909 resultados para Amperometric measurements
Photoacoustics as a tool for the diagnosis of radicular stress: Measurements in eucalyptus seedlings
Resumo:
In reforesting companies (cellulose industry), eucalyptus is usually cultivated in small plastic containers (50 mL). As seedlings remain for about 120 days in these containers-until transplantation-their roots become space restricted, with consequent limitations in water and nutrient absorption. These restrictions may lead to plant stress, decreasing productivity. In this work, we used the photoacoustic technique to evaluate the photosynthetic activity of Eucalyptus grandis, E. urophylla and E. urograndis seedlings subjected to this limited space availability, seeking a correlation with morphological parameters and fluorescence measurements in these seedlings. Photoacoustic, fluorescence, and morphological analysis were conducted every 15 days, from 45 to 120 days after sowing. Fluorescence and photosynthetic rate were evaluated in vivo and in situ, the latter one using the open photoacoustic technique. Data show that root dry matter diminished markedly at 90 and 120 days after sowing; this behavior showed a high correlation with the gas exchange component of the photoacoustic signal, as well as with the fluorescence ratio Fv/Fm. These results indicate that the soil volume of the container becomes insufficient for the roots after 90 days, probably leading to a nutritional deficiency in plants, which explains the decrease observed in the photosynthetic rate of seedlings. (C) 2003 American Institute of Physics.
Resumo:
The layer-by-layer technique was exploited to immobilize the enzyme uricase onto indium tin oxide substrates coated with a layer of Prussian Blue. Uricase layers were alternated with either poly(ethylene imine) or poly(diallyidimethylammoniumchloride), and the resulting films were used as amperometric biosensors for uric acid. Biosensors with optimum perfomance had a limit of detection of 0.15 mu A mu mol 1(-1) cm(-2) with a linear response between 0.1 and 0.6 mu M of uric acid, which is sufficient for use in clinical tests. Bioactivity was preserved for weeks, and there was negligible influence from interferents, as detection was carried out at 0.0 V vs saturated calomel electrode.
Resumo:
An oxovanadium-salen complex (NAP-ethylene-bis(salicylidenciminato) oxovanadium) thin film deposited on a graphite-polyurethane electrode was investigated with regard to its potential use for detection of L-dopa in flow injection system. The oxovanadium(IV)/oxovanadium(V) redox couple of the modified electrode was found to mediate the L-dopa oxidation before its use in the FIA system. Experimental parameters, such as pH of the carrier solution, flow rate, sample volume injection and probable interferents were investigated. Under the optimized FIA conditions, the amperometric signal was linearly dependent on the L-dopa concentration over the range 1.0 x 10(-1) to 1.0 x 10(-4) mol L-1 (I-anodic, mu A) = 0.01 + 0.25 [L-dopa mu mol L-1]) with a detection limit (S/N = 3) of 8.0 x 10(-7) mol L-1 and a sampling frequency of 90 h(-1) was achieved. For a concentration of 1.0 x 10(-5) mol L-1 L-dopa, the R.S.D. of nine consecutive measurements was 3.7%. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A simple model is developed for the admittance of a metal-insulator-semiconductor (MIS) capacitor which includes the effect of a guard ring surrounding the Ohmic contact to the semiconductor. The model predicts most of the features observed in a MIS capacitor fabricated using regioregular poly(3-hexylthiophene) as the active semiconductor and polysilsesquioxane as the gate insulator. In particular, it shows that when the capacitor is driven into accumulation, the parasitic transistor formed by the guard ring and Ohmic contact can give rise to an additional feature in the admittance-voltage plot that could be mistaken for interface states. When this artifact and underlying losses in the bulk semiconductor are accounted for, the remaining experimental feature, a peak in the loss-voltage plot when the capacitor is in depletion, is identified as an interface (or near interface) state of density of similar to 4 x 10(10) cm(-2) eV(-1). Application of the model shows that exposure of a vacuum-annealed device to laboratory air produces a rapid change in the doping density in the channel region of the parasitic transistor but only slow changes in the bulk semiconductor covered by the gold Ohmic contact. (C) 2008 American Institute of Physics.
Resumo:
Hollandite-type manganese oxides are nanofibrous crystals with sub-nanometer open tunnels that provide a unique property for sensing applications. Sensor based on hollandite-type manganese oxide was investigated for amperometric detection of potassium. With an operating potential of +0.63 V versus SCE, potassium ions produce oxidation currents at the sensor, which can be exploited for quantitative determinations. The amperometric signals are linearly proportional to potassium ions concentration in the range 2.7 x 10(-4) to 9.1 x 10(-4) Mol l(-1) with a correlation coefficient of 0.9990. The construction and renewal are simple and inexpensive.
Resumo:
Phytase (myo-inositol hexaphosphate phosphohydrolase) and phytic acid (myo-inositol hexaphosphate) play an important environmental role, in addition to being a health issue in food industry. Phytic acid is antinutritional due to its ability to chelate metal ions and may also react with proteins decreasing their bioavailability. In this work, we produced biosensors with phytase immobilized in Layer-by-Layer (LbL) films, which could detect phytic acid with a detection limit of 0.19 mmol L-1, which is sufficient to detect phytic acid in seeds of grains and vegetables. The biosensosrs consisted of LbL films containing up to eight bilayers of phytase alternated with poly(allylamine) hydrochloride (PAH) deposited onto an indium-tin oxide (ITO) substrate modified with Prussian Blue. Amperometric detection was conducted in an acetate buffer solution (at pH 5.5) at room temperature, with the biosensor response attributed to the formation of phosphate ions. In subsidiary experiments with the currents measured at 0.0 V (vs. SCE), we demonstrated the absence of effects from some interferents, pointing to a good selectivity of the biosensor. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Anelastic relaxation measurements were performed in a Nb-46wt%Ti alloy, in the temperature range of 300 to 700 K, using a torsion pendulum operating at an oscillating frequency near 2.0 Hz. The samples were measured in different conditions: cold worked, annealed in ultra-high vacuum and doped with several quantities of nitrogen. The relaxation spectra obtained were resolved into their component peaks, corresponding to the different kinds of interaction of the interstitial solutes with the metallic matrix. The relaxation parameters of each process were calculated using Debye's elementary peaks.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The accurate identification of the nitrogen content in plants is extremely important since it involves economic aspects and environmental impacts, Several experimental tests have been carried out to obtain characteristics and parameters associated with the health of plants and its growing. The nitrogen content identification in plants involves a lot of non-linear parameters and complexes mathematical models. This paper describes a novel approach for identification of nitrogen content thought SPAD index using artificial neural networks (ANN). The network acts as identifier of relationships among, crop varieties, fertilizer treatments, type of leaf and nitrogen content in the plants (target). So, nitrogen content can be generalized and estimated and from an input parameter set. This approach can form the basis for development of an accurate real time system to predict nitrogen content in plants.
Resumo:
Radial profiles are reported of average and rms temperature in a propane flame for the first, second, and third acoustic modes at four different axial positions above the burner in a Rijke-tube combustor. Selected plots of the power spectral density (PSD) of temperature fluctuations are also reported. These radial profiles are then compared to similar ones made in the same flame, but in the absence of the acoustic field. Visual observations and photographs of the flame showed a remarkable change in flame height and structure with the onset of acoustic oscillations. This reduction in flame length, caused by the enhanced mixing due to the acoustic velocity fluctuations, gave rise to higher and lower average and rms temperatures near or well above the burner, respectively. In general, the PSD plots had a broad frequency content. The general trend was a decrease in magnitude with an increase in frequency. All cases presented broad-band peaks at around 5 Hz related to the flame flickering phenomenon. Preferred frequencies were observed in the oscillating PSD plots related to the fundamental frequency as well as subharmonics in the tube. (C) 2000 Elsevier B.V. Ltd. All rights reserved.
Resumo:
The effects of combustion driven acoustic oscillations in carbon monoxide and nitrogen oxides emission rates of a combustor operated with liquefied petroleum gas (LPG) were investigated. Because the fuel does not contain nitrogen, tests were also conducted with ammonia injected in the fuel, in order to study the formation of fuel NOx. The main conclusions were: (a) the pulsating combustion process is more efficient than the non-pulsating one and (b) the pulsating combustion process generates higher rates of NOx, with and without ammonia injection, as shown by CO and NO concentrations as function of the O-2 concentration. An increase in the LPG flow rate, keeping constant the air to fuel ratio, increased the acoustic pressure amplitude and the frequency of oscillation. The injection of ammonia had no influence on either pressure amplitude or frequency. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Plasmas generated in de discharges in aromatic compounds have been used for several years in polymerization processes. The chemical kinetics developed in such a plasma environment are extremely complicated. Therefore it is extremely important to set up optical and electrical diagnostics in order to establish the kinetics of the film growth, In this work we studied de plasmas generated ill low-pressure atmospheres of benzene for different values of gas pressure and power coupled to the discharge. The pressure range varied from 0.2 to 1.0 mbar for electric power running from 4 to 25 W, the main chemical species observed within the discharge were CH, H and C. It was observed that the CH relative concentration increases continuously with the power in the range investigated. The electron temperature varied from 0.5 to 2.0 eV with the increase of the power, for a fixed value of gas pressure. The relative dielectric constant of the plasma polymerized benzene was kept around 4.8 from 100 Hz to 10 kHz, presenting a resonance near 25 kHz. This electric behaviour of the film was the same fur different conditions of polymeric film deposition, (C) 1997 Elsevier B.V. S.A.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)