943 resultados para 3D motion capture
Resumo:
PURPOSE: To determine whether motion preservation following oblique cervical corpectomy (OCC) for cervical spondylotic myelopathy (CSM) persists with serial follow-up. METHODS: We included 28 patients with preoperative and at least two serial follow-up neutral and dynamic cervical spine radiographs who underwent OCC for CSM. Patients with an ossified posterior longitudinal ligament (OPLL) were excluded. Changes in sagittal curvature, segmental and whole spine range of motion (ROM) were measured. Nathan's system graded anterior osteophyte formation. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. RESULTS: The majority (23 patients) had a single or 2-level corpectomy. The average duration of follow-up was 45 months. The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). 17% of patients with preoperative lordotic spines had a loss of lordosis at last follow-up, but with no clinical worsening. 77% of the whole spine ROM and 62% of segmental ROM was preserved at last follow-up. The whole spine and segmental ROM decreased by 11.2° and 10.9°, respectively (p ≤ 0.001). Patients with a greater range of segmental movement preoperatively had a statistically greater range of movement at follow-up. The analysis of serial radiographs indicated that the range of movement of the whole spine and the range of movement at the segmental spine levels significantly reduced during the follow-up period. Nathan's grade showed increase in osteophytosis in more than two-thirds of the patients (p ≤ 0.01). The whole spine range of movement at follow-up significantly correlated with Nathan's grade. CONCLUSIONS: Although the OCC preserves segmental and whole spine ROM, serial measurements show a progressive decrease in ROM albeit without clinical worsening. The reduction in this ROM is probably related to degenerative ossification of spinal ligaments.
A filtering method to correct time-lapse 3D ERT data and improve imaging of natural aquifer dynamics
Resumo:
We have developed a processing methodology that allows crosshole ERT (electrical resistivity tomography) monitoring data to be used to derive temporal fluctuations of groundwater electrical resistivity and thereby characterize the dynamics of groundwater in a gravel aquifer as it is infiltrated by river water. Temporal variations of the raw ERT apparent-resistivity data were mainly sensitive to the resistivity (salinity), temperature and height of the groundwater, with the relative contributions of these effects depending on the time and the electrode configuration. To resolve the changes in groundwater resistivity, we first expressed fluctuations of temperature-detrended apparent-resistivity data as linear superpositions of (i) time series of riverwater-resistivity variations convolved with suitable filter functions and (ii) linear and quadratic representations of river-water-height variations multiplied by appropriate sensitivity factors; river-water height was determined to be a reliable proxy for groundwater height. Individual filter functions and sensitivity factors were obtained for each electrode configuration via deconvolution using a one month calibration period and then the predicted contributions related to changes in water height were removed prior to inversion of the temperature-detrended apparent-resistivity data. Applications of the filter functions and sensitivity factors accurately predicted the apparent-resistivity variations (the correlation coefficient was 0.98). Furthermore, the filtered ERT monitoring data and resultant time-lapse resistivity models correlated closely with independently measured groundwater electrical resistivity monitoring data and only weakly with the groundwater-height fluctuations. The inversion results based on the filtered ERT data also showed significantly less inversion artefacts than the raw data inversions. We observed resistivity increases of up to 10% and the arrival time peaks in the time-lapse resistivity models matched those in the groundwater resistivity monitoring data.
Resumo:
AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.
Resumo:
Visual perception of body motion is vital for everyday activities such as social interaction, motor learning or car driving. Tumors to the left lateral cerebellum impair visual perception of body motion. However, compensatory potential after cerebellar damage and underlying neural mechanisms remain unknown. In the present study, visual sensitivity to point-light body motion was psychophysically assessed in patient SL with dysplastic gangliocytoma (Lhermitte-Duclos disease) to the left cerebellum before and after neurosurgery, and in a group of healthy matched controls. Brain activity during processing of body motion was assessed by functional magnetic resonance imaging (MRI). Alterations in underlying cerebro-cerebellar circuitry were studied by psychophysiological interaction (PPI) analysis. Visual sensitivity to body motion in patient SL before neurosurgery was substantially lower than in controls, with significant improvement after neurosurgery. Functional MRI in patient SL revealed a similar pattern of cerebellar activation during biological motion processing as in healthy participants, but located more medially, in the left cerebellar lobules III and IX. As in normalcy, PPI analysis showed cerebellar communication with a region in the superior temporal sulcus, but located more anteriorly. The findings demonstrate a potential for recovery of visual body motion processing after cerebellar damage, likely mediated by topographic shifts within the corresponding cerebro-cerebellar circuitry induced by cerebellar reorganization. The outcome is of importance for further understanding of cerebellar plasticity and neural circuits underpinning visual social cognition.
Resumo:
Three-dimensional (3D) planning is becoming a more commonly used tool in maxillofacial surgery. At first used only virtually, 3D planning now also enables the creation of useful intraoperative aids such as cutting guides, which decrease the operative difficulty. In our center, we have used 3D planning in various domains of facial surgery and have investigated the advantages of this technique. We have also addressed the difficulties associated with its use. 3D planning increases the accuracy of reconstructive surgery, decreases operating time, whilst maintaining excellent esthetic results. However, its use is restricted to osseous reconstruction at this stage and once planning has been undertaken, it cannot be reversed or altered intraoperatively. Despite the attractive nature of this new tool, its uses and practicalities must be further evaluated. In particular, cost-effectiveness, hospital stay, and patient perceived benefits must be assessed.
