899 resultados para Eigen COD


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The improper disposal of nitrogen in receiving water courses causes problems such as toxicity to living beings through the consumption of oxygen to meet the nitrogen demand, eutrophication and nitrate contamination of aquifers. For this reason it is often necessary to be carried out complementary treatment of wastewater to eliminate or reduce the concentration of this compound in the wastewater. The objective of this study is to evaluate the biological removal of nitrogen compounds using submerged aerated and anoxic filters as post-treatment of an anaerobic system, with low cost and innovative technology, which in previous studies has shown high removal efficiency of organic matter and great potential biological nitrogen compounds removal. The simple design with perforated hoses for air distribution and filling with plastic parts proved to be very efficient in relation to organic matter removal and nitrification. The system presented, in the best stage, efficiency in converting ammonia to nitrate by 71%, and produced a final effluent concentration below 10 mg / L of NH3-N. In addition, carbon concentration was removed by 77%, producing final effluent with 24 mg/L COD. However, denitrification in anoxic filter was not effective even with the addition of an external carbon source. There was a reduction of up to 56% of nitrogen caused by the process of simultaneous nitrification and denitrification (SND). The high voids space presented by this type of support material coupled with direct aeration of the sludge, allows the respiration of biomass retained between the endogenous phase, increased cell retention time and sludge retention capacity, producing a final effluent with turbidity less than 5 UT and total suspended solids around 5.0 mg/L

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this research was the development of a procedure to measure biological kinetics of organic matter oxidation and nitrification in constructed wetland, by using respirometric techniques. Columns simulating cores of vertical subsurface flow systems were investigated. The oxygen uptake rate (OUR) of the columns was calculated on the basis of the difference of DO concentrations measured continuously at the top and at the bottom of the column. From the respirogram, the following kinetic parameters have been evaluated: maximum rate of oxidation of readily biodegradable COD, maximum rate of nitrification, endogenous respiration of the biomass grown inside the bed. In order to improve the interpretation of the respirograms, additional respirometric tests were carried out on the wetland columns by using pure substrates, such as acetate (carbon source) and ammonium (substrate for nitrification). The kinetic parameters obtained from respirograms can be useful for control and design of constructed wetlands or for improving nutrient and carbon mass balances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho objetivou a avaliação da remoção de matéria orgânica carbonácea e nitrogenada, bem como a determinação do fluxo crítico, em biorreator de membranas, com zona pré-anóxica, tratando águas residuárias industriais da produção de aminoácidos. O reator foi operado sob carga orgânica volumétrica de 1,91 kg.DQO.m-3.d-1 e 0,18 kg.NTK.m-3.d-1; a recirculação do reator aeróbio para o reator anóxico foi de quatro vezes a vazão afluente. O reator apresentou médias de remoção de DQO, NTK e NT de 97, 98 e 92%, respectivamente. O sistema de ultrafiltração foi testado em vários fluxos entre 25 e 37 L.m-2.h-1 e determinou-se o fluxo crítico de 28 L.m-2.h-1 quando operado com 11,4 g.L-1 de SST e 35 dias de tempo de retenção celular. Os resultados mostraram que houve viabilidade técnica no uso de biorreator de membranas para remoção de matéria orgânica de águas residuárias industriais da produção de aminoácidos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The organic matter. (OM) removal efficiency in the biochemical oxygen demand (BOD) and chemical oxygen demand (COD) forms for domestic wastewater and semi-intensive fish culture effluents by using three phase aerobic fluidized bed reactors with circulation in concentric tubes was studied. Three different ratios between external and internal areas by different internal diameter configurations (100, 125 and 150mm) to the same external diameter of 250mm were used; sand for filters and granulated activated carbon were used as supporting media. The reactors were tested for three hydraulic retention times: 11.5min to the R100, and 3h for the R125 and R150 reactors. The results demonstrated that this kind of reactors had good performance in the BOD and COD removal for different concentrations of waste waters. BOD mean removal efficiencies obtained were: 47% at the R100 reactor, 57% and 93% of raw and filtered BOD respectively at R125, 48 and 89% of raw and filtered BOD at R150. The COD mean calculated removal efficiencies were: 75% at the R100 reactor, 56 and 86% of raw and filtered COD at R125, and 54 and 86% of raw and filtered COD at R150. In the case of domestic wastewater it is necessary to provide a solids removal system at the reactor outflow in order to increase the removal of suspended OM from the final effluent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, electrochemical technology was used to treat synthetic wastewater containing Methyl Red (MR) and Blue Novacron (BN) by anodic oxidation using anodes platinum (Pt) and real samples of textile effluents using DDB anodes and platinum (Pt). The removal of color from the galvanostatic electrolysis of synthetic wastewater MR and BN, and the actual sample has been observed under different conditions (different current densities and temperature variation). The investigation of these parameters was performed in order to establish the best conditions for removal of color and chemical oxygen demand (BOD). According to the results obtained in this study, the electrochemical oxidation processes suitable for the degradation process of color and COD in wastewater containing such textile dyes, because the electrocatalytic properties of Pt and BDD anodes consumption energy during the electrochemical oxidation of synthetic solutions AN and MR and real sample, mainly depend on the operating parameters of operation, for example, the synthetic sample of MR, energy consumption rose from 42,00kWhm-3 in 40 mAcm-2 and 25 C to 17,50 kWhm-3 in 40mAcm-2 and 40 C, from the BN went 17,83 kWhm-3 in 40mAcm and 40°C to 14,04 kWhm- 3 in 40mAcm-2 and 40 C (data estimated by the volume of treated effluent). These results clearly indicate the applicability of electrochemical treatment for removing dyes from synthetic solutions and real industrial effluents