874 resultados para Federal High Performance Computing Program (U.S.)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Al llarg d'aquest treball es presenten les tecnologies i els processos que s'han fet servir en la construcció de l'esmentada botiga virtual i el seu gestor. L'objectiu és crear un programari flexible, portable, reutilitzable, d'alt rendiment i intel·ligible

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El programa experimental s’ha portat a terme dins el marc de les activitats del projecte TRUEFOOD, finançat per la UE per als anys 2007-2010. L’objectiu principal d’aquesta activitat ha estat l’avaluació dels continguts en àcid ascòrbic (vitamina C), polifenols totals, àcids fenòlics i flavonoides en mostres de tomàquet i enciam, produïts sota diferents condicions de camp (producció ecològica i convencional). Per aconseguir els resultats s’han utilitzat mètodes analítics basats en tècniques de cromatografia líquida d’alta eficàcia (HPLC) i d’ultra-alta eficàcia (UHPLC) acoblades a sistemes de detecció de diode array (DAD) i espectrometria de masses (MSn). Per a l’àcid ascòrbic, s’ha desenvolupat un mètode ràpid que ha permès la determinació d’aquest compost en diferents matrius vegetals amb el mínim pretractament de les mostres, utilitzant una fase estacionària HILIC (Fluorinated Stationary Phase). Els mètodes desenvolupats d’anàlisi de compostos fenòlics han permès realitzar les anàlisi de forma ràpida, a fi de processar el màxim nombre de mostres per a obtenir resultats representatius. S’ha realitzat una completa caracterització dels extractes de tomàquet i enciam, ampliant el coneixement descrit en la bibliografia sobre la seva composició fenòlica. En el cas de l’enciam, s’ha identificat quatre compostos fenòlics que mai abans han estat descrits i quantificats en aquesta hortalissa. La definició, amb precisió, dels continguts en vitamina C i compostos fenòlics en les mostres analitzades ha permès comparar els efectes de diferents tècniques de cultiu sobre les característiques nutricionals dels vegetals objecte de l’estudi. Els mètodes d’anàlisi desenvolupats i els resultats derivats del projecte seran publicats properament en revistes científiques de reconegut prestigi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Technological limitations and power constraints are resulting in high-performance parallel computing architectures that are based on large numbers of high-core-count processors. Commercially available processors are now at 8 and 16 cores and experimental platforms, such as the many-core Intel Single-chip Cloud Computer (SCC) platform, provide much higher core counts. These trends are presenting new sets of challenges to HPC applications including programming complexity and the need for extreme energy efficiency.In this work, we first investigate the power behavior of scientific PGAS application kernels on the SCC platform, and explore opportunities and challenges for power management within the PGAS framework. Results obtained via empirical evaluation of Unified Parallel C (UPC) applications on the SCC platform under different constraints, show that, for specific operations, the potential for energy savings in PGAS is large; and power/performance trade-offs can be effectively managed using a cross-layerapproach. We investigate cross-layer power management using PGAS language extensions and runtime mechanisms that manipulate power/performance tradeoffs. Specifically, we present the design, implementation and evaluation of such a middleware for application-aware cross-layer power management of UPC applications on the SCC platform. Finally, based on our observations, we provide a set of recommendations and insights that can be used to support similar power management for PGAS applications on other many-core platforms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the first part of this research, three stages were stated for a program to increase the information extracted from ink evidence and maximise its usefulness to the criminal and civil justice system. These stages are (a) develop a standard methodology for analysing ink samples by high-performance thin layer chromatography (HPTLC) in reproducible way, when ink samples are analysed at different time, locations and by different examiners; (b) compare automatically and objectively ink samples; and (c) define and evaluate theoretical framework for the use of ink evidence in forensic context. This report focuses on the second of the three stages. Using the calibration and acquisition process described in the previous report, mathematical algorithms are proposed to automatically and objectively compare ink samples. The performances of these algorithms are systematically studied for various chemical and forensic conditions