993 resultados para Experimental setup


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thesis submitted for the degree of Doctor of Philosophy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In practice the robotic manipulators present some degree of unwanted vibrations. The advent of lightweight arm manipulators, mainly in the aerospace industry, where weight is an important issue, leads to the problem of intense vibrations. On the other hand, robots interacting with the environment often generate impacts that propagate through the mechanical structure and produce also vibrations. In order to analyze these phenomena a robot signal acquisition system was developed. The manipulator motion produces vibrations, either from the structural modes or from endeffector impacts. The instrumentation system acquires signals from several sensors that capture the joint positions, mass accelerations, forces and moments, and electrical currents in the motors. Afterwards, an analysis package, running off-line, reads the data recorded by the acquisition system and extracts the signal characteristics. Due to the multiplicity of sensors, the data obtained can be redundant because the same type of information may be seen by two or more sensors. Because of the price of the sensors, this aspect can be considered in order to reduce the cost of the system. On the other hand, the placement of the sensors is an important issue in order to obtain the suitable signals of the vibration phenomenon. Moreover, the study of these issues can help in the design optimization of the acquisition system. In this line of thought a sensor classification scheme is presented. Several authors have addressed the subject of the sensor classification scheme. White (White, 1987) presents a flexible and comprehensive categorizing scheme that is useful for describing and comparing sensors. The author organizes the sensors according to several aspects: measurands, technological aspects, detection means, conversion phenomena, sensor materials and fields of application. Michahelles and Schiele (Michahelles & Schiele, 2003) systematize the use of sensor technology. They identified several dimensions of sensing that represent the sensing goals for physical interaction. A conceptual framework is introduced that allows categorizing existing sensors and evaluates their utility in various applications. This framework not only guides application designers for choosing meaningful sensor subsets, but also can inspire new systems and leads to the evaluation of existing applications. Today’s technology offers a wide variety of sensors. In order to use all the data from the diversity of sensors a framework of integration is needed. Sensor fusion, fuzzy logic, and neural networks are often mentioned when dealing with problem of combing information from several sensors to get a more general picture of a given situation. The study of data fusion has been receiving considerable attention (Esteban et al., 2005; Luo & Kay, 1990). A survey of the state of the art in sensor fusion for robotics can be found in (Hackett & Shah, 1990). Henderson and Shilcrat (Henderson & Shilcrat, 1984) introduced the concept of logic sensor that defines an abstract specification of the sensors to integrate in a multisensor system. The recent developments of micro electro mechanical sensors (MEMS) with unwired communication capabilities allow a sensor network with interesting capacity. This technology was applied in several applications (Arampatzis & Manesis, 2005), including robotics. Cheekiralla and Engels (Cheekiralla & Engels, 2005) propose a classification of the unwired sensor networks according to its functionalities and properties. This paper presents a development of a sensor classification scheme based on the frequency spectrum of the signals and on a statistical metrics. Bearing these ideas in mind, this paper is organized as follows. Section 2 describes briefly the robotic system enhanced with the instrumentation setup. Section 3 presents the experimental results. Finally, section 4 draws the main conclusions and points out future work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental and Finite Element study was performed on the bending behaviour of wood beams of the Pinus Pinaster species repaired with adhesively-bonded carbon–epoxy patches, after sustaining damage by cross-grain failure. This damage is characterized by crack growth at a small angle to the beams longitudinal axis, due to misalignment between the wood fibres and the beam axis. Cross-grain failure can occur in large-scale in a wood member when trees that have grown spirally or with a pronounced taper are cut for lumber. Three patch lengths were tested. The simulations include the possibility of cohesive fracture of the adhesive layer, failure within the wood beam in two propagation planes and patch interlaminar failure, by the use of cohesive zone modelling. The respective cohesive properties were estimated either by an inverse method or from the literature. The comparison with the tests allowed the validation