Resumo:
PURPOSE: To develop and assess the diagnostic performance of a three-dimensional (3D) whole-body T1-weighted magnetic resonance (MR) imaging pulse sequence at 3.0 T for bone and node staging in patients with prostate cancer. MATERIALS AND METHODS This prospective study was approved by the institutional ethics committee; informed consent was obtained from all patients. Thirty patients with prostate cancer at high risk for metastases underwent whole-body 3D T1-weighted imaging in addition to the routine MR imaging protocol for node and/or bone metastasis screening, which included coronal two-dimensional (2D) whole-body T1-weighted MR imaging, sagittal proton-density fat-saturated (PDFS) imaging of the spine, and whole-body diffusion-weighted MR imaging. Two observers read the 2D and 3D images separately in a blinded manner for bone and node screening. Images were read in random order. The consensus review of MR images and the findings at prospective clinical and MR imaging follow-up at 6 months were used as the standard of reference. The interobserver agreement and diagnostic performance of each sequence were assessed on per-patient and per-lesion bases. RESULTS: The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significantly higher with whole-body 3D T1-weighted imaging than with whole-body 2D T1-weighted imaging regardless of the reference region (bone or fat) and lesion location (bone or node) (P < .003 for all). For node metastasis, diagnostic performance (area under the receiver operating characteristic curve) was higher for whole-body 3D T1-weighted imaging (per-patient analysis; observer 1: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P = .006 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging; observer 2: P = .006 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P = .006 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging), as was sensitivity (per-lesion analysis; observer 1: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P < .001 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging; observer 2: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P < .001 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging). CONCLUSION: Whole-body MR imaging is feasible with a 3D T1-weighted sequence and provides better SNR and CNR compared with 2D sequences, with a diagnostic performance that is as good or better for the detection of bone metastases and better for the detection of lymph node metastases.
Resumo:
INTRODUCTION: Partial splenectomy in children is a good surgical option for hematological diseases and focal splenic tumors because it allows the preservation of the spleen's immunological function. Furthermore, it can be performed by laparoscopy in children as it is a safe procedure, offering the benefits of a minimally invasive approach. MATERIALS AND METHODS: The software VR-render LE version 0.81 is a system that enables the visualization of bidimentional 3D images with magnification of anatomical details. We have applied this system to five cases of non-parasitic splenic cysts before laparoscopic partial splenectomy. RESULTS: The images obtained with VR rendering software permitted the preoperative reconstruction of the vascularization of the splenic hilum, allowing the surgeon safe vessel control during laparoscopic procedures. All five partial splenectomies were carried out with no complications or major blood loss. CONCLUSIONS: Laparoscopic partial splenectomy should be a first choice procedure because it is feasible, reproducible, and safe for children; furthermore, it preserves enough splenic tissue thereby preventing post-splenectomy infections. Volume rendering provides high anatomical resolution and can be useful in guiding the surgical procedure.
Resumo:
Eukaryotic transcription is tightly regulated by transcriptional regulatory elements, even though these elements may be located far away from their target genes. It is now widely recognized that these regulatory elements can be brought in close proximity through the formation of chromatin loops, and that these loops are crucial for transcriptional regulation of their target genes. The chromosome conformation capture (3C) technique presents a snapshot of long-range interactions, by fixing physically interacting elements with formaldehyde, digestion of the DNA, and ligation to obtain a library of unique ligation products. Recently, several large-scale modifications to the 3C technique have been presented. Here, we describe chromosome conformation capture sequencing (4C-seq), a high-throughput version of the 3C technique that combines the 3C-on-chip (4C) protocol with next-generation Illumina sequencing. The method is presented for use in mammalian cell lines, but can be adapted to use in mammalian tissues and any other eukaryotic genome.
Resumo:
Previously reported results on deep level optical spectroscopy, optical absorption, deep level transient spectroscopy, photoluminescence excitation, and time resolved photoluminescence are reviewed and discussed in order to know which are the mechanisms involved in electron capture and emission of the Ti acceptor level in GaP. First, the analysis indicates that the 3T1(F) crystal¿field excited state is not in resonance with the conduction band states. Second, it is shown that both the 3T2 and 3T1(F) excited states do not play any significant role in the process of electron emission and capture.
Resumo:
A method to determine the thermal cross section of a deep level from capacitance measurements is reported. The results enable us to explain the nonexponential behavior of the capacitance versus capture time when the trap concentration is not negligible with respect to that of the shallow one, and the Debye tail effects are taken into account. A figure of merit for the nonexponential behavior of the capture process is shown and discussed for different situations of doping and applied bias. We have also considered the influence of the position of the trap level"s energy on the nonexponentiality of the capture transient. The experimental results are given for the gold acceptor level in silicon and for the DX center in Al0.55 Ga0.45As, which are in good agreement with the developed theory.
Resumo:
A global existence and uniqueness result of the solution for multidimensional, time dependent, stochastic differential equations driven by a fractional Brownian motion with Hurst parameter H> is proved. It is shown, also, that the solution has finite moments. The result is based on a deterministic existence and uniqueness theorem whose proof uses a contraction principle and a priori estimates.