using standard performance tests commonly used in biometrics studies. The results show that different algorithms are best suited for different tasks. Finally, this report demonstrates how modern analytical and computer technology can be used in the field of ink examination and how tools developed and successfully applied in other fields of forensic science can help maximising its impact within the field of questioned documents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The photodynamic effects of m-tetrahydroxyphenylchlorin (mTHPC) were assessed on human malignant mesothelioma, squamous cell carcinoma and adenocarcinoma xenografts grown in nude mice and were correlated with mTHPC uptake, histology and doubling time of the tumors. Non-thermal laser light was delivered to the tumor as surface radiation 4 days after intraperitoneal administration of 0.1 and 0.3 mg mTHPC/kg body weight, respectively. The extent of tumor necrosis was measured by histomorphometry. The mTHPC concentration in non-irradiated tumors was assessed by high-performance liquid chromatography (HPLC). The tumors were graded according to their doubling time and their vascular architecture as assessed by histology. The 0.1 mg/kg dose of mTHPC resulted in an equal uptake for all 3 tumor types but revealed a larger extent of photosensitized necrosis for adenocarcinoma, which displayed a delicate tumor stroma with numerous small capillary vessels, than for mesothelioma and squamous cell carcinoma, which were both poor in stroma and vessels. The 0.3 mg/kg dose of mTHPC resulted in a 2-fold higher tumor uptake for all 3 tumor types and in a larger extent of necrosis for mesothelioma and squamous cell carcinoma, but not for adenocarcinoma xenografts, compared with the lower drug dose. Our results demonstrate that different tumor xenografts respond differently to mTHPC-PDT for a given drug-light condition. In this setting, the photosensitizing effect was more closely related to the vascular architecture of the tumors than to the sensitizer uptake and doubling time of the different tumors

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-dose cefepime therapy is recommended for febrile neutropenia. Safety issues have been raised in a recent meta-analysis reporting an increased risk of mortality during cefepime therapy. Cefepime-related neurological toxicity has been associated with overdosing due to severe renal dysfunction. This study aimed to investigate the association between cefepime plasma concentrations and neurological toxicity in febrile neutropenic patients. Cefepime trough concentrations (by high-performance liquid chromatography) were retrospectively analyzed for 30 adult febrile neutropenic patients receiving the recommended high-dose regimen (6 g/day for a glomerular filtration rate [GFR] of >50 ml/min). The dose adjustment to renal function was evaluated by the ratio of the cefepime daily dose per 100 ml/min of glomerular filtration. The association between cefepime plasma concentrations and neurological toxicity was assessed on the basis of consistent neurological symptoms and/or signs (by NCI criteria). The median cefepime concentration was 8.7 mg/liter (range, 2.1 to 38 mg/liter) at a median of 4 days (range, 2 to 15 days) after the start of therapy. Neurological toxicity (altered mental status, hallucinations, or myoclonia) was attributed to cefepime in 6/30 (20%) patients (median GFR, 45 ml/min; range, 41 to 65 ml/min) receiving a median dose of 13.2 g/day per 100 ml/min GFR (range, 9.2 to 14.3 g/day per 100 ml/min GFR). Cefepime discontinuation resulted in complete neurological recovery for five patients and improvement for one patient. A multivariate logistic regression model confirmed high cefepime concentrations as an independent predictor of neurological toxicity, with a 50% probability threshold at ≥22 mg/liter (P = 0.05). High cefepime plasma concentrations are associated with neurological toxicity in febrile neutropenic patients with mild renal dysfunction. Careful adherence to normalized dosing per 100 ml/min GFR is crucial. Monitoring of plasma concentrations may contribute to preventing neurological toxicity of high-dose therapy for this life-threatening condition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Earth System Models (ESM) have been successfuly developed over past few years, and are currently beeing used for simulating present day-climate, seasonal to interanual predictions of climate change. The supercomputer performance plays an important role in climate modeling since one of the challenging issues for climate modellers is to efficiently and accurately couple earth System components on present day computers architectures. At the Barcelona Supercomputing Center (BSC), we work with the EC- Earth