of the proposed methodology, opening a good perspective for the reduction of costs in the design stages of these repairs due to extensive experimentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of the power loss generated in mechanical transmissions and the use of low friction biodegradable lubricants has been attracting considerable attention in recent times. Therefore, it is necessary to develop methods to test and evaluate the performance of such lubricants and compare them with conventional ones. In this sense, a Four-Ball Machine was modified allowing the test of rolling bearings. A 51107 thrust ball bearing was used to test two different greases and the corresponding base oils. Friction torque and operating temperatures were continuously monitored to quantify the power loss and the heat evacuation for each lubricant tested. Copyright © 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study to evaluate the power dissipation of gears was performed. Three low-loss gear models were manufactured using standard 20° pressure angle tools. Austempered ductile iron (ADI) and 20MnCr5 carburized steel gears were tested in an FZG gear test machine using mineral, ester and polyalphaolephine (PAO)-based oils. The results compare power dissipation, the influence of different tooth flank geometries, materials and lubricants. This work concludes that conventional power-transmission gears can be replaced by these improved and more efficient low–loss models, which can be produced using common tools and that steel gears can be successfully replaced by austempered ductile iron gears.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyolefins are especially difficult to bond due to their non-polar, non-porous and chemically inert surfaces. Acrylic adhesives used in industry are particularly suited to bond these materials, including many grades of polypropylene (PP) and polyethylene (PE), without special surface preparation. In this work, the tensile strength of single-lap PE and mixed joints bonded with an acrylic adhesive was investigated. The mixed joints included PE with aluminium (AL) or carbon fibre reinforced plastic (CFRP) substrates. The PE substrates were only cleaned with isopropanol, which assured cohesive failures. For the PE CFRP joints, three different surfaces preparations were employed for the CFRP substrates: cleaning with acetone, abrasion with 100 grit sand paper and peel-ply finishing. In the PE AL joints, the AL bonding surfaces were prepared by the following methods: cleaning with acetone, abrasion with 180 and 320 grit sand papers, grit blasting and chemical etching with chromic acid. After abrasion of the CFRP and AL substrates, the surfaces were always cleaned with acetone. The tensile strengths were compared with numerical results from ABAQUS® and a mixed mode (I+II) cohesive damage model. A good agreement was found between the experimental and numerical results, except for the PE AL joints, since the AL surface treatments were not found to be effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a Masters degree in Computer Science

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current Electrocardiographic (ECG) signal acquisition methods are generally highly intrusive, as they involve the use of pre-gelled electrodes and cabled sensors placed directly on the person, at the chest or limbs level. Moreover, systems that make use of alternative conductive materials to overcome this issue, only provide heart rate information and not the detailed signal itself. We present a comparison and evaluation of two types of dry electrodes as interface with the skin, targeting wearable and low intrusiveness applications, which enable ECG measurement without the need for any apparatus permanently fitted to the individual. In particular, our approach is targeted at ECG biometrics using signals collected at the hand or finger level. A custom differential circuit with virtual ground was also developed for enhanced usability. Our work builds upon the current stateof-the-art in sensoring devices and processing tools, and enables novel data acquisition settings through the use of dry electrodes. Experimental evaluation was performed for Ag/AgCl and Electrolycra materials, and results show that both materials exhibit adequate performance for the intended application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram estudados aspectos da infecção e da imunidade experimentais em um roedor — o Mastomys natalensis — inoculado com a cepa LE (Belo Horizonte) do Schistosoma mansoni, comparando os resultados com os do camundongo albino, animal tido como melhor modelo experimental. Os parâmetros estudados ofereceram resultados em tudo semelhantes aos encontrados em camundongos, com o M. natalensis se mostrando bastante sensível à infecção pelo S. mansoni, sendo de grande utilidade para os estudos da biologia do parasito e/ou observações da imu-nologia advinda da infecção. Somando-se a tal fato a grande reprodutividade do animal em cativeiro, a criação fácil, o manejo e a manutenção simples em laboratório, sugere-se