916 resultados para Cannula, Ventricular assist device, Rotary blood pump, Heart failure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Aim: It is unclear to what extent diabetes modulates the ageing-related adaptations of cardiac geometry and function. Methods and Results: We examined 1005 adults, aged 25-74 years, from a population-based survey at baseline in 1994/5 and at follow-up in 2004/5. We compared persistently non-diabetic individuals (ND; no diabetes at baseline and at follow-up, n = 833) with incident (ID; non-diabetic at baseline and diabetic at follow-up, n = 36) and with prevalent diabetics (PD; diabetes at baseline and follow-up examination, n = 21). Left ventricular (LV) geometry and function were evaluated by echocardiography. Statistical analyses were performed with multivariate linear regression models. Over ten years the PD group displayed a significantly stronger relative increase of LV mass (+9.34% vs. +23.7%) that was mediated by a more pronounced increase of LV end-diastolic diameter (+0% vs. +6.95%) compared to the ND group. In parallel, LA diameter increased (+4.50% vs. +12.7%), whereas ejection fraction decreased (+3.02% vs. -4.92%) more significantly in the PD group. Moreover, at the follow-up examination the PD and ID groups showed a significantly worse diastolic function, indicated by a higher E/EM ratio compared with the ND group (11.6 and 11.8 vs. 9.79, respectively). Conclusions: Long-standing diabetes was associated with an acceleration of age-related changes of left ventricular geometry accumulating in an eccentric remodelling of the left ventricle. Likewise, echocardiographic measures of systolic and diastolic ventricular function deteriorated more rapidly in individuals with diabetes. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Systolic myocardial Doppler velocity accurately identifies coronary artery disease. However, these velocities may be affected by age, hemodynamic responses to stress, and left ventricular cavity size. We sought to examine the influences of these variables on myocardial velocity during dobutamine stress in patients with normal wall motion. Methods One hundred seventy-nine consecutive patients with normal dobutamine echocardiograms were studied. Color myocardial tissue Doppler data were obtained at rest and peak stress, and peak systolic myocardial velocity (PSV) was measured in all basal and midventricular segments. Velocities at rest and peak stress were compared with left ventricular diastolic and systolic volumes, blood pressure, heart rate, and age by Pearson correlation and interdecile analysis by use of analysis of variance. Results The only clinical variable correlating with velocity was age; PSV showed only mild correlation with age at rest (r(2) = 0.01, P = .001) and peak stress (r(2) = 0.02, P = .001), but the normal peak velocity was significantly different between the extremes of age (<44 years and >74 years). There was very weak correlation of PSV with systolic and diastolic blood pressure (r(2) < 0.01), heart rate (r(2) < 0.01), systemic vascular resistance (r(2) = 0.08), and left ventricular volumes (r(2) < 0.01). Conclusions Peak systolic velocity during dobutamine stress is relatively independent of hemodynamic factors and left ventricular cavity size. The extremes of age may influence peak systolic Doppler velocities. These results suggest that peak systolic velocity may be a robust quantitative measure during dobutamine echocardiography across most patient subgroups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abnormal left ventricular (LV) filling is common, but not universal, in hypertensive LV hypertrophy (LVH). We sought to elucidate the relative contributions of myocardial structural changes, loading and hypertrophy to LV dysfunction in 113 patients: 85 with hypertensive LVH and 28 controls without LVH and with normal filling. Patients with normal dobutamine stress echocardiography and no history of coronary artery disease were selected, in order to exclude a contribution from ischaemia or scar. Abnormal LV filling was identified in 65 LVH patients, based on Doppler measurement of transmitral filling and annular velocities. All patients underwent grey-scale and colour tissue Doppler imaging from three apical views, which were stored and analysed off line. Integrated backscatter (113) and strain rate imaging were used to detect changes in structure and function; average cyclic variation of 113, strain rate and peak systolic strain were calculated by averaging each segment. Calibrated 113 intensity, corrected for pericardial 113 intensity, was measured in the septum and posterior wall from the parasternal long-axis view. Patients with LVH differed significantly from controls with respect to all backscatter and strain parameters, irrespective of the presence or absence of abnormal LV filling. LVH patients with and without abnormal LV filling differed with regard to age, LV mass and incidence of diabetes mellitus, but also showed significant differences in cyclic variation (P < 0.01), calibrated 113 in the posterior wall (P < 0.05) and strain rate (P < 0.01), although blood pressure, heart rate and LV systolic function were similar. Multivariate logistic regression analysis demonstrated that age, LV mass index and calibrated IB in the posterior wall were independent determinants of abnormal LV filling in patients with LVH. Thus structural and functional abnormalities can be detected in hypertensive patients with LVH with and without abnormal LV filling. In addition to age and LVH, structural (not functional) abnormalities are likely to contribute to abnormal LV filling, and may be an early sign of LV damage. 