other hand, radiographic examination and laser fluorescence were less efficient when used alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the prevalence of caries has decreased dramatically over the past decades, it has become a polarised disease, with most of subjects presenting low caries levels and few individuals accounting for most of the caries affected surfaces. Thus it become evident for the need of clinical approaches directed at these high-risk patients, in order to overcome problems related to compliance and low attendance at dental care centres. Slow-release fluoride devices were developed based on the inverse relationship existing between intra-oral fluoride levels and dental caries experience. The two main types of slow-release devices - copolymer membrane type and glass bead - are addressed in the present review. A substantial number of studies have demonstrated that these devices are effective in raising intra-oral F concentrations at levels able to reduce enamel solubility, resulting in a caries-protective effect. Studies in animals and humans demonstrated that the use of these devices was able to also protect the occlusal surfaces, not normally protected by conventional fluoride regimens. However, retention rates have been shown to be the main problem related to these devices and still requires further improvements. Although the results of these studies are very promising, further randomised clinical trials are needed in order to validate the use of these devices in clinical practice. The concept of continuously providing low levels of intra-oral fluoride has great potential for caries prevention in high caries-risk groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This prospective and controlled histologic study evaluates the impact of smoking on bone-to-implant contact, the bone density in the threaded area, and the bone density outside the threaded area around microimplants with anodized surface retrieved from human jaws.Methods: A total of 24 subjects (mean age 51.32 +/- 7.5 years) were divided in two groups: smokers (n = 13 subjects) and non-smokers (n = 11 subjects). Each subject received one microimplant with oxidized surface during conventional mandible or maxilla implant surgery. After 8 weeks, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis.Results: Three microimplants placed in smokers showed no osseointegration. The newly formed bone showed early stages of maturation, mainly in the non-smokers. Marginal bone loss, gap, and fibrous tissue were present around implants retrieved from smokers. Histometric evaluation indicated that the mean bone-to-implant contact ranged between 25.97% +/- 9.02% and 40.01% +/- 12.98% for smokers and non-smokers, respectively (P <0.001). Smokers presented 28.17% +/- 10.32% of bone density in the threaded area, whereas non-smokers showed 46.34% +/- 19.12%. The mean of bone density outside the threaded area ranged between 18.76% and 25.11% for smokers and non-smokers, respectively (P>0.05).Conclusion: The present data obtained in human subjects confirm that smoking has a detrimental effect on early bone tissue response around oxidized implant surfaces. J Periodontol 2010;81:575-583.