que seja o M. natalensis usado como modelo experimental alternativo nos diversos estudos da esquistossomose mansoni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C3H/He and C57B1/6 mice were inoculated with 500 Trypanosoma cruzi trypomastigotes (Strain Y). During the acute phase infected mice presented parasitemia and enlargement of lymph nodes and spleens and intracellular parasites were observed in the heart. Examinations of cells derived from spleen and lymph nodes showed increased numbers of IgM and IgG-bearing cells. During the peak of splenomegaly, about day 17 post-infections, splenic lymphocytes showed a marked decrease in responsiveness to T and B-cell mitogens, parasite antigens and plaque forming cells (PFC) to sheep red blood cells (SRBC). Unfractionated or plastic adherent splenic cells from mice, obtained during the acute phase were able to suppress the response to mitogens by lymphocytes from uninfected mice. During the chronic phase. Disappearance of parasitemia and intracellular parasites in the hearts as well as a decrease in spleen size, was observed. These changes preceded the complete recovery of responsiveness to mitogens and T. cruzi antigens by C57B1/6 splenic lymphocytes. However, this recovery was only partial in the C3H/He mice, known to be more sensitive to T. cruzi infection. Partial recovery of humoral immune response also occurred in both strains of mice during the chronic phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Roedores silvestres, classificados como Holochilus brasiliensis nanus Thomas,1897, foram capturados na cidade de São Bento, pertencente à Região da Baixada, do Estado do Maranhão, Brasil, naturalmente infectados com formas adultas de filaria, na cavidade peritoneal, e microfilárias sangüíneas, assim como, com esquistossoma mansoni (vermes adultos e granulomas peri-ovulares hepáticos; intestinais; pulmonares; esplênicos e pancreáticos). Animais nascidos em Biotério, descendentes de Holochilus da Região da Baixada, foram infectados experimentalmente com Leishmania m. amazonensis e Schistosoma mansoni. Em observações semanais, foram encontradas lesões teciduais, semelhantes às que se desenvolvem em hamsters infectados com Leishmania, e hipergamaglobulinemia. Nos esquistossomóticos, foram constatadas hipergamaglobulinemia e reações granulomatosas similares às encontradas nos animais infectados naturalmente. Foram observadas, também, lesões hepática graves, semelhantes às encontradas na esquistossomose humana. Estes achados sugerem a utilização do Holochilus b. nanus como modelo experimental destas três doenças tropicais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we study the electro-rheological behaviour of a series of four liquid crystal (LC) cyanobiphenyls with a number of carbon atoms in the alkyl group, ranging from five to eight (5CB–8CB). We present the flow curves for different temperatures and under the influence of an external electric field, ranging from 0 to 3 kV/mm, and the viscosity as a function of the temperature, for the same values of electric field, obtained for different shear rates. Theoretical interpretation of the observed behaviours is proposed in the framework of the continuum theory of Leslie–Ericksen for low molecular weight nematic LCs. In our analysis, the director alignment angle is only a function of the ratio between the shear rate and the square of the electric field – boundary conditions are neglected. By fitting the theoretical model to the experimental data, we are able to determine some viscosity coefficients and the dielectric anisotropy as a function of temperature. To interpret the behaviour of the flow curves near the nematic–isotropic transitions, we apply the continuum theory of Olmsted–Goldbart, which extends the theory of Leslie–Ericksen to the case where the degree of alignment of the LC molecules can also vary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devido a evidências sugestivas da possibilidade de transmissão da toxoplasmose por transfusão de sangue, os autores se propuseram avaliar o papel preventivo da violeta de genciana, à semelhança do que já é estabelecido para a doença de Chagas. O experimento em camundongos revelou a ação profilática da violeta de genciana quando adicionado ao sangue a ser transfundido na concentração de 1/1000 e permanência por 48 horas na geladeira.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were carried out with Sw albino mice and it was concluded that the percutaneous route via abdominal skin was significatively more efficient than tail immersion method and subcutaneous infection; the subcutaneous injection was significatively more efficient than the percutaneous infection through the tail; this latter and the intraperitoneal injection, resulted in similar infections, but were significatively less efficient than the others. Significative difference was also observed in the comparison between the subcutaneous route and percutaneous infection through ear pinna. The influence of the site of skin infection by percutaneous route was also discussed.