System Model. The EC- Earth is an ESM, which currently consists of an atmosphere (IFS) and an ocean (NEMO) model that communicate with each other through the OASIS coupler. Additional modules (e.g. for chemistry and vegetation ) are under development. The EC-Earth ESM has been ported successfully over diferent high performance computin platforms (e.g, IBM P6 AIX, CRAY XT-5, Intelbased Linux Clusters, SGI Altix) at diferent sites in Europ (e.g., KNMI, ICHEC, ECMWF). The objective of the first phase of the project was to identify and document the issues related with the portability and performance of EC-Earth on the MareNostrum supercomputer, a System based on IBM PowerPC 970MP processors and run under a Linux Suse Distribution. EC-Earth was successfully ported to MareNostrum, and a compilation incompatibilty was solved by a two step compilation approach using XLF version 10.1 and 12.1 compilers. In addition, the EC-Earth performance was analyzed with respect to escalability and trace analysis with the Paravear software. This analysis showed that EC-Earth with a larger number of IFS CPUs (<128) is not feasible at the moment since some issues exists with the IFS-NEMO balance and MPI Communications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The diagnosis of hypertension in children is difficult because of the multiple sex-, age-, and height-specific thresholds to define elevated blood pressure (BP). Blood pressure-to-height ratio (BPHR) has been proposed to facilitate the identification of elevated BP in children. OBJECTIVE: We assessed the performance of BPHR at a single screening visit to identify children with hypertension that is sustained elevated BP. METHOD: In a school-based study conducted in Switzerland, BP was measured at up to three visits in 5207 children. Children had hypertension if BP was elevated at the three visits. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) for the identification of hypertension were assessed for different thresholds of BPHR. The ability of BPHR at a single screening visit to discriminate children with and without hypertension was evaluated with receiver operating characteristic (ROC) curve analyses. RESULTS: The prevalence of systolic/diastolic hypertension was 2.2%. Systolic BPHR had a better performance to identify hypertension compared with diastolic BPHR (area under the ROC curve: 0.95 vs. 0.84). The highest performance was obtained with a systolic BPHR threshold set at 0.80 mmHg/cm (sensitivity: 98%; specificity: 85%; PPV: 12%; and NPV: 100%) and a diastolic BPHR threshold set at 0.45 mmHg/cm (sensitivity: 79%; specificity: 70%; PPV: 5%; and NPV: 99%). The PPV was higher among tall or overweight children. CONCLUSION: BPHR at a single screening visit had a high performance to identify hypertension in children, although the low prevalence of hypertension led to a low PPV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CodeML (part of the PAML package) im- plements a maximum likelihood-based approach to de- tect positive selection on a specific branch of a given phylogenetic tree. While CodeML is widely used, it is very compute-intensive. We present SlimCodeML, an optimized version of CodeML for the branch-site model. Our performance analysis shows that SlimCodeML substantially outperforms CodeML (up to 9.38 times faster), especially for large-scale genomic analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several studies have reported high performance of simple decision heuristics multi-attribute decision making. In this paper, we focus on situations where attributes are binary and analyze the performance of Deterministic-Elimination-By-Aspects (DEBA) and similar decision heuristics. We consider non-increasing weights and two probabilistic models for the attribute values: one where attribute values are independent Bernoulli randomvariables; the other one where they are binary random variables with inter-attribute positive correlations. Using these models, we show that good performance of DEBA is explained by the presence of cumulative as opposed to simple dominance. We therefore introduce the concepts of cumulative dominance compliance and fully cumulative dominance compliance and show that DEBA satisfies those properties. We derive a lower bound with which cumulative dominance compliant heuristics will choose a best alternative and show that, even with many attributes, this is not small. We also derive an upper bound for the expected loss of fully cumulative compliance heuristics and show that this is moderateeven when the number of attributes is large. Both bounds are independent of the values ofthe weights.