991 resultados para Analytical Spectral Devices (ASD), FieldSpec Pro
Resumo:
Solving multi-stage oligopoly models by backward induction can easily become a com- plex task when rms are multi-product and demands are derived from a nested logit frame- work. This paper shows that under the assumption that within-segment rm shares are equal across segments, the analytical expression for equilibrium pro ts can be substantially simpli ed. The size of the error arising when this condition does not hold perfectly is also computed. Through numerical examples, it is shown that the error is rather small in general. Therefore, using this assumption allows to gain analytical tractability in a class of models that has been used to approach relevant policy questions, such as for example rm entry in an industry or the relation between competition and location. The simplifying approach proposed in this paper is aimed at helping improving these type of models for reaching more accurate recommendations.
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
While mobile technologies can provide great personalized services for mobile users, they also threaten their privacy. Such personalization-privacy paradox are particularly salient for context aware technology based mobile applications where user's behaviors, movement and habits can be associated with a consumer's personal identity. In this thesis, I studied the privacy issues in the mobile context, particularly focus on an adaptive privacy management system design for context-aware mobile devices, and explore the role of personalization and control over user's personal data. This allowed me to make multiple contributions, both theoretical and practical. In the theoretical world, I propose and prototype an adaptive Single-Sign On solution that use user's context information to protect user's private information for smartphone. To validate this solution, I first proved that user's context is a unique user identifier and context awareness technology can increase user's perceived ease of use of the system and service provider's authentication security. I then followed a design science research paradigm and implemented this solution into a mobile application called "Privacy Manager". I evaluated the utility by several focus group interviews, and overall the proposed solution fulfilled the expected function and users expressed their intentions to use this application. To better understand the personalization-privacy paradox, I built on the theoretical foundations of privacy calculus and technology acceptance model to conceptualize the theory of users' mobile privacy management. I also examined the role of personalization and control ability on my model and how these two elements interact with privacy calculus and mobile technology model. In the practical realm, this thesis contributes to the understanding of the tradeoff between the benefit of personalized services and user's privacy concerns it may cause. By pointing out new opportunities to rethink how user's context information can protect private data, it also suggests new elements for privacy related business models.
Resumo:
Vegeu el resum a l'inici del document del fitxer adjunt.
Resumo:
In case Krein's strings with spectral functions of polynomial growth a necessary and su fficient condition for the Krein's correspondence to be continuous is given.
Resumo:
RÉSUMÉ Le système rénine-angiotensine joue un rôle prépondérant dans la régulation de la pression sanguine et de la balance des sels ainsi que dans d'autres processus physiologiques et pathologiques. Lorsque la pression sanguine est trop basse, les cellules juxtaglomérulaires sécrètent la rénine, qui clivera l'angiotensinogène circulant (sécrété majoritairement par le foie) pour libérer l'angiotensine I, qui sera alors transformée en angiotensine II par l'enzyme de conversion de l'angiotensine. Ce système est régulé au niveau de la sécrétion de la rénine par le rein. La rénine est une enzyme de type protéase aspartique. Elle est produite sous la forme d'un précurseur inactif de haut poids moléculaire appelé prorénine, qui peut être transformé en rénine active. Si le rôle de la prorégion de la rénine n'est pas encore connu, plusieurs études ont montré qu'elle pourrait être un auto-inhibiteur. Des travaux menés sur d'autres enzymes protéolytique ont mis en évidence un rôle de chaperon de leurs prorégions. Dans la circulation, la prorénine est majoritaire (90%) et la rénine active ne représente que 10% de la rénine circulante. L'enzyme qui transforme, in vivo, la prorénine en rénine active n'est pas connue. De même, l'endroit précis du clivage n'est pas élucidé. Dans ce travail, nous avons généré plusieurs mutants de la prorénine et les avons exprimés dans deux types cellulaires : les CV1 (modèle constitutif) et AtT-20 (modèle régulé). Nous avons montré que la prorégion joue un rôle important aussi bien dans l'acquisition de l'activité enzymatique que dans la sécrétion de la rénine, mais fonctionne différemment d'un type cellulaire à l'autre. Nous avons montré pour la première fois que la prorégion interagit de façon intermoléculaire à l'intérieur de la cellule. Les expériences de complémentation montre que l'interaction favorable de la rénine avec la prorégion dépend de la taille de cette dernière : prorénine (383 acides aminés) > pro62 (62 acides aminés) > pro43 (43 acides aminés). Par ailleurs nos résultats montrent qu'une faible partie de la rénine est dirigée vers la voie de sécrétion régulée classique tandis que la majorité est dirigée vers les lysosomes. Ceci suggère qu'une internalisation de la rénine circulante via le récepteur mannose-6-phosphate est possible. Cette dernière concernerait essentiellement la prorénine (dont les taux circulants sont 10 fois plus élevés que la rénine active). La suite de ce travail porterait sur la confirmation de cette hypothèse et l'identification de son possible rôle physiologique. SUMMARY The renin-angiotensin system is critical for the control of blood pressure and salt balance and other physiological and pathological processes. When blood