Monensin, a carboxylic acid ionophore, is commonly fed to poultry to control coccidiosis. A method for the detection and quantification of monensin residues in liver has been developed, Samples (3 g) were extracted with acetonitrile-water and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised against a monensin-transferrin conjugate, The limit of detection (mean + 3s) calculated from the analysis of 12 known negative samples was 2.91 ng g(-1). Intra- and inter-assay RSD were determined as 8.5 and 10.6%, respectively, using a liver sample fortified with 20 ng g(-1) monensin, A pharmacokinetic study in which 70 six week old broilers were fed monensin at a rate of 120 mg kg(-1) in their feed for 14 d resulted in mean monensin liver residues of 102 ng g(-1). However these had fallen below the limit of detection of the assay within the 3 d withdrawal period recommended by the manufacturer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunoaffinity chromatography (IAC) and affinity chromatography (AC:) are widely used for extraction of drugs from biological samples. Fifteen column types were purchased from five different manufacturers and;their ability to bind specific drugs including beta-agonists and anabolic steroids over a range of analyte concentrations in fortified bovine urine samples was assessed. The performance data obtained from these columns were compared with columns produced in this laboratory (in house columns). The in house columns gave the highest recoveries, ranging from 92 to 100% at the 1 ng spiking concentration, for five of the seven analytes assessed. Forty percent (11 of 27) of all the commercial column assessments recorded recoveries of less than 50% even when the lowest spiking concentration was applied (1 ng). For one manufacturer, only one of seven different columns purchased delivered extraction efficiencies greater than 50%. The extraction efficiencies of the clenbuterol columns were the highest with all commercially prepared columns showing at least 50% binding of radiolabelled tracer. Recoveries of alpha-nortestosterone were the lowest. The variability of these products with respect to quality control requires constant monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ivermectin, a member of the avermectin group, is frequently used to control parasites in many food producing animal species. A method for the detection and quantification of ivermectin residues in bovine liver has been developed. Liver samples (4 g) were extracted with acetonitrile and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised in rabbits against an ivermectin-transferrin conjugate, The limit of detection of the assay (mean +/- 3s) calculated from the analysis of 24 known negative samples was 1.6 ng g(-1), Intra- and inter-assay RSDs were determined as 8.8 and 14.6%, respectively, using a negative bovine liver sample fortified with 100 ng g(-1) of ivermectin. Four Friesian steers were treated with a pour-on application of ivermectin at a dose rate of 0.5 mg kg(-1) body mass then withdrawn and killed at 7, 14, 21 and 28 d, Livers mere removed and ivermectin residue concentrations determined using the proposed immunoassay procedure, Seven days post-treatment the ivermectin liver concentration was determined as 52.7 ng g(-1), decreasing to 4.1 ng(-1) at 28 d, All immunoassay results were confirmed using high-performance liquid chromatography (HPLC), The immunoassay and HPLC results for invermectin ranged from 1 to 58 ng g(-1) and were in close correlation (r = 0.99).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Steroids form a structurally closely related group. As a result, antibodies produced for use in immunoassays regularly show unwanted cross-reactivities, These may be reduced by altering hapten-protein coupling procedures, thereby reducing the exposure of the determinants giving rise to the undesirable cross-reaction. However, these procedures carl prove to be complex, expensive and nor totally predictable in outcome. Exploitation of the clonal selection theory is an attractive alternative approach. The host is primed with the interfering cross-reactant coupled to a non-immunogenic amino acid copolymer to inactivate the B-lymphocyte clones specific for this steroid, producing a specific immunotolerance. Then, 3 days Inter, the host is immunized with the steroid against which nn antibody is required. The clones producing antibody to this immunogen are unaffected and the cross-reactivity is significantly reduced or deleted The technique has been applied to the reduction of endogenous sex steroid cross-reactivity from antibodies prepared against synthetic and semi-synthetic androgens (17 alpha-methyltestosterone, 19-nor-beta-testosterone) and the progestogen medroxyprogesterone. Antibodies prepared against the synthetic oestrogen zeranol using this technique have significantly reduced its undesirable cross-reactivity with the fungal metabolite 7 alpha-zearalenol. Highly specific antisera have been generated in all cases, the only adverse effect being a reduction in the titres achieved in comparison with rabbits receiving the conventional immunizing regime.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The production of stable homogeneous reference materials containing the antimicrobial agent sulphadimidine in pig tissue is described. These were commissioned by the Community Bureau of Reference (BCR), established by the Commission of the European Communities, to promote improvements in analytical accuracy and to ensure uniformity of results determined by member states. Sulphadimidine-containing tissue powders (400 vials each of muscle, liver and kidney) were prepared by orally dosing pigs with drug, producing lyophilized tissue powders and blending these with negative tissues from unmedicated animals to achieve target concentrations. Details of the production process, the stabilizing procedure developed and the analytical assessments of homogeneity and stability are given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clenbuterol (CBL) can be used legally in the treatment of respiratory diseases and illegally as a growth promoter in animals, Liver and eye have previously been shown to be effective matrices for the detection of residual concentrations of the drug.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The detection of the illegal use of clenbuterol (CBL) as a growth promoter has relied on detecting residual concentrations of the drug in body fluids or tissues. Analysis of retinal extracts has recently been shown to considerably extend the detection period following withdrawal. The withdrawal periods required to eliminate residues from the liver and retina were investigated by medicating 20 cattle with CBL for 30 days; 6 control animals remained unmedicated. Residual concentrations were monitored throughout this period and for the subsequent 140 days. Concurrent changes in muscle areas and backfat thicknesses were recorded by ultrasound.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of the beta-agonist clenbuterol (CBL) as a growth promoter has been outlawed in European meat production. The detection of its illegal use is dependent on CBL residues persisting in animal tissues for longer than the withdrawal times given by abusers. A comparison of urine, bile and liver matrices indicated that analysis of the liver offered the best possibility for CBL detection. However, an experimental study showed that CBL detection following withdrawal could be further extended (up to 56 d) if the retina was used as the target tissue. Analysis of 703 retina and liver samples from cattle suspected of CBL medication revealed that 96 cattle had CBL residues present in their retinas, only 46 of these were liver positive. There were no instances of liver CBL residues being detected without the associated retina also being positive.