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the first time, an albite orthogneiss has been recognised and dated within the HP-LT blueschist facies metabasites and metapelites of the Ile de Groix. It is characterised by a peraluminous composition, high LILE, Th and U contents, MORB-like HREE abundances and moderate Nb and Y values. A U-Pb age of 480.8 +/- A 4.8 Ma was obtained by LA-ICP-MS dating of zircon and titanite. It is interpreted as the age of the magmatic emplacement during the Early Ordovician. Morphologically different zircon grains yield late Neoproterozoic ages of 546.6-647.4 Ma. Zircon and titanite U-Pb ages indicate that the felsic magmatism from the Ile de Groix is contemporaneous with the acid, pre-orogenic magmatism widely recognised in the internal zones of the Variscan belt, related to the Cambro-Ordovician continental rifting. The magmatic protolith probably inherited a specific chemical composition from a combination of orogenic, back-arc and anorogenic signatures because of partial melting of the Cadomian basement during magma emplacement. Besides, the late Devonian U-Pb age of 366 +/- A 33 Ma obtained for titanite from a blueschist facies metapelite corresponds to the age of the HP-LT peak metamorphism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actualment un típic embedded system (ex. telèfon mòbil) requereix alta qualitat per portar a terme tasques com codificar/descodificar a temps real; han de consumir poc energia per funcionar hores o dies utilitzant bateries lleugeres; han de ser el suficientment flexibles per integrar múltiples aplicacions i estàndards en un sol aparell; han de ser dissenyats i verificats en un període de temps curt tot i l’augment de la complexitat. Els dissenyadors lluiten contra aquestes adversitats, que demanen noves innovacions en arquitectures i metodologies de disseny. Coarse-grained reconfigurable architectures (CGRAs) estan emergent com a candidats potencials per superar totes aquestes dificultats. Diferents tipus d’arquitectures han estat presentades en els últims anys. L’alta granularitat redueix molt el retard, l’àrea, el consum i el temps de configuració comparant amb les FPGAs. D’altra banda, en comparació amb els tradicionals processadors coarse-grained programables, els alts recursos computacionals els permet d’assolir un alt nivell de paral•lelisme i eficiència. No obstant, els CGRAs existents no estant sent aplicats principalment per les grans dificultats en la programació per arquitectures complexes. ADRES és una nova CGRA dissenyada per I’Interuniversity Micro-Electronics Center (IMEC). Combina un processador very-long instruction word (VLIW) i un coarse-grained array per tenir dues opcions diferents en un mateix dispositiu físic. Entre els seus avantatges destaquen l’alta qualitat, poca redundància en les comunicacions i la facilitat de programació. Finalment ADRES és un patró enlloc d’una arquitectura concreta. Amb l’ajuda del compilador DRESC (Dynamically Reconfigurable Embedded System Compile), és possible trobar millors arquitectures o arquitectures específiques segons l’aplicació. Aquest treball presenta la implementació d’un codificador MPEG-4 per l’ADRES. Mostra l’evolució del codi per obtenir una bona implementació per una arquitectura donada. També es presenten les característiques principals d’ADRES i el seu compilador (DRESC). Els objectius són de reduir al màxim el nombre de cicles (temps) per implementar el codificador de MPEG-4 i veure les diferents dificultats de treballar en l’entorn ADRES. Els resultats mostren que els cícles es redueixen en un 67% comparant el codi inicial i final en el mode VLIW i un 84% comparant el codi inicial en VLIW i el final en mode CGA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CMS has established the medicaid Quality Improvement which serves to fulfill the objectives of they Medicaid Quality goal established through the Federal Government Performance and Results At. One of the objectives of the goal calls for the Centers foe Medicare and Medicaid Services to work in partnership with State Medicaid Directors to develop a Nation Medicaid Quality Framework that will articulate broad principles and a common vision of quality for the program.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the first report of 6 tasks to be performed in an effort to establish locally-based quality and performance criteria for asphalts, and ultimately to develop performance-related specifications based on simple physicochemical methods. Three of the most promising chemical methods (high performance liquid chromatography (HPLC), thermal analysis, and X-ray diffraction were selected to analyze 4 different types of samples. The results will indicate the fundamental asphalt property variables that directly affect the field performance in Iowa. The details of the materials and procedures employed are described, and the results of the tests are presented.