pressure is too low, renin is secreted by the juxtaglomerular cells. It will cleave the N-terminus of circulating angiotensinogen (mostly secreted by the liver) to angiotensin-1, which is then transformed in angiotensin-II by the angiotensin-converting-enzyme (ACE). This system is regulated at the level of renin release. Renin, an aspartyl protease, is produced from a larger precursor (called prorenin) which is matured into active renin. Although the role of the renin proregion remains unknown, it has been reported that it could act as an autoinhibitor. Works on other proteolytic enzymes showed that their prorégion can act as chaperones. prorenin is the major circulating form of renin, while active renin represents only 10%. The enzyme which transforms, in vivo, the prorenin into active renin is unknown and the exact cleavage site remains to be elucidated. In this study, we generated some prorenin mutants, which were expressed in CV1 cells (constitutive pathway model) or AtT-20 cells (regulated pathway model). We showed that the proregion plays a pivotal role in the enzymatic activity and secretion of renin in a different manner in the two cell types. For the first time, it has been demonstrated that the proregion acts in an intermolecular way into the cell. Complementation assays showed that interaction between renin and proregion depends on the size of the proregion: prorenin (383 amino acids) > pro62 (62 amino acids) > pro43 (43 amino acids). Furthermore, our results showed that only a small amount of the cellular renin pool is targeted to the "canonical" regulated pathway and that the remaining is targeted to the lysosomes. Those results suggest a possible internalizátion of the circulating renin through the mannose-6-phosphate receptor pathway. This would mostly concern the prorenin (whose levels are ten times higher than active renin). Further studies would confirm or infirm this hypothesis and elucidate a potential physiological role.
Resumo:
The response of Arabidopsis to stress caused by mechanical wounding was chosen as a model to compare the performances of high resolution quadrupole-time-of-flight (Q-TOF) and single stage Orbitrap (Exactive Plus) mass spectrometers in untargeted metabolomics. Both instruments were coupled to ultra-high pressure liquid chromatography (UHPLC) systems set under identical conditions. The experiment was divided in two steps: the first analyses involved sixteen unwounded plants, half of which were spiked with pure standards that are not present in Arabidopsis. The second analyses compared the metabolomes of mechanically wounded plants to unwounded plants. Data from both systems were extracted using the same feature detection software and submitted to unsupervised and supervised multivariate analysis methods. Both mass spectrometers were compared in terms of number and identity of detected features, capacity to discriminate between samples, repeatability and sensitivity. Although analytical variability was lower for the UHPLC-Q-TOF, generally the results for the two detectors were quite similar, both of them proving to be highly efficient at detecting even subtle differences between plant groups. Overall, sensitivity was found to be comparable, although the Exactive Plus Orbitrap provided slightly lower detection limits for specific compounds. Finally, to evaluate the potential of the two mass spectrometers for the identification of unknown markers, mass and spectral accuracies were calculated on selected identified compounds. While both instruments showed excellent mass accuracy (<2.5ppm for all measured compounds), better spectral accuracy was recorded on the Q-TOF. Taken together, our results demonstrate that comparable performances can be obtained at acquisition frequencies compatible with UHPLC on Q-TOF and Exactive Plus MS, which may thus be equivalently used for plant metabolomics.
Resumo:
Report for Minister Reilly on Beechpark Autism Services & related Service Issues for children with ASD in Dublin North Report for Minister Reilly on Beechpark Autism Services & related Service Issues for children with ASD in Dublin North Click here to download PDF 2MB
Resumo:
El projecte consisteix en el desenvolupament d'una comanda amb GeoMedia Professional 6.1 que permeti la representació temàtica de dades i ubicar-les sobre el mapa.
Resumo:
Thymus regression upon stressing stimuli, such as infectious diseases, is followed by organ reconstitution, paralleling its development in ontogeny. A narrow window of thymus development was here studied, encompassing the pro-T lymphoid precursor expansion during specification stages, by the use of epidermal growth factor plus insulin (INS) in murine fetal thymus organ cultures. Aiming to disclose signaling pathways related to these stages, cultured thymus lobes had their RNA extracted, for the search of transcripts differentially expressed using RNAse protection assays and reverse transcriptase-polymerase chain reactions. We found no difference that could explain INS-driven thymocyte growth, in the pattern of transcripts for death/proliferation mediators, or for a series of growth factor receptors and transcriptional regulators known as essential for thymus development. Thymocyte suspensions from cultured lobes, stained for phenotype analysis by fluorescence activated cell sorting, showed a decreased staining for Notch1 protein at cell surfaces upon INS addition. We analyzed the expression of Notch-related elements, and observed the recruitment of a specific set of transcripts simultaneous and compatible with INS-driven thymocyte growth, namely, transcripts for Notch3, for its ligand Jagged2, and for Deltex1, a mediator of a poorly characterized alternative pathway downstream of the Notch receptor.
Resumo:
L'objectiu és realitzar una explicació dels passos i les tasques realitzades per a la construcció d'un Sistema d'Informació Geogràfica (SIG) que permeti la gestió de vèrtex geodèsics de Catalunya i la implementació de l'algorisme de Delaunay sobre un conjunt de vèrtex seleccionats.
Resumo:
BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.