113 is useful for the detection of myocardial abnormalities in patients with hypertensive LVH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective : To report the history of the Royal Alexandra Hospital for Children (RAHC) Papua New Guinea (PNG) cardiac surgical programme and describe the selection, preoperative clinical features and postoperative outcome of children with congenital heart disease managed by the programme. Methods : Details for each of the PNG cardiac patients admitted to RAHC following selection by visiting cardiologists between 1978 and 1994 were entered into a database, and analysed and interpreted. Results : A congenital heart defect was confirmed in 165 of the 170 children selected. The male to female ratio was 1:1 and the mean age on admission to RAHC was 5.5 years. Almost all of the children for whom data were available (98%) had a weight for age and 41% had a height for age less than the 3rd centile. One-sixth had delayed milestones. A large number were tachypnoeic, in heart failure, or had pulmonary hypertension on admission. Ventricular septal defect and tetralogy of Fallot were the commonest defects, and lesions such as aortic stenosis, coarctation of the aorta and transposition of the great arteries were absent or rare. Thirty-one (19%) of the children selected initially did not receive surgery because of pulmonary hypertension, or because the lesions did not fall within the programme guidelines for operation. One hundred and twenty-nine children had corrective and four had palliative procedures. Half of the operated children had postoperative complications. Eight children died, all following open-heart procedures, giving a case fatality rate of 6%. Preoperative tachypnoea, hepatomegaly, cardiac failure and pulmonary hypertension were strongly associated with poor outcome. Conclusions : The programme was an arduous exercise for all organizations concerned, but achieved comparatively good short-term outcomes. The experience gained should assist in planning for similar programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

B-type natriuretic peptide (BNP) levels increase in systolic heart failure (HF). However, the value of BNP in hypertensive patients with suspected diastolic HF (symptoms suggestive of HF but normal ejection fraction) and its relation to myocardial function in these patients is unclear. We prospectively studied 72 ambulatory hypertensive subjects (40 women, mean age 58 +/- 8 years) with exertional dyspnea and ejection fraction greater than or equal to50%. Diastolic function was evaluated with transmitral and pulmonary venous Doppler, mitral annular velocities (pulsed-wave tissue Doppler), and flow propagation velocity (color M-mode). Systolic function was assessed with strain and strain rate derived from color tissue Doppler imaging. BNP was related to myocardial function and the presence or absence of global diastolic dysfunction. By conventional Doppler criteria, 34 patients had normal left ventricular diastolic function and 38 had isolated diastolic dysfunction. BNP values were higher in patients with diastolic dysfunction (46 +/- 48 vs 20 +/- 20 pg/ml, p = 0.004) and were related independently to blood pressure, systolic strain rate, left atrial function (p < 0.01 for all), and age (p = 0.015). Patients with diastolic dysfunction and pseudonormal filling had higher BNP levels compared with impaired relaxation (89 +/- 47 vs 35 +/- 42 pg/ml, p = 0.001). However, 79% of patients with diastolic dysfunction had BNP levels within the normal range. We conclude that in ambulatory hypertensive patients with symptoms suggestive of mild HF and normal ejection fraction, BNP is related to atrial and ventricular systolic parameters, blood pressure, and age. Although elevated in the presence of diastolic dysfunction, the BNP level mostly is in the normal range and, therefore, has limited diagnostic value in stable patients with suspected diastolic HF. (C) 2003 by Excerpta Medica, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Descreve-se a utilização de um sistema de assistência mecânica bi-ventricular, para-corpórea (Berlin Heart), como ponte para transplante, numa criança de dois anos, sofrendo de miocardiopatia dilatada. O período de assistência durou três meses e meio e o transplante foi bem sucedido. Descreve-se o caso clínico, os protocolos usados e revêem-se as indicações, as técnicas e os problemas com a assistência ventricular mecânica em crianças.