957 resultados para DETECTORS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A combined method for evaluating radon (Rn-222) and progeny (Pb-214 and Bi-214) in water was developed by using inexpensive alpha scintillation Counting and gamma ray spectrometry through NaI(Tl) scintillation detectors. A groundwater sample collected at the Pocos de Caldas alkaline massif in Brazil was submitted to the technique in order to assure its applicability by comparing the volumetric activities by different methods. Similar volumetric activity was determined for Pb-214 and Bi-214 in the sample analyzed that is compatible with the expected condition of radioactive equilibrium between these nuclides. The combined method was successfully used to analyze groundwater samples from Guarani aquifer in S (a) over tildeo Paulo State, Brazil, and the results of the measurements indicated that Pb-214 and Bi-214 provide useful information concerning the evaluation of the drinking water quality in terms of radiological aspects. This is because they are directly identified in the water samples, without the need of requiring the assumption of the establishment of the transient equilibrium condition with its parent Rn-222. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the introduction of GC there has been an ongoing interest in reducing time of analysis resulting in new terms and definitions such as ultra fast gas chromatography (UF-GC). One of the most used definitions describes UF-GC as a technique that combines the employment of short narrow bore column with very fast temperature programming rates producing chromatographic peaks in the range of 50 ms and allowing separations times in 1-2 min or less. This paper summarizes the analytical approaches, the main parameters involved and the instrumentation towards UF-GC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, GdAlO3:Pr3+ was successfully prepared by the Pechini method at lower temperatures when compared to others methods such as solid-state synthesis and sol-gel process. In accordance to the XRD data, the fully crystalline single-phase GdAlO3 could be obtained at 900 degrees C. Luminescence measurements indicate Gd -> Pr3+ energy transfer. In the emission spectra, the P-3(0) ->(3) H-4 (blue emission) and D-1(2) ->(3) H-4 (red emission) transitions of Pr3+ ions can be observed and the ratio between their intensities depends on the Pr3+ content due to the cross-relaxation phenomenon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Assessing the composition of an area's bat fauna is typically accomplished by using captures or by monitoring echolocation calls with bat detectors. The two methods may not provide the same data regarding species composition. Mist nets and harp traps may be biased towards sampling low flying species, and bat detectors biased towards detecting high intensity echolocators. A comparison of the bat fauna of Fazenda Intervales, southeastern Brazil, as revealed by mist nets and harp trap captures, checking roosts and by monitoring echolocation calls of flying bats illustrates this point. A total of 17 species of bats was sampled. Fourteen bat species were captured and the echolocation calls of 12 species were recorded, three of them not revealed by mist nets or harp traps. The different sampling methods provided different pictures of the bat fauna. Phyllostomid bats dominated the catches in mist nets, but in the field their echolocation calls were never detected. No single sampling approach provided a complete assessment of the bat fauna in the study area. In general, bats producing low intensity echolocation calls, such as phyllostomids, are more easily assessed by netting, and bats producing high intensity echolocation calls are better surveyed by bat detectors. The results demonstrate that a combined and varied approach to sampling is required for a complete assessment of the bat fauna of an area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have developed a methodology for measuring the decay constant of the spontaneous fission of U-238, lambda(f), using nuclear particle track detectors where thermal neutron irradiation is unnecessary. This methodology is based on the fact that the radiation damage caused by spontaneous fission of trans-uranium elements bearing a mass number close to 238 are similar to U-238 spontaneous-fission ones. Loading a thick source of uranium (thickness greater than the fission fragment range) with a small amount of a suitable trans-uranium element (for instance, Pu-242, which presents a spontaneous fission half-life of 6.75(.)10(10) y), it is possible to determine the observation efficiency of a particle-track detector for fission fragments. Procedures concerning our thick source manufacture and uniformity tests of the trans-uranium distribution are also presented. These results make it possible for the exposure of thick uranium sources (without trans-uranium element) to lead to a lambda(f) value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pyroelectric sensors work as a thermal transducer converting the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. Ferroelectric ceramics and ferroelectric polymers have been extensively used as thermal detectors. More recently the research in the field of pyroelectricity has been concentrated on discovering materials with higher figures of merit (FOM), which means better sensing materials. Composite materials obtained with ferroelectric ceramics embedded in polymer host have received great attention because of their formability, mechanical resistance and the possibility to change their dielectric property varying the volume fraction of ceramic particles. In this work composite films made of modified lead titanate (PZ34) and poly(ether-ether-ketone) (PEEK) were characterized and used as sensing element to measure X-ray intensity in the ortovoltage range (120 - 300 kVp). The sensor response varies from 2.70 V to 0.80 V in the energy fluency range of 6.30 to 37.20 W/m(2). Furthermore the absorbed energy was analyzed as a function of the ionizing energy. The results indicate that the PZ34/PEEK composite with 60/40 vol.% can be useful to monitor X-ray radiation therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider inertial and accelerated Unruh-DeWitt detectors moving in a background thermal bath and calculate their excitation rate. It is shown that for fast moving detectors such a thermal bath does not affect substantially the excitation probability. Our results are discussed in connection with a possible proposal of testing the Unruh effect in high energy particle accelerators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organotin compounds, largely used as biocides in antifouling paints, are among the most toxic materials introduced into the aquatic environment. Sensitive analytical methods are thus required to characterize their occurrence in environmental and biological matrices. The comparison between two different photometric detectors in terms of analytical performance was carried out for the analysis of organotin compounds. A flame photometric detector (FPD) and a pulsed flame photometric detector (PFPD) were optimized. Their respective sensitivity, linearity range and selectivity were evaluated. Limits of detection obtained for a tributyltin compound (TBT) were 5.0 and 0.9 pg (as Sn) for the FPD and PFPD, respectively, using a 390 nm filter. The PFPD showed higher selectivity, besides reduced gas consumption in the flame, and is very attractive for organotin compound speciation in complex environmental matrices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A quantitative study was made about the effects caused by ionizing irradiation on materials used for dental restoration (amalgams, compound resins and compomere), aiming to alleviate in bearers of head and neck cancer, the possible harmful effects of radiotherapy perceived when the repaired teething is within the radiation field. Research also encourages further studies for new alternative materials to be used in dental repair of patients submitted to radiotherapy for head and neck cancer. Test samples were submitted to a gamma radiation beam coming from a cobalt-therapy source and analyzed according to the X-ray fluorescence technique, comparing the chemical composition of the samples before and after irradiation. Radiation detectors such as an ionization chamber and a Geiger-Muller were used to measure the rate of residual dose. Gamma spectrometry with Nal detectors was also performed on the same samples. Results showed that there was no significant change in the chemical composition and that at post-irradiation, samples did not exhibit radiation emission, that is to say they had not become radioactive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show that the emission of a Minkowski particle by a general class of scalar sources as described by inertial observers corresponds to either the emission or the absorption of a Rindler particle as described by uniformly accelerated observers. Our results are discussed in connection with the current controversy whether uniformly accelerated detectors radiate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid and simple gas chromatographic method for determinating cyprodinil, fludioxonil, pyrimethanil, and tebuconazole in grapes, must, and wine is described. An on-line microextraction method was used with a one-step extraction-partition procedure. Nitrogen-phosphorus and mass spectrometric detectors were used, because of their low sensitivity and high selectivity. Because of high selectivity of detector, no cleanup was necessary and the extract was concentrated 5 times. Recoveries from fortified grapes, must, and wine ranged from 93 to 110%. Limits of determination were 0.05 mg/kg for cyprodinil and pyrimethanil and 0.10 mg/kg for fludioxonil and tebuconazole.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new concept of fault detection and isolation using robust observation for systems with random noises is presented. The method selects the parameters from components that may fault during the process and constructs well conditioned robust observers, considering sensors faults. To isolate component failures via robust observation, a bank of detection observers is constructed, where each observer is only sensitive to one specified component failure while robust to all other component failures.