991 resultados para Absorption coefficient, 525 nm


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cu(II)/neocuproine (2,9-dimethyl-1,10-phenanthroline) complexes were utilized for spectrophotometric determination of total polyphenol content in beers. This procedure is based on the reduction of Cu(II) by polyphenols in hydroethanolic medium (pH 7.0) in the presence of neocuproine, yielding Cu(I)/complexes with maximum absorption at 454 nm. The sensitivity of the proposed method was compared with the AOAC method using tannic and gallic acid as standards. The average apparent molar absorptivity, in L cm(-1) mol(-1), of tannic acid (3.50 +/- 0.20) x 10(5) and gallic acid (5.12 +/- 0.21) x 10(4), was twice as high for the proposed method. A lower limit of detection (LOD) (2.9 x 10(-1) mg L-1) was found when tannic acid was used in the proposed method. Additionally, less interference from the most common additives in beers was noticed. Total content of polyphenols was analyzed in 17 Brazilian samples. Results ranged from 35.5 to 556 mg L-1 of tannic acid, with higher values for recovery rates (45.4-118%, mean 85.0%) than for gallic acid. Although tannic acid is a mixture of polygalloyl glucoses, the total polyphenol content found in the samples suggests that tannic acid should be used as a standard. This is the first attempt to use this particular copper complex to quantify total polyphenol content in beer samples. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The opto(electrical) properties and theoretical calculations of polyazomethine with vinylene and phenantridine moieties in the main chain were investigated in the present study. 2,5-Bis(hexyloxy)-1,4-bis[(2,5-bis(hexyloxy)-4-formyl-phenylenevinylene]benzene was polymerized in solution with 3,8-diamino-6-phenylphenanthridine (PAZ-PV-Ph). The temperatures of 5% weight loss (T-5%) of the polyazomethine was observed at 356 degrees C in nitrogen. Electrochemical properties of thin film of the polymer were studied by differential pulse voltammetry. The HOMO level of the PAZ-PV-Ph was at -4.97 eV. The energy band gap (E-g) was detected of approximately similar to 1.9 eV. Energy band gap (E-gopt) was additionally calculated from absorption spectrum and absorption coefficient alpha. The absorption UV-vis spectra of polyazomethine recorded in solution showed a blue shift in comparison with the solid state. HOMO-LUMO levels and E-g were additionally calculated theoretically by density functional theory and molecular simulations of PAZ-PV-Ph are presented. Current density-voltage (J-U) measurements were performed on ITO/PAZ-PV-Ph/Al, ITO/TiO2/PAZ-PV-Ph/Al and ITO/PEDOT/PAZ-PV-Ph:TiO2/Al devices in the dark and during irradiation with light (under illumination of 1000 W m(-2)). The polymer was tested using AFM technique and roughness (R-a, R-ms) along with skew and kurtosis are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nonlinear index of refraction (n(2)) and the two-photon absorption coefficient (beta) of water-based ferrofluids made of magnetite nanocrystals of different sizes and with different coatings have been measured through the Z-scan technique, with ultrashort (femtoseconds) laser pulses. Their third-order susceptibility is calculated from the values of n(2) and beta. The influence of different particles' coatings and sizes on these nonlinear optical properties are investigated. The values of n(2) and beta depend more significantly on the nanoparticles' size than on the particular coating. We observe a decrease of beta as the nanoparticles' diameters decrease, although the optical gap is found to be the same for all samples. The results are interpreted considering modifications in the electronic orbital shape due to the particles' nanosize effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit wird eine schmalbandige kontinuierliche kohärente Lyman-α-Quelle basierend auf Festkörperlasersystemen zur zukünftigen Kühlung von Antiwasserstoff vorgestellt. Die fundamentalen Festkörperlasersysteme ermöglichen es im Vier-Wellen-Misch-Prozess zur Erzeugung der Lyman-α-Strahlung nicht nur die 6^1S – 7^1S-Zwei-Photonen-Resonanz des Quecksilbers sondern erstmals auch die 6^1S – 6^3P-Ein-Photonen-Resonanz zur Erhöhung der Konversionseffizienz optimal zu nutzen. In ersten Messungen wurden 0,063nW Leistung bei Lyman-α erzeugt. Mit dieser Lyman-α-Quelle war es, durch die Nähe des ersten fundamentalen Lasers zur Ein-Photonen-Resonanz, erstmals möglich den kompletten Verlauf der Phasenanpassungskurve des Vier-Wellen- Misch-Prozesses aufzunehmen. Neben den fundamentalen Lasersystemen und der Lyman-alpha-Erzeugung selbst, wird in dieser Arbeit die Detektion der produzierten Lyman-α-Strahlung mit einem Photomultiplier vorgestellt, die soweit optimiert wurde, dass eine zuverlässige Abschätzung der erzeugten Leistung möglich ist. Für diesen Zweck wurde zudem ein Teststand aufgebaut, mit dem die Transmissivität der Optiken, welche in der Lyman-α-Apparatur verwendet werden, bei 121,56nm gemessen wurde. Des Weiteren wird hier eine vielseitige Rechnung vorgestellt, mit der die erzeugte Leistung bei Lyman-α, unter anderem in Abhängigkeit von der Temperatur, der Absorption des ersten fundamentalen Laserstrahls, dem Dichteprofil des Quecksilberdampfes und unter dem Einfluss eines Puffergases, bestimmt wird.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser tissue soldering (LTS) is a promising technique for tissue fusion based on a heat-denaturation process of proteins. Thermal damage of the fused tissue during the laser procedure has always been an important and challenging problem. Particularly in LTS of arterial blood vessels strong heating of the endothelium should be avoided to minimize the risk of thrombosis. A precise knowledge of the temperature distribution within the vessel wall during laser irradiation is inevitable. The authors developed a finite element model (FEM) to simulate the temperature distribution within blood vessels during LTS. Temperature measurements were used to verify and calibrate the model. Different parameters such as laser power, solder absorption coefficient, thickness of the solder layer, cooling of the vessel and continuous vs. pulsed energy deposition were tested to elucidate their impact on the temperature distribution within the soldering joint in order to reduce the amount of further animal experiments. A pulsed irradiation with high laser power and high absorbing solder yields the best results.