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resistant hypertension (RHTN) is a multifactorial disease characterized by blood pressure (BP) levels above goal (140/90 mmHg) in spite of the concurrent use of three or more antihypertensive drugs of different classes. Moreover, it is well known that RHTN subjects have high prevalence of left ventricular diastolic dysfunction (LVDD), which leads to increased risk of heart failure progression. This review gathers data from studies evaluating the effects of phosphodiesterase-5 (PDE-5) inhibitors (administration of acute sildenafil and short-term tadalafil) on diastolic function, biochemical and hemodynamic parameters in patients with RHTN. Acute study with sildenafil treatment found that inhibition of PDE-5 improved hemodynamic parameters and diastolic relaxation. In addition, short-term study with the use of tadalafil demonstrated improvement of LVDD, cGMP and BNP-32 levels, regardless of BP reduction. No endothelial function changes were observed in the studies. The findings of acute and short-term studies revealed potential therapeutic effects of IPDE-5 drugs on LVDD in RHTN patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Heart failure is a severe complication associated with doxorubicin (DOX) use. Strain, assessed by two-dimensional speckle tracking (2D-STE), has been shown to be useful in identifying subclinical ventricular dysfunction. Objectives: a) To investigate the role of strain in the identification of subclinical ventricular dysfunction in patients who used DOX; b) to investigate determinants of strain response in these patients. Methods: Cross-sectional study with 81 participants: 40 patients who used DOX ±2 years before the study and 41 controls. All participants had left ventricular ejection fraction (LVEF) ≥55%. Total dose of DOX was 396mg (242mg/ms2). The systolic function of the LV was evaluated by LVEF (Simpson), as well as by longitudinal (εLL), circumferential (εCC), and radial (εRR) strains. Multivariate linear regression (MLR) analysis was performed using εLL (model 1) and εCC (model 2) as dependent variables. Results: Systolic and diastolic blood pressure values were higher in the control group (p < 0.05). εLL was lower in the DOX group (-12.4 ±2.6%) versus controls (-13.4 ± 1.7%; p = 0.044). The same occurred with εCC: -12.1 ± 2.7% (DOX) versus -16.7 ± 3.6% (controls; p < 0.001). The S’ wave was shorter in the DOX group (p = 0.035). On MLR, DOX was an independent predictor of reduced εCC (B = -4.429, p < 0.001). DOX (B = -1.289, p = 0.012) and age (B = -0.057, p = 0.029) were independent markers of reduced εLL. Conclusion: a) εLL, εCC and the S’ wave are reduced in patients who used DOX ±2 years prior to the study despite normal LVEF, suggesting the presence of subclinical ventricular dysfunction; b) DOX was an independent predictor of reduced εCC; c) prior use of DOX and age were independent markers of reduced εLL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goals of the present study were to evaluate the kinetics of blood parasitism by examination of fresh blood, blood culture (BC) and PCR assays and their correlation with heart parasitism during two years of infection in Beagle dogs inoculated with the Be-78, Y and ABC Trypanosoma cruzi strains. Our results showed that the parasite or its kDNA is easily detected during the acute phase in all infected animals. On the other hand, a reduced number of positive tests were verified during the chronic phase of the infection. The frequency of positive tests was correlated with T. cruzi strain. The percentage of positive BC and blood PCR performed in samples from animals inoculated with Be-78 and ABC strains were similar and significantly larger in relation to animals infected with the Y strain.Comparison of the positivity of PCR tests performed using blood and heart tissue samples obtained two years after infection showed two different patterns associated with the inoculated T. cruzi strain: (1) high PCR positivity for both blood and tissue was observed in animals infected with Be-78 or ABC strains; (2) lower and higher PCR positivity for the blood and tissue, respectively, was detected in animals infected with Y strains. These data suggest that the sensitivity of BC and blood PCR was T. cruzi strain dependent and, in contrast, the heart tissue PCR revealed higher sensitivity regardless of the parasite stock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The Contegra bioprosthesis (valved heterologous bovine jugular vein) is used for reconstruction of the right ventricular outflow tract (RVOT) in congenital heart malformations and pulmonary valve replacement in different settings. Compared to pulmonary homografts, the Contegra conduit is readily available 'on the shelf'. So far, its use was mainly described in children. The aim of this study is to evaluate the feasibility and the outcome of Contegra graft implantation in the adult. METHODS: Between November 1999 and December 2007, a total of 32 Contegra grafts were implanted in 31 patients (24 men and 7 women), with a mean age of 35.7+/-10.5 years (range 18-54 years). All operations have been completed through median sternotomy with cardiopulmonary bypass. Indications included: Ross procedure for aortic valve disease (n=22); re-operation of corrected Fallot-tetralogy (n=5); isolated pulmonary valve disease (n=2); re-operation of double outlet right ventricle (DORV) (n=1); pulmonary stenosis in congenital dilated cardiomyopathy (DCM) (n=1). Conduit sizes included 22 mm (n=31), 20 mm (n=1). RESULTS: There was no hospital mortality and no valved conduit related early morbidity. In the median follow-up of 38 months (range 1-99 months) of 28 patients there was one late death, not conduit related (total mortality 3.6%). Re-operation for symptomatic graft stenosis was realised in two patients, 7 and 16 months after primo-implantation, corresponding to graft related late morbidity of 7.1%. CONCLUSIONS: In this small review of 32 operations using the Contegra graft for RVOT reconstruction in adult cardiac surgery for different indications, we observed good postoperative mid-term results concerning conduit function. Mean transpulmonary pressure gradients remain low (13.3+/-6.6 mmHg postoperative, 14.5+/-7.9 mmHg at follow-up). The use of the Contegra graft seems to be a good alternative to the homograft with low operative mortality and morbidity. Long-term outcome data are not available and further investigations must be performed to evaluate results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Recently, a compact cardiopulmonary support (CPS) system designed for quick set-up for example, during emergency cannulation, has been introduced. Traditional rectilinear percutaneous cannulas are standard for remote vascular access with the original design. The present study was designed to assess the potential of performance increase by the introduction of next-generation, self-expanding venous cannulas, which can take advantage of the luminal width of the venous vasculature despite a relatively small access orifice. METHODS: Veno-arterial bypass was established in three bovine experiments (69+/-10 kg). The Lifebridge (Lifebridge GmbH, Munich, Germany) system was connected to the right atrium in a trans-jugular fashion with various venous cannulas; and the oxygenated blood was returned through the carotid artery with a 17 F percutaneous cannula. Two different venous cannulas were studied, and the correlation between the centrifugal pump speed (1500-3900 RPM), flow and the required negative pressure on the venous side was established: (A) Biomedicus 19 F (Medtronic, Tolochenaz, Switzerland); (B) Smart canula 18 F/36 F (Smartcanula LLC, Lausanne, Switzerland). RESULTS: At 1500 RPM, the blood flow was 0.44+/-0.26 l min(-1) for the 19 F rectilinear cannula versus 0.73+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 2500 RPM the blood flow was 1.63+/-0.62 l min(-1) for the 19F rectilinear cannula versus 2.13+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 3500 RPM, the blood flow was 2.78+/-0.47 l min(-1) for the 19 F rectilinear cannula versus 3.64+/-0.39 l min(-1) for the 18/36 F self-expanding cannula (p<0.01 for 18/36 F vs 19 F). At 1500 RPM, the venous line pressure was 18+/-8 mmHg for the 19F rectilinear cannula versus 19+/-5 mmHg for the 18/36 F self-expanding cannula. At 2500 RPM the venous line pressure accounted for -22+/-32 mmHg for the 19 F rectilinear cannula versus 2+/-5 mmHg for the 18/36 F self-expanding cannula. At 3500 RPM, the venous line pressure was -112+/-42 mmHg for the rectilinear cannula versus 28+/-7 mmHg for the 18/36 F self-expanding cannula (p<0.01 for 18 F/36 F vs 19 F). Conclusions: The negative pressure required to achieve adequate venous drainage with the self-expanding venous cannula accounts for approximately 31% of the pressure necessary with the 19 F rectilinear cannula. In addition, a pump flow of more than 4 l min(-1) can be achieved with the self-expanding design and a well-accepted negative inlet pressure for minimal blood trauma of less than 50 mmHg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prospective epidemiological data have shown that blood pressure has a graded, continuous adverse effect on the risk of various forms of CVD (including stroke, myocardial infarction, heart failure, peripheral arterial disease and end-stage renal disease). 'Raised blood pressure' is frequently considered to be any systolic blood pressure greater than 115 mmHg. It accounts for 45% of all heart disease deaths and 51% of all stroke-related deaths [1], which together are the biggest causes of morbidity and mortality worldwide [2,3,4]. Annually, there are >17 million deaths due to CVD worldwide, of which 9.4 million are attributable to complications of raised blood pressure. This highlights the importance of both high-risk and population-based strategies in blood pressure management and control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effective pump function of the heart depends on the precise control of spatial and temporal patterns of electrical activation. Accordingly, the distribution and function of gap junction channels are important determinants of the conduction properties of myocardium and undoubtedly play other roles in intercellular communication crucial to normal cardiac function. Recent advances have begun to elucidate mechanisms by which the heart regulates intercellular electrical coupling at gap junctions in response to stress or injury. Although responses to increased load or injury are generally adaptive in nature, remodeling of intercellular junctions under conditions of severe stress creates anatomic substrates conducive to the development of lethal ventricular arrhythmias. Potential mechanisms controlling the level of intercellular communication in the heart include regulation of connexin turnover dynamics and phosphorylation.