903 resultados para FEMORAL-SHAFT FRACTURES
Resumo:
PURPOSE: The aim of this study was to determine occupational facial fractures in central Switzerland. Concomitant injuries were also studied. MATERIALS AND METHODS: The Department of Cranio-Maxillofacial Surgery at the University Hospital in Berne provides a 24-hour maxillofacial trauma service for its population (1.6 million). The present study was comprised of 42 patients (8.4% of treated maxillofacial injuries) with occupational maxillofacial fractures registered at this unit between 2000 and 2002. Information on the topic of occupation, the cause of the accidents, and the topographic location of the fractures was analyzed. RESULTS: The mean age of the patients was 44.4 years, with a male to female ratio of 41:1. Sixty-nine percent of the injuries occurred in farm and forestry workers and in construction laborers during the summertime (33%). Workers in these occupations carried a 127-fold (farm and forestry workers) and a 44-fold (construction laborers) higher risk of incurring maxillofacial fractures than did service and office workers. Injuries were most frequently (43%) caused by a thrown, projected, or falling object. Eighty-two percent of the fractures occurred in the midface region and at the skull base. Fifty-nine percent of the patients had concomitant injuries. In 69%, surgery was necessary, the mean duration of their hospital stay being 4.8 days. CONCLUSION: The probability of sustaining work-related maxillofacial traumata is correlated to the nature of the occupation. Farm and forestry workers are at the highest risk, most frequently injured by being struck by an object or an animal. The introduction of personalized safety measures should become obligatory in high-risk occupations.
Resumo:
OBJECTIVE: Postmenopausal bone loss and osteoporotic fractures can be prevented by hormone replacement therapy (HRT). However, opposed HRT may increase the risk of breast cancer above that associated with estrogen alone and in non-hysterectomized women estrogen substitution alone increases the risk of uterine cancer, which triggered renewed interest in long-cycle HRT regimens (estrogen replacement therapy with progesterone-free intervals up to 6 months). The effects on bone of such long-cycle HRT regimens are unknown. The objective of the present study was to compare the effects on bone and the endometrium of long-cycle HRT and conventional HRT. METHODS: Seventy-three healthy non-hysterectomized postmenopausal women were randomized to either conventional HRT (estradiol (E2) 2 mg/d during 12 days, E2 2 mg/d plus 1 mg/d of norethisterone acetate (NETA) during 10 days, E2 1 mg/d for 6 days) or long-cycle HRT treatment (two cycles with E2 2 mg/d during 28 days, followed by one cycle of conventional HRT and repeated every 3 months). Primary endpoint was the change in bone mineral density (BMD) at the lumbar spine (LS) over 24 months. RESULTS: BMD at LS increased significantly versus baseline in both treatment groups (conventional HRT +3.8 +/- 0.6%, long-cycle HRT +3.3 +/- 0.5%, p < 0.0001 for both) with no significant difference between treatment groups over 24 months. Similar significant BMD increases versus baseline were observed at the femoral neck, while biochemical markers of bone turnover (osteocalcin and deoxypyridinoline) were significantly decreased over 24 months. There were no endometrial or breast related adverse events reported. CONCLUSION: Long-cycle HRT may be a valid alternative to conventional HRT with regard to protection against postmenopausal bone loss.
Resumo:
OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.
Resumo:
Early radiographic detection of femoroacetabular impingement might prevent initiation and progression of osteoarthritis. The structural abnormality in femoral-induced femoroacetabular impingement (cam type) is frequently asphericity at the anterosuperior head/neck contour. To determine which of six radiographic projections (anteroposterior, Dunn, Dunn/45 degrees flexion, cross-table/15 degrees internal rotation, cross-table/neutral rotation, and cross-table/15 degrees external rotation) best identifies femoral head/neck asphericity, we studied 21 desiccated femurs; 11 with an aspherical femoral head/neck contour and 10 with a spherical femoral head/neck contour. To radiographically quantify femoral head asphericity, we measured the angle where the femoral head/neck leaves sphericity (angle alpha). The aspherical femoral head/neck contours had a greater maximum angle alpha (70 degrees ) compared with the spherical head/neck contours (50 degrees ). The angle alpha varied depending on the radiographic projection: it was greatest in the Dunn view with 45 degrees hip flexion (71 degrees +/- 10 degrees ) and least in the cross-table view in 15 degrees external rotation (51 degrees +/- 7 degrees ). Diagnosis of a pathologic femoral head/neck contour depends on the radiologic projection. The Dunn view in 45 degrees or 90 degrees flexion or a cross-table projection in internal rotation best show femoral head/neck asphericity, whereas anteroposterior or externally rotated cross-table views are likely to miss asphericity. Level of Evidence: Prognostic study, level II-1 (retrospective study).
Resumo:
A total knee arthroplasty performed with navigation results in more accurate component positioning with fewer outliers. It is not known whether image-based or image-free-systems are preferable and if navigation for only one component leads to equal accuracy in leg alignment than navigation of both components. We evaluated the results of total knee arthroplasties performed with femoral navigation. We studied 90 knees in 88 patients who had conventional total knee arthroplasties, image-based total knee arthroplasties, or total knee arthroplasties with image-free navigation. We compared patients' perioperative times, component alignment accuracy, and short-term outcomes. The total surgical time was longer in the image-based total knee arthroplasty group (109 +/- 7 minutes) compared with the image-free (101 +/- 17 minutes) and conventional total knee arthroplasty groups (87 +/- 20 minutes). The mechanical axis of the leg was within 3 degrees of neutral alignment, although the conventional total knee arthroplasty group showed more (10.6 degrees ) variance than the navigated groups (5.8 degrees and 6.4 degrees , respectively). We found a positive correlation between femoral component malalignment and the total mechanical axis in the conventional group. Our results suggest image-based navigation is not necessary, and image-free femoral navigation may be sufficient for accurate component alignment.
Resumo:
OBJECTIVES: We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation. MATERIALS AND METHODS: A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis. RESULTS: The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications. CONCLUSIONS: The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.
A systematic review of prophylactic antibiotics in the surgical treatment of maxillofacial fractures
Resumo:
PURPOSE: A systematic review was performed to find evidence for prophylactic administration of antibiotics in relation to treatment of maxillofacial fractures. METHODS: Four studies were retrieved that fulfilled most of the requirements of being randomized controlled clinical trials. RESULTS: An analysis of these studies showed a 3-fold decrease in the infection rate of mandibular fractures in the antibiotic treated groups compared with the control groups. A variety of antibiotics had been used with an apparently uniform effect. A "1-shot" regimen or a 1-day treatment course had a similar or perhaps even better effect than 7 days of treatment. No infections were related to condylar, maxillary, or zygoma fractures. CONCLUSION: A 1-shot or 1-day administration of prophylactic antibiotics seem to be the best documented to reduce infections in the management of mandibular fractures